메뉴 건너뛰기




Volumn 9, Issue 3, 2009, Pages 92-97

The role of pulse transit time as an index of arterial stiffness during exercise

Author keywords

Arterial stiffness; Cardiac output; Steady state exercise; Systolic pressure

Indexed keywords

ADULT; ARTERIAL PRESSURE; ARTERIAL STIFFNESS; ARTICLE; BICYCLE ERGOMETER; BLOOD PRESSURE VARIABILITY; BREATHING RATE; CARDIOPULMONARY EXERCISE TEST; CARDIOPULMONARY FUNCTION; CARDIOVASCULAR PARAMETERS; CONTROLLED STUDY; CYCLING; HEART OUTPUT; HUMAN; HUMAN EXPERIMENT; MALE; MEAN ARTERIAL PRESSURE; NORMAL HUMAN; PLASMA VOLUME; PULSE TRANSIT TIME; STEADY STATE; SYSTOLE; SYSTOLIC BLOOD PRESSURE; VASCULAR RESISTANCE; VOLUNTEER; WORKLOAD;

EID: 70349309338     PISSN: 15678822     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10558-009-9081-4     Document Type: Article
Times cited : (23)

References (26)
  • 1
    • 34247467602 scopus 로고    scopus 로고
    • Photoplethysmography and its application in clinical physiological measurement
    • Allen J. Photoplethysmography and its application in clinical physiological measurement. Physiol Meas. 2007;28:R1-39.
    • (2007) Physiol Meas , vol.28
    • Allen, J.1
  • 3
    • 0000056001 scopus 로고
    • Determination of PvCO2 from the exponential CO2 rise during rebreathing
    • Defares JG. Determination of PvCO2 from the exponential CO2 rise during rebreathing. J Appl Physiol. 1958;13:159-64.
    • (1958) J Appl Physiol , vol.13 , pp. 159-164
    • Defares, J.G.1
  • 4
    • 0016232364 scopus 로고
    • Calculation of percentage changes in volumes of blood, plasma, and red cells in dehydration
    • Dill DB, Costill DL. Calculation of percentage changes in volumes of blood, plasma, and red cells in dehydration. J Appl Physiol. 1974;37:247-8.
    • (1974) J Appl Physiol , vol.37 , pp. 247-248
    • Dill, D.B.1    Costill, D.L.2
  • 6
    • 39749180861 scopus 로고    scopus 로고
    • Difference in pulse transit time between populations: A comparison between Caucasian and Chinese children in Australia
    • Foo JY, Lim CS. Difference in pulse transit time between populations: A comparison between Caucasian and Chinese children in Australia. J Med Eng Technol. 2008;32:162-6.
    • (2008) J Med Eng Technol , vol.32 , pp. 162-166
    • Foo, J.Y.1    Lim, C.S.2
  • 10
    • 0003431468 scopus 로고
    • Kleinbaum D, Kupper L, Muller K, editors. Boston, IN: PWS-KENT publishing company
    • Kleinbaum D, Kupper L, Muller K, editors. Applied regression analysis, other multivariate methods. Boston, IN: PWS-KENT publishing company; 1988.
    • (1988) Applied Regression Analysis, Other Multivariate Methods
  • 11
    • 0036667793 scopus 로고    scopus 로고
    • Validation of a device to measure arterial pulse wave velocity by a photoplethysmographic method
    • Loukogeorgakis S, Dawson R, Phillips N, Martyn CN, Greenwald SE. Validation of a device to measure arterial pulse wave velocity by a photoplethysmographic method. Physiol Meas. 2002;23(3):581-96.
    • (2002) Physiol Meas , vol.23 , Issue.3 , pp. 581-596
    • Loukogeorgakis, S.1    Dawson, R.2    Phillips, N.3    Martyn, C.N.4    Greenwald, S.E.5
  • 12
    • 42449101828 scopus 로고    scopus 로고
    • Changes of central haemodynamic parameters during mental stress and acute bouts of static and dynamic exercise
    • Lydakis C, Momen A, Blaha C, Gugoff S, Gray K, Herr M, et al. Changes of central haemodynamic parameters during mental stress and acute bouts of static and dynamic exercise. J Hum Hypertens. 2008;22:320-8.
    • (2008) J Hum Hypertens , vol.22 , pp. 320-328
    • Lydakis, C.1    Momen, A.2    Blaha, C.3    Gugoff, S.4    Gray, K.5    Herr, M.6
  • 13
    • 0021254771 scopus 로고
    • The relationship between arterial blood pressure and pulse transit time during dynamic and static exercise
    • Marie GV, Lo CR, Jones JV, Johnston DW. The relationship between arterial blood pressure and pulse transit time during dynamic and static exercise. Psychophysiology. 1984;21:521-7.
    • (1984) Psychophysiology , vol.21 , pp. 521-527
    • Marie, G.V.1    Lo, C.R.2    Jones, J.V.3    Johnston, D.W.4
  • 14
    • 0036450727 scopus 로고    scopus 로고
    • Cardiac output decline in prolonged dynamic exercise is affected by the exercise mode
    • Nassis GP, Geladas ND. Cardiac output decline in prolonged dynamic exercise is affected by the exercise mode. Pflugers Arch. 2002;445:398-404.
    • (2002) Pflugers Arch , vol.445 , pp. 398-404
    • Nassis, G.P.1    Geladas, N.D.2
  • 15
    • 15744372765 scopus 로고    scopus 로고
    • Clinical measurement of arterial stiffness obtained from noninvasive pressure waveforms
    • Nichols WW. Clinical measurement of arterial stiffness obtained from noninvasive pressure waveforms. Am J Hypertens. 2005;18:3S-10S.
    • (2005) Am J Hypertens , vol.18
    • Nichols, W.W.1
  • 16
    • 0037389062 scopus 로고    scopus 로고
    • Noninvasive assessment of arterial stiffness and risk of atherosclerotic events
    • Oliver JJ, Webb DJ. Noninvasive assessment of arterial stiffness and risk of atherosclerotic events. Arterioscler Thromb Vasc Biol. 2003;23:554-66.
    • (2003) Arterioscler Thromb Vasc Biol , vol.23 , pp. 554-566
    • Oliver, J.J.1    Webb, D.J.2
  • 17
    • 34447128061 scopus 로고    scopus 로고
    • A noninvasive parametric evaluation of stress effects on global cardiovascular function
    • Pan RL, Li JK. A noninvasive parametric evaluation of stress effects on global cardiovascular function. Cardiovasc Eng. 2007;7:74-80.
    • (2007) Cardiovasc Eng , vol.7 , pp. 74-80
    • Pan, R.L.1    Li, J.K.2
  • 18
    • 33644822671 scopus 로고    scopus 로고
    • Pulse transit time measured from the ECG: An unreliable marker of beat-to-beat blood pressure
    • Payne RA, Symeonides CN, Webb DJ, Maxwell SR. Pulse transit time measured from the ECG: An unreliable marker of beat-to-beat blood pressure. J Appl Physiol. 2006;100:136-41.
    • (2006) J Appl Physiol , vol.100 , pp. 136-141
    • Payne, R.A.1    Symeonides, C.N.2    Webb, D.J.3    Maxwell, S.R.4
  • 19
    • 0027982287 scopus 로고
    • Changes in pulse transit time and pulse rate as markers of arousal from sleep in normal subjects
    • Pitson D, Chhina N, Knijn S, van Herwaaden M, Stradling J. Changes in pulse transit time and pulse rate as markers of arousal from sleep in normal subjects. Clin Sci (Lond). 1994;87:269-73.
    • (1994) Clin Sci (Lond) , vol.87 , pp. 269-273
    • Pitson, D.1    Chhina, N.2    Knijn, S.3    van Herwaaden, M.4    Stradling, J.5
  • 20
    • 33745445589 scopus 로고    scopus 로고
    • Global versus local linear beat-to-beat analysis of the relationship between arterial pressure and pulse transit time during dynamic exercise
    • Porta A, Gasperi C, Nollo G, Lucini D, Pizzinelli P, Antolini R, et al. Global versus local linear beat-to-beat analysis of the relationship between arterial pressure and pulse transit time during dynamic exercise. Med Biol Eng Comput. 2006;44:331-7.
    • (2006) Med Biol Eng Comput , vol.44 , pp. 331-337
    • Porta, A.1    Gasperi, C.2    Nollo, G.3    Lucini, D.4    Pizzinelli, P.5    Antolini, R.6
  • 21
    • 0037782343 scopus 로고    scopus 로고
    • Current perspectives on arterial stiffness and pulse pressure in hypertension and cardiovascular diseases
    • Safar ME, Levy BI, Struijker-Boudier H. Current perspectives on arterial stiffness and pulse pressure in hypertension and cardiovascular diseases. Circulation. 2003;107:2864-9.
    • (2003) Circulation , vol.107 , pp. 2864-2869
    • Safar, M.E.1    Levy, B.I.2    Struijker-Boudier, H.3
  • 22
    • 0032897226 scopus 로고    scopus 로고
    • Pulse transit time: An appraisal of potential clinical applications
    • Smith RP, Argod J, Pepin JL, Levy PA. Pulse transit time: An appraisal of potential clinical applications. Thorax. 1999;54:452-7.
    • (1999) Thorax , vol.54 , pp. 452-457
    • Smith, R.P.1    Argod, J.2    Pepin, J.L.3    Levy, P.A.4
  • 23
    • 33745120147 scopus 로고    scopus 로고
    • The effect of applied sensor contact force on pulse transit time
    • Teng XF, Zhang YT. The effect of applied sensor contact force on pulse transit time. Physiol Meas. 2006;27:675-84.
    • (2006) Physiol Meas , vol.27 , pp. 675-684
    • Teng, X.F.1    Zhang, Y.T.2
  • 25
    • 24044540761 scopus 로고    scopus 로고
    • Is pulse transit time useful in differentiating respiratory events for patients with a sleep breathing disorder? A pilot study
    • Yin M, Miyazaki S, Itasaka Y, Shibata Y, Tanaka T, Abe T, et al. Is pulse transit time useful in differentiating respiratory events for patients with a sleep breathing disorder? A pilot study. Sleep Biol Rhythms. 2004;2:199-208.
    • (2004) Sleep Biol Rhythms , vol.2 , pp. 199-208
    • Yin, M.1    Miyazaki, S.2    Itasaka, Y.3    Shibata, Y.4    Tanaka, T.5    Abe, T.6
  • 26
    • 37448998878 scopus 로고    scopus 로고
    • Analysis of the effect of ageing on rising edge characteristics of the photoplethysmogram using a modified Windkessel model
    • Zahedi E, Chellappan K, Ali MA, Singh H. Analysis of the effect of ageing on rising edge characteristics of the photoplethysmogram using a modified Windkessel model. Cardiovasc Eng. 2007;7:172-81.
    • (2007) Cardiovasc Eng , vol.7 , pp. 172-181
    • Zahedi, E.1    Chellappan, K.2    Ali, M.A.3    Singh, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.