-
1
-
-
0036074376
-
Confocal microwave imaging for breast cancer detection: Localization of tumors in three dimensions
-
Aug.
-
E. C. Fear, X. Li, S. C. Hagness, and M. A. Stuchly, "Confocal microwave imaging for breast cancer detection: Localization of tumors in three dimensions, " IEEE Trans. Biomed. Eng., vol.49, no.8, pp. 812-822, Aug. 2002.
-
(2002)
IEEE Trans. Biomed. Eng.
, vol.49
, Issue.8
, pp. 812-822
-
-
Fear, E.C.1
Li, X.2
Hagness, S.C.3
Stuchly, M.A.4
-
2
-
-
0029954935
-
The dielectric properties of biological tissues. 1. Literature survey
-
Nov.
-
C. Gabriel, S. Gabriel, and E. Corthout, "The dielectric properties of biological tissues. 1. Literature survey, " Phys. Med. Biol., vol.41, no.11, pp. 2231-2249, Nov. 1996.
-
(1996)
Phys. Med. Biol.
, vol.41
, Issue.11
, pp. 2231-2249
-
-
Gabriel, C.1
Gabriel, S.2
Corthout, E.3
-
3
-
-
0029909341
-
The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz
-
DOI 10.1088/0031-9155/41/11/002
-
S. Gabriel, R. W. Lau, and C. Gabriel, "The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz, " Phys. Med. Biol., vol.41, no.11, pp. 2251-2269, Nov. 1996. (Pubitemid 26376902)
-
(1996)
Physics in Medicine and Biology
, vol.41
, Issue.11
, pp. 2251-2269
-
-
Gabriel, S.1
Lau, R.W.2
Gabriel, C.3
-
4
-
-
0029957193
-
The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues
-
DOI 10.1088/0031-9155/41/11/003
-
S. Gabriel, R. W. Lau, and C. Gabriel, "The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues, " Phys. Med. Biol., vol.41, no.11, pp. 2271-2293, Nov. 1996. (Pubitemid 26376903)
-
(1996)
Physics in Medicine and Biology
, vol.41
, Issue.11
, pp. 2271-2293
-
-
Gabriel, S.1
Lau, R.W.2
Gabriel, C.3
-
5
-
-
0021673203
-
Dielectric properties of normal & malignant human breast tissues at ra-diowave & microwave frequencies
-
Feb.
-
S. S. Chaudhary, R. K. Mishra, A. Swarup, and J. M. Thomas, "Dielectric properties of normal & malignant human breast tissues at ra-diowave & microwave frequencies, " Indian J. Biochem. Biophys., vol.21, no.1, pp. 76-79, Feb. 1984.
-
(1984)
Dian J. Biochem. Biophys.
, vol.21
, Issue.1
, pp. 76-79
-
-
Chaudhary, S.S.1
Mishra, R.K.2
Swarup, A.3
Thomas, J.M.4
-
6
-
-
0024000475
-
Dielectric properties of breast carcinoma and the surrounding tissues
-
Apr.
-
A. J. Surowiec, S. S. Stuchly, J. B. Barr, and A. Swarup, "Dielectric properties of breast carcinoma and the surrounding tissues, " IEEE Trans. Biomed. Eng., vol.35, no.4, pp. 257-263, Apr. 1988.
-
(1988)
IEEE Trans. Biomed. Eng.
, vol.35
, Issue.4
, pp. 257-263
-
-
Surowiec, A.J.1
Stuchly, S.S.2
Barr, J.B.3
Swarup, A.4
-
7
-
-
0028359255
-
The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz
-
Apr.
-
W. T. Joines, Y. Zhang, C. Li, and R. L. Jirtle, "The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz, " Med. Phys., vol.21, no.4, pp. 547-550, Apr. 1994.
-
(1994)
Med. Phys.
, vol.21
, Issue.4
, pp. 547-550
-
-
Joines, W.T.1
Zhang, Y.2
Li, C.3
Jirtle, R.L.4
-
8
-
-
0036591481
-
Electrical impedance spectroscopy of the breast: Clinical imaging results in 26 subjects
-
Jun.
-
T. E. Kerner, K. D. Paulsen, A. Hartov, S. K. Soho, and S. P. Poplack, "Electrical impedance spectroscopy of the breast: Clinical imaging results in 26 subjects, " IEEE Trans. Med. Imag., vol.21, no.6, pp. 638-645, Jun. 2002.
-
(2002)
IEEE Trans. Med. Imag.
, vol.21
, Issue.6
, pp. 638-645
-
-
Kerner, T.E.1
Paulsen, K.D.2
Hartov, A.3
Soho, S.K.4
Poplack, S.P.5
-
9
-
-
0035192680
-
Additional value of electrical impedance scanning: Experience of 240 histologically-proven breast lesions
-
Dec.
-
A. Malich, T. Bohm, M. Facius, M. Freessmeyer, M. Fleck, R. Anderson, and W. A. Kaiser, "Additional value of electrical impedance scanning: Experience of 240 histologically-proven breast lesions, " Eur. J. Cancer, vol.37, no.18, pp. 2324-2330, Dec. 2001.
-
(2001)
Eur. J. Cancer
, vol.37
, Issue.18
, pp. 2324-2330
-
-
Malich, A.1
Bohm, T.2
Facius, M.3
Freessmeyer, M.4
Fleck, M.5
Anderson, R.6
Kaiser, W.A.7
-
10
-
-
13344262689
-
Three-dimensional electrical impedance tomography
-
Apr.
-
P. Metherall, D. C. Barber, R. H. Smallwood, and B. H. Brown, "Three-dimensional electrical impedance tomography, " Nature, vol.380, no.6574, pp. 509-512, Apr. 1996.
-
(1996)
Nature
, vol.380
, Issue.6574
, pp. 509-512
-
-
Metherall, P.1
Barber, D.C.2
Smallwood, R.H.3
Brown, B.H.4
-
11
-
-
0032988044
-
Magnetic induction to-mography. A measuring system for biological tissues
-
Apr.
-
H. Griffiths, W. R. Stewart, and W. Gough, "Magnetic induction to-mography. A measuring system for biological tissues, " Ann. N. Y. Acad. Sci., vol.873, pp. 335-345, Apr. 1999.
-
(1999)
Ann. N. Y. Acad. Sci.
, vol.873
, pp. 335-345
-
-
Griffiths, H.1
Stewart, W.R.2
Gough, W.3
-
12
-
-
0024561625
-
In vivo detection of applied electric currents by magnetic resonance imaging
-
M. Joy, G. Scott, and M. Henkelman, "In vivo detection of applied electric currents by magnetic resonance imaging, " Magn. Reson. Imag., vol.7, no.1, pp. 89-94, 1989.
-
(1989)
Magn. Reson. Imag.
, vol.7
, Issue.1
, pp. 89-94
-
-
Joy, M.1
Scott, G.2
Henkelman, M.3
-
13
-
-
0003479345
-
-
M. S. thesis, Dept. Elect. Eng., Univ. Toronto, Toronto, ON, Canada
-
N. Zhang, "Electrical Impedance Tomography Based on Current Density Imaging, " M. S. thesis, Dept. Elect. Eng., Univ. Toronto, Toronto, ON, Canada, 1992.
-
(1992)
Electrical Impedance Tomography Based on Current Density Imaging
-
-
Zhang, N.1
-
14
-
-
0036591488
-
J-substitution algorithm in magnetic resonance electrical impedance tomography (MREIT): Phantom experiments for static resistivity images
-
DOI 10.1109/TMI.2002.800604, PII 1011092002800604, Electrical Impedance Tomography
-
H. S. Khang, B. I. Lee, S. H. Oh, E. J. Woo, S. Y. Lee, M. Y. Cho, O. Kwon, J. R. Yoon, and J. K. Seo, "J-substitution algorithm in Magnetic Resonance Electrical Impedance Tomography (MREIT): Phantom experiments for static resistivity images, " IEEE Trans. Med. Imag., vol.21, no.6, pp. 695-702, Jun. 2002. (Pubitemid 34950089)
-
(2002)
IEEE Transactions on Medical Imaging
, vol.21
, Issue.6
, pp. 695-702
-
-
Khang, H.S.1
Lee, B.I.2
Oh, S.H.3
Woo, E.J.4
Lee, S.Y.5
Cho, M.H.6
Kwon, O.7
Yoon, J.R.8
Seo, J.K.9
-
15
-
-
1342311383
-
Algebraic reconstruction for 3D magnetic resonance-electrical impedance tomography (MREIT) using one component of magnetic flux density
-
Feb.
-
Y. Z. Ider and S. Onart, "Algebraic reconstruction for 3D magnetic resonance-electrical impedance tomography (MREIT) using one component of magnetic flux density, " Physiol. Meas., vol.25, no.1, pp. 281-294, Feb. 2004.
-
(2004)
Physiol. Meas.
, vol.25
, Issue.1
, pp. 281-294
-
-
Ider, Y.Z.1
Onart, S.2
-
16
-
-
52149096321
-
Noninvasive imaging of head-brain conductivity profiles
-
Sep. /Oct.
-
X. T. Zhang, D. D. Yan, S. A. Zhu, and B. He, "Noninvasive imaging of head-brain conductivity profiles, " IEEE Eng. Med. Biol. Mag., vol.27, no.5, pp. 78-83, Sep. /Oct. 2008.
-
(2008)
IEEE Eng. Med. Biol. Mag.
, vol.27
, Issue.5
, pp. 78-83
-
-
Zhang, X.T.1
Yan, D.D.2
Zhu, S.A.3
He, B.4
-
17
-
-
27144458407
-
Magnetoacoustic tomography with magnetic induction (MAT-MI)
-
Y. Xu and B. He, "Magnetoacoustic tomography with magnetic induction (MAT-MI), " Phys. Med. Biol., vol.50, pp. 5175-5187, 2005.
-
(2005)
Phys. Med. Biol.
, vol.50
, pp. 5175-5187
-
-
Xu, Y.1
He, B.2
-
18
-
-
33846693445
-
Imaging electrical impedance from acoustic measurements by means of magnetoacoustic tomography with magnetic induction (MAT-MI)
-
Feb.
-
X. Li, Y. Xu, and B. He, "Imaging electrical impedance from acoustic measurements by means of magnetoacoustic tomography with magnetic induction (MAT-MI), " IEEE Trans. Biomed. Eng., vol.54, no.2, pp. 323-330, Feb. 2007.
-
(2007)
IEEE Trans. Biomed. Eng.
, vol.54
, Issue.2
, pp. 323-330
-
-
Li, X.1
Xu, Y.2
He, B.3
-
19
-
-
34548271717
-
Magnetoacoustic tomographic imaging of electrical impedance with magnetic induction
-
R. M. Xia, X. Li, andB. He, "Magnetoacoustic tomographic imaging of electrical impedance with magnetic induction, " Appl. Phys. Lett., vol.91, no.8, pp. 083903-1-083903-3, 2007.
-
(2007)
Appl. Phys. Lett.
, vol.91
, Issue.8
, pp. 083903-10839033
-
-
Xia, R.M.1
Li Andb. He, X.2
-
20
-
-
65549129746
-
Reconstruction of vectorial acoustic sources in time-domain tomography
-
May
-
R. M. Xia, X. Li, and B. He, "Reconstruction of vectorial acoustic sources in time-domain tomography, " IEEE Trans. Med. Imaging, vol.28, no.5, pp. 669-675, May 2009.
-
(2009)
IEEE Trans. Med. Imaging
, vol.28
, Issue.5
, pp. 669-675
-
-
Xia, R.M.1
Li, X.2
He, B.3
-
21
-
-
0025754003
-
Extraction of conductivity and permittivity using magnetic resonance imaging
-
E. M. Haacke, L. S. Petropoulos, E. W. Nilges, and D. H. Wu, "Extraction of conductivity and permittivity using magnetic resonance imaging, " Phys. Med. Biol., vol.38, no.6, pp. 723-734, 1991.
-
(1991)
Phys. Med. Biol.
, vol.38
, Issue.6
, pp. 723-734
-
-
Haacke, E.M.1
Petropoulos, L.S.2
Nilges, E.W.3
Wu, D.H.4
-
22
-
-
0042376260
-
Noninvasive quantitative mapping ofconductivity and dielectric distributions using RF wave propagation effects in high-field MRI
-
H. Wen, "Noninvasive quantitative mapping ofconductivity and dielectric distributions using RF wave propagation effects in high-field MRI, " in Proc. SPIE, 2003, vol.5030, pp. 471-477.
-
(2003)
Proc. SPIE
, vol.5030
, pp. 471-477
-
-
Wen, H.1
-
23
-
-
78649934046
-
In vivo determination of electric conductivity and permittivity using a standard MR system
-
H. Scharfetter and R. Merwa, Eds. Berlin, Germany Springer
-
U. Katscher, T. Dorniok, C. Findeklee, P. Vernickel, and K. Nehrke, "In vivo determination of electric conductivity and permittivity using a standard MR system, " in IFMBE Proc. H. Scharfetter and R. Merwa, Eds. Berlin, Germany, vol.17, pp. 508-511, 2007, Springer.
-
(2007)
IFMBE Proc.
, vol.17
, pp. 508-511
-
-
Katscher, U.1
Dorniok, T.2
Findeklee, C.3
Vernickel, P.4
Nehrke, K.5
-
24
-
-
0032129166
-
Standing-wave and RF penetration artifacts causedby elliptic geometry:An electrodynamic analysis of MRI
-
Aug.
-
J. G. Sled and G. B. Pike, "Standing-wave and RF penetration artifacts causedby elliptic geometry:An electrodynamic analysis of MRI, " IEEE Trans. Med. Imag., vol.17, no.4, pp. 653-662, Aug. 1998.
-
(1998)
IEEE Trans. Med. Imag.
, vol.17
, Issue.4
, pp. 653-662
-
-
Sled, J.G.1
Pike, G.B.2
-
25
-
-
0034900050
-
Radio frequency magneticfield mapping ofa 3 Tesla birdcage coil: Experimental and theoretical dependence on sample properties
-
M. Alecci, C. M. Collins, M. B. Smith, and P. Jezzard, "Radio frequency magneticfield mapping ofa 3 Tesla birdcage coil: Experimental and theoretical dependence on sample properties, " Magn. Reson. Med., vol.46, no.2, pp. 379-385, 2001.
-
(2001)
Magn. Reson. Med.
, vol.46
, Issue.2
, pp. 379-385
-
-
Alecci, M.1
Collins, C.M.2
Smith, M.B.3
Jezzard, P.4
-
26
-
-
0036240672
-
Analysis of wave behavior in lossy dielectric samples at high field
-
Q. X. Yang, J. H. Wang, X. L. Zhang, C. M. Collins, M. B. Smith, H. Y. Liu, X. H. Zhu, J. T. Vaughan, K. Ugurbil, and W. Chen, "Analysis of wave behavior in lossy dielectric samples at high field, " Magn. Reson. Med., vol.47, no.5, pp. 982-989, 2002.
-
(2002)
Magn. Reson. Med.
, vol.47
, Issue.5
, pp. 982-989
-
-
Yang, Q.X.1
Wang, J.H.2
Zhang, X.L.3
Collins, C.M.4
Smith, M.B.5
Liu, H.Y.6
Zhu, X.H.7
Vaughan, J.T.8
Ugurbil, K.9
Chen, W.10
-
27
-
-
33847394130
-
In-depth study of the electromagnetics of ultrahigh-field MRI
-
Feb.
-
T. S. Ibrahim, C. Mitchell, R. Abraham, and P. Schmalbrock, "In-depth study of the electromagnetics of ultrahigh-field MRI, " NMR Biomed., vol.20, no.1, pp. 58-68, Feb. 2007.
-
(2007)
NMR Biomed.
, vol.20
, Issue.1
, pp. 58-68
-
-
Ibrahim, T.S.1
Mitchell, C.2
Abraham, R.3
Schmalbrock, P.4
-
28
-
-
0027253712
-
Radiofrequency map of an NMR coil by imaging
-
S. Akoka, F. Franconi, F. Seguin, and A. Lepape, "Radiofrequency map of an NMR coil by imaging, " Magn. Reson. Imag., vol.11, no.3, pp. 437-441, 1993.
-
(1993)
Magn. Reson. Imag.
, vol.11
, Issue.3
, pp. 437-441
-
-
Akoka, S.1
Franconi, F.2
Seguin, F.3
Lepape, A.4
-
29
-
-
0002931369
-
Mapping of the radiofrequency field
-
Jun.
-
E. K. Insko and L. Bolinger, "Mapping of the radiofrequency field, " J. Mag. Res. Ser. A, vol.103, no.1, pp. 82-85, Jun. 1993.
-
(1993)
J. Mag. Res. Ser. A
, vol.103
, Issue.1
, pp. 82-85
-
-
Insko, E.K.1
Bolinger, L.2
-
30
-
-
12844266240
-
Measurement and correction of transmitter and receiver induced nonuniformities in vivo
-
Feb.
-
J. H. Wang, M. L. Qiu, Q. X. Yang, M. B. Smith, and R. T. Constable, "Measurement and correction of transmitter and receiver induced nonuniformities in vivo, " Magn. Reson. Med., vol.53, no.2, pp. 408-417, Feb. 2005.
-
(2005)
Magn. Reson. Med.
, vol.53
, Issue.2
, pp. 408-417
-
-
Wang, J.H.1
Qiu, M.L.2
Yang, Q.X.3
Smith, M.B.4
Constable, R.T.5
-
31
-
-
0034405181
-
The principle of reciprocity in signal strength calcula-tions-A mathematical guide
-
D. I. Hoult, "The principle of reciprocity in signal strength calcula-tions-A mathematical guide, " Concepts Mag. Res., vol.12, no.4, pp. 173-187, 2000.
-
(2000)
Concepts Mag. Res.
, vol.12
, Issue.4
, pp. 173-187
-
-
Hoult, D.I.1
-
34
-
-
4744353976
-
Efficient high-frequency body coil for high-field MRI
-
Oct.
-
J. T. Vaughan, G. Adriany, C. J. Snyder, J. Tian, T. Thiel, L. Bolinger, H. Liu, L. DelaBarre, and K. Ugurbil, "Efficient high-frequency body coil for high-field MRI, " Magn. Reson. Med., vol.52, no.4, pp. 851-859, Oct. 2004.
-
(2004)
Magn. Reson. Med.
, vol.52
, Issue.4
, pp. 851-859
-
-
Vaughan, J.T.1
Adriany, G.2
Snyder, C.J.3
Tian, J.4
Thiel, T.5
Bolinger, L.6
Liu, H.7
Delabarre, L.8
Ugurbil, K.9
-
36
-
-
28044459877
-
A perfectly matched layer for the absorption of electromagnetic-waves
-
Oct.
-
J. P. Berenger, "A perfectly matched layer for the absorption of electromagnetic-waves, " J. Comput. Phys., vol.114, no.2, pp. 185-200, Oct. 1994.
-
(1994)
J. Comput. Phys.
, vol.114
, Issue.2
, pp. 185-200
-
-
Berenger, J.P.1
-
37
-
-
34548278811
-
SAR simulation and the effect of mode coupling in a birdcage resonator
-
S. Reza, S. Vijayakumar, M. Limkeman, F. Huang, and C. Saylor, "SAR simulation and the effect of mode coupling in a birdcage resonator, " Concepts Mag. Res. B, vol.31B, no.3, pp. 133-139, 2007.
-
(2007)
Concepts Mag. Res. B
, vol.31 B
, Issue.3
, pp. 133-139
-
-
Reza, S.1
Vijayakumar, S.2
Limkeman, M.3
Huang, F.4
Saylor, C.5
-
38
-
-
54949152106
-
Electrical properties of tissue and cell suspensions
-
H. P. Schwan, "Electrical properties of tissue and cell suspensions, " Adv. Biol. Med. Phys., vol.5, pp. 147-209, 1957.
-
(1957)
Adv. Biol. Med. Phys.
, vol.5
, pp. 147-209
-
-
Schwan, H.P.1
-
40
-
-
77951021793
-
Electrical conductivity imaging using magnetic resonance tomography
-
Minneapolis, MN
-
U. Katscher, T. Voigt, and C. Findeklee, "Electrical conductivity imaging using magnetic resonance tomography, " in Proc. Conf. Proc. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., Minneapolis, MN, 2009, pp. 3162-3164.
-
(2009)
Proc. Conf. Proc. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc.
, pp. 3162-3164
-
-
Katscher, U.1
Voigt, T.2
Findeklee, C.3
-
41
-
-
38949112082
-
Local B-1(+) shimming for prostate imaging with transceiver arrays at 7T based on subject-dependent transmit phase measurements
-
Feb.
-
G. J. Metzger, C. Snyder, C. Akgun, T. Vaughan, K. Ugurbil, and P. F. Van de Moortele, "Local B-1(+) shimming for prostate imaging with transceiver arrays at 7T based on subject-dependent transmit phase measurements, " Magn. Reson. Med., vol.59, no.2, pp. 396-409, Feb. 2008.
-
(2008)
Magn. Reson. Med.
, vol.59
, Issue.2
, pp. 396-409
-
-
Metzger, G.J.1
Snyder, C.2
Akgun, C.3
Vaughan, T.4
Ugurbil, K.5
Moortele De Van, P.F.6
|