1
-
-
0030041697
-
Bio-medicus centrifugal ventricular support for postcardiotomy cardiac failure: A review of 129 cases
-
Noon GP, Ball JW, Short HD. Bio-medicus centrifugal ventricular support for postcardiotomy cardiac failure: a review of 129 cases. Ann Thorac Surg 1996 61 : 291 295.
-
(1996)
Ann Thorac Surg
, vol.61
, pp. 291-295
-
-
Noon, G.P.1
Ball, J.W.2
Short, H.D.3
-
2
-
-
0026448677
-
Extracorporeal membrane-oxygenation in children after cardiac-surgery
-
Raithel SC, Pennington DG, Boegner E, Fiore A, Weber TR. Extracorporeal membrane-oxygenation in children after cardiac-surgery. Circulation 1992 86 : 305 310.
-
(1992)
Circulation
, vol.86
, pp. 305-310
-
-
Raithel, S.C.1
Pennington, D.G.2
Boegner, E.3
Fiore, A.4
Weber, T.R.5
-
3
-
-
0026727055
-
Postcardiotomy centrifugal mechanical ventricular support
-
Golding LAR, Crouch RD, Stewart RW, et al. Postcardiotomy centrifugal mechanical ventricular support. Ann Thorac Surg 1992 54 : 1059 1064.
-
(1992)
Ann Thorac Surg
, vol.54
, pp. 1059-1064
-
-
Golding, L.A.R.1
Crouch, R.D.2
Stewart, R.W.3
-
4
-
-
0035846606
-
Reversal of cardiogenic shock by percutaneous left atrial-to-femoral arterial bypass assistance
-
Thiele H, Lauer B, Hambrecht R, Boudriot E, Cohen HA, Schuler G. Reversal of cardiogenic shock by percutaneous left atrial-to-femoral arterial bypass assistance. Circulation 2001 104 : 2917 2922.
-
(2001)
Circulation
, vol.104
, pp. 2917-2922
-
-
Thiele, H.1
Lauer, B.2
Hambrecht, R.3
Boudriot, E.4
Cohen, H.A.5
Schuler, G.6
-
5
-
-
50049115669
-
Fulminant myocarditis treated with percutaneous cardiopulmonary support system (PCPS)
-
Oshima K, Kunimoto F, Hinohara H, et al. Fulminant myocarditis treated with percutaneous cardiopulmonary support system (PCPS). Ann Thorac Cardiovasc Surg 2008 14 : 75 80.
-
(2008)
Ann Thorac Cardiovasc Surg
, vol.14
, pp. 75-80
-
-
Oshima, K.1
Kunimoto, F.2
Hinohara, H.3
-
6
-
-
0036234135
-
National survey of fulminant myocarditis in Japan - Therapeutic guidelines and long-term prognosis of using percutaneous cardiopulmonary support for fulminant myocarditis (special report from a scientific committee)
-
Aoyama N, Izumi T, Hiramori K, et al. National survey of fulminant myocarditis in Japan - Therapeutic guidelines and long-term prognosis of using percutaneous cardiopulmonary support for fulminant myocarditis (special report from a scientific committee). Circ J 2002 66 : 133 144.
-
(2002)
Circ J
, vol.66
, pp. 133-144
-
-
Aoyama, N.1
Izumi, T.2
Hiramori, K.3
-
7
-
-
33646243597
-
Third-generation blood pumps with mechanical noncontact magnetic bearings
-
Hoshi H, Shinshi T, Takatani S. Third-generation blood pumps with mechanical noncontact magnetic bearings. Artif Organs 2006 30 : 324 338.
-
(2006)
Artif Organs
, vol.30
, pp. 324-338
-
-
Hoshi, H.1
Shinshi, T.2
Takatani, S.3
-
8
-
-
33750566081
-
The DuraHeart VAD, a magnetically levitated centrifugal pump - The University of Vienna bridge-to-transplant experience
-
Nishinaka T, Schima H, Roethy W, et al. The DuraHeart VAD, a magnetically levitated centrifugal pump - The University of Vienna bridge-to-transplant experience. Circ J 2006 70 : 1421 1425.
-
(2006)
Circ J
, vol.70
, pp. 1421-1425
-
-
Nishinaka, T.1
Schima, H.2
Roethy, W.3
-
9
-
-
33646246420
-
HeartQuest ventricular assist device magnetically levitated centrifugal blood pump
-
Bearnson GB, Jacobs GB, Kirk J, Khanwilkar PS, Nelson KE, Long JW. HeartQuest ventricular assist device magnetically levitated centrifugal blood pump. Artif Organs 2006 30 : 339 346.
-
(2006)
Artif Organs
, vol.30
, pp. 339-346
-
-
Bearnson, G.B.1
Jacobs, G.B.2
Kirk, J.3
Khanwilkar, P.S.4
Nelson, K.E.5
Long, J.W.6
-
10
-
-
43949122940
-
First successful bridge to myocardial recovery with a heartware HVAD
-
Wood C, Maiorana A, Larbalestier R, Lovett M, Green G, O'Driscoll G First successful bridge to myocardial recovery with a heartware HVAD. J Heart Lung Transplant 2008 27 : 695 697.
-
(2008)
J Heart Lung Transplant
, vol.27
, pp. 695-697
-
-
Wood, C.1
Maiorana, A.2
Larbalestier, R.3
Lovett, M.4
Green, G.5
O'Driscoll, G.6
-
11
-
-
44149116182
-
A prospective, multicenter trial of the VentrAssist left ventricular assist device for bridge to transplant: Safety and efficacy
-
Esmore D, Kaye D, Spratt P, et al. A prospective, multicenter trial of the VentrAssist left ventricular assist device for bridge to transplant: safety and efficacy. J Heart Lung Transplant 2008 27 : 579 588.
-
(2008)
J Heart Lung Transplant
, vol.27
, pp. 579-588
-
-
Esmore, D.1
Kaye, D.2
Spratt, P.3
-
12
-
-
10044244910
-
A new design for a compact centrifugal blood pump with a magnetically levitated rotor
-
Asama J, Shinshi T, Hoshi H, Takatani S, Shimokohbe A. A new design for a compact centrifugal blood pump with a magnetically levitated rotor. ASAIO J 2004 50 : 550 556.
-
(2004)
ASAIO J
, vol.50
, pp. 550-556
-
-
Asama, J.1
Shinshi, T.2
Hoshi, H.3
Takatani, S.4
Shimokohbe, A.5
-
13
-
-
12844273500
-
Magnetically suspended centrifugal blood pump with a radial magnetic driver
-
DOI 10.1097/01.MAT.0000151148.72891.55
-
Hoshi H, Katakoa K, Ohuchi K, et al. Magnetically suspended centrifugal blood pump with a radial magnetic driver. ASAIO J 2005 51 : 60 4. (Pubitemid 40165253)
-
(2005)
ASAIO Journal
, vol.51
, Issue.1
, pp. 60-64
-
-
Hoshi, H.1
Katakoa, K.2
Ohuchi, K.3
Asama, J.-I.4
Shinshi, T.5
Shimokohbe, A.6
Takatani, S.7
-
14
-
-
27744443390
-
Disposable magnetically levitated centrifugal blood pump: Design and in vitro performance
-
Hoshi H, Asama J, Shinshi T, et al. Disposable magnetically levitated centrifugal blood pump: design and in vitro performance. Artif Organs 2005 29 : 520 526.
-
(2005)
Artif Organs
, vol.29
, pp. 520-526
-
-
Hoshi, H.1
Asama, J.2
Shinshi, T.3
-
15
-
-
33845487963
-
Hemolytic performance of a MagLev disposable rotary blood pump (MedTech Dispo): Effects of MagLev gap clearance and surface roughness
-
Hoshi H, Asama J, Hijikata W, et al. Hemolytic performance of a MagLev disposable rotary blood pump (MedTech Dispo): effects of MagLev gap clearance and surface roughness. Artif Organs 2006 30 : 949 954.
-
(2006)
Artif Organs
, vol.30
, pp. 949-954
-
-
Hoshi, H.1
Asama, J.2
Hijikata, W.3
-
16
-
-
33645011359
-
A compact highly efficient and low hemolytic centrifugal blood pump with a magnetically levitated impeller
-
Asama J, Shinshi T, Hoshi H, Takatani S, Shimokohbe A. A compact highly efficient and low hemolytic centrifugal blood pump with a magnetically levitated impeller. Artif Organs 2006 30 : 160 167.
-
(2006)
Artif Organs
, vol.30
, pp. 160-167
-
-
Asama, J.1
Shinshi, T.2
Hoshi, H.3
Takatani, S.4
Shimokohbe, A.5
-
17
-
-
47349107910
-
A magnetically levitated centrifugal blood pump with a simple-structured disposable pump head
-
Hijikata W, Shinshi T, Asama J, et al. A magnetically levitated centrifugal blood pump with a simple-structured disposable pump head. Artif Organs 2008 32 : 531 540.
-
(2008)
Artif Organs
, vol.32
, pp. 531-540
-
-
Hijikata, W.1
Shinshi, T.2
Asama, J.3
-
18
-
-
12844279262
-
Quantification of the secondary flow in a radial coupled centrifugal blood pump based on particle tracking velocimetry
-
Watanabe N, Masuda T, Iida T, Kataoka H, Fujimoto T, Takatani S. Quantification of the secondary flow in a radial coupled centrifugal blood pump based on particle tracking velocimetry. Artif Organs 2005 29 : 26 35.
-
(2005)
Artif Organs
, vol.29
, pp. 26-35
-
-
Watanabe, N.1
Masuda, T.2
Iida, T.3
Kataoka, H.4
Fujimoto, T.5
Takatani, S.6
-
19
-
-
0025229068
-
Preparation of phospholipid polymers and their properties as polymer hydrogel membranes
-
Ishihara K, Ueda T, Nakabayashi N. Preparation of phospholipid polymers and their properties as polymer hydrogel membranes. Polym J 1990 22 : 355 360.
-
(1990)
Polym J
, vol.22
, pp. 355-360
-
-
Ishihara, K.1
Ueda, T.2
Nakabayashi, N.3
-
20
-
-
70349334253
-
Standard practice for assessment of hemolysis in continuous flow blood pumps
-
ASTM Committee. F1844-97; 13.01
-
ASTM Committee. Standard practice for assessment of hemolysis in continuous flow blood pumps, in Annual Books of ASTM Standards, F1844-97; 13.01, 1998.
-
(1998)
Annual Books of ASTM Standards
-
-
-
21
-
-
0025472071
-
Reduced thrombogenicity of polymers having phospholipid polar groups
-
Ishihara K, Aragaki R, Ueda T, Watenabe A, Nakabayashi N. Reduced thrombogenicity of polymers having phospholipid polar groups. J Biomed Mater Res 1990 24 : 1069 1077.
-
(1990)
J Biomed Mater Res
, vol.24
, pp. 1069-1077
-
-
Ishihara, K.1
Aragaki, R.2
Ueda, T.3
Watenabe, A.4
Nakabayashi, N.5
-
22
-
-
0032708285
-
Inhibition of fibroblast cell adhesion on substrate by coating with 2-methacryloyloxyethyl phosphorylcholine polymers
-
Ishihara K, Ishikawa E, Iwasaki Y, Nakabayashi N. Inhibition of fibroblast cell adhesion on substrate by coating with 2-methacryloyloxyethyl phosphorylcholine polymers. J Biomat Sci Polym E 1999 10 : 1047 1061.
-
(1999)
J Biomat Sci Polym e
, vol.10
, pp. 1047-1061
-
-
Ishihara, K.1
Ishikawa, E.2
Iwasaki, Y.3
Nakabayashi, N.4
-
23
-
-
0344838635
-
In vivo evaluation of a MPC polymer coated continuous flow left ventricular assist system
-
DOI 10.1046/j.1525-1594.2003.t01-2-06993.x
-
Kihara S, Yamazaki K, Litwak KN, et al. In vivo evaluation of a MPC polymer coated continuous flow left ventricular assist system. Artif Organs 2003 27 : 188 192. (Pubitemid 36269402)
-
(2003)
Artificial Organs
, vol.27
, Issue.2
, pp. 188-192
-
-
Kihara, S.1
Yamazaki, K.2
Litwak, K.N.3
Litwak, P.4
Kameneva, M.V.5
Ushiyama, H.6
Tokuno, T.7
Borzelleca, D.C.8
Umezu, M.9
Tomioka, J.10
Tagusari, O.11
Akimoto, T.12
Koyanagi, H.13
Kurosawa, H.14
Kormos, R.L.15
Griffith, B.P.16
-
24
-
-
33947190918
-
Preclinical biocompatibility assessment of the EVAHEART ventricular assist device: Coating comparison and platelet activation
-
Snyder TA, Tsukui H, Kihara S, et al. Preclinical biocompatibility assessment of the EVAHEART ventricular assist device: coating comparison and platelet activation. J Biomed Mater Res A 2007 81A : 85 92.
-
(2007)
J Biomed Mater Res A
, vol.81
, pp. 85-92
-
-
Snyder, T.A.1
Tsukui, H.2
Kihara, S.3
|