메뉴 건너뛰기




Volumn 33, Issue 9, 2009, Pages 704-713

Development of a disposable maglev centrifugal blood pump intended for one-month support in bridge-to-bridge applications: In vitro and initial in vivo evaluation

Author keywords

Antithrombogenicity; Circulatory support; Disposable centrifugal blood pump; Hemolysis; Magnetic levitation

Indexed keywords

BIOCOMPATIBILITY; DEGREES OF FREEDOM (MECHANICS); MAGNETIC COUPLINGS; MAGNETIC LEVITATION; MAGNETIC LEVITATION VEHICLES; PUMPS; SUSPENSIONS (COMPONENTS);

EID: 70349348942     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2009.00900.x     Document Type: Article
Times cited : (24)

References (24)
  • 1
    • 0030041697 scopus 로고    scopus 로고
    • Bio-medicus centrifugal ventricular support for postcardiotomy cardiac failure: A review of 129 cases
    • Noon GP, Ball JW, Short HD. Bio-medicus centrifugal ventricular support for postcardiotomy cardiac failure: a review of 129 cases. Ann Thorac Surg 1996 61 : 291 295.
    • (1996) Ann Thorac Surg , vol.61 , pp. 291-295
    • Noon, G.P.1    Ball, J.W.2    Short, H.D.3
  • 3
    • 0026727055 scopus 로고
    • Postcardiotomy centrifugal mechanical ventricular support
    • Golding LAR, Crouch RD, Stewart RW, et al. Postcardiotomy centrifugal mechanical ventricular support. Ann Thorac Surg 1992 54 : 1059 1064.
    • (1992) Ann Thorac Surg , vol.54 , pp. 1059-1064
    • Golding, L.A.R.1    Crouch, R.D.2    Stewart, R.W.3
  • 4
    • 0035846606 scopus 로고    scopus 로고
    • Reversal of cardiogenic shock by percutaneous left atrial-to-femoral arterial bypass assistance
    • Thiele H, Lauer B, Hambrecht R, Boudriot E, Cohen HA, Schuler G. Reversal of cardiogenic shock by percutaneous left atrial-to-femoral arterial bypass assistance. Circulation 2001 104 : 2917 2922.
    • (2001) Circulation , vol.104 , pp. 2917-2922
    • Thiele, H.1    Lauer, B.2    Hambrecht, R.3    Boudriot, E.4    Cohen, H.A.5    Schuler, G.6
  • 5
    • 50049115669 scopus 로고    scopus 로고
    • Fulminant myocarditis treated with percutaneous cardiopulmonary support system (PCPS)
    • Oshima K, Kunimoto F, Hinohara H, et al. Fulminant myocarditis treated with percutaneous cardiopulmonary support system (PCPS). Ann Thorac Cardiovasc Surg 2008 14 : 75 80.
    • (2008) Ann Thorac Cardiovasc Surg , vol.14 , pp. 75-80
    • Oshima, K.1    Kunimoto, F.2    Hinohara, H.3
  • 6
    • 0036234135 scopus 로고    scopus 로고
    • National survey of fulminant myocarditis in Japan - Therapeutic guidelines and long-term prognosis of using percutaneous cardiopulmonary support for fulminant myocarditis (special report from a scientific committee)
    • Aoyama N, Izumi T, Hiramori K, et al. National survey of fulminant myocarditis in Japan - Therapeutic guidelines and long-term prognosis of using percutaneous cardiopulmonary support for fulminant myocarditis (special report from a scientific committee). Circ J 2002 66 : 133 144.
    • (2002) Circ J , vol.66 , pp. 133-144
    • Aoyama, N.1    Izumi, T.2    Hiramori, K.3
  • 7
    • 33646243597 scopus 로고    scopus 로고
    • Third-generation blood pumps with mechanical noncontact magnetic bearings
    • Hoshi H, Shinshi T, Takatani S. Third-generation blood pumps with mechanical noncontact magnetic bearings. Artif Organs 2006 30 : 324 338.
    • (2006) Artif Organs , vol.30 , pp. 324-338
    • Hoshi, H.1    Shinshi, T.2    Takatani, S.3
  • 8
    • 33750566081 scopus 로고    scopus 로고
    • The DuraHeart VAD, a magnetically levitated centrifugal pump - The University of Vienna bridge-to-transplant experience
    • Nishinaka T, Schima H, Roethy W, et al. The DuraHeart VAD, a magnetically levitated centrifugal pump - The University of Vienna bridge-to-transplant experience. Circ J 2006 70 : 1421 1425.
    • (2006) Circ J , vol.70 , pp. 1421-1425
    • Nishinaka, T.1    Schima, H.2    Roethy, W.3
  • 11
    • 44149116182 scopus 로고    scopus 로고
    • A prospective, multicenter trial of the VentrAssist left ventricular assist device for bridge to transplant: Safety and efficacy
    • Esmore D, Kaye D, Spratt P, et al. A prospective, multicenter trial of the VentrAssist left ventricular assist device for bridge to transplant: safety and efficacy. J Heart Lung Transplant 2008 27 : 579 588.
    • (2008) J Heart Lung Transplant , vol.27 , pp. 579-588
    • Esmore, D.1    Kaye, D.2    Spratt, P.3
  • 12
    • 10044244910 scopus 로고    scopus 로고
    • A new design for a compact centrifugal blood pump with a magnetically levitated rotor
    • Asama J, Shinshi T, Hoshi H, Takatani S, Shimokohbe A. A new design for a compact centrifugal blood pump with a magnetically levitated rotor. ASAIO J 2004 50 : 550 556.
    • (2004) ASAIO J , vol.50 , pp. 550-556
    • Asama, J.1    Shinshi, T.2    Hoshi, H.3    Takatani, S.4    Shimokohbe, A.5
  • 14
    • 27744443390 scopus 로고    scopus 로고
    • Disposable magnetically levitated centrifugal blood pump: Design and in vitro performance
    • Hoshi H, Asama J, Shinshi T, et al. Disposable magnetically levitated centrifugal blood pump: design and in vitro performance. Artif Organs 2005 29 : 520 526.
    • (2005) Artif Organs , vol.29 , pp. 520-526
    • Hoshi, H.1    Asama, J.2    Shinshi, T.3
  • 15
    • 33845487963 scopus 로고    scopus 로고
    • Hemolytic performance of a MagLev disposable rotary blood pump (MedTech Dispo): Effects of MagLev gap clearance and surface roughness
    • Hoshi H, Asama J, Hijikata W, et al. Hemolytic performance of a MagLev disposable rotary blood pump (MedTech Dispo): effects of MagLev gap clearance and surface roughness. Artif Organs 2006 30 : 949 954.
    • (2006) Artif Organs , vol.30 , pp. 949-954
    • Hoshi, H.1    Asama, J.2    Hijikata, W.3
  • 16
    • 33645011359 scopus 로고    scopus 로고
    • A compact highly efficient and low hemolytic centrifugal blood pump with a magnetically levitated impeller
    • Asama J, Shinshi T, Hoshi H, Takatani S, Shimokohbe A. A compact highly efficient and low hemolytic centrifugal blood pump with a magnetically levitated impeller. Artif Organs 2006 30 : 160 167.
    • (2006) Artif Organs , vol.30 , pp. 160-167
    • Asama, J.1    Shinshi, T.2    Hoshi, H.3    Takatani, S.4    Shimokohbe, A.5
  • 17
    • 47349107910 scopus 로고    scopus 로고
    • A magnetically levitated centrifugal blood pump with a simple-structured disposable pump head
    • Hijikata W, Shinshi T, Asama J, et al. A magnetically levitated centrifugal blood pump with a simple-structured disposable pump head. Artif Organs 2008 32 : 531 540.
    • (2008) Artif Organs , vol.32 , pp. 531-540
    • Hijikata, W.1    Shinshi, T.2    Asama, J.3
  • 18
    • 12844279262 scopus 로고    scopus 로고
    • Quantification of the secondary flow in a radial coupled centrifugal blood pump based on particle tracking velocimetry
    • Watanabe N, Masuda T, Iida T, Kataoka H, Fujimoto T, Takatani S. Quantification of the secondary flow in a radial coupled centrifugal blood pump based on particle tracking velocimetry. Artif Organs 2005 29 : 26 35.
    • (2005) Artif Organs , vol.29 , pp. 26-35
    • Watanabe, N.1    Masuda, T.2    Iida, T.3    Kataoka, H.4    Fujimoto, T.5    Takatani, S.6
  • 19
    • 0025229068 scopus 로고
    • Preparation of phospholipid polymers and their properties as polymer hydrogel membranes
    • Ishihara K, Ueda T, Nakabayashi N. Preparation of phospholipid polymers and their properties as polymer hydrogel membranes. Polym J 1990 22 : 355 360.
    • (1990) Polym J , vol.22 , pp. 355-360
    • Ishihara, K.1    Ueda, T.2    Nakabayashi, N.3
  • 20
    • 70349334253 scopus 로고    scopus 로고
    • Standard practice for assessment of hemolysis in continuous flow blood pumps
    • ASTM Committee. F1844-97; 13.01
    • ASTM Committee. Standard practice for assessment of hemolysis in continuous flow blood pumps, in Annual Books of ASTM Standards, F1844-97; 13.01, 1998.
    • (1998) Annual Books of ASTM Standards
  • 22
    • 0032708285 scopus 로고    scopus 로고
    • Inhibition of fibroblast cell adhesion on substrate by coating with 2-methacryloyloxyethyl phosphorylcholine polymers
    • Ishihara K, Ishikawa E, Iwasaki Y, Nakabayashi N. Inhibition of fibroblast cell adhesion on substrate by coating with 2-methacryloyloxyethyl phosphorylcholine polymers. J Biomat Sci Polym E 1999 10 : 1047 1061.
    • (1999) J Biomat Sci Polym e , vol.10 , pp. 1047-1061
    • Ishihara, K.1    Ishikawa, E.2    Iwasaki, Y.3    Nakabayashi, N.4
  • 24
    • 33947190918 scopus 로고    scopus 로고
    • Preclinical biocompatibility assessment of the EVAHEART ventricular assist device: Coating comparison and platelet activation
    • Snyder TA, Tsukui H, Kihara S, et al. Preclinical biocompatibility assessment of the EVAHEART ventricular assist device: coating comparison and platelet activation. J Biomed Mater Res A 2007 81A : 85 92.
    • (2007) J Biomed Mater Res A , vol.81 , pp. 85-92
    • Snyder, T.A.1    Tsukui, H.2    Kihara, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.