메뉴 건너뛰기




Volumn 18, Issue 5-6, 2004, Pages 333-342

Pulse transit time by r-wave-gated infrared photoplethysmography: Review of the literature and personal experience

Author keywords

Aterial stiffness; Blood pressure measurement; Dysautonomia; Infrared photoplethysmography; Sleep apnea

Indexed keywords

BIOLOGICAL ORGANS; BLOOD; CARDIOLOGY; FAILURE ANALYSIS; SIGNAL PROCESSING;

EID: 20944438037     PISSN: 13871307     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10877-005-4300-z     Document Type: Review
Times cited : (97)

References (57)
  • 1
    • 0032897226 scopus 로고    scopus 로고
    • Pulse transit time: An appraisal of potential clinical applications
    • 1:STN:280:DyaK1MzgvFWgtg%3D%3D
    • Smith RP, Argod J, Pepin JL, Levy PA. Pulse transit time: An appraisal of potential clinical applications. Thorax 1999; 54: 452-457. 1:STN:280:DyaK1MzgvFWgtg%3D%3D
    • (1999) Thorax , vol.54 , pp. 452-457
    • Smith, R.P.1    Argod, J.2    Pepin, J.L.3    Levy, P.A.4
  • 2
    • 0036174280 scopus 로고    scopus 로고
    • The difference in pulse transit time to the toe and finger measured by photoplethysmography
    • 10.1088/0967-3334/23/1/308
    • Nitzan M, Khanokh B, Slovik Y. The difference in pulse transit time to the toe and finger measured by photoplethysmography. Physiol Meas 2002; 23: 85-93. 10.1088/0967-3334/23/1/308
    • (2002) Physiol. Meas. , vol.23 , pp. 85-93
    • Nitzan, M.1    Khanokh, B.2    Slovik, Y.3
  • 3
    • 0029087202 scopus 로고
    • Assessment of arterial distensibility by automatic pulse wave velocity measurement. Validation and clinical application studies
    • 1:STN:280:ByqA2sjnslI%3D
    • Asmar R, Benetos A, Topouchian J, Laurent P, Pannier B, Brisac AM, Target R, Levy BI. Assessment of arterial distensibility by automatic pulse wave velocity measurement. Validation and clinical application studies. Hypertension 1995; 26: 485-490. 1:STN:280:ByqA2sjnslI%3D
    • (1995) Hypertension , vol.26 , pp. 485-490
    • Asmar, R.1    Benetos, A.2    Topouchian, J.3    Laurent, P.4    Pannier, B.5    Brisac, A.M.6    Target, R.7    Levy, B.I.8
  • 4
    • 0033082832 scopus 로고    scopus 로고
    • Carotid arterial stiffness as a surrogate for aortic stiffness: Relationship between carotid artery pressure-strain elastic modulus and aortic pulse wave velocity
    • 10.1016/S0301-5629(98)00146-X
    • Nagai Y, Fleg JL, Kemper MK, Rywik TM, Earley CJ, Metter EJ. Carotid arterial stiffness as a surrogate for aortic stiffness: Relationship between carotid artery pressure-strain elastic modulus and aortic pulse wave velocity. Ultrasound Med Biol 1999; 25: 181-188. 10.1016/ S0301-5629(98)00146-X
    • (1999) Ultrasound Med. Biol. , vol.25 , pp. 181-188
    • Nagai, Y.1    Fleg, J.L.2    Kemper, M.K.3    Rywik, T.M.4    Earley, C.J.5    Metter, E.J.6
  • 5
    • 0033139915 scopus 로고    scopus 로고
    • Isolated systolic hypertension, pulse pressure, and arterial stiffness as risk factors for cardiovascular disease
    • 1:STN:280:DC%2BD3M%2FhtVGqsA%3D%3D
    • O'Rourke MF. Isolated systolic hypertension, pulse pressure, and arterial stiffness as risk factors for cardiovascular disease. Curr Hypertens Rep 1999; 1: 204-211. 1:STN:280:DC%2BD3M%2FhtVGqsA%3D%3D
    • (1999) Curr. Hypertens. Rep. , vol.1 , pp. 204-211
    • O'Rourke, M.F.1
  • 6
    • 0036246185 scopus 로고    scopus 로고
    • Clinical applications of arterial stiffness; definitions and reference values
    • 10.1016/S0895-7061(01)02319-6
    • O'Rourke MF, Staessen JA, Vlachopoulos C, Duprez D, Plante GE. Clinical applications of arterial stiffness; definitions and reference values. Am J Hypertens 2002; 15: 426-444. 10.1016/S0895-7061(01)02319-6
    • (2002) Am. J. Hypertens. , vol.15 , pp. 426-444
    • O'Rourke, M.F.1    Staessen, J.A.2    Vlachopoulos, C.3    Duprez, D.4    Plante, G.E.5
  • 7
    • 0037360922 scopus 로고    scopus 로고
    • Arterial stiffness, gender and heart rate
    • 10.1097/00004872-200303000-00009
    • O'Rourke MF, Hayward CS. Arterial stiffness, gender and heart rate. J Hypertens 2003; 21: 487-490. 10.1097/00004872-200303000-00009
    • (2003) J. Hypertens. , vol.21 , pp. 487-490
    • O'Rourke, M.F.1    Hayward, C.S.2
  • 8
    • 0028804691 scopus 로고
    • Prospective assessment of an artificial neural network for the detection of peripheral vascular disease from lower limb pulse waveforms
    • 10.1088/0967-3334/16/1/003
    • Allen J, Murray A. Prospective assessment of an artificial neural network for the detection of peripheral vascular disease from lower limb pulse waveforms. Physiol Meas 1995; 16: 29-38. 10.1088/0967-3334/16/1/003
    • (1995) Physiol. Meas. , vol.16 , pp. 29-38
    • Allen, J.1    Murray, A.2
  • 9
    • 0033963050 scopus 로고    scopus 로고
    • Effect of age on brachial artery wall properties differs from the aorta and is gender dependent: A population study
    • 1:STN:280:DC%2BD3c7ksFylsQ%3D%3D
    • van der Heijden-Spek JJ, Staessen JA, Fagard RH, Hoeks AP, Boudier HA, van Bortel LM. Effect of age on brachial artery wall properties differs from the aorta and is gender dependent: A population study. Hypertension 2000; 35: 637-642. 1:STN:280:DC%2BD3c7ksFylsQ%3D%3D
    • (2000) Hypertension , vol.35 , pp. 637-642
    • van der Heijden-Spek, J.J.1    Staessen, J.A.2    Fagard, R.H.3    Hoeks, A.P.4    Boudier, H.A.5    van Bortel, L.M.6
  • 11
    • 0031688178 scopus 로고    scopus 로고
    • Relation between number of cardiovascular risk factors/events and noninvasive Doppler ultrasound assessments of aortic compliance
    • 1:STN:280:DyaK1cvhtlaitg%3D%3D
    • Lehmann ED, Hopkins KD, Rawesh A, Joseph RC, Kongola K, Coppack SW, Gosling RG. Relation between number of cardiovascular risk factors/ events and noninvasive Doppler ultrasound assessments of aortic compliance. Hypertension 1998; 32: 565-569. 1:STN:280:DyaK1cvhtlaitg%3D%3D
    • (1998) Hypertension , vol.32 , pp. 565-569
    • Lehmann, E.D.1    Hopkins, K.D.2    Rawesh, A.3    Joseph, R.C.4    Kongola, K.5    Coppack, S.W.6    Gosling, R.G.7
  • 12
    • 0027732066 scopus 로고
    • Aortic compliance measurements using Doppler ultrasound: In vivo biochemical correlates
    • 10.1016/0301-5629(93)90087-5
    • Lehmann ED, Hopkins KD, Gosling RG. Aortic compliance measurements using Doppler ultrasound: In vivo biochemical correlates. Ultrasound Med Biol 1993; 19: 683-710. 10.1016/0301-5629(93)90087-5
    • (1993) Ultrasound Med. Biol. , vol.19 , pp. 683-710
    • Lehmann, E.D.1    Hopkins, K.D.2    Gosling, R.G.3
  • 13
    • 0024121105 scopus 로고
    • Repeatability of peripheral pulse measurements on ears, fingers and toes using photoelectric plethysmography
    • 10.1088/0143-0815/9/4/003
    • Jago JR, Murray A. Repeatability of peripheral pulse measurements on ears, fingers and toes using photoelectric plethysmography. Clin Phys Physiol Meas 1988; 9: 319-330. 10.1088/0143-0815/9/4/003
    • (1988) Clin. Phys. Physiol. Meas. , vol.9 , pp. 319-330
    • Jago, J.R.1    Murray, A.2
  • 14
    • 0037358035 scopus 로고    scopus 로고
    • Pulse wave analysis and pulse wave velocity: A critical review of their strengths and weaknesses
    • 10.1097/00004872-200303000-00004
    • Davies JI, Struthers AD. Pulse wave analysis and pulse wave velocity: A critical review of their strengths and weaknesses. J Hypertens 2003; 21: 463-472. 10.1097/00004872-200303000-00004
    • (2003) J. Hypertens. , vol.21 , pp. 463-472
    • Davies, J.I.1    Struthers, A.D.2
  • 15
    • 0024459061 scopus 로고
    • Noninvasive assessment of central circulatory pressures by analysis of ear densitographic changes during Valsalva maneuver
    • 10.1016/0002-9149(89)90766-2
    • Bernardi L, Saviolo R, Spodick DH. Noninvasive assessment of central circulatory pressures by analysis of ear densitographic changes during Valsalva maneuver. Am J Cardiol 1989; 64: 787-792. 10.1016/ 0002-9149(89)90766-2
    • (1989) Am. J. Cardiol. , vol.64 , pp. 787-792
    • Bernardi, L.1    Saviolo, R.2    Spodick, D.H.3
  • 16
    • 0000461905 scopus 로고
    • Photoelectric plethysmography for estimating cutaneous blood flow
    • P Rolfe, ed. Academic Press London
    • AVJ Challoner 1979 Photoelectric plethysmography for estimating cutaneous blood flow. In P Rolfe, ed. Non-invasive physiologic measurements Academic Press London 125-151
    • (1979) Non-Invasive Physiologic Measurements , pp. 125-151
    • Challoner, A.V.J.1
  • 17
    • 0033928056 scopus 로고    scopus 로고
    • Comparison of esophageal pressure with pulse transit time as a measure of respiratory effort for scoring obstructive nonapneic respiratory events
    • 1:STN:280:DC%2BD3cvisFChtg%3D%3D
    • Argod J, Pepin JL, Smith RP, Levy P. Comparison of esophageal pressure with pulse transit time as a measure of respiratory effort for scoring obstructive nonapneic respiratory events. Am J Respir Crit Care Med 2000; 162: 87-93. 1:STN:280:DC%2BD3cvisFChtg%3D%3D
    • (2000) Am. J. Respir. Crit. Care Med. , vol.162 , pp. 87-93
    • Argod, J.1    Pepin, J.L.2    Smith, R.P.3    Levy, P.4
  • 18
    • 0034005951 scopus 로고    scopus 로고
    • Assessment of vascular aging and atherosclerosis in hypertensive subjects: Second derivative of photoplethysmogram versus pulse wave velocity
    • 10.1016/S0895-7061(99)00192-2
    • Bortolotto LA, Blacher J, Kondo T, Takazawa K, Safar ME. Assessment of vascular aging and atherosclerosis in hypertensive subjects: Second derivative of photoplethysmogram versus pulse wave velocity. Am J Hypertens 2000; 13: 165-171. 10.1016/S0895-7061(99)00192-2
    • (2000) Am. J. Hypertens. , vol.13 , pp. 165-171
    • Bortolotto, L.A.1    Blacher, J.2    Kondo, T.3    Takazawa, K.4    Safar, M.E.5
  • 19
    • 0033863524 scopus 로고    scopus 로고
    • Similarity in bilateral photoplethysmographic peripheral pulse wave characteristics at the ears, thumbs and toes
    • 10.1088/0967-3334/21/3/303
    • Allen J, Murray A. Similarity in bilateral photoplethysmographic peripheral pulse wave characteristics at the ears, thumbs and toes. Physiol Meas 2000; 21: 369-377. 10.1088/0967-3334/21/3/303
    • (2000) Physiol. Meas. , vol.21 , pp. 369-377
    • Allen, J.1    Murray, A.2
  • 20
    • 0034281859 scopus 로고    scopus 로고
    • Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration
    • 1:STN:280:DC%2BD3M%2Fks1Kkuw%3D%3D
    • Chen W, Tobahashi T, Ichikawa S, Takeuchi Y, Togawa T. Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration. Med Biol Eng Comput 2000; 38: 569-574. 1:STN:280:DC%2BD3M%2Fks1Kkuw%3D%3D
    • (2000) Med. Biol. Eng. Comput. , vol.38 , pp. 569-574
    • Chen, W.1    Tobahashi, T.2    Ichikawa, S.3    Takeuchi, Y.4    Togawa, T.5
  • 24
    • 0032033740 scopus 로고    scopus 로고
    • Continuous blood pressure monitoring during stress ECG
    • 1:STN:280:DyaK1c3hslKktQ%3D%3D
    • Barschdorff D, Erig M. Continuous blood pressure monitoring during stress ECG. Biomed Tech (Berl) 1998; 43: 34-39. 1:STN:280:DyaK1c3hslKktQ%3D%3D
    • (1998) Biomed. Tech. (Berl.) , vol.43 , pp. 34-39
    • Barschdorff, D.1    Erig, M.2
  • 25
    • 0029056268 scopus 로고
    • Evaluation of the pulse wave arrival time as a marker for blood pressure changes in critically ill infants and children
    • 10.1007/BF01616991
    • Wippermann CF, Schranz D, Huth RG. Evaluation of the pulse wave arrival time as a marker for blood pressure changes in critically ill infants and children. J Clin Monit 1995; 11: 324-328. 10.1007/BF01616991
    • (1995) J. Clin. Monit. , vol.11 , pp. 324-328
    • Wippermann, C.F.1    Schranz, D.2    Huth, R.G.3
  • 26
    • 0020541572 scopus 로고
    • Training and certification of blood pressure observers
    • Training and certification of blood pressure observers. Hypertension 1983; 5: 610-614.
    • (1983) Hypertension , vol.5 , pp. 610-614
  • 27
    • 0014542415 scopus 로고
    • The application of photoplethysmography to the recording of Valsalva maneuver responses
    • 1:STN:280:CCaB1MvgtlI%3D
    • Weinman J, Ben-Yaakov S, Sapoznikov D. The application of photoplethysmography to the recording of Valsalva maneuver responses. Israel J Med Sci 1969; 5: 534-536. 1:STN:280:CCaB1MvgtlI%3D
    • (1969) Israel J. Med. Sci. , vol.5 , pp. 534-536
    • Weinman, J.1    Ben-Yaakov, S.2    Sapoznikov, D.3
  • 29
    • 20944448176 scopus 로고    scopus 로고
    • Delay time between the R-wave and maximum pulse wave upstroke reflects alterations in blood pressure
    • Yano K, Kimora T, Sato Y, Nishiwaki K, Shimada Y. Delay time between the R-wave and maximum pulse wave upstroke reflects alterations in blood pressure. Anesthesiology 2002; 96: A491
    • (2002) Anesthesiology , vol.96
    • Yano, K.1    Kimora, T.2    Sato, Y.3    Nishiwaki, K.4    Shimada, Y.5
  • 30
    • 0001162774 scopus 로고
    • Use of pulse transit time as a measure of changes in inspiratory effort
    • Brock J, Pitson D, Strandling J. Use of pulse transit time as a measure of changes in inspiratory effort. J Ambul Monit 1993; 6: 295-302.
    • (1993) J. Ambul. Monit. , vol.6 , pp. 295-302
    • Brock, J.1    Pitson, D.2    Strandling, J.3
  • 31
    • 0027982287 scopus 로고
    • Changes in pulse transit time and pulse rate as markers of arousal from sleep in normal subjects
    • 1:STN:280:ByqD3cfmsVw%3D
    • Pitson D, Chhina N, Knijn S, van Herwaaden M, Stradling J. Changes in pulse transit time and pulse rate as markers of arousal from sleep in normal subjects. Clin Sci (Lond) 1994; 87: 269-273. 1:STN:280:ByqD3cfmsVw%3D
    • (1994) Clin. Sci. (Lond.) , vol.87 , pp. 269-273
    • Pitson, D.1    Chhina, N.2    Knijn, S.3    van Herwaaden, M.4    Stradling, J.5
  • 32
    • 0028168020 scopus 로고
    • Flow limitation as a noninvasive assessment of residual upper-airway resistance during continuous positive airway pressure therapy of obstructive sleep apnea
    • 1:STN:280:ByuA38ngsFY%3D
    • Condos R, Norman RG, Krishnasamy I, Peduzzi N, Goldring RM, Rapoport DM. Flow limitation as a noninvasive assessment of residual upper-airway resistance during continuous positive airway pressure therapy of obstructive sleep apnea. Am J Respir Crit Care Med 1994; 150: 475-480. 1:STN:280:ByuA38ngsFY%3D
    • (1994) Am. J. Respir. Crit. Care Med. , vol.150 , pp. 475-480
    • Condos, R.1    Norman, R.G.2    Krishnasamy, I.3    Peduzzi, N.4    Goldring, R.M.5    Rapoport, D.M.6
  • 33
    • 0033928056 scopus 로고    scopus 로고
    • Comparison of esophageal pressure with pulse transit time as a measure of respiratory effort for scoring obstructive nonapneic respiratory events
    • 1:STN:280:DC%2BD3cvisFChtg%3D%3D
    • Argod J, Pepin JL, Smith RP, Levy P. Comparison of esophageal pressure with pulse transit time as a measure of respiratory effort for scoring obstructive nonapneic respiratory events. Am J Respir Crit Care Med 2000; 162: 87-93. 1:STN:280:DC%2BD3cvisFChtg%3D%3D
    • (2000) Am. J. Respir. Crit. Care Med. , vol.162 , pp. 87-93
    • Argod, J.1    Pepin, J.L.2    Smith, R.P.3    Levy, P.4
  • 34
    • 0345040792 scopus 로고    scopus 로고
    • Differentiating obstructive and central sleep respiratory events through pulse transit time
    • 1:STN:280:DyaK1M%2FmsFKmsQ%3D%3D
    • Argod J, Pepin JL, Levy P. Differentiating obstructive and central sleep respiratory events through pulse transit time. Am J Respir Crit Care Med 1998; 158: 1778-1783. 1:STN:280:DyaK1M%2FmsFKmsQ%3D%3D
    • (1998) Am. J. Respir. Crit. Care Med. , vol.158 , pp. 1778-1783
    • Argod, J.1    Pepin, J.L.2    Levy, P.3
  • 35
    • 0031970652 scopus 로고    scopus 로고
    • Autonomic markers of arousal during sleep in patients undergoing investigation for obstructive sleep apnea, their relationship to EEG arousals, respiratory events and subjective sleepiness
    • 10.1046/j.1365-2869.1998.00092.x
    • Pitson DJ, Stradling JR. Autonomic markers of arousal during sleep in patients undergoing investigation for obstructive sleep apnea, their relationship to EEG arousals, respiratory events and subjective sleepiness. J Sleep Res. 1998; 7: 53-59. 10.1046/j.1365-2869.1998.00092.x
    • (1998) J. Sleep Res. , vol.7 , pp. 53-59
    • Pitson, D.J.1    Stradling, J.R.2
  • 37
    • 0036190775 scopus 로고    scopus 로고
    • Assessment of arterial stiffness in clinical practice
    • 10.1093/qjmed/95.2.67
    • Mackenzie IS, Wilkinson IB, Cockcroft JR. Assessment of arterial stiffness in clinical practice. QJM 2002; 95: 67-74. 10.1093/qjmed/ 95.2.67
    • (2002) QJM , vol.95 , pp. 67-74
    • Mackenzie, I.S.1    Wilkinson, I.B.2    Cockcroft, J.R.3
  • 38
    • 0032868906 scopus 로고    scopus 로고
    • Arterial stiffness and the development of hypertension. The ARIC study
    • 1:STN:280:DyaK1MzosVShtg%3D%3D
    • Liao D, Arnett DK, Tyroler HA, Riley WA, Chambless LE, Szklo M, Heiss G. Arterial stiffness and the development of hypertension. The ARIC study. Hypertension 1999; 34: 201-206. 1:STN:280:DyaK1MzosVShtg%3D%3D
    • (1999) Hypertension , vol.34 , pp. 201-206
    • Liao, D.1    Arnett, D.K.2    Tyroler, H.A.3    Riley, W.A.4    Chambless, L.E.5    Szklo, M.6    Heiss, G.7
  • 39
    • 0030810848 scopus 로고    scopus 로고
    • Direct magnetic resonance determination of aortic distensibility is essential hypertension: Relation to age, abdominal visceral fat and in situ intracellular free magnesium
    • Resnick LM, Militianu D, Cunnings AJ, Pipe JG, Evelhoch JL, Soulen RL. Direct magnetic resonance determination of aortic distensibility is essential hypertension: Relation to age, abdominal visceral fat and in situ intracellular free magnesium. Hypertension 1997; 30: 645-649.
    • (1997) Hypertension , vol.30 , pp. 645-649
    • Resnick, L.M.1    Militianu, D.2    Cunnings, A.J.3    Pipe, J.G.4    Evelhoch, J.L.5    Soulen, R.L.6
  • 40
    • 0032408206 scopus 로고    scopus 로고
    • Reproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis
    • 10.1097/00004872-199816121-00033
    • Wilkinson IB, Fuchs SA, Jansen IM, Spratt JC, Murray GD, Cockcroft JR, Webb DJ. Reproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis. J Hypertens 1998; 16: 2079-2084. 10.1097/00004872-199816121-00033
    • (1998) J. Hypertens. , vol.16 , pp. 2079-2084
    • Wilkinson, I.B.1    Fuchs, S.A.2    Jansen, I.M.3    Spratt, J.C.4    Murray, G.D.5    Cockcroft, J.R.6    Webb, D.J.7
  • 41
    • 0031050151 scopus 로고    scopus 로고
    • Increased pulse wave velocity and shortened pulse transmission time in hypertension and aging
    • 1:STN:280:ByiB2M7itlY%3D
    • Hasegawa M, Nagao K, Kinoshita Y, Rodbard D, Asahina A. Increased pulse wave velocity and shortened pulse transmission time in hypertension and aging. Cardiology 1997; 88: 147-151. 1:STN:280:ByiB2M7itlY%3D
    • (1997) Cardiology , vol.88 , pp. 147-151
    • Hasegawa, M.1    Nagao, K.2    Kinoshita, Y.3    Rodbard, D.4    Asahina, A.5
  • 42
    • 0029874537 scopus 로고    scopus 로고
    • Autonomic control of skin microvessels: Assessment by power spectrum of photoplethysmography
    • 1:STN:280:BymB28zhtFE%3D
    • Bernardi L, Radaelli A, Solda PL, Coats AJS, Reeder M. Autonomic control of skin microvessels: Assessment by power spectrum of photoplethysmography. Clin Sci 1996; 90: 345-355. 1:STN:280:BymB28zhtFE%3D
    • (1996) Clin. Sci. , vol.90 , pp. 345-355
    • Bernardi, L.1    Radaelli, A.2    Solda, P.L.3    Coats, A.J.S.4    Reeder, M.5
  • 44
    • 0025783230 scopus 로고
    • Cardiovascular neural regulation explored in the frequency domain
    • 1:STN:280:By6A3MnotVw%3D
    • Malliani A, Pagani M, Lombardi F, Cerruti S. Cardiovascular neural regulation explored in the frequency domain. Circulation 1991; 84: 482-492. 1:STN:280:By6A3MnotVw%3D
    • (1991) Circulation , vol.84 , pp. 482-492
    • Malliani, A.1    Pagani, M.2    Lombardi, F.3    Cerruti, S.4
  • 45
    • 0031910258 scopus 로고    scopus 로고
    • The variability of the photoplethysmographic signal - A potential method for the evaluation of the autonomic nervous system
    • 10.1088/0967-3334/19/1/008
    • Nitzan M, Babchenko A, Khanokh B, Landau D. The variability of the photoplethysmographic signal - A potential method for the evaluation of the autonomic nervous system. Physiol Meas 1998; 19: 92-102. 10.1088/ 0967-3334/19/1/008
    • (1998) Physiol. Meas. , vol.19 , pp. 92-102
    • Nitzan, M.1    Babchenko, A.2    Khanokh, B.3    Landau, D.4
  • 46
    • 0028789504 scopus 로고
    • Use of pulse transit time as a measure of inspiratory effort in patients with obstructive sleep apnoea
    • 10.1183/09031936.95.08101669
    • Pitson DJ, Sandell A, van den Hout R, Stradling JR. Use of pulse transit time as a measure of inspiratory effort in patients with obstructive sleep apnoea. Eur Respir J 1995; 8: 1669-1674. 10.1183/ 09031936.95.08101669
    • (1995) Eur. Respir. J. , vol.8 , pp. 1669-1674
    • Pitson, D.J.1    Sandell, A.2    van den Hout, R.3    Stradling, J.R.4
  • 47
    • 0002452488 scopus 로고    scopus 로고
    • Measurement of heart rate and blood pressure to evaluate disturbances in neurocardiovascular control
    • ChJ Mathias (ed.) 4rth ed. Oxford Univeristy Press Oxford, UK
    • W Wieling JM Karemaker 1999 Measurement of heart rate and blood pressure to evaluate disturbances in neurocardiovascular control. In ChJ Mathias (ed.) Autonomic failure. A textbook of clinical disorders of the autonomic nervous system 4th ed. Oxford Univeristy Press Oxford, UK 198-210
    • (1999) Autonomic Failure. A Textbook of Clinical Disorders of the Autonomic Nervous System , pp. 198-210
    • Wieling, W.1    Karemaker, J.M.2
  • 50
    • 12144290841 scopus 로고    scopus 로고
    • Disease-related phenotypes of cardiovascular reactivity as assessed by fractal and recurrence quantitative analysis of the heart rate and pulse transit time
    • 1:STN:280:DC%2BD2c%2Fos1Olsg%3D%3D
    • Naschitz JE, Rosner I, Rozenbaum M, Fields M, Isseroff H, Babich JP, Zuckerman E, Elias N, Yeshurun D, Naschitz S, Sabo E. Disease-related phenotypes of cardiovascular reactivity as assessed by fractal and recurrence quantitative analysis of the heart rate and pulse transit time. Q J Med 2004; 97: 141-151. 1:STN:280:DC%2BD2c%2Fos1Olsg%3D%3D
    • (2004) Q. J. Med. , vol.97 , pp. 141-151
    • Naschitz, J.E.1    Rosner, I.2    Rozenbaum, M.3    Fields, M.4    Isseroff, H.5    Babich, J.P.6    Zuckerman, E.7    Elias, N.8    Yeshurun, D.9    Naschitz, S.10    Sabo, E.11
  • 51
    • 0017261204 scopus 로고
    • Pulse wave velocity as a measure of blood pressure change
    • Gribbin B, Streptoe A, Sleight P. Pulse wave velocity as a measure of blood pressure change. Psychophysiology 1976; 12: 86-90.
    • (1976) Psychophysiology , vol.12 , pp. 86-90
    • Gribbin, B.1    Streptoe, A.2    Sleight, P.3
  • 52
    • 0019350715 scopus 로고
    • Pulse transit time as an indicator of arterial blood pressure
    • 1:STN:280:Bi6C38rgt1E%3D
    • Geddes LA, Voelz MH, Babbs CF, Buirland JD, Tacker WA. Pulse transit time as an indicator of arterial blood pressure. Psychophysiology 1981; 18: 71-74. 1:STN:280:Bi6C38rgt1E%3D
    • (1981) Psychophysiology , vol.18 , pp. 71-74
    • Geddes, L.A.1    Voelz, M.H.2    Babbs, C.F.3    Buirland, J.D.4    Tacker, W.A.5
  • 53
    • 0021373766 scopus 로고
    • Indirect blood pressure measurement by the pulse wave velocity method
    • 1:STN:280:BiuB1MzhsF0%3D
    • Tanaka H, Sakamoto K, Kanai H. Indirect blood pressure measurement by the pulse wave velocity method. Med Electron Biol Eng 1984; 22: 13-18. 1:STN:280:BiuB1MzhsF0%3D
    • (1984) Med. Electron. Biol. Eng. , vol.22 , pp. 13-18
    • Tanaka, H.1    Sakamoto, K.2    Kanai, H.3
  • 54
    • 0026685765 scopus 로고
    • Research of the main elements influencing blood pressure measurement by pulse wave velocity
    • 1:STN:280:ByyD2c7jvFA%3D
    • Lu W, Li H, Tao S, Zhang D, Jiang Z, Cui L, Tu J, Gou D. Research of the main elements influencing blood pressure measurement by pulse wave velocity. Front Med Biol Eng 1992; 4: 189-199. 1:STN:280:ByyD2c7jvFA%3D
    • (1992) Front Med. Biol. Eng. , vol.4 , pp. 189-199
    • Lu, W.1    Li, H.2    Tao, S.3    Zhang, D.4    Jiang, Z.5    Cui, L.6    Tu, J.7    Gou, D.8
  • 55
    • 0029056268 scopus 로고
    • Evaluation of pulse wave arrival time as a marker for blood pressure changes in critically ill infants and children
    • 10.1007/BF01616991
    • Wipperman CF, Schranz D, Huth RG. Evaluation of pulse wave arrival time as a marker for blood pressure changes in critically ill infants and children. J Clin Monit 1995; 11: 324-328. 10.1007/BF01616991
    • (1995) J. Clin. Monit. , vol.11 , pp. 324-328
    • Wipperman, C.F.1    Schranz, D.2    Huth, R.G.3
  • 56
    • 0029160570 scopus 로고
    • Clinical evaluation of continuous blood pressure monitoring: Accuracy and tracking capabilities
    • 10.1007/BF01617519
    • Young CC, Mark JB, White W, DeBree A, Vender JS, Fleming A. Clinical evaluation of continuous blood pressure monitoring: Accuracy and tracking capabilities. J Clin Monit 1995; 11: 245-252. 10.1007/BF01617519
    • (1995) J. Clin. Monit. , vol.11 , pp. 245-252
    • Young, C.C.1    Mark, J.B.2    White, W.3    DeBree, A.4    Vender, J.S.5    Fleming, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.