-
1
-
-
0026539951
-
Effect of stationary guiding vanes on improvement of the washout behind the rotor in centrifugal blood pumps
-
Schima H, Huber L, Melvin D, etal. Effect of stationary guiding vanes on improvement of the washout behind the rotor in centrifugal blood pumps. ASAIO J 1992;38:220-224.
-
(1992)
ASAIO J
, vol.38
, pp. 220-224
-
-
Schima, H.1
Huber, L.2
Melvin, D.3
-
2
-
-
79953820743
-
Neurological complications of extracorporeal membrane oxygenation in children
-
Hervey-Jumper SL, Annich GM, Yancon AR, etal. Neurological complications of extracorporeal membrane oxygenation in children. J Neurosurg Pediatr 2011;7:338-344.
-
(2011)
J Neurosurg Pediatr
, vol.7
, pp. 338-344
-
-
Hervey-Jumper, S.L.1
Annich, G.M.2
Yancon, A.R.3
-
3
-
-
15344348062
-
Plasma leakage of oxygenators in ECMO depends on the type of oxygenator and on patient variables
-
Meyns B, Vercaemst L, Vandezande E, etal. Plasma leakage of oxygenators in ECMO depends on the type of oxygenator and on patient variables. Int J Artif Organs 2005;28:30-34.
-
(2005)
Int J Artif Organs
, vol.28
, pp. 30-34
-
-
Meyns, B.1
Vercaemst, L.2
Vandezande, E.3
-
4
-
-
78649612553
-
Evolution of the extracorporeal life support circuitry
-
Palanzo D, Qiu F, Baer L, etal. Evolution of the extracorporeal life support circuitry. Artif Organs 2010;34:869-873.
-
(2010)
Artif Organs
, vol.34
, pp. 869-873
-
-
Palanzo, D.1
Qiu, F.2
Baer, L.3
-
5
-
-
81855182168
-
Neonatal extracorporeal life support: will the newest technology reduce morbidity?
-
Reed-Thurston D, Shenberger J, Qiu F, etal. Neonatal extracorporeal life support: will the newest technology reduce morbidity? Artif Organs 2011;35:989-996.
-
(2011)
Artif Organs
, vol.35
, pp. 989-996
-
-
Reed-Thurston, D.1
Shenberger, J.2
Qiu, F.3
-
6
-
-
10944263820
-
The CentriMag: a new optimized centrifugal blood pump with levitating impeller
-
Mueller JP, Kuenzli A, Reuthebuch O, etal. The CentriMag: a new optimized centrifugal blood pump with levitating impeller. Heart Surg Forum 2004;7:E477-480.
-
(2004)
Heart Surg Forum
, vol.7
-
-
Mueller, J.P.1
Kuenzli, A.2
Reuthebuch, O.3
-
7
-
-
33644993283
-
Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the CentriMag blood pump
-
Zhang J, Gellman B, Koert A, etal. Computational and experimental evaluation of the fluid dynamics and hemocompatibility of the CentriMag blood pump. Artif Organs 2006;30:168-177.
-
(2006)
Artif Organs
, vol.30
, pp. 168-177
-
-
Zhang, J.1
Gellman, B.2
Koert, A.3
-
8
-
-
79952985548
-
Outcomes of a multicenter trial of the Levitronix CentriMag ventricular assist system for short-term circulatory support
-
John R, Long JW, Massey HT, etal. Outcomes of a multicenter trial of the Levitronix CentriMag ventricular assist system for short-term circulatory support. J Thorac Cardiovasc Surg 2011;141:932-939.
-
(2011)
J Thorac Cardiovasc Surg
, vol.141
, pp. 932-939
-
-
John, R.1
Long, J.W.2
Massey, H.T.3
-
9
-
-
72249098773
-
Initial experience with CentriMag extracorporal membrane oxygenation for support of critically ill patients with refractory cardiogenic shock
-
Aziz TA, Singh G, Popjes E, etal. Initial experience with CentriMag extracorporal membrane oxygenation for support of critically ill patients with refractory cardiogenic shock. J Heart Lung Transplant 2010;29:66-71.
-
(2010)
J Heart Lung Transplant
, vol.29
, pp. 66-71
-
-
Aziz, T.A.1
Singh, G.2
Popjes, E.3
-
10
-
-
0029079971
-
Seal-less centrifugal blood pump with magnetically suspended rotor: rot-a-flot
-
Mendler N, Podechtl F, Feil G, etal. Seal-less centrifugal blood pump with magnetically suspended rotor: rot-a-flot. Artif Organs 1995;19:620-624.
-
(1995)
Artif Organs
, vol.19
, pp. 620-624
-
-
Mendler, N.1
Podechtl, F.2
Feil, G.3
-
11
-
-
42049098604
-
Evaluation of oxygenators and centrifugal pumps for long-term pediatric extracorporeal membrane oxygenation
-
Thiara AP, Hoel TN, Kristiansen F, etal. Evaluation of oxygenators and centrifugal pumps for long-term pediatric extracorporeal membrane oxygenation. Perfusion 2007;22:323-326.
-
(2007)
Perfusion
, vol.22
, pp. 323-326
-
-
Thiara, A.P.1
Hoel, T.N.2
Kristiansen, F.3
-
12
-
-
23044472459
-
A polymethylpentene fiber gas exchanger for long-term extracorporeal life support
-
Toomasian JM, Schreiner RJ, Meyer DE, etal. A polymethylpentene fiber gas exchanger for long-term extracorporeal life support. ASAIO J 2005;51:390-397.
-
(2005)
ASAIO J
, vol.51
, pp. 390-397
-
-
Toomasian, J.M.1
Schreiner, R.J.2
Meyer, D.E.3
-
13
-
-
38349098665
-
Extracorporeal membrane oxygenation with a poly-methylpentene oxygenator (Quadrox D). The experience of a single Italian centre in adult patients with refractory cardiogenic shock
-
Formica F, Avalli L, Martino A, etal. Extracorporeal membrane oxygenation with a poly-methylpentene oxygenator (Quadrox D). The experience of a single Italian centre in adult patients with refractory cardiogenic shock. ASAIO J 2008;54:89-94.
-
(2008)
ASAIO J
, vol.54
, pp. 89-94
-
-
Formica, F.1
Avalli, L.2
Martino, A.3
-
14
-
-
2342664194
-
Pump-induced haemolysis: a comparison of short-term ventricular assist devices
-
Bennett M, Horton S, Thuys C, etal. Pump-induced haemolysis: a comparison of short-term ventricular assist devices. Perfusion 2004;19:107-111.
-
(2004)
Perfusion
, vol.19
, pp. 107-111
-
-
Bennett, M.1
Horton, S.2
Thuys, C.3
-
15
-
-
77951897571
-
Mechanical performance comparison between RotaFlow and CentriMag centrifugal blood pumps in an adult ECLS model
-
Guan Y, Su X, McCoach R, etal. Mechanical performance comparison between RotaFlow and CentriMag centrifugal blood pumps in an adult ECLS model. Perfusion 2010;25:71-76.
-
(2010)
Perfusion
, vol.25
, pp. 71-76
-
-
Guan, Y.1
Su, X.2
McCoach, R.3
-
16
-
-
10044244910
-
A new design for a compact centrifugal blood pump with a magnetically levitated rotor
-
Asama J, Shinshi T, Hoshi H, Takatani S, Shimokohbe A. A new design for a compact centrifugal blood pump with a magnetically levitated rotor. ASAIO J 2004;50:550-556.
-
(2004)
ASAIO J
, vol.50
, pp. 550-556
-
-
Asama, J.1
Shinshi, T.2
Hoshi, H.3
Takatani, S.4
Shimokohbe, A.5
-
17
-
-
33845487963
-
Hemolytic performance of a MagLev disposable rotary blood pump (MedTech Dispo): effects of MagLev gap clearance and surface roughness
-
Hoshi H, Asama J, Hijikata W, etal. Hemolytic performance of a MagLev disposable rotary blood pump (MedTech Dispo): effects of MagLev gap clearance and surface roughness. Artif Organs 2006;30:949-954.
-
(2006)
Artif Organs
, vol.30
, pp. 949-954
-
-
Hoshi, H.1
Asama, J.2
Hijikata, W.3
-
18
-
-
47349107910
-
A magnetically levitated centrifugal blood pump with a simple-structured disposable pump head
-
Hijikata W, Shinshi T, Asama J, etal. A magnetically levitated centrifugal blood pump with a simple-structured disposable pump head. Artif Organs 2008;32:531-540.
-
(2008)
Artif Organs
, vol.32
, pp. 531-540
-
-
Hijikata, W.1
Shinshi, T.2
Asama, J.3
-
19
-
-
70349348942
-
Development of a disposable MagLev centrifugal blood pump intended for one-month support in bridge-to-bridge applications: in vitro and initial in vivo evaluation
-
Someya T, Kobayashi M, Waguri S, etal. Development of a disposable MagLev centrifugal blood pump intended for one-month support in bridge-to-bridge applications: in vitro and initial in vivo evaluation. Artif Organs 2009;33:704-713.
-
(2009)
Artif Organs
, vol.33
, pp. 704-713
-
-
Someya, T.1
Kobayashi, M.2
Waguri, S.3
-
20
-
-
77957286512
-
Development of a disposable magnetically levitated centrifugal blood pump (MedTech Dispo) intended for bridge-to-bridge applications-two-week in vivo evaluation
-
Nagaoka E, Someya T, Kitao T, etal. Development of a disposable magnetically levitated centrifugal blood pump (MedTech Dispo) intended for bridge-to-bridge applications-two-week in vivo evaluation. Artif Organs 2010;34:778-783.
-
(2010)
Artif Organs
, vol.34
, pp. 778-783
-
-
Nagaoka, E.1
Someya, T.2
Kitao, T.3
-
21
-
-
0346788752
-
In vitro and ex vivo blood compatibility study of 2-methacryloyloxyethyl phosphorylcholine (MPC) copolymer-coated hemodialysis hollow fibers
-
Iwasaki Y, Nakabayashi N, Ishihara K. In vitro and ex vivo blood compatibility study of 2-methacryloyloxyethyl phosphorylcholine (MPC) copolymer-coated hemodialysis hollow fibers. J Artif Organs 2003;6:260-266.
-
(2003)
J Artif Organs
, vol.6
, pp. 260-266
-
-
Iwasaki, Y.1
Nakabayashi, N.2
Ishihara, K.3
-
22
-
-
0029111918
-
Clinical experience with BioMedicus centrifugal ventricular support in 172 patients
-
Noon GP, Ball JW Jr, Papaconstantinou HT. Clinical experience with BioMedicus centrifugal ventricular support in 172 patients. Artif Organs 1995;19:756-760.
-
(1995)
Artif Organs
, vol.19
, pp. 756-760
-
-
Noon, G.P.1
Ball Jr, J.W.2
Papaconstantinou, H.T.3
-
23
-
-
0030271403
-
Centrifugal pump and heparin coating improves cardiopulmonary bypass biocompatibility
-
Moen O, Fosse E, Dregelid E, etal. Centrifugal pump and heparin coating improves cardiopulmonary bypass biocompatibility. Ann Thorac Surg 1996;62:1134-1140.
-
(1996)
Ann Thorac Surg
, vol.62
, pp. 1134-1140
-
-
Moen, O.1
Fosse, E.2
Dregelid, E.3
-
24
-
-
79956201420
-
In vivo evaluation of the "TinyPump" as a pediatric left ventricular assist device
-
Kitao T, Ando Y, Yoshikawa M, etal. In vivo evaluation of the "TinyPump" as a pediatric left ventricular assist device. Artif Organs 2011;35:543-553.
-
(2011)
Artif Organs
, vol.35
, pp. 543-553
-
-
Kitao, T.1
Ando, Y.2
Yoshikawa, M.3
-
25
-
-
80051619004
-
One-month biocompatibility evaluation of the pediatric TinyPump in goats
-
Ando Y, Kitao T, Nagaoka E, etal. One-month biocompatibility evaluation of the pediatric TinyPump in goats. Artif Organs 2011;35:813-818.
-
(2011)
Artif Organs
, vol.35
, pp. 813-818
-
-
Ando, Y.1
Kitao, T.2
Nagaoka, E.3
-
26
-
-
10244266347
-
Experimental evaluation of a newly developed ultrathin silicone layer coated hollow fiber oxygenator
-
Shimono T, Shomura Y, Tahara K, etal. Experimental evaluation of a newly developed ultrathin silicone layer coated hollow fiber oxygenator. ASAIO J 1996;42:451-454.
-
(1996)
ASAIO J
, vol.42
, pp. 451-454
-
-
Shimono, T.1
Shomura, Y.2
Tahara, K.3
-
27
-
-
0033966748
-
Biocompatibility of silicone-coated oxygenator in cardiopulmonary bypass
-
Shimamoto A, Kanemitsu S, Fujinaga K, etal. Biocompatibility of silicone-coated oxygenator in cardiopulmonary bypass. Ann Thorac Surg 2000;69:115-120.
-
(2000)
Ann Thorac Surg
, vol.69
, pp. 115-120
-
-
Shimamoto, A.1
Kanemitsu, S.2
Fujinaga, K.3
-
28
-
-
18744384321
-
Extracorporeal membrane oxygenator compatible with centrifugal blood pumps
-
Motomura T, Maeda T, Kawahito S, etal. Extracorporeal membrane oxygenator compatible with centrifugal blood pumps. Artif Organs 2002;26:952-958.
-
(2002)
Artif Organs
, vol.26
, pp. 952-958
-
-
Motomura, T.1
Maeda, T.2
Kawahito, S.3
-
29
-
-
12244303681
-
Long-term ex vivo bovine experiments with the Gyro C1E3 centrifugal blood pump
-
Kawahito S, Maeda T, Motomura T, etal. Long-term ex vivo bovine experiments with the Gyro C1E3 centrifugal blood pump. ASAIO J 2003;49:112-116.
-
(2003)
ASAIO J
, vol.49
, pp. 112-116
-
-
Kawahito, S.1
Maeda, T.2
Motomura, T.3
-
30
-
-
62449196644
-
Extracorporeal Life Support Registry Report 2008: neonatal and pediatric cardiac cases
-
Haines NM, Rycus PT, Zwischenberger JB, etal. Extracorporeal Life Support Registry Report 2008: neonatal and pediatric cardiac cases. ASAIO J 2009;55:111-116.
-
(2009)
ASAIO J
, vol.55
, pp. 111-116
-
-
Haines, N.M.1
Rycus, P.T.2
Zwischenberger, J.B.3
-
31
-
-
64349106997
-
Myocarditis
-
Cooper LT Jr. Myocarditis. N Engl J Med 2009;360:1526-1538.
-
(2009)
N Engl J Med
, vol.360
, pp. 1526-1538
-
-
Cooper Jr, L.T.1
-
32
-
-
74949128123
-
Extracorporeal membrane oxygenation for the support of infants, children, and young adults with acute myocarditis: a review of the Extracorporeal Life Support Organization registry
-
Rajagopal SK, Almond CS, Laussen PC, etal. Extracorporeal membrane oxygenation for the support of infants, children, and young adults with acute myocarditis: a review of the Extracorporeal Life Support Organization registry. Crit Care Med 2010;38:382-387.
-
(2010)
Crit Care Med
, vol.38
, pp. 382-387
-
-
Rajagopal, S.K.1
Almond, C.S.2
Laussen, P.C.3
-
33
-
-
70350018319
-
Efficacy and economic assessment of conventional ventilatory support versus extracorporeal membrane oxygenation for severe adult respiratory failure (CESAR): a multicentre randomized controlled trial
-
Peek GJ, Mugford M, Tiruvoipati R, etal. Efficacy and economic assessment of conventional ventilatory support versus extracorporeal membrane oxygenation for severe adult respiratory failure (CESAR): a multicentre randomized controlled trial. Lancet 2009;374:1351-1363.
-
(2009)
Lancet
, vol.374
, pp. 1351-1363
-
-
Peek, G.J.1
Mugford, M.2
Tiruvoipati, R.3
-
34
-
-
70449721874
-
Extracorporeal membrane oxygenation for 2009 influenza A(H1N1) acute respiratory distress syndrome
-
Davies A, Jones D, Bailey M, etal. Extracorporeal membrane oxygenation for 2009 influenza A(H1N1) acute respiratory distress syndrome. JAMA 2009;302:1888-1895.
-
(2009)
JAMA
, vol.302
, pp. 1888-1895
-
-
Davies, A.1
Jones, D.2
Bailey, M.3
-
35
-
-
0036228972
-
Bilateral lung transplantation with intra- and postoperatively prolonged ECMO support in patients with pulmonary hypertension
-
Pereszlenyi A, Lang G, Steltzer H, etal. Bilateral lung transplantation with intra- and postoperatively prolonged ECMO support in patients with pulmonary hypertension. Eur J Cardiothorac Surg 2002;21:858-863.
-
(2002)
Eur J Cardiothorac Surg
, vol.21
, pp. 858-863
-
-
Pereszlenyi, A.1
Lang, G.2
Steltzer, H.3
-
36
-
-
34247093734
-
Extracorporeal membrane oxygenation for primary graft dysfunction after lung transplantation: analysis of the Extracorporeal Life Support Organization (ELSO) registry
-
Fischer S, Bohn D, Rycus P, etal. Extracorporeal membrane oxygenation for primary graft dysfunction after lung transplantation: analysis of the Extracorporeal Life Support Organization (ELSO) registry. J Heart Lung Transplant 2007;26:472-477.
-
(2007)
J Heart Lung Transplant
, vol.26
, pp. 472-477
-
-
Fischer, S.1
Bohn, D.2
Rycus, P.3
-
37
-
-
77955001122
-
Current status of extracorporeal life support (ECMO) for cardiopulmonary failure
-
Bartlett RH, Gattinoni L. Current status of extracorporeal life support (ECMO) for cardiopulmonary failure. Minerva Anestesiol 2010;76:534-540.
-
(2010)
Minerva Anestesiol
, vol.76
, pp. 534-540
-
-
Bartlett, R.H.1
Gattinoni, L.2
|