메뉴 건너뛰기




Volumn 50, Issue 6, 2004, Pages 550-556

A new design for a compact centrifugal blood pump with a magnetically levitated rotor

Author keywords

[No Author keywords available]

Indexed keywords

FRICTION; MAGNETIC BEARINGS; MAGNETIC LEVITATION; STIFFNESS;

EID: 10044244910     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.MAT.0000144364.62671.5A     Document Type: Article
Times cited : (31)

References (14)
  • 1
    • 0035024802 scopus 로고    scopus 로고
    • Pressure-volume relationship of a pulsatile blood pump for ventricular assist device development
    • Yu YC, Boston R, Simaan MA, Miller PJ, Antaki JF: Pressure-volume relationship of a pulsatile blood pump for ventricular assist device development. ASAIO J 47: 293-301, 2001.
    • (2001) ASAIO J , vol.47 , pp. 293-301
    • Yu, Y.C.1    Boston, R.2    Simaan, M.A.3    Miller, P.J.4    Antaki, J.F.5
  • 2
    • 0036739044 scopus 로고    scopus 로고
    • One piece ultracompact totally implantable electromechanical total artificial heart for permanent use
    • Takatani S, Sakamoto T, Ohuchi K, Nakamura M, Mizuno T, Arai H: One piece ultracompact totally implantable electromechanical total artificial heart for permanent use. ASAIO J 48: 538-545, 2002.
    • (2002) ASAIO J , vol.48 , pp. 538-545
    • Takatani, S.1    Sakamoto, T.2    Ohuchi, K.3    Nakamura, M.4    Mizuno, T.5    Arai, H.6
  • 3
    • 0029142494 scopus 로고
    • Recent studies of the centrifugal blood pumps with a magnetically suspended impeller
    • Akamatsu T, Tsukiya T, Nishimura K, Chang-Hee P, Nakazeki T: Recent studies of the centrifugal blood pumps with a magnetically suspended impeller. Artif Organs 19: 631-634, 1995.
    • (1995) Artif Organs , vol.19 , pp. 631-634
    • Akamatsu, T.1    Tsukiya, T.2    Nishimura, K.3    Chang-Hee, P.4    Nakazeki, T.5
  • 4
    • 0034823946 scopus 로고    scopus 로고
    • Development status of Terumo implantable left ventricular assist system
    • Nojiri C, Kijima T, Maekawa J, et al: Development status of Terumo implantable left ventricular assist system. Artif Organs 25: 411-413, 2001.
    • (2001) Artif Organs , vol.25 , pp. 411-413
    • Nojiri, C.1    Kijima, T.2    Maekawa, J.3
  • 5
    • 0030848184 scopus 로고    scopus 로고
    • New mechanism to reduce the size of the monopivot magnetic suspension blood pump: Direct drive mechanism
    • Yamane T, Nishida M, Kijima T, Maekawa J: New mechanism to reduce the size of the monopivot magnetic suspension blood pump: Direct drive mechanism. Artif Organs 21: 620-624, 1997.
    • (1997) Artif Organs , vol.21 , pp. 620-624
    • Yamane, T.1    Nishida, M.2    Kijima, T.3    Maekawa, J.4
  • 6
    • 0033919464 scopus 로고    scopus 로고
    • Development of a Compact, sealless, tripod supported, magnetically driven centrifugal blood pump
    • Yuhki A, Nogawa M, Takatani S: Development of a Compact, sealless, tripod supported, magnetically driven centrifugal blood pump. Artif Organs 24: 501-505, 2000.
    • (2000) Artif Organs , vol.24 , pp. 501-505
    • Yuhki, A.1    Nogawa, M.2    Takatani, S.3
  • 7
    • 0030055691 scopus 로고    scopus 로고
    • Proto-type of continuous flow ventricular assist device supported on magnetic bearings
    • Allaire PE, Kim HC, Maslen EH, Olsen DB, Bearnson GB: Proto-type of continuous flow ventricular assist device supported on magnetic bearings. Artif Organs 20: 582-590, 1996.
    • (1996) Artif Organs , vol.20 , pp. 582-590
    • Allaire, P.E.1    Kim, H.C.2    Maslen, E.H.3    Olsen, D.B.4    Bearnson, G.B.5
  • 8
    • 0030057896 scopus 로고    scopus 로고
    • A magnetically suspended and hydrostatically stabilized centrifugal blood pump
    • Hart MR, Filipenco GV, Kung TVR: A magnetically suspended and hydrostatically stabilized centrifugal blood pump. Artif Organs 20: 591-596, 1996.
    • (1996) Artif Organs , vol.20 , pp. 591-596
    • Hart, M.R.1    Filipenco, G.V.2    Kung, T.V.R.3
  • 11
    • 0034934514 scopus 로고    scopus 로고
    • HeartMate III: Pump design for a centrifugal LVAD with a magnetically levitated rotor
    • Bourque K, Gernes DB, Loree II HM, et al: HeartMate III: Pump design for a centrifugal LVAD with a magnetically levitated rotor. ASAIO J 47: 401-405, 2001.
    • (2001) ASAIO J , vol.47 , pp. 401-405
    • Bourque, K.1    Gernes, D.B.2    Loree II, H.M.3
  • 13
    • 0018983463 scopus 로고
    • Design of permanent multipole magnets with oriented rare earth cobalt material
    • Halbach K: Design of permanent multipole magnets with oriented rare earth cobalt material. Nucl Instr Methods 169, 1-10, 1980.
    • (1980) Nucl Instr Methods , vol.169 , pp. 1-10
    • Halbach, K.1
  • 14
    • 0031946595 scopus 로고    scopus 로고
    • Washout hole flow measurement for the development of a centrifugal blood pump
    • Nishida M, Yamane T, Asztalos B: Washout hole flow measurement for the development of a centrifugal blood pump. Artif Organs 22: 386-392, 1998.
    • (1998) Artif Organs , vol.22 , pp. 386-392
    • Nishida, M.1    Yamane, T.2    Asztalos, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.