메뉴 건너뛰기




Volumn 6361 LNCS, Issue PART 1, 2010, Pages 476-483

Automatic aorta segmentation and valve landmark detection in C-arm CT: Application to aortic valve implantation

Author keywords

[No Author keywords available]

Indexed keywords

3-D MEASUREMENT; 3D SEGMENTATION; AORTA MODEL; AORTIC ARCH; AORTIC ROOT; AORTIC VALVES; COMPUTATIONALLY EFFICIENT; CONTRAST AGENT; CT VOLUME; DATA SETS; DISCRIMINATIVE LEARNING; DOMAIN KNOWLEDGE; FLUOROSCOPIC IMAGES; HINGE POINT; LANDMARK DETECTION; REAL TIME; STRUCTURE VARIATION; SURGERY PLANNING; TRANSCATHETER; VISUAL GUIDANCE;

EID: 84870486474     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-642-15705-9_58     Document Type: Conference Paper
Times cited : (72)

References (12)
  • 5
    • 0031240179 scopus 로고    scopus 로고
    • Automatic tracking of the aorta in cardiovascular mr images using deformable models
    • PII S0278006297075897
    • Rueckert, D., Burger, P., Forbat, S.M., Mohiaddin, R.D., Yang, G.Z.: Automatic tracking of the aorta in cardiovascular MR images using deformable models. IEEE Trans. Medical Imaging 16(5), 581-590 (1997) (Pubitemid 127767636)
    • (1997) IEEE Transactions on Medical Imaging , vol.16 , Issue.5 , pp. 581-590
    • Rueckert, D.1
  • 6
    • 0042767034 scopus 로고    scopus 로고
    • Robust segmentation of tubular structures in 3-D medical images by parametric object detection and tracking
    • Behrens, T., Rohr, K., Stiehl, H.H.: Robust segmentation of tubular structures in 3-D medical images by parametric object detection and tracking. IEEE Trans. Syst., Man, Cybern. B 33(14), 554-561 (2003)
    • (2003) IEEE Trans. Syst., Man, Cybern. B , vol.33 , Issue.14 , pp. 554-561
    • Behrens, T.1    Rohr, K.2    Stiehl, H.H.3
  • 10
    • 54949104993 scopus 로고    scopus 로고
    • Four-chamber heart modeling and automatic segmentation for 3D cardiac CT volumes using marginal space learning and steerable features
    • Zheng, Y., Barbu, A., Georgescu, B., Scheuering, M., Comaniciu, D.: Four-chamber heart modeling and automatic segmentation for 3D cardiac CT volumes using marginal space learning and steerable features. IEEE Trans. Medical Imaging 27(11), 1668-1681 (2008)
    • (2008) IEEE Trans. Medical Imaging , vol.27 , Issue.11 , pp. 1668-1681
    • Zheng, Y.1    Barbu, A.2    Georgescu, B.3    Scheuering, M.4    Comaniciu, D.5
  • 11
    • 84957597822 scopus 로고    scopus 로고
    • Optimal surface smoothing as filter design
    • Taubin, G.: Optimal surface smoothing as filter design. In: Proc. European Conf. Computer Vision, pp. 283-292 (1996)
    • (1996) Proc. European Conf. Computer Vision , pp. 283-292
    • Taubin, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.