-
2
-
-
0024561625
-
In vivo detection of applied electric currents by magnetic resonance imaging
-
2-s2.0-0024561625
-
Joy M. L., Scott G. C., Henkelman R. M., In vivo detection of applied electric currents by magnetic resonance imaging. Magnetic Resonance Imaging 1989 7 1 89 94 2-s2.0-0024561625
-
(1989)
Magnetic Resonance Imaging
, vol.7
, Issue.1
, pp. 89-94
-
-
Joy, M.L.1
Scott, G.C.2
Henkelman, R.M.3
-
3
-
-
0026221249
-
Measurement of nonuniform current density by magnetic resonance
-
DOI 10.1109/42.97586
-
Scott G. C., Joy M. L. G., Armstrong R. L., Henkelman R. M., Measurement of nonuniform current density by magnetic resonance. IEEE Transactions on Medical Imaging 1991 10 3 362 374 2-s2.0-0026221249 10.1109/42.97586 (Pubitemid 21728000)
-
(1991)
IEEE Transactions on Medical Imaging
, vol.10
, Issue.3
, pp. 362-374
-
-
Scott, G.C.1
Joy, M.L.G.2
Armstrong, R.L.3
Henkelman, R.M.4
-
5
-
-
0038644775
-
Reconstruction of conductivity and current density images using only one component of magnetic field measurements
-
DOI 10.1109/TBME.2003.816080
-
Seo J. K., Yoon J. R., Woo E. J., Kwon O., Reconstruction of conductivity and current density images using only one component of magnetic field measurements. IEEE Transactions on Biomedical Engineering 2003 50 9 1121 1124 2-s2.0-0038644775 10.1109/TBME.2003.816080 (Pubitemid 37047562)
-
(2003)
IEEE Transactions on Biomedical Engineering
, vol.50
, Issue.9
, pp. 1121-1124
-
-
Seo, J.K.1
Yoon, J.-R.2
Woo, E.J.3
Kwon, O.4
-
6
-
-
58149302549
-
Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging
-
2-s2.0-58149302549 10.1088/0967-3334/29/10/R01
-
Woo E. J., Seo J. K., Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging. Physiological Measurement 2008 29 10 R1 R26 2-s2.0-58149302549 10.1088/0967-3334/29/10/R01
-
(2008)
Physiological Measurement
, vol.29
, Issue.10
-
-
Woo, E.J.1
Seo, J.K.2
-
7
-
-
78650039779
-
Magnetic resonance electrical impedance tomography (MREIT)
-
2-s2.0-78650039779 10.1137/080742932
-
Seo J. K., Woo E. J., Magnetic resonance electrical impedance tomography (MREIT). SIAM Review 2011 53 1 40 68 2-s2.0-78650039779 10.1137/080742932
-
(2011)
SIAM Review
, vol.53
, Issue.1
, pp. 40-68
-
-
Seo, J.K.1
Woo, E.J.2
-
8
-
-
0025754003
-
Extraction of conductivity and permittivity using magnetic resonance imaging
-
2-s2.0-0025754003 10.1088/0031-9155/36/6/002
-
Haacke E. M., Pepropoulos L. S., Nilges E. W., Wu D. H., Extraction of conductivity and permittivity using magnetic resonance imaging. Physics in Medicine and Biology 1991 36 6 723 734 2-s2.0-0025754003 10.1088/0031-9155/36/6/ 002
-
(1991)
Physics in Medicine and Biology
, vol.36
, Issue.6
, pp. 723-734
-
-
Haacke, E.M.1
Pepropoulos, L.S.2
Nilges, E.W.3
Wu, D.H.4
-
10
-
-
77954683399
-
Determination of electrical conductivity and local SAR via B 1 mapping
-
Katscher U., Voigt T., Findeklee C., Vernickel P., Nehrke K., Dossel O., Determination of electrical conductivity and local SAR via B 1 mapping. IEEE Transactions on Medical Imaging 2009 28 1365 1374
-
(2009)
IEEE Transactions on Medical Imaging
, vol.28
, pp. 1365-1374
-
-
Katscher, U.1
Voigt, T.2
Findeklee, C.3
Vernickel, P.4
Nehrke, K.5
Dossel, O.6
-
11
-
-
79960584785
-
Quantitative conductivity and permittivity imaging of the human brain using electric properties tomography
-
2-s2.0-79960584785 10.1002/mrm.22832
-
Voigt T., Katscher U., Doessel O., Quantitative conductivity and permittivity imaging of the human brain using electric properties tomography. Magnetic Resonance in Medicine 2011 66 2 456 466 2-s2.0-79960584785 10.1002/mrm.22832
-
(2011)
Magnetic Resonance in Medicine
, vol.66
, Issue.2
, pp. 456-466
-
-
Voigt, T.1
Katscher, U.2
Doessel, O.3
-
12
-
-
0027253712
-
Radiofrequency map of an NMR coil by imaging
-
2-s2.0-0027253712 10.1016/0730-725X(93)90078-R
-
Akoka S., Franconi F., Seguin F., Le Pape A., Radiofrequency map of an NMR coil by imaging. Magnetic Resonance Imaging 1993 11 3 437 441 2-s2.0-0027253712 10.1016/0730-725X(93)90078-R
-
(1993)
Magnetic Resonance Imaging
, vol.11
, Issue.3
, pp. 437-441
-
-
Akoka, S.1
Franconi, F.2
Seguin, F.3
Le Pape, A.4
-
13
-
-
0031974199
-
A simple method for investigating the effects of non-uniformity of radiofrequency transmission and radiofrequency reception in MRI
-
Barker G. J., Simmons A., Arridge S. R., Tofts P. S., A simple method for investigating the effects of non-uniformity of radiofrequency transmission and radiofrequency reception in MRI. British Journal of Radiology 1998 71 59 67 2-s2.0-0031974199 (Pubitemid 28058474)
-
(1998)
British Journal of Radiology
, vol.71
, Issue.JAN.
, pp. 59-67
-
-
Barker, G.J.1
Simmons, A.2
Arridge, S.R.3
Tofts, P.S.4
-
15
-
-
33846078031
-
Actual flip-angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radiofrequency field
-
DOI 10.1002/mrm.21120
-
Yarnykh V. L., Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field. Magnetic Resonance in Medicine 2007 57 1 192 200 2-s2.0-33846078031 10.1002/mrm.21120 (Pubitemid 46067949)
-
(2007)
Magnetic Resonance in Medicine
, vol.57
, Issue.1
, pp. 192-200
-
-
Yarnykh, V.L.1
-
16
-
-
77955289545
-
B 1 mapping by Bloch-Siegert shift
-
2-s2.0-77955289545 10.1002/mrm.22357
-
Sacolick L. I., Wiesinger F., Hancu I., Vogel M. W., B 1 mapping by Bloch-Siegert shift. Magnetic Resonance in Medicine 2010 63 5 1315 1322 2-s2.0-77955289545 10.1002/mrm.22357
-
(2010)
Magnetic Resonance in Medicine
, vol.63
, Issue.5
, pp. 1315-1322
-
-
Sacolick, L.I.1
Wiesinger, F.2
Hancu, I.3
Vogel, M.W.4
-
17
-
-
84867890773
-
DREAM-A novel approach for robust, ultrafast, multislice B 1 mapping
-
Nehrke K., Börnert P., DREAM-a novel approach for robust, ultrafast, multislice B 1 mapping. Magnetic Resonance in Medicine 2012 68 1517 1526
-
(2012)
Magnetic Resonance in Medicine
, vol.68
, pp. 1517-1526
-
-
Nehrke, K.1
Börnert, P.2
-
18
-
-
0027081242
-
RF current density imaging in homogeneous media
-
DOI 10.1002/mrm.1910280203
-
Scott G. C., Joy M. L. G., Armstrong R. L., Henkelman R. M., RF current density imaging in homogeneous media. Magnetic Resonance in Medicine 1992 28 2 186 201 2-s2.0-0027081242 10.1002/mrm.1910280203 (Pubitemid 23027661)
-
(1992)
Magnetic Resonance in Medicine
, vol.28
, Issue.2
, pp. 186-201
-
-
Scott, G.C.1
Joy, M.L.G.2
Armstrong, R.L.3
Henkelman, R.M.4
-
19
-
-
0028967742
-
Rotating frame RF current density imaging
-
2-s2.0-0028967742 10.1002/mrm.1910330309
-
Scott G. C., Joy M. L. G., Armstrong R. L., Henkelman R. M., Rotating frame RF current density imaging. Magnetic Resonance in Medicine 1995 33 3 355 369 2-s2.0-0028967742 10.1002/mrm.1910330309
-
(1995)
Magnetic Resonance in Medicine
, vol.33
, Issue.3
, pp. 355-369
-
-
Scott, G.C.1
Joy, M.L.G.2
Armstrong, R.L.3
Henkelman, R.M.4
-
20
-
-
67649546990
-
Multislice radio-frequency current density imaging
-
2-s2.0-67649546990 10.1109/TMI.2008.2012161
-
Wang D., DeMonte T. P., Ma W., Joy M. L. G., Nachman A. I., Multislice radio-frequency current density imaging. IEEE Transactions on Medical Imaging 2009 28 7 1083 1092 2-s2.0-67649546990 10.1109/TMI.2008.2012161
-
(2009)
IEEE Transactions on Medical Imaging
, vol.28
, Issue.7
, pp. 1083-1092
-
-
Wang, D.1
Demonte, T.P.2
Ma, W.3
Joy, M.L.G.4
Nachman, A.I.5
-
21
-
-
0034405181
-
The principle of reciprocity in signal strength calculations - A mathematical guide
-
2-s2.0-0034405181
-
Hoult D. I., The principle of reciprocity in signal strength calculations-a mathematical guide. Concepts in Magnetic Resonance 2000 12 4 173 187 2-s2.0-0034405181
-
(2000)
Concepts in Magnetic Resonance
, vol.12
, Issue.4
, pp. 173-187
-
-
Hoult, D.I.1
-
22
-
-
84894505871
-
Quantification error in MREPT due to B 1 map inaccuracy
-
Melbourne, Australia
-
Shin J., Lee J., Seo J. K., Kim D. H., Quantification error in MREPT due to B 1 map inaccuracy. 2533 Proceedings of the 20th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM '12) 2012 Melbourne, Australia
-
(2012)
Proceedings of the 20th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM '12)
, vol.2533
-
-
Shin, J.1
Lee, J.2
Seo, J.K.3
Kim, D.H.4
-
24
-
-
84876527530
-
Wave-number imaging at 7T: Increasing accuracy of EPT at high field strengths
-
Melbourne, Australia
-
van Lier A. L. H. M. W., Katscher U., Raaijmakers A., van den Berg C. A. T., Wave-number imaging at 7T: increasing accuracy of EPT at high field strengths. 3466 Proceedings of the 20th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM '12) 2012 Melbourne, Australia
-
(2012)
Proceedings of the 20th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM '12)
, vol.3466
-
-
Van Lier, A.L.H.M.W.1
Katscher, U.2
Raaijmakers, A.3
Van Den Berg, C.A.T.4
-
26
-
-
84856223581
-
B 1 + phase mapping at 7T and its application for in vivo electrical conductivity mapping
-
van Lier A. L., Brunner D. O., Pruessmann K. P., Klomp D. W., Luijten P. R., Lagendijk J. J., van den Berg C. A., B 1 + phase mapping at 7T and its application for in vivo electrical conductivity mapping. Magnetic Resonance in Medicine 2012 67 552 561
-
(2012)
Magnetic Resonance in Medicine
, vol.67
, pp. 552-561
-
-
Van Lier, A.L.1
Brunner, D.O.2
Pruessmann, K.P.3
Klomp, D.W.4
Luijten, P.R.5
Lagendijk, J.J.6
Van Den Berg, C.A.7
-
27
-
-
84890788550
-
Electric properties tomography in the human brain at 1.5, 3, and 7 T: A comparison study
-
10.1002/mrm.24637
-
van Lier A. L., Raaijmakers A., Voigt T., Lagendijk J. J., Katscher U., van den Berg C. A., Electric properties tomography in the human brain at 1.5, 3, and 7 T: a comparison study. Magnetic Resonance in Medicine 2013 10.1002/mrm.24637
-
(2013)
Magnetic Resonance in Medicine
-
-
Van Lier, A.L.1
Raaijmakers, A.2
Voigt, T.3
Lagendijk, J.J.4
Katscher, U.5
Van Den Berg, C.A.6
-
31
-
-
76249106990
-
Imaging electric properties of biological tissues by RF field mapping in MRI
-
2-s2.0-76249106990 10.1109/TMI.2009.2036843
-
Zhang X., Zhu S., He B., Imaging electric properties of biological tissues by RF field mapping in MRI. IEEE Transactions on Medical Imaging 2010 29 2 474 481 2-s2.0-76249106990 10.1109/TMI.2009.2036843
-
(2010)
IEEE Transactions on Medical Imaging
, vol.29
, Issue.2
, pp. 474-481
-
-
Zhang, X.1
Zhu, S.2
He, B.3
-
34
-
-
84870060828
-
B 1 -based specific energy absorption rate determination for nonquadrature radiofrequency excitation
-
Katscher U., Findeklee C., Voigt T., B 1 -based specific energy absorption rate determination for nonquadrature radiofrequency excitation. Magnetic Resonance in Medicine 2012 68 1911 1918
-
(2012)
Magnetic Resonance in Medicine
, vol.68
, pp. 1911-1918
-
-
Katscher, U.1
Findeklee, C.2
Voigt, T.3
-
35
-
-
33750630873
-
Parallel RF transmission with eight channels at 3 Tesla
-
DOI 10.1002/mrm.21042
-
Setsompop K., Wald L. L., Alagappan V., Gagoski B., Hebrank F., Fontius U., Schmitt F., Adalsteinsson E., Parallel RF transmission with eight channels at 3 Tesla. Magnetic Resonance in Medicine 2006 56 5 1163 1171 2-s2.0-33750630873 10.1002/mrm.21042 (Pubitemid 44691363)
-
(2006)
Magnetic Resonance in Medicine
, vol.56
, Issue.5
, pp. 1163-1171
-
-
Setsompop, K.1
Wald, L.L.2
Alagappan, V.3
Gagoski, B.4
Hebrank, F.5
Fontius, U.6
Schmitt, F.7
Adalsteinsson, E.8
-
36
-
-
34547940107
-
Eight-channel transmit/receive body MRI coil at 3T
-
DOI 10.1002/mrm.21294
-
Vernickel P., Röschmann P., Findeklee C., Lüdeke K. M., Leussler C., Overweg J., Katscher U., Grässlin I., Schünemann K., Eight-channel transmit/receive body MRI coil at 3T. Magnetic Resonance in Medicine 2007 58 2 381 389 2-s2.0-34547940107 10.1002/mrm.21294 (Pubitemid 47267656)
-
(2007)
Magnetic Resonance in Medicine
, vol.58
, Issue.2
, pp. 381-389
-
-
Vernickel, P.1
Roschmann, P.2
Findeklee, C.3
Ludeke, K.-M.4
Leussler, Ch.5
Overweg, J.6
Katscher, U.7
Grasslin, I.8
Schunemann, K.9
-
37
-
-
84856731252
-
Error analysis of nonconstant admittivity for MR-based electric property imging
-
Seo J. K., Kim M. O., Lee J., Choi N., Woo E. J., Kim H. J., Kwon O. I., Kim D. H., Error analysis of nonconstant admittivity for MR-based electric property imging. IEEE Transactions on Medical Imaging 2012 31 430 437
-
(2012)
IEEE Transactions on Medical Imaging
, vol.31
, pp. 430-437
-
-
Seo, J.K.1
Kim, M.O.2
Lee, J.3
Choi, N.4
Woo, E.J.5
Kim, H.J.6
Kwon, O.I.7
Kim, D.H.8
-
39
-
-
84876147229
-
Estimation of breast tumor conductivity using parabolic phase fitting
-
Katscher U., Djamshidi K., Voigt T., Ivancevic M., Abe H., Newstead G., Keupp J., Estimation of breast tumor conductivity using parabolic phase fitting. 3482 Proceedings of the 20th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM '12) 2012
-
(2012)
Proceedings of the 20th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM '12)
, vol.3482
-
-
Katscher, U.1
Djamshidi, K.2
Voigt, T.3
Ivancevic, M.4
Abe, H.5
Newstead, G.6
Keupp, J.7
-
41
-
-
84876562276
-
-
Computational and Mathematical Methods in Medicine. In press
-
Lee J., Song Y., Choi N., Cho S., Seo J. K., Kim D. H., Noninvasive measurement of conductivity anisotropy at larmor frequency using MRI. Computational and Mathematical Methods in Medicine. In press
-
Noninvasive Measurement of Conductivity Anisotropy at Larmor Frequency Using MRI
-
-
Lee, J.1
Song, Y.2
Choi, N.3
Cho, S.4
Seo, J.K.5
Kim, D.H.6
-
42
-
-
0025831477
-
Three-point Dixon technique for true water/fat decomposition with B0 inhomogeneity correction
-
2-s2.0-0025831477
-
Glover G. H., Schneider E., Three-point Dixon technique for true water/fat decomposition with B0 inhomogeneity correction. Magnetic Resonance in Medicine 1991 18 2 371 383 2-s2.0-0025831477
-
(1991)
Magnetic Resonance in Medicine
, vol.18
, Issue.2
, pp. 371-383
-
-
Glover, G.H.1
Schneider, E.2
-
44
-
-
84876463877
-
In vivo conductivity mapping using double spin echo for flow effect removal
-
Choi N., Ghim M., Yang S., Zho S.-Y., Kim D.-H., In vivo conductivity mapping using double spin echo for flow effect removal. 4466 Proceedings of the 19th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM '11) 2011
-
(2011)
Proceedings of the 19th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM '11)
, vol.4466
-
-
Choi, N.1
Ghim, M.2
Yang, S.3
Zho, S.-Y.4
Kim, D.-H.5
-
47
-
-
84863811552
-
Asymptotic analysis of the membrane structure to sensitivity of frequency-difference electrical impedance tomography
-
075004
-
Kim S., Lee E. J., Woo E. J., Seo J. K., Asymptotic analysis of the membrane structure to sensitivity of frequency-difference electrical impedance tomography. Inverse Problems 2012 28 075004
-
(2012)
Inverse Problems
, vol.28
-
-
Kim, S.1
Lee, E.J.2
Woo, E.J.3
Seo, J.K.4
-
51
-
-
0029909341
-
The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz
-
DOI 10.1088/0031-9155/41/11/002
-
Gabriel S., Lau R. W., Gabriel C., The dielectric properties of biological tissues-II. Measurements in the frequency range 10 Hz to 20 GHz. Physics in Medicine and Biology 1996 41 11 2251 2269 2-s2.0-0029909341 10.1088/0031-9155/41/11/002 (Pubitemid 26376902)
-
(1996)
Physics in Medicine and Biology
, vol.41
, Issue.11
, pp. 2251-2269
-
-
Gabriel, S.1
Lau, R.W.2
Gabriel, C.3
-
52
-
-
84890113700
-
Reproducibility study of 3D SSFP phase-based brain conductivity imaging
-
Stehning C., Voigt T. R., Katscher U., Reproducibility study of 3D SSFP phase-based brain conductivity imaging. MAGMA 2012 25 S197 S198
-
(2012)
MAGMA
, vol.25
-
-
Stehning, C.1
Voigt, T.R.2
Katscher, U.3
-
53
-
-
84890799814
-
In vivo glioma characterization using MR conductivity imaging
-
Voigt T., Vaterlein O., Stehning C., Katscher U., Fiehler J., In vivo glioma characterization using MR conductivity imaging. 127 Proceedings of the 19th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM '11) 2011
-
(2011)
Proceedings of the 19th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM '11)
, vol.127
-
-
Voigt, T.1
Vaterlein, O.2
Stehning, C.3
Katscher, U.4
Fiehler, J.5
-
55
-
-
0027096796
-
Dielectric properties of human glioma and surrounding tissue
-
Lu Y., Li B., Xu J., Yu J., Dielectric properties of human glioma and surrounding tissue. International Journal of Hyperthermia 1992 8 750 760
-
(1992)
International Journal of Hyperthermia
, vol.8
, pp. 750-760
-
-
Lu, Y.1
Li, B.2
Xu, J.3
Yu, J.4
-
56
-
-
84894413444
-
Electrical conductivity in ischemic stroke at 7.0 Tesla: A case study
-
van Lier A., Kolk A., Brundel M., Hendriske J., Luijten P., Lagendijk J., van den Berg C., Electrical conductivity in ischemic stroke at 7.0 Tesla: a case study. 3484 Proceedings of the 20th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM '12) 2012
-
(2012)
Proceedings of the 20th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM '12)
, vol.3484
-
-
Van Lier, A.1
Kolk, A.2
Brundel, M.3
Hendriske, J.4
Luijten, P.5
Lagendijk, J.6
Van Den Berg, C.7
-
58
-
-
84940096947
-
Conductivity imaging of an Ischemic pig heart model using electric properties tomography
-
Voigt T., Schuster A., Ishida M., Stehning C., Katscher U., Chiribiri A., Nagel E., Schaeffer T., Conductivity imaging of an Ischemic pig heart model using electric properties tomography. 3483 Proceedings of the 20th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM '12) 2012
-
(2012)
Proceedings of the 20th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM '12)
, vol.3483
-
-
Voigt, T.1
Schuster, A.2
Ishida, M.3
Stehning, C.4
Katscher, U.5
Chiribiri, A.6
Nagel, E.7
Schaeffer, T.8
-
60
-
-
84890113647
-
Feasibility of EPT in the Human Pelvis at 3T
-
Balidemaj E., van Lier A. L., Nederveen A. J., Crezee J., van den Berg C. A. T., Feasibility of EPT in the Human Pelvis at 3T. 3468 Proceedings of the 20th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM '12) 2012
-
(2012)
Proceedings of the 20th Scientific Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM '12)
, vol.3468
-
-
Balidemaj, E.1
Van Lier, A.L.2
Nederveen, A.J.3
Crezee, J.4
Van Den Berg, C.A.T.5
|