메뉴 건너뛰기




Volumn 29, Issue 2, 2010, Pages 474-481

Imaging electric properties of biological tissues by RF field mapping in MRI

Author keywords

B1 mapping; Electric properties (EPs); Electrical impedance imaging; Magnetic resonance electric properties tomography (MREPT)

Indexed keywords

3-D MODELING; B1 MAPPING; B1-MAPPING; BIOLOGICAL TISSUES; ELECTRICAL IMPEDANCE IMAGING; FIELD CALCULATION; HEAD MODEL; HIGH FIELD MRI; ITERATIVE COMPUTATION; MAPPING TECHNIQUES; RECONSTRUCTION ALGORITHMS; RELATIVE ERRORS; RF FIELDS; RF RADIATION; SIMULATION RESULT; SPECIFIC ABSORPTION RATE; TEM; TRANSVERSE MAGNETIC; WIRELESS TELECOMMUNICATIONS;

EID: 76249106990     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMI.2009.2036843     Document Type: Article
Times cited : (85)

References (41)
  • 1
    • 0036074376 scopus 로고    scopus 로고
    • Confocal microwave imaging for breast cancer detection: Localization of tumors in three dimensions
    • Aug.
    • E. C. Fear, X. Li, S. C. Hagness, and M. A. Stuchly, "Confocal microwave imaging for breast cancer detection: Localization of tumors in three dimensions, " IEEE Trans. Biomed. Eng., vol.49, no.8, pp. 812-822, Aug. 2002.
    • (2002) IEEE Trans. Biomed. Eng. , vol.49 , Issue.8 , pp. 812-822
    • Fear, E.C.1    Li, X.2    Hagness, S.C.3    Stuchly, M.A.4
  • 2
    • 0029954935 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues. 1. Literature survey
    • Nov.
    • C. Gabriel, S. Gabriel, and E. Corthout, "The dielectric properties of biological tissues. 1. Literature survey, " Phys. Med. Biol., vol.41, no.11, pp. 2231-2249, Nov. 1996.
    • (1996) Phys. Med. Biol. , vol.41 , Issue.11 , pp. 2231-2249
    • Gabriel, C.1    Gabriel, S.2    Corthout, E.3
  • 3
    • 0029909341 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz
    • DOI 10.1088/0031-9155/41/11/002
    • S. Gabriel, R. W. Lau, and C. Gabriel, "The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz, " Phys. Med. Biol., vol.41, no.11, pp. 2251-2269, Nov. 1996. (Pubitemid 26376902)
    • (1996) Physics in Medicine and Biology , vol.41 , Issue.11 , pp. 2251-2269
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 4
    • 0029957193 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues
    • DOI 10.1088/0031-9155/41/11/003
    • S. Gabriel, R. W. Lau, and C. Gabriel, "The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues, " Phys. Med. Biol., vol.41, no.11, pp. 2271-2293, Nov. 1996. (Pubitemid 26376903)
    • (1996) Physics in Medicine and Biology , vol.41 , Issue.11 , pp. 2271-2293
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 5
    • 0021673203 scopus 로고
    • Dielectric properties of normal & malignant human breast tissues at ra-diowave & microwave frequencies
    • Feb.
    • S. S. Chaudhary, R. K. Mishra, A. Swarup, and J. M. Thomas, "Dielectric properties of normal & malignant human breast tissues at ra-diowave & microwave frequencies, " Indian J. Biochem. Biophys., vol.21, no.1, pp. 76-79, Feb. 1984.
    • (1984) Dian J. Biochem. Biophys. , vol.21 , Issue.1 , pp. 76-79
    • Chaudhary, S.S.1    Mishra, R.K.2    Swarup, A.3    Thomas, J.M.4
  • 6
    • 0024000475 scopus 로고
    • Dielectric properties of breast carcinoma and the surrounding tissues
    • Apr.
    • A. J. Surowiec, S. S. Stuchly, J. B. Barr, and A. Swarup, "Dielectric properties of breast carcinoma and the surrounding tissues, " IEEE Trans. Biomed. Eng., vol.35, no.4, pp. 257-263, Apr. 1988.
    • (1988) IEEE Trans. Biomed. Eng. , vol.35 , Issue.4 , pp. 257-263
    • Surowiec, A.J.1    Stuchly, S.S.2    Barr, J.B.3    Swarup, A.4
  • 7
    • 0028359255 scopus 로고
    • The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz
    • Apr.
    • W. T. Joines, Y. Zhang, C. Li, and R. L. Jirtle, "The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz, " Med. Phys., vol.21, no.4, pp. 547-550, Apr. 1994.
    • (1994) Med. Phys. , vol.21 , Issue.4 , pp. 547-550
    • Joines, W.T.1    Zhang, Y.2    Li, C.3    Jirtle, R.L.4
  • 8
    • 0036591481 scopus 로고    scopus 로고
    • Electrical impedance spectroscopy of the breast: Clinical imaging results in 26 subjects
    • Jun.
    • T. E. Kerner, K. D. Paulsen, A. Hartov, S. K. Soho, and S. P. Poplack, "Electrical impedance spectroscopy of the breast: Clinical imaging results in 26 subjects, " IEEE Trans. Med. Imag., vol.21, no.6, pp. 638-645, Jun. 2002.
    • (2002) IEEE Trans. Med. Imag. , vol.21 , Issue.6 , pp. 638-645
    • Kerner, T.E.1    Paulsen, K.D.2    Hartov, A.3    Soho, S.K.4    Poplack, S.P.5
  • 9
    • 0035192680 scopus 로고    scopus 로고
    • Additional value of electrical impedance scanning: Experience of 240 histologically-proven breast lesions
    • Dec.
    • A. Malich, T. Bohm, M. Facius, M. Freessmeyer, M. Fleck, R. Anderson, and W. A. Kaiser, "Additional value of electrical impedance scanning: Experience of 240 histologically-proven breast lesions, " Eur. J. Cancer, vol.37, no.18, pp. 2324-2330, Dec. 2001.
    • (2001) Eur. J. Cancer , vol.37 , Issue.18 , pp. 2324-2330
    • Malich, A.1    Bohm, T.2    Facius, M.3    Freessmeyer, M.4    Fleck, M.5    Anderson, R.6    Kaiser, W.A.7
  • 10
    • 13344262689 scopus 로고    scopus 로고
    • Three-dimensional electrical impedance tomography
    • Apr.
    • P. Metherall, D. C. Barber, R. H. Smallwood, and B. H. Brown, "Three-dimensional electrical impedance tomography, " Nature, vol.380, no.6574, pp. 509-512, Apr. 1996.
    • (1996) Nature , vol.380 , Issue.6574 , pp. 509-512
    • Metherall, P.1    Barber, D.C.2    Smallwood, R.H.3    Brown, B.H.4
  • 11
    • 0032988044 scopus 로고    scopus 로고
    • Magnetic induction to-mography. A measuring system for biological tissues
    • Apr.
    • H. Griffiths, W. R. Stewart, and W. Gough, "Magnetic induction to-mography. A measuring system for biological tissues, " Ann. N. Y. Acad. Sci., vol.873, pp. 335-345, Apr. 1999.
    • (1999) Ann. N. Y. Acad. Sci. , vol.873 , pp. 335-345
    • Griffiths, H.1    Stewart, W.R.2    Gough, W.3
  • 12
    • 0024561625 scopus 로고
    • In vivo detection of applied electric currents by magnetic resonance imaging
    • M. Joy, G. Scott, and M. Henkelman, "In vivo detection of applied electric currents by magnetic resonance imaging, " Magn. Reson. Imag., vol.7, no.1, pp. 89-94, 1989.
    • (1989) Magn. Reson. Imag. , vol.7 , Issue.1 , pp. 89-94
    • Joy, M.1    Scott, G.2    Henkelman, M.3
  • 14
    • 0036591488 scopus 로고    scopus 로고
    • J-substitution algorithm in magnetic resonance electrical impedance tomography (MREIT): Phantom experiments for static resistivity images
    • DOI 10.1109/TMI.2002.800604, PII 1011092002800604, Electrical Impedance Tomography
    • H. S. Khang, B. I. Lee, S. H. Oh, E. J. Woo, S. Y. Lee, M. Y. Cho, O. Kwon, J. R. Yoon, and J. K. Seo, "J-substitution algorithm in Magnetic Resonance Electrical Impedance Tomography (MREIT): Phantom experiments for static resistivity images, " IEEE Trans. Med. Imag., vol.21, no.6, pp. 695-702, Jun. 2002. (Pubitemid 34950089)
    • (2002) IEEE Transactions on Medical Imaging , vol.21 , Issue.6 , pp. 695-702
    • Khang, H.S.1    Lee, B.I.2    Oh, S.H.3    Woo, E.J.4    Lee, S.Y.5    Cho, M.H.6    Kwon, O.7    Yoon, J.R.8    Seo, J.K.9
  • 15
    • 1342311383 scopus 로고    scopus 로고
    • Algebraic reconstruction for 3D magnetic resonance-electrical impedance tomography (MREIT) using one component of magnetic flux density
    • Feb.
    • Y. Z. Ider and S. Onart, "Algebraic reconstruction for 3D magnetic resonance-electrical impedance tomography (MREIT) using one component of magnetic flux density, " Physiol. Meas., vol.25, no.1, pp. 281-294, Feb. 2004.
    • (2004) Physiol. Meas. , vol.25 , Issue.1 , pp. 281-294
    • Ider, Y.Z.1    Onart, S.2
  • 16
    • 52149096321 scopus 로고    scopus 로고
    • Noninvasive imaging of head-brain conductivity profiles
    • Sep. /Oct.
    • X. T. Zhang, D. D. Yan, S. A. Zhu, and B. He, "Noninvasive imaging of head-brain conductivity profiles, " IEEE Eng. Med. Biol. Mag., vol.27, no.5, pp. 78-83, Sep. /Oct. 2008.
    • (2008) IEEE Eng. Med. Biol. Mag. , vol.27 , Issue.5 , pp. 78-83
    • Zhang, X.T.1    Yan, D.D.2    Zhu, S.A.3    He, B.4
  • 17
    • 27144458407 scopus 로고    scopus 로고
    • Magnetoacoustic tomography with magnetic induction (MAT-MI)
    • Y. Xu and B. He, "Magnetoacoustic tomography with magnetic induction (MAT-MI), " Phys. Med. Biol., vol.50, pp. 5175-5187, 2005.
    • (2005) Phys. Med. Biol. , vol.50 , pp. 5175-5187
    • Xu, Y.1    He, B.2
  • 18
    • 33846693445 scopus 로고    scopus 로고
    • Imaging electrical impedance from acoustic measurements by means of magnetoacoustic tomography with magnetic induction (MAT-MI)
    • Feb.
    • X. Li, Y. Xu, and B. He, "Imaging electrical impedance from acoustic measurements by means of magnetoacoustic tomography with magnetic induction (MAT-MI), " IEEE Trans. Biomed. Eng., vol.54, no.2, pp. 323-330, Feb. 2007.
    • (2007) IEEE Trans. Biomed. Eng. , vol.54 , Issue.2 , pp. 323-330
    • Li, X.1    Xu, Y.2    He, B.3
  • 19
    • 34548271717 scopus 로고    scopus 로고
    • Magnetoacoustic tomographic imaging of electrical impedance with magnetic induction
    • R. M. Xia, X. Li, andB. He, "Magnetoacoustic tomographic imaging of electrical impedance with magnetic induction, " Appl. Phys. Lett., vol.91, no.8, pp. 083903-1-083903-3, 2007.
    • (2007) Appl. Phys. Lett. , vol.91 , Issue.8 , pp. 083903-10839033
    • Xia, R.M.1    Li Andb. He, X.2
  • 20
    • 65549129746 scopus 로고    scopus 로고
    • Reconstruction of vectorial acoustic sources in time-domain tomography
    • May
    • R. M. Xia, X. Li, and B. He, "Reconstruction of vectorial acoustic sources in time-domain tomography, " IEEE Trans. Med. Imaging, vol.28, no.5, pp. 669-675, May 2009.
    • (2009) IEEE Trans. Med. Imaging , vol.28 , Issue.5 , pp. 669-675
    • Xia, R.M.1    Li, X.2    He, B.3
  • 21
    • 0025754003 scopus 로고
    • Extraction of conductivity and permittivity using magnetic resonance imaging
    • E. M. Haacke, L. S. Petropoulos, E. W. Nilges, and D. H. Wu, "Extraction of conductivity and permittivity using magnetic resonance imaging, " Phys. Med. Biol., vol.38, no.6, pp. 723-734, 1991.
    • (1991) Phys. Med. Biol. , vol.38 , Issue.6 , pp. 723-734
    • Haacke, E.M.1    Petropoulos, L.S.2    Nilges, E.W.3    Wu, D.H.4
  • 22
    • 0042376260 scopus 로고    scopus 로고
    • Noninvasive quantitative mapping ofconductivity and dielectric distributions using RF wave propagation effects in high-field MRI
    • H. Wen, "Noninvasive quantitative mapping ofconductivity and dielectric distributions using RF wave propagation effects in high-field MRI, " in Proc. SPIE, 2003, vol.5030, pp. 471-477.
    • (2003) Proc. SPIE , vol.5030 , pp. 471-477
    • Wen, H.1
  • 23
    • 78649934046 scopus 로고    scopus 로고
    • In vivo determination of electric conductivity and permittivity using a standard MR system
    • H. Scharfetter and R. Merwa, Eds. Berlin, Germany Springer
    • U. Katscher, T. Dorniok, C. Findeklee, P. Vernickel, and K. Nehrke, "In vivo determination of electric conductivity and permittivity using a standard MR system, " in IFMBE Proc. H. Scharfetter and R. Merwa, Eds. Berlin, Germany, vol.17, pp. 508-511, 2007, Springer.
    • (2007) IFMBE Proc. , vol.17 , pp. 508-511
    • Katscher, U.1    Dorniok, T.2    Findeklee, C.3    Vernickel, P.4    Nehrke, K.5
  • 24
    • 0032129166 scopus 로고    scopus 로고
    • Standing-wave and RF penetration artifacts causedby elliptic geometry:An electrodynamic analysis of MRI
    • Aug.
    • J. G. Sled and G. B. Pike, "Standing-wave and RF penetration artifacts causedby elliptic geometry:An electrodynamic analysis of MRI, " IEEE Trans. Med. Imag., vol.17, no.4, pp. 653-662, Aug. 1998.
    • (1998) IEEE Trans. Med. Imag. , vol.17 , Issue.4 , pp. 653-662
    • Sled, J.G.1    Pike, G.B.2
  • 25
    • 0034900050 scopus 로고    scopus 로고
    • Radio frequency magneticfield mapping ofa 3 Tesla birdcage coil: Experimental and theoretical dependence on sample properties
    • M. Alecci, C. M. Collins, M. B. Smith, and P. Jezzard, "Radio frequency magneticfield mapping ofa 3 Tesla birdcage coil: Experimental and theoretical dependence on sample properties, " Magn. Reson. Med., vol.46, no.2, pp. 379-385, 2001.
    • (2001) Magn. Reson. Med. , vol.46 , Issue.2 , pp. 379-385
    • Alecci, M.1    Collins, C.M.2    Smith, M.B.3    Jezzard, P.4
  • 27
    • 33847394130 scopus 로고    scopus 로고
    • In-depth study of the electromagnetics of ultrahigh-field MRI
    • Feb.
    • T. S. Ibrahim, C. Mitchell, R. Abraham, and P. Schmalbrock, "In-depth study of the electromagnetics of ultrahigh-field MRI, " NMR Biomed., vol.20, no.1, pp. 58-68, Feb. 2007.
    • (2007) NMR Biomed. , vol.20 , Issue.1 , pp. 58-68
    • Ibrahim, T.S.1    Mitchell, C.2    Abraham, R.3    Schmalbrock, P.4
  • 28
    • 0027253712 scopus 로고
    • Radiofrequency map of an NMR coil by imaging
    • S. Akoka, F. Franconi, F. Seguin, and A. Lepape, "Radiofrequency map of an NMR coil by imaging, " Magn. Reson. Imag., vol.11, no.3, pp. 437-441, 1993.
    • (1993) Magn. Reson. Imag. , vol.11 , Issue.3 , pp. 437-441
    • Akoka, S.1    Franconi, F.2    Seguin, F.3    Lepape, A.4
  • 29
    • 0002931369 scopus 로고
    • Mapping of the radiofrequency field
    • Jun.
    • E. K. Insko and L. Bolinger, "Mapping of the radiofrequency field, " J. Mag. Res. Ser. A, vol.103, no.1, pp. 82-85, Jun. 1993.
    • (1993) J. Mag. Res. Ser. A , vol.103 , Issue.1 , pp. 82-85
    • Insko, E.K.1    Bolinger, L.2
  • 30
    • 12844266240 scopus 로고    scopus 로고
    • Measurement and correction of transmitter and receiver induced nonuniformities in vivo
    • Feb.
    • J. H. Wang, M. L. Qiu, Q. X. Yang, M. B. Smith, and R. T. Constable, "Measurement and correction of transmitter and receiver induced nonuniformities in vivo, " Magn. Reson. Med., vol.53, no.2, pp. 408-417, Feb. 2005.
    • (2005) Magn. Reson. Med. , vol.53 , Issue.2 , pp. 408-417
    • Wang, J.H.1    Qiu, M.L.2    Yang, Q.X.3    Smith, M.B.4    Constable, R.T.5
  • 31
    • 0034405181 scopus 로고    scopus 로고
    • The principle of reciprocity in signal strength calcula-tions-A mathematical guide
    • D. I. Hoult, "The principle of reciprocity in signal strength calcula-tions-A mathematical guide, " Concepts Mag. Res., vol.12, no.4, pp. 173-187, 2000.
    • (2000) Concepts Mag. Res. , vol.12 , Issue.4 , pp. 173-187
    • Hoult, D.I.1
  • 36
    • 28044459877 scopus 로고
    • A perfectly matched layer for the absorption of electromagnetic-waves
    • Oct.
    • J. P. Berenger, "A perfectly matched layer for the absorption of electromagnetic-waves, " J. Comput. Phys., vol.114, no.2, pp. 185-200, Oct. 1994.
    • (1994) J. Comput. Phys. , vol.114 , Issue.2 , pp. 185-200
    • Berenger, J.P.1
  • 37
    • 34548278811 scopus 로고    scopus 로고
    • SAR simulation and the effect of mode coupling in a birdcage resonator
    • S. Reza, S. Vijayakumar, M. Limkeman, F. Huang, and C. Saylor, "SAR simulation and the effect of mode coupling in a birdcage resonator, " Concepts Mag. Res. B, vol.31B, no.3, pp. 133-139, 2007.
    • (2007) Concepts Mag. Res. B , vol.31 B , Issue.3 , pp. 133-139
    • Reza, S.1    Vijayakumar, S.2    Limkeman, M.3    Huang, F.4    Saylor, C.5
  • 38
    • 54949152106 scopus 로고
    • Electrical properties of tissue and cell suspensions
    • H. P. Schwan, "Electrical properties of tissue and cell suspensions, " Adv. Biol. Med. Phys., vol.5, pp. 147-209, 1957.
    • (1957) Adv. Biol. Med. Phys. , vol.5 , pp. 147-209
    • Schwan, H.P.1
  • 41
    • 38949112082 scopus 로고    scopus 로고
    • Local B-1(+) shimming for prostate imaging with transceiver arrays at 7T based on subject-dependent transmit phase measurements
    • Feb.
    • G. J. Metzger, C. Snyder, C. Akgun, T. Vaughan, K. Ugurbil, and P. F. Van de Moortele, "Local B-1(+) shimming for prostate imaging with transceiver arrays at 7T based on subject-dependent transmit phase measurements, " Magn. Reson. Med., vol.59, no.2, pp. 396-409, Feb. 2008.
    • (2008) Magn. Reson. Med. , vol.59 , Issue.2 , pp. 396-409
    • Metzger, G.J.1    Snyder, C.2    Akgun, C.3    Vaughan, T.4    Ugurbil, K.5    Moortele De Van, P.F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.