메뉴 건너뛰기




Volumn 24, Issue 7, 2013, Pages 828-836

Modeling and experimental validation of unimorph piezoelectric cymbal design in energy harvesting

Author keywords

cyclic load; Cymbal structure; energy harvesting; piezoelectric; truncated conical shell; unimorph

Indexed keywords

EXPERIMENTAL VALIDATIONS; GEOMETRIC PARAMETER; LEAD ZIRCONATE TITANATE; LEAD ZIRCONATE TITANATE CYMBALS; OPEN-CIRCUIT OUTPUT VOLTAGES; PIEZOELECTRIC; TRUNCATED CONICAL SHELL; UNIMORPH;

EID: 84876794852     PISSN: 1045389X     EISSN: 15308138     Source Type: Journal    
DOI: 10.1177/1045389X12463459     Document Type: Conference Paper
Times cited : (44)

References (21)
  • 3
    • 33644779713 scopus 로고    scopus 로고
    • Tibial forces measured in vivo after total knee arthroplasty
    • D'Lima DD, Patil S, Steklov N, et al. Tibial forces measured in vivo after total knee arthroplasty. Journal of Arthroplasty. 2006 ; 21 (2). 255-262
    • (2006) Journal of Arthroplasty , vol.21 , Issue.2 , pp. 255-262
    • D'Lima, D.D.1    Patil, S.2    Steklov, N.3
  • 5
    • 0004048477 scopus 로고
    • New York, USA: The Institute of Electrical and Electronics Engineers;
    • IEEE Standards on Piezoelectricity. New York, USA: The Institute of Electrical and Electronics Engineers ; 1978 :
    • (1978) IEEE Standards on Piezoelectricity
  • 6
    • 9144256385 scopus 로고    scopus 로고
    • Energy harvesting using a piezoelectric cymbal transducer in dynamic environment
    • Kim HW, Bartra A, Priya S, et al. Energy harvesting using a piezoelectric cymbal transducer in dynamic environment. Japanese Journal of Applied Physics. 2004 ; 43 (9A). 6178-6183
    • (2004) Japanese Journal of Applied Physics , vol.43 , Issue.9 A , pp. 6178-6183
    • Kim, H.W.1    Bartra, A.2    Priya, S.3
  • 7
    • 33746814442 scopus 로고    scopus 로고
    • Modeling of piezoelectric energy harvesting using cymbal transducers
    • Kim HW, Priya S, Uchino K. Modeling of piezoelectric energy harvesting using cymbal transducers. Japanese Journal of Applied Physics. 2006 ; 45 (7). 5836-5840
    • (2006) Japanese Journal of Applied Physics , vol.45 , Issue.7 , pp. 5836-5840
    • Kim, H.W.1    Priya, S.2    Uchino, K.3
  • 8
    • 23944492934 scopus 로고    scopus 로고
    • Piezoelectric energy harvesting under high pre-stressed cyclic vibrations
    • Kim HW, Priya S, Uchino K, et al. Piezoelectric energy harvesting under high pre-stressed cyclic vibrations. Journal of Electroceramics. 2005 ; 15: 27-34
    • (2005) Journal of Electroceramics , vol.15 , pp. 27-34
    • Kim, H.W.1    Priya, S.2    Uchino, K.3
  • 9
    • 33744537108 scopus 로고    scopus 로고
    • A multiaxial force-sensing implantable tibial prosthesis
    • Kirking B, Krevolin J, Townsend C, et al. A multiaxial force-sensing implantable tibial prosthesis. Journal of Biomechanics. 2006 ; 39: 1744-1751
    • (2006) Journal of Biomechanics , vol.39 , pp. 1744-1751
    • Kirking, B.1    Krevolin, J.2    Townsend, C.3
  • 10
    • 0037446344 scopus 로고    scopus 로고
    • Analytical analysis of a circular PZT actuator for valveless micropump
    • Li S, Chen S. Analytical analysis of a circular PZT actuator for valveless micropump. Sensors and Actuators A: Physical. 2003 ; 104: 151-161
    • (2003) Sensors and Actuators A: Physical , vol.104 , pp. 151-161
    • Li, S.1    Chen, S.2
  • 11
    • 10444261188 scopus 로고    scopus 로고
    • The influence of design, materials and kinematics on the in vitro wear of total knee replacements
    • McEwen HMJ, Barnett PI, Bell CJ, et al. The influence of design, materials and kinematics on the in vitro wear of total knee replacements. Journal of Biomechanics. 2005 ; 38: 357-365
    • (2005) Journal of Biomechanics , vol.38 , pp. 357-365
    • McEwen, H.M.J.1    Barnett, P.I.2    Bell, C.J.3
  • 13
    • 68549125473 scopus 로고    scopus 로고
    • Theoretical analysis of energy harvesting performance for unimorph piezoelectric benders with interdigitated electrodes
    • Mo C, Kim S, Clark WW. Theoretical analysis of energy harvesting performance for unimorph piezoelectric benders with interdigitated electrodes. Smart Materials and Structures. 2009 ; 18 (5). 055017
    • (2009) Smart Materials and Structures , vol.18 , Issue.5 , pp. 055017
    • Mo, C.1    Kim, S.2    Clark, W.W.3
  • 14
    • 76649106799 scopus 로고    scopus 로고
    • Analysis of piezoelectric circular diaphragm energy harvesters for use in a pressure fluctuating system
    • Mo C, Radziemski LJ, Clark WW. Analysis of piezoelectric circular diaphragm energy harvesters for use in a pressure fluctuating system. Smart Materials and Structures. 2010a ; 19 (2). 025016
    • (2010) Smart Materials and Structures , vol.19 , Issue.2 , pp. 025016
    • Mo, C.1    Radziemski, L.J.2    Clark, W.W.3
  • 15
    • 77953798193 scopus 로고    scopus 로고
    • Experimental validation of energy harvesting performance for pressure-loaded piezoelectric circular diaphragms
    • Mo C, Radziemski LJ, Clark WW. Experimental validation of energy harvesting performance for pressure-loaded piezoelectric circular diaphragms. Smart Materials and Structures. 2010b ; 19 (2). 075010
    • (2010) Smart Materials and Structures , vol.19 , Issue.2 , pp. 075010
    • Mo, C.1    Radziemski, L.J.2    Clark, W.W.3
  • 16
    • 0014698584 scopus 로고
    • The mechanics of the knee joint in relation to normal walking
    • Morrison JB. The mechanics of the knee joint in relation to normal walking. Journal of Biomechanics. 1970 ; 3 (1). 51-61
    • (1970) Journal of Biomechanics , vol.3 , Issue.1 , pp. 51-61
    • Morrison, J.B.1
  • 18
    • 27144547214 scopus 로고    scopus 로고
    • The use of piezoelectric ceramics for electric power generation within orthopedic implants
    • Platt SR, Farritor S, Garvin K, et al. The use of piezoelectric ceramics for electric power generation within orthopedic implants. IEEE/ASME Transactions on Mechatronics. 2005a ; 10 (4). 455-461
    • (2005) IEEE/ASME Transactions on Mechatronics , vol.10 , Issue.4 , pp. 455-461
    • Platt, S.R.1    Farritor, S.2    Garvin, K.3
  • 19
    • 77950851129 scopus 로고    scopus 로고
    • Finite element analysis of a novel high flexion knee (Ti-UHMWPE) used in total knee arthroplasty
    • Sivarasu S, Lazar M. Finite element analysis of a novel high flexion knee (Ti-UHMWPE) used in total knee arthroplasty. The International Journal of Bioengineering. 2009 ; 4 ( 1 ):
    • (2009) The International Journal of Bioengineering , vol.4 , Issue.1
    • Sivarasu, S.1    Lazar, M.2
  • 20
    • 0004037233 scopus 로고    scopus 로고
    • 1999) Stresses in Plates and Shells. 2nd edn.Boston, MA: McGraw-Hill, Inc. Boston, MA: McGraw-Hill, Inc;
    • Ugural AC Stresses in Plates and Shells. 1999 ) Stresses in Plates and Shells. 2nd edn.Boston, MA: McGraw-Hill, Inc. Boston, MA: McGraw-Hill, Inc ; 1999 :
    • (1999) Stresses in Plates and Shells
    • Ugural, A.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.