메뉴 건너뛰기




Volumn 37, Issue 2, 2013, Pages 150-161

Automatic and efficient contrast-based 2-D/3-D fusion for trans-catheter aortic valve implantation (TAVI)

Author keywords

2 D 3 D registration; Contrast agent inflow detection; Image guided intervention; Minimally invasive procedures; Trans catheter aortic valve implantation

Indexed keywords

2D/3D REGISTRATION; AORTIC VALVES; CONTRAST AGENT; IMAGE-GUIDED INTERVENTION; MINIMALLY INVASIVE;

EID: 84877007194     PISSN: 08956111     EISSN: 18790771     Source Type: Journal    
DOI: 10.1016/j.compmedimag.2013.01.008     Document Type: Article
Times cited : (14)

References (29)
  • 2
    • 84861577475 scopus 로고    scopus 로고
    • Transfemoral aortic valve replacement with the Edwards SAPIEN and Edwards SAPIEN XT prosthesis using exclusively local anesthesia and fluoroscopic guidance
    • Durand E., et al. Transfemoral aortic valve replacement with the Edwards SAPIEN and Edwards SAPIEN XT prosthesis using exclusively local anesthesia and fluoroscopic guidance. JACC Cardiovasc Intervent 2012, 5(5):461-467.
    • (2012) JACC Cardiovasc Intervent , vol.5 , Issue.5 , pp. 461-467
    • Durand, E.1
  • 3
    • 79958204372 scopus 로고    scopus 로고
    • Transcatheter versus surgical aortic-valve replacement in high-risk patients
    • Smith C.R., Leon M.B., Mack M.J., et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. New Engl J Med 2011, 364(23):2187-2198.
    • (2011) New Engl J Med , vol.364 , Issue.23 , pp. 2187-2198
    • Smith, C.R.1    Leon, M.B.2    Mack, M.J.3
  • 4
    • 79951770042 scopus 로고    scopus 로고
    • System to guide transcatheter aortic valve implantations based on interventional C-Arm CT imaging
    • MICCAI 2010
    • John M., Liao R., Zheng Y., Nottling A., Boese J., Kirschstein U., et al. System to guide transcatheter aortic valve implantations based on interventional C-Arm CT imaging. LNCS 2010, 6361:375-382. MICCAI 2010.
    • (2010) LNCS , vol.6361 , pp. 375-382
    • John, M.1    Liao, R.2    Zheng, Y.3    Nottling, A.4    Boese, J.5    Kirschstein, U.6
  • 5
    • 84870486474 scopus 로고    scopus 로고
    • Automatic aorta segmentation and valve landmark detection in C-Arm CT: application to aortic valve implantation
    • MICCAI 2010
    • Zheng Y., John M., Liao R., Boese J., Kirschstein U., Comaniciu D. Automatic aorta segmentation and valve landmark detection in C-Arm CT: application to aortic valve implantation. LNCS 2010, 6361:476-483. MICCAI 2010.
    • (2010) LNCS , vol.6361 , pp. 476-483
    • Zheng, Y.1    John, M.2    Liao, R.3    Boese, J.4    Kirschstein, U.5    Comaniciu, D.6
  • 6
    • 79955865372 scopus 로고    scopus 로고
    • Automatic detection of contrast injection on fluoroscopy and angiography for image guided trans-catheter aortic valve implantations (TAVI)
    • 79640Z-79640Z-7, SPIE 2011
    • Liao R., You W., Yan M., John M. Automatic detection of contrast injection on fluoroscopy and angiography for image guided trans-catheter aortic valve implantations (TAVI). Proc SPIE 2011, 7964. pp. 79640Z-79640Z-7, SPIE 2011.
    • (2011) Proc SPIE , vol.7964
    • Liao, R.1    You, W.2    Yan, M.3    John, M.4
  • 7
    • 84860241975 scopus 로고    scopus 로고
    • Extended contrast detection on fluoroscopy and angiography for image guided trans-catheter aortic valve implantations (TAVI)
    • 831618-1831618-9, SPIE 2012
    • Liu Y., Liao R., Lv X. Extended contrast detection on fluoroscopy and angiography for image guided trans-catheter aortic valve implantations (TAVI). Proc SPIE 2012, 8316. pp. 831618-1831618-9, SPIE 2012.
    • (2012) Proc SPIE , vol.8316
    • Liu, Y.1    Liao, R.2    Lv, X.3
  • 8
    • 80055059610 scopus 로고    scopus 로고
    • A hybrid method for 2-D/3-D registration between 3-D volume and 2-D angiography for trans-catheter aortic valve implantation (TAVI)
    • ISBI 2011
    • Miao S., Liao R., Zheng Y. A hybrid method for 2-D/3-D registration between 3-D volume and 2-D angiography for trans-catheter aortic valve implantation (TAVI). Proc IEEE ISBI 2011, 1215-1218. ISBI 2011.
    • (2011) Proc IEEE ISBI , pp. 1215-1218
    • Miao, S.1    Liao, R.2    Zheng, Y.3
  • 9
    • 85088766528 scopus 로고    scopus 로고
    • 3D/2D registration via skeletal near projective invariance in tubular objects
    • MICCAI 1998
    • Liu A., Bulliitt E., Pizer S.M. 3D/2D registration via skeletal near projective invariance in tubular objects. LNCS 1998, 1496:780-787. MICCAI 1998.
    • (1998) LNCS , vol.1496 , pp. 780-787
    • Liu, A.1    Bulliitt, E.2    Pizer, S.M.3
  • 10
    • 84876994061 scopus 로고    scopus 로고
    • Curve-based registration of coronary vessels for image guided navigation in interventional cardiology
    • 72610S-172610S-10, SPIE 2009
    • Duong L., Liao R., Sundar H., Tailhades B., Meyer A., Xu C. Curve-based registration of coronary vessels for image guided navigation in interventional cardiology. Proc SPIE 2009, 7261. pp. 72610S-172610S-10, SPIE 2009.
    • (2009) Proc SPIE , vol.7261
    • Duong, L.1    Liao, R.2    Sundar, H.3    Tailhades, B.4    Meyer, A.5    Xu, C.6
  • 11
    • 84947807416 scopus 로고    scopus 로고
    • Real-time registration of 3D cerebral vessels to X-ray angiograms
    • MICCAI 1998
    • Kita Y., Wilson D.L., Nobel J.A. Real-time registration of 3D cerebral vessels to X-ray angiograms. LNCS 1998, 1496:1125-1133. MICCAI 1998.
    • (1998) LNCS , vol.1496 , pp. 1125-1133
    • Kita, Y.1    Wilson, D.L.2    Nobel, J.A.3
  • 14
    • 0027996228 scopus 로고
    • A patient-to-computed-tomography image registration method based on digitally reconstructed radiographs
    • Lemieux L., Jagoe R., Fish D.R., Kitchen N.D., Thomas D.G. A patient-to-computed-tomography image registration method based on digitally reconstructed radiographs. Med Phys 1994, 21(11):1749-1760.
    • (1994) Med Phys , vol.21 , Issue.11 , pp. 1749-1760
    • Lemieux, L.1    Jagoe, R.2    Fish, D.R.3    Kitchen, N.D.4    Thomas, D.G.5
  • 15
    • 67149127040 scopus 로고    scopus 로고
    • A planning system for transapical aortic valve implantation
    • 72611E-72611E-12, SPIE 2009
    • Gessat M., Merk D.R., Falk V., Walther T., Jacobs S., Nöttling A., et al. A planning system for transapical aortic valve implantation. Proc SPIE 2009, 7261. pp. 72611E-72611E-12, SPIE 2009.
    • (2009) Proc SPIE , vol.7261
    • Gessat, M.1    Merk, D.R.2    Falk, V.3    Walther, T.4    Jacobs, S.5    Nöttling, A.6
  • 16
    • 84862246782 scopus 로고    scopus 로고
    • Dynamic model-driven quantification and visual evaluation of the aortic valve from 4D CT
    • MICCAI 2008
    • Ionasec R., Georgescu B., Gassner E., Vogt S., Kutter O., Scheuering M., et al. Dynamic model-driven quantification and visual evaluation of the aortic valve from 4D CT. LNCS 2008, 5241:686-694. MICCAI 2008.
    • (2008) LNCS , vol.5241 , pp. 686-694
    • Ionasec, R.1    Georgescu, B.2    Gassner, E.3    Vogt, S.4    Kutter, O.5    Scheuering, M.6
  • 17
    • 67149136732 scopus 로고    scopus 로고
    • Localization and tracking of aortic valve prosthesis in 2D fluoroscopic image sequences
    • 72611Q-72611Q-8, SPIE 2009
    • Karar M.E., Chalopin C., Merk D.R., Jacobs S., Walther T., Falk V., et al. Localization and tracking of aortic valve prosthesis in 2D fluoroscopic image sequences. Proc SPIE 2009, 7261. pp. 72611Q-72611Q-8, SPIE 2009.
    • (2009) Proc SPIE , vol.7261
    • Karar, M.E.1    Chalopin, C.2    Merk, D.R.3    Jacobs, S.4    Walther, T.5    Falk, V.6
  • 18
    • 58949104358 scopus 로고    scopus 로고
    • Robotic system for transapical aortic valve replacement with MRI guidance
    • MICCAI 2008
    • Li M., Mazilu D., Horvath K.A. Robotic system for transapical aortic valve replacement with MRI guidance. LNCS 2008, 5241:476-484. MICCAI 2008.
    • (2008) LNCS , vol.5241 , pp. 476-484
    • Li, M.1    Mazilu, D.2    Horvath, K.A.3
  • 20
    • 71649094641 scopus 로고    scopus 로고
    • DynaCT during minimally invasive off-pump transapical aortic valve implantation
    • Kempfert J., Falk V., Schuler G., Linke A., Merk D.R., Mohr F.W., et al. DynaCT during minimally invasive off-pump transapical aortic valve implantation. Ann Thorac Surg 2009, 88(6):2041.
    • (2009) Ann Thorac Surg , vol.88 , Issue.6 , pp. 2041
    • Kempfert, J.1    Falk, V.2    Schuler, G.3    Linke, A.4    Merk, D.R.5    Mohr, F.W.6
  • 21
  • 22
    • 33645191605 scopus 로고    scopus 로고
    • Fast detection and processing of arbitrary contrast agent injections in coronary angiography and fluoroscopy
    • CEUR 2004
    • Condurache A., Aach T., Eck K., Bredno J. Fast detection and processing of arbitrary contrast agent injections in coronary angiography and fluoroscopy. Proc CEUR 2004, 116:5-9. CEUR 2004.
    • (2004) Proc CEUR , vol.116 , pp. 5-9
    • Condurache, A.1    Aach, T.2    Eck, K.3    Bredno, J.4
  • 23
    • 80053512727 scopus 로고    scopus 로고
    • Robust and fast contrast agent inflow detection for 2D X-ray fluoroscopy
    • MICCAI 2011
    • Chen T., Funka-Lea G., Comaniciu D. Robust and fast contrast agent inflow detection for 2D X-ray fluoroscopy. LNCS 2011, 6891:243-250. MICCAI 2011.
    • (2011) LNCS , vol.6891 , pp. 243-250
    • Chen, T.1    Funka-Lea, G.2    Comaniciu, D.3
  • 24
    • 28744457292 scopus 로고    scopus 로고
    • Automatic registration of portal images and volumetric CT for patient positioning in radiation therapy
    • Khamene A., Bloch P., Wein W., Svatos M., Sauer F. Automatic registration of portal images and volumetric CT for patient positioning in radiation therapy. Med Image Anal 2005, 10(1):96-112.
    • (2005) Med Image Anal , vol.10 , Issue.1 , pp. 96-112
    • Khamene, A.1    Bloch, P.2    Wein, W.3    Svatos, M.4    Sauer, F.5
  • 25
    • 42949176077 scopus 로고    scopus 로고
    • A fast, accurate, and automatic 2D-3D image registration for image-guided cranial radiosurgery
    • Fu D., Kuduvalli G. A fast, accurate, and automatic 2D-3D image registration for image-guided cranial radiosurgery. Med Phys 2008, 35(5):2180-2194.
    • (2008) Med Phys , vol.35 , Issue.5 , pp. 2180-2194
    • Fu, D.1    Kuduvalli, G.2
  • 26
    • 66249114362 scopus 로고    scopus 로고
    • Deformable 2D-3D registration of vascular structures in a one view scenario
    • Groher M., Zikic D., Navab N. Deformable 2D-3D registration of vascular structures in a one view scenario. IEEE Trans Med Imaging 2009, 28(6):847-860.
    • (2009) IEEE Trans Med Imaging , vol.28 , Issue.6 , pp. 847-860
    • Groher, M.1    Zikic, D.2    Navab, N.3
  • 27
    • 77955223785 scopus 로고    scopus 로고
    • 2-D/3-D registration of computed tomographic volumes with fluoroscopic images by spines for EP applications
    • ISBI 2010
    • Liao R. 2-D/3-D registration of computed tomographic volumes with fluoroscopic images by spines for EP applications. Proc IEEE ISBI 2010, 1213-1216. ISBI 2010.
    • (2010) Proc IEEE ISBI , pp. 1213-1216
    • Liao, R.1
  • 28
    • 79957989867 scopus 로고    scopus 로고
    • Automatic image-based cardiac and respiratory cycle synchronization and gating of image sequences
    • MICCAI 2009
    • Sundar H., Khamene A., Yatziv L., Xu C. Automatic image-based cardiac and respiratory cycle synchronization and gating of image sequences. LNCS 2009, 5762:381-388. MICCAI 2009.
    • (2009) LNCS , vol.5762 , pp. 381-388
    • Sundar, H.1    Khamene, A.2    Yatziv, L.3    Xu, C.4
  • 29
    • 80055051922 scopus 로고    scopus 로고
    • Spatial-temporal analysis for automatic contrast injection detection on angiography during trans-catheter aortic valve implantations
    • ISBI 2010
    • You W., Liao R., Yan M., John M. Spatial-temporal analysis for automatic contrast injection detection on angiography during trans-catheter aortic valve implantations. Proc IEEE ISBI 2010, 702-706. ISBI 2010.
    • (2010) Proc IEEE ISBI , pp. 702-706
    • You, W.1    Liao, R.2    Yan, M.3    John, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.