메뉴 건너뛰기




Volumn 135, Issue 3, 2013, Pages

An experimental review on microbubble generation to be used in echo-particle image velocimetry method to determine the pipe flow velocity

Author keywords

echo PIV; flow focusing; microbubble; microchannel; ultrasound contrast agent

Indexed keywords

ECHO PIV; FLOW FOCUSING; MICRO-BUBBLE; MICROBUBBLE CONTRAST AGENTS; MICROBUBBLE GENERATION; MICROCHANNEL FABRICATION; SURFACTANT CONCENTRATIONS; ULTRASOUND CONTRAST AGENT;

EID: 84876208349     PISSN: 00982202     EISSN: 1528901X     Source Type: Journal    
DOI: 10.1115/1.4023406     Document Type: Article
Times cited : (13)

References (20)
  • 2
    • 10844287248 scopus 로고    scopus 로고
    • Monodispersed microbubble formation using microchannel technique
    • DOI 10.1002/aic.10276
    • Yasuno, M., Sugiura, S., Iwamoto, S., Nakajima, M., Shono, A., and Satoh, K., 2004, "Monodispersed Microbubble Formation Using Microchannel Technique," AIChE J., 50, pp. 3227-3233. (Pubitemid 39664651)
    • (2004) AIChE Journal , vol.50 , Issue.12 , pp. 3227-3233
    • Yasuno, M.1    Sugiura, S.2    Iwamoto, S.3    Nakajima, M.4    Shono, A.5    Satoh, K.6
  • 3
    • 18144420092 scopus 로고    scopus 로고
    • Mechanism for flow-rate controlled breakup in confined geometries: A route to monodisperse emulsions
    • Garstecki, P., Stone, H. A., and Whitesides, G. M., 2005, "Mechanism for Flow-Rate Controlled Breakup in Confined Geometries: A Route to Monodisperse Emulsions," Phys. Rev. Lett., 94, p. 164501.
    • (2005) Phys. Rev. Lett , vol.94 , pp. 164501
    • Garstecki, P.1    Stone, H.A.2    Whitesides, G.M.3
  • 6
    • 78650335629 scopus 로고    scopus 로고
    • Controlled microbubble generation on a compact disk
    • Chakraborty, D., and Chakraborty, S., 2010, "Controlled Microbubble Generation on a Compact Disk," Appl. Phys. Lett., 97, p. 234103.
    • (2010) Appl. Phys. Lett , vol.97 , pp. 234103
    • Chakraborty, D.1    Chakraborty, S.2
  • 7
    • 77952478144 scopus 로고    scopus 로고
    • Formation of bubbles in a multisection flow-focusing junction
    • Hashimoto, M., and Whitesides, G. M., 2011, "Formation of Bubbles in a Multisection Flow-Focusing Junction," Small, 6, pp. 1051-1059.
    • (2011) Small , vol.6 , pp. 1051-1059
    • Hashimoto, M.1    Whitesides, G.M.2
  • 8
    • 79956071588 scopus 로고    scopus 로고
    • Gas-liquid flow stability and bubble formation in non-newtonian fluids in microfluidic flow-focusing devices
    • Fu, T., Ma, Y., Funfschilling, D., and Li, H. Z., 2011, "Gas-Liquid Flow Stability and Bubble Formation in Non-Newtonian Fluids in Microfluidic Flow-Focusing Devices," Microfluid. Nanofluid., 10(5), pp. 1135-1140.
    • (2011) Microfluid. Nanofluid , vol.10 , Issue.5 , pp. 1135-1140
    • Fu, T.1    Ma, Y.2    Funfschilling, D.3    Li, H.Z.4
  • 10
    • 77957358387 scopus 로고    scopus 로고
    • Microbubble-enhanced us in body imaging: What role?
    • Wilson, S. R., and Burns, P. N., 2010, "Microbubble-Enhanced US in Body Imaging: What Role?," Radiology, 257, pp. 24-39.
    • (2010) Radiology , vol.257 , pp. 24-39
    • Wilson, S.R.1    Burns, P.N.2
  • 11
    • 0027460779 scopus 로고
    • Volumetric blood flow measurement with color Doppler ultrasonography: The importance of visual clues
    • Fillinger, M. F., and Schwartz, R. A., 1993, "Volumetric Blood Flow Measurement With Color Doppler Ultrasonography: The Importance of Visual Clues," J. Ultrasound Med., 12, pp. 123-130. (Pubitemid 23102521)
    • (1993) Journal of Ultrasound in Medicine , vol.12 , Issue.3 , pp. 123-130
    • Fillinger, M.F.1    Schwartz, R.A.2
  • 12
    • 2342453302 scopus 로고    scopus 로고
    • Development and validation of echo PIV
    • DOI 10.1007/s00348-003-0743-5
    • Kim, H. B., Hertzberg, J. R., and Shandas, R., 2004, "Development and Validation of Echo PIV," Exp. Fluids, 36, pp. 455-462. (Pubitemid 38589617)
    • (2004) Experiments in Fluids , vol.36 , Issue.3 , pp. 455-462
    • Kim, H.B.1    Hertzberg, J.R.2    Shandas, R.3
  • 13
    • 4544373633 scopus 로고    scopus 로고
    • Noninvasive measurement of steady and pulsating velocity profiles and shear rates in arteries using echo piv: In vitro validation studies
    • Kim, H. B., Hertzberg, J., Lanning, C., and Shandas, R., 2004, "Noninvasive Measurement of Steady and Pulsating Velocity Profiles and Shear Rates in Arteries Using Echo PIV: In Vitro Validation Studies," Ann. Biomed. Eng., 32, pp. 1067-1076.
    • (2004) Ann. Biomed. Eng , vol.32 , pp. 1067-1076
    • Kim, H.B.1    Hertzberg, J.2    Lanning, C.3    Shandas, R.4
  • 16
    • 31144457540 scopus 로고    scopus 로고
    • Microfluidic channel fabrication by PDMS-interface bonding
    • Chow, W. W. Y., Lei, K. F., Shi, G., Li, W. J., and Huang, Q., 2006, "Microfluidic Channel Fabrication by PDMS-Interface Bonding," Smart Mater. Struct., 15, pp. 112-116.
    • (2006) Smart Mater. Struct , vol.15 , pp. 112-116
    • Chow, W.W.Y.1    Lei, K.F.2    Shi, G.3    Li, W.J.4    Huang, Q.5
  • 17
    • 70349897164 scopus 로고    scopus 로고
    • Production of monodispersed micron-sized bubbles at high rates in a microfluidic device
    • Chen, C., Zhu, Y., Leech, P. W., and Manasseh, R., 2009, "Production of Monodispersed Micron-Sized Bubbles at High Rates in a Microfluidic Device," Appl. Phys. Lett., 95, p. 144101.
    • (2009) Appl. Phys. Lett , vol.95 , pp. 144101
    • Chen, C.1    Zhu, Y.2    Leech, P.W.3    Manasseh, R.4
  • 18
    • 33645516543 scopus 로고    scopus 로고
    • Controllable gas-liquid phase flow patterns and monodisperse microbubbles in a microfluidic t-junction device
    • Xu, J. H., Li, S. W., Wang, Y. J., and Luo, G. S., 2006, "Controllable Gas-Liquid Phase Flow Patterns and Monodisperse Microbubbles in a Microfluidic T-Junction Device," Appl. Phys. Lett., 88, p. 133506.
    • (2006) Appl. Phys. Lett , vol.88 , pp. 133506
    • Xu, J.H.1    Li, S.W.2    Wang, Y.J.3    Luo, G.S.4
  • 19
    • 0038541889 scopus 로고    scopus 로고
    • Ordered and disordered patterns in two-phase flows in microchannels
    • Dreyfus, R., Tabeling, P., and Willaime, H., 2003, "Ordered and Disordered Patterns in Two-Phase Flows in Microchannels," Phys. Rev. Lett., 90, p. 144505.
    • (2003) Phys. Rev. Lett , vol.90 , pp. 144505
    • Dreyfus, R.1    Tabeling, P.2    Willaime, H.3
  • 20
    • 33744826280 scopus 로고    scopus 로고
    • Formation of monodisperse microbubbles in a microfluidic device
    • DOI 10.1002/aic.10824
    • Xu, J. H., Li, S. W., Chen, G. G., and Luo, G. S., 2006, "Formation of Monodisperse Microbubbles in a Microfluidic Device," AIChE J., 52, pp. 2254-2259. (Pubitemid 43837624)
    • (2006) AIChE Journal , vol.52 , Issue.6 , pp. 2254-2259
    • Xu, J.H.1    Li, S.W.2    Chen, G.G.3    Luo, G.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.