메뉴 건너뛰기




Volumn 58, Issue 2, 2013, Pages 534-539

Benefits and limitations of cap-fitted colonoscopy in screening colonoscopy

Author keywords

Cap fitted colonoscopy; Colon; Colonoscopy; Colorectal adenoma

Indexed keywords

AGED; ARTICLE; CANCER SCREENING; CECUM; COLONOSCOPE; COLONOSCOPY; COLORECTAL ADENOMA; CONTROLLED STUDY; DEMOGRAPHY; DIGESTIVE TRACT INTUBATION; FEMALE; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SCREENING; ADENOMA; ADULT; CASE CONTROL STUDY; COLON TUMOR; COMPARATIVE STUDY; INSTRUMENTATION; MASS SCREENING; METHODOLOGY; MIDDLE AGED; REPRODUCIBILITY; RISK FACTOR; STANDARD;

EID: 84876328646     PISSN: 01632116     EISSN: 15732568     Source Type: Journal    
DOI: 10.1007/s10620-012-2403-1     Document Type: Article
Times cited : (18)

References (31)
  • 1
    • 37949049850 scopus 로고
    • The evolution of cancer of the colon and rectum
    • 1203876 10.1002/cncr.2820360944 1:STN:280:DyaE28%2FptVWqtg%3D%3D
    • Muto T, Bussey H, Morson BC. The evolution of cancer of the colon and rectum. Cancer. 1975;36:2251-2270.
    • (1975) Cancer , vol.36 , pp. 2251-2270
    • Muto, T.1    Bussey, H.2    Morson, B.C.3
  • 2
    • 0031014334 scopus 로고    scopus 로고
    • Relative sensitivity of colonoscopy and barium enema for detection of colorectal cancer in clinical practice
    • 8978337 10.1016/S0016-5085(97)70213-0 1:STN:280:DyaK2s7jt12kug%3D%3D
    • Rex D, Rahmani EY, Haseman JH, Lemmel GT, Kaster S, Buckley JS. Relative sensitivity of colonoscopy and barium enema for detection of colorectal cancer in clinical practice. Gastroenterology. 1997;112:17-23.
    • (1997) Gastroenterology , vol.112 , pp. 17-23
    • Rex, D.1    Rahmani, E.Y.2    Haseman, J.H.3    Lemmel, G.T.4    Kaster, S.5    Buckley, J.S.6
  • 3
    • 0027403555 scopus 로고
    • Randomized comparison of surveillance intervals after colonoscopic removal of newly diagnosed adenomatous polyps
    • 8446136 10.1056/NEJM199304013281301 1:STN:280:DyaK3s7ovV2itw%3D%3D
    • Winawer SJ, Zauber AG, O'Brien MJ, et al. Randomized comparison of surveillance intervals after colonoscopic removal of newly diagnosed adenomatous polyps. N Engl J Med. 1993;328:901-906.
    • (1993) N Engl J Med , vol.328 , pp. 901-906
    • Winawer, S.J.1    Zauber, A.G.2    O'Brien, M.J.3
  • 4
    • 0027731797 scopus 로고
    • Prevention of colorectal cancer by colonoscopic polypectomy
    • 8247072 10.1056/NEJM199312303292701 1:STN:280:DyaK2c%2Fmslamug%3D%3D
    • Winawer SJ, Zauber AG, Ho MN, et al. Prevention of colorectal cancer by colonoscopic polypectomy. N Engl J Med. 1993;329:1977-1981.
    • (1993) N Engl J Med , vol.329 , pp. 1977-1981
    • Winawer, S.J.1    Zauber, A.G.2    Ho, M.N.3
  • 5
    • 0025610533 scopus 로고
    • Prospective study of the frequency and size distribution of polyps missed by colonoscopy
    • 2231773 10.1093/jnci/82.22.1769 1:STN:280:DyaK3M%2FjvFeqtQ%3D%3D
    • Hixson LS, Fennerty MB, Sampliner RE, McGee D, Garewal H. Prospective study of the frequency and size distribution of polyps missed by colonoscopy. J Natl Cancer Inst. 1990;82:1769-1772.
    • (1990) J Natl Cancer Inst , vol.82 , pp. 1769-1772
    • Hixson, L.S.1    Fennerty, M.B.2    Sampliner, R.E.3    McGee, D.4    Garewal, H.5
  • 6
    • 0031022236 scopus 로고    scopus 로고
    • Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies
    • 8978338 10.1016/S0016-5085(97)70214-2 1:STN:280:DyaK2s7jt12kuw%3D%3D
    • Rex DK, Cutler CS, Lemmel GT, et al. Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies. Gastroenterology. 1997;112:24-28.
    • (1997) Gastroenterology , vol.112 , pp. 24-28
    • Rex, D.K.1    Cutler, C.S.2    Lemmel, G.T.3
  • 8
    • 4143084914 scopus 로고    scopus 로고
    • Colonoscopic miss rates for right-sided colon cancer: A population-based analysis
    • 15300577 10.1053/j.gastro.2004.05.032
    • Bressler B, Paszat LF, Vinden C, et al. Colonoscopic miss rates for right-sided colon cancer: a population-based analysis. Gastroenterology. 2004;127:452-456.
    • (2004) Gastroenterology , vol.127 , pp. 452-456
    • Bressler, B.1    Paszat, L.F.2    Vinden, C.3
  • 9
    • 77957337438 scopus 로고    scopus 로고
    • The reduction in colorectal cancer mortality after colonoscopy varies by site of the cancer
    • 20600026 10.1053/j.gastro.2010.06.052
    • Singh H, Nugent Z, Demers AA, et al. The reduction in colorectal cancer mortality after colonoscopy varies by site of the cancer. Gastroenterology. 2010;139:1128-1137.
    • (2010) Gastroenterology , vol.139 , pp. 1128-1137
    • Singh, H.1    Nugent, Z.2    Demers, A.A.3
  • 10
    • 80155156963 scopus 로고    scopus 로고
    • Improving protection against proximal colon cancer by colonoscopy
    • 22017701 10.1586/egh.11.78
    • Lasisi F, Rex DK. Improving protection against proximal colon cancer by colonoscopy. Expert Rev Gastroenterol Hepatol. 2011;5:745-754.
    • (2011) Expert Rev Gastroenterol Hepatol , vol.5 , pp. 745-754
    • Lasisi, F.1    Rex, D.K.2
  • 11
    • 80051783980 scopus 로고    scopus 로고
    • Evolving techniques in colonoscopy
    • 21785352 10.1097/MOG.0b013e328349cfc0
    • Vemulapalli KC, Rex DK. Evolving techniques in colonoscopy. Curr Opin Gastroenterol. 2011;27:430-438.
    • (2011) Curr Opin Gastroenterol. , vol.27 , pp. 430-438
    • Vemulapalli, K.C.1    Rex, D.K.2
  • 12
    • 0031878931 scopus 로고    scopus 로고
    • Efficacy of total colonoscopy with a transparent cap in comparison with colonoscopy without the cap
    • 10.1055/s-2007-1001305
    • Matsushima M, Hajiro K, Okazaki K, Takakuwa H, Tominaga M. Efficacy of total colonoscopy with a transparent cap in comparison with colonoscopy without the cap. Endoscopy. 1998;30:444-447.
    • (1998) Endoscopy , vol.30 , pp. 444-447
    • Matsushima, M.1    Hajiro, K.2    Okazaki, K.3    Takakuwa, H.4    Tominaga, M.5
  • 13
    • 0034006609 scopus 로고    scopus 로고
    • Technical considerations and patient comfort in total colonoscopy with and without a transparent cap: Initial experiences from a pilot study
    • 10817176 10.1055/s-2000-637 1:STN:280:DC%2BD3c3nsVyktQ%3D%3D
    • Dafnis GM. Technical considerations and patient comfort in total colonoscopy with and without a transparent cap: initial experiences from a pilot study. Endoscopy. 2000;32:381-384.
    • (2000) Endoscopy , vol.32 , pp. 381-384
    • Dafnis, G.M.1
  • 14
    • 33745895288 scopus 로고    scopus 로고
    • Improved colonoscopy success rate with a distally attached mucosectomy cap
    • 16673307 10.1055/s-2006-925238 1:STN:280:DC%2BD28zptFOgtQ%3D%3D
    • Lee YT, Hul AJ, Wong VWS, Hung LCT, Sung JJY. Improved colonoscopy success rate with a distally attached mucosectomy cap. Endoscopy. 2006;38:739-742.
    • (2006) Endoscopy , vol.38 , pp. 739-742
    • Lee, Y.T.1    Hul, A.J.2    Wong, V.W.S.3    Hung, L.C.T.4    Sung, J.J.Y.5
  • 15
    • 33846083339 scopus 로고    scopus 로고
    • A randomized controlled trial evaluation the usefulness of a transparent hood attached to the tip of the colonoscope
    • 17100978 10.1111/j.1572-0241.2006.00897.x
    • Kondo S, Yamaji Y, Watabe H, et al. A randomized controlled trial evaluation the usefulness of a transparent hood attached to the tip of the colonoscope. Am J Gastroenterol. 2007;102:75-81.
    • (2007) Am J Gastroenterol , vol.102 , pp. 75-81
    • Kondo, S.1    Yamaji, Y.2    Watabe, H.3
  • 16
    • 60749087179 scopus 로고    scopus 로고
    • Efficacy of cap-assisted colonoscopy in comparison with regular colonoscopy: A randomized controlled trial
    • 19098847 10.1038/ajg.2008.56
    • Lee YT, Lai LH, Hui AJ, et al. Efficacy of cap-assisted colonoscopy in comparison with regular colonoscopy: a randomized controlled trial. Am J Gastroenterol. 2009;104:41-46.
    • (2009) Am J Gastroenterol , vol.104 , pp. 41-46
    • Lee, Y.T.1    Lai, L.H.2    Hui, A.J.3
  • 17
    • 77957563642 scopus 로고    scopus 로고
    • Cap-fitted colonoscopy: A randomized, tandem colonoscopy study of adenoma miss rates
    • 20579648 10.1016/j.gie.2010.04.030
    • Hewett DG, Rex DK. Cap-fitted colonoscopy: a randomized, tandem colonoscopy study of adenoma miss rates. Gastrointest Endosc. 2010;72:775-781.
    • (2010) Gastrointest Endosc , vol.72 , pp. 775-781
    • Hewett, D.G.1    Rex, D.K.2
  • 18
    • 39049089493 scopus 로고    scopus 로고
    • Improved colorectal adenoma detection with a transparent retractable extension device
    • 18076740 10.1111/j.1572-0241.2007.01555.x
    • Horiuchi A, Nakayama Y. Improved colorectal adenoma detection with a transparent retractable extension device. Am J Gastroenterol. 2008;103:341-345.
    • (2008) Am J Gastroenterol , vol.103 , pp. 341-345
    • Horiuchi, A.1    Nakayama, Y.2
  • 19
    • 77949655588 scopus 로고    scopus 로고
    • Hood-assisted colonoscopy is more effective in detection of colorectal adenomas than narrow band-imaging
    • 19716434 10.1016/j.cgh.2009.08.018
    • Horiuchi A, Nakayama Y, Kato N, Ichise Y, Kajiyama M, Tanaka N. Hood-assisted colonoscopy is more effective in detection of colorectal adenomas than narrow band-imaging. Clin Gastroenterol Hepatol. 2010;8:379-383.
    • (2010) Clin Gastroenterol Hepatol , vol.8 , pp. 379-383
    • Horiuchi, A.1    Nakayama, Y.2    Kato, N.3    Ichise, Y.4    Kajiyama, M.5    Tanaka, N.6
  • 20
    • 78649553404 scopus 로고    scopus 로고
    • Transparent cap improves subjects' tolerance of colonoscopy and shortens examination time by inexperienced endoscopists
    • 21091899 10.1111/j.1751-2980.2010.00460.x
    • Dai J, Feng N, Lu H, et al. Transparent cap improves subjects' tolerance of colonoscopy and shortens examination time by inexperienced endoscopists. J Dig Dis. 2010;11:364-368.
    • (2010) J Dig Dis , vol.11 , pp. 364-368
    • Dai, J.1    Feng, N.2    Lu, H.3
  • 21
    • 84857048897 scopus 로고    scopus 로고
    • Higher adenoma detection rates with cap-assisted colonoscopy: A randomized controlled trial
    • 21997547 10.1136/gutjnl-2011-300187
    • Rastogi A, Bansal A, Rao DS, et al. Higher adenoma detection rates with cap-assisted colonoscopy: a randomized controlled trial. Gut. 2012;61:402-408.
    • (2012) Gut , vol.61 , pp. 402-408
    • Rastogi, A.1    Bansal, A.2    Rao, D.S.3
  • 22
    • 80053257481 scopus 로고    scopus 로고
    • Usefulness of cap-assisted colonoscopy during colonoscopic EMR: A randomized, controlled trial
    • 21824612 10.1016/j.gie.2011.06.005
    • Park SY, Kim HS, Yoon KW, et al. Usefulness of cap-assisted colonoscopy during colonoscopic EMR: a randomized, controlled trial. Gastrointest Endosc. 2011;74:869-875.
    • (2011) Gastrointest Endosc , vol.74 , pp. 869-875
    • Park, S.Y.1    Kim, H.S.2    Yoon, K.W.3
  • 23
    • 77955929091 scopus 로고    scopus 로고
    • Prospective randomized controlled trial evaluating cap-assisted colonoscopy vs. standard colonoscopy
    • 20712051 10.3748/wjg.v16.i31.3905
    • Tee HP, Corte C, Al-Ghamdi H, et al. Prospective randomized controlled trial evaluating cap-assisted colonoscopy vs. standard colonoscopy. World J Gastroenterol. 2010;16:3905-3910.
    • (2010) World J Gastroenterol , vol.16 , pp. 3905-3910
    • Tee, H.P.1    Corte, C.2    Al-Ghamdi, H.3
  • 24
    • 67650461952 scopus 로고    scopus 로고
    • Low-dose propofol sedation for diagnostic esophagogastroduodenoscopy: Results in 10,662 adults
    • 19513021 10.1038/ajg.2009.250 1:CAS:528:DC%2BD1MXotVKjtbc%3D
    • Horiuchi A, Nakayama Y, Hidaka N, Ichise Y, Kajiyama M, Tanaka N. Low-dose propofol sedation for diagnostic esophagogastroduodenoscopy: results in 10,662 adults. Am J Gastroenterol. 2009;104:1650-1655.
    • (2009) Am J Gastroenterol , vol.104 , pp. 1650-1655
    • Horiuchi, A.1    Nakayama, Y.2    Hidaka, N.3    Ichise, Y.4    Kajiyama, M.5    Tanaka, N.6
  • 25
    • 84857197106 scopus 로고    scopus 로고
    • Psychomotor recovery and blood propofol level in colonoscopy when using propofol sedation
    • 22115604 10.1016/j.gie.2011.08.020
    • Horiuchi A, Nakayama Y, Fujii H, Katsuyama Y, Ohmori S, Tanaka N. Psychomotor recovery and blood propofol level in colonoscopy when using propofol sedation. Gastrointest Endosc. 2012;75:506-512.
    • (2012) Gastrointest Endosc , vol.75 , pp. 506-512
    • Horiuchi, A.1    Nakayama, Y.2    Fujii, H.3    Katsuyama, Y.4    Ohmori, S.5    Tanaka, N.6
  • 26
    • 52249115178 scopus 로고    scopus 로고
    • Nonpolypoid neoplastic lesions of the colorectal mucosa
    • 18805238 10.1016/j.gie.2008.07.052
    • Kudo S, Lambert R, Allen JI, et al. Nonpolypoid neoplastic lesions of the colorectal mucosa. Gastrointest Endosc. 2008;68:S3-S47.
    • (2008) Gastrointest Endosc , vol.68
    • Kudo, S.1    Lambert, R.2    Allen, J.I.3
  • 27
    • 0030983287 scopus 로고    scopus 로고
    • Feasibility of the transparent cap-fitted colonoscope for screening and mucosal resection
    • 9152195 10.1007/BF02055390 1:STN:280:DyaK2s3ps1OhtA%3D%3D
    • Tada M, Inoue H, Yabata E, et al. Feasibility of the transparent cap-fitted colonoscope for screening and mucosal resection. Dis Colon Rectum. 1997;40:618-621.
    • (1997) Dis Colon Rectum , vol.40 , pp. 618-621
    • Tada, M.1    Inoue, H.2    Yabata, E.3
  • 28
    • 84860457524 scopus 로고    scopus 로고
    • Transparent-cap-fitted colonoscopy shows higher performance with cecal intubation time in difficult cases
    • 22563177 10.3748/wjg.v18.i16.1953
    • Kim HH, Park SJ, Park MI, et al. Transparent-cap-fitted colonoscopy shows higher performance with cecal intubation time in difficult cases. World J Gastroenterol. 2012;18:1953-1958.
    • (2012) World J Gastroenterol , vol.18 , pp. 1953-1958
    • Kim, H.H.1    Park, S.J.2    Park, M.I.3
  • 29
    • 84857826128 scopus 로고    scopus 로고
    • Cap-assisted colonoscopy (CAC) significantly extends visualization in the right colon
    • 22383283 10.1055/s-0031-1281707 1:STN:280:DC%2BC38ris12iuw%3D%3D
    • Frieling T, Neuhaus F, Heise J, et al. Cap-assisted colonoscopy (CAC) significantly extends visualization in the right colon. Z Gastroenterol. 2012;50:279-284.
    • (2012) Z Gastroenterol , vol.50 , pp. 279-284
    • Frieling, T.1    Neuhaus, F.2    Heise, J.3
  • 30
    • 0038310897 scopus 로고    scopus 로고
    • Detection of colorectal adenomas by routine chromoendoscopy with indigocarmine
    • 12818270 10.1111/j.1572-0241.2003.07473.x
    • Lee JH, Kim JW, Cho YK, et al. Detection of colorectal adenomas by routine chromoendoscopy with indigocarmine. Am J Gastroenterol. 2003;98:1284-1288.
    • (2003) Am J Gastroenterol , vol.98 , pp. 1284-1288
    • Lee, J.H.1    Kim, J.W.2    Cho, Y.K.3
  • 31
    • 33845421083 scopus 로고    scopus 로고
    • Comparative study of conventional colonoscopy, chromoendoscopy, and narrow-band imaging systems in differential diagnosis of neoplastic and nonneoplastic colonic polyps
    • 17227517 10.1111/j.1572-0241.2006.00932.x
    • Su MY, Hsu CM, Ho YP, Chen PC, Lin CJ, Chiu CT. Comparative study of conventional colonoscopy, chromoendoscopy, and narrow-band imaging systems in differential diagnosis of neoplastic and nonneoplastic colonic polyps. Am J Gastroenterol. 2006;101:2711-2716.
    • (2006) Am J Gastroenterol , vol.101 , pp. 2711-2716
    • Su, M.Y.1    Hsu, C.M.2    Ho, Y.P.3    Chen, P.C.4    Lin, C.J.5    Chiu, C.T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.