1
-
-
57349108642
-
Cup inclination angle of greater than 50 degrees increases whole blood concentrations of cobalt and chromium ions after metal-on-metal hip resurfacing
-
Hart AJ, Buddhdev P, Winship P, Faria N, Powell JJ, Skinner JA. Cup inclination angle of greater than 50 degrees increases whole blood concentrations of cobalt and chromium ions after metal-on-metal hip resurfacing. Hip Int 2008, 18(3):212-219.
-
(2008)
Hip Int
, vol.18
, Issue.3
, pp. 212-219
-
-
Hart, A.J.1
Buddhdev, P.2
Winship, P.3
Faria, N.4
Powell, J.J.5
Skinner, J.A.6
-
2
-
-
79952259558
-
The relationship between the angle of version and rate of wear of retrieved metal-on-metal resurfacings: a prospective, CT-based study
-
10.1302/0301-620X.93B3.25545, 21357951
-
Hart AJ, Ilo K, Underwood R, Cann P, Henckel J, Lewis A, Cobb J, Skinner J. The relationship between the angle of version and rate of wear of retrieved metal-on-metal resurfacings: a prospective, CT-based study. J Bone Joint Surg Br 2011, 93(3):315-320. 10.1302/0301-620X.93B3.25545, 21357951.
-
(2011)
J Bone Joint Surg Br
, vol.93
, Issue.3
, pp. 315-320
-
-
Hart, A.J.1
Ilo, K.2
Underwood, R.3
Cann, P.4
Henckel, J.5
Lewis, A.6
Cobb, J.7
Skinner, J.8
-
3
-
-
77649206363
-
Analysis of wear of retrieved metal-on-metal hip resurfacing implants revised due to pseudotumours
-
10.1302/0301-620X.92B3.23281, 20190305
-
Kwon YM, Glyn-Jones S, Simpson DJ, Kamali A, McLardy-Smith P, Gill HS, Murray DW. Analysis of wear of retrieved metal-on-metal hip resurfacing implants revised due to pseudotumours. J Bone Joint Surg Br 2010, 92(3):356-361. 10.1302/0301-620X.92B3.23281, 20190305.
-
(2010)
J Bone Joint Surg Br
, vol.92
, Issue.3
, pp. 356-361
-
-
Kwon, Y.M.1
Glyn-Jones, S.2
Simpson, D.J.3
Kamali, A.4
McLardy-Smith, P.5
Gill, H.S.6
Murray, D.W.7
-
4
-
-
53649092535
-
The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip
-
10.1302/0301-620X.90B9.20785, 18757952
-
Langton DJ, Jameson SS, Joyce TJ, Webb J, Nargol AV. The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip. J Bone Joint Surg Br 2008, 90(9):1143-1151. 10.1302/0301-620X.90B9.20785, 18757952.
-
(2008)
J Bone Joint Surg Br
, vol.90
, Issue.9
, pp. 1143-1151
-
-
Langton, D.J.1
Jameson, S.S.2
Joyce, T.J.3
Webb, J.4
Nargol, A.V.5
-
5
-
-
53649088948
-
Revision of metal-on-metal resurfacing arthroplasty of the hip: the influence of malpositioning of the components
-
10.1302/0301-620X.90B9.19891, 18757954
-
De Haan R, Campbell PA, Su EP, De Smet KA. Revision of metal-on-metal resurfacing arthroplasty of the hip: the influence of malpositioning of the components. J Bone Joint Surg Br 2008, 90(9):1158-1163. 10.1302/0301-620X.90B9.19891, 18757954.
-
(2008)
J Bone Joint Surg Br
, vol.90
, Issue.9
, pp. 1158-1163
-
-
De Haan, R.1
Campbell, P.A.2
Su, E.P.3
De Smet, K.A.4
-
6
-
-
77955377701
-
Optimal acetabular orientation for hip resurfacing
-
10.1302/0301-620X.92B8.24194, 20675749
-
Grammatopoulos G, Pandit H, Glyn-Jones S, McLardy-Smith P, Gundle R, Whitwell D, Gill HS, Murray DW. Optimal acetabular orientation for hip resurfacing. J Bone Joint Surg Br 2010, 92(8):1072-1078. 10.1302/0301-620X.92B8.24194, 20675749.
-
(2010)
J Bone Joint Surg Br
, vol.92
, Issue.8
, pp. 1072-1078
-
-
Grammatopoulos, G.1
Pandit, H.2
Glyn-Jones, S.3
McLardy-Smith, P.4
Gundle, R.5
Whitwell, D.6
Gill, H.S.7
Murray, D.W.8
-
7
-
-
79959571997
-
Surgical variables influence metal ion levels after hip resurfacing
-
10.1007/s11999-010-1636-6, 3094610, 20972653
-
Desy NM, Bergeron SG, Petit A, Huk OL, Antoniou J. Surgical variables influence metal ion levels after hip resurfacing. Clin Orthop Relat Res 2011, 469(6):1635-1641. 10.1007/s11999-010-1636-6, 3094610, 20972653.
-
(2011)
Clin Orthop Relat Res
, vol.469
, Issue.6
, pp. 1635-1641
-
-
Desy, N.M.1
Bergeron, S.G.2
Petit, A.3
Huk, O.L.4
Antoniou, J.5
-
8
-
-
0038728365
-
Iliopsoas impingement on the acetabular component: radiologic and computed tomography findings of a rare hip prosthesis complication in eight cases
-
10.1097/00004728-200303000-00014, 12703010
-
Cyteval C, Sarrabère MP, Cottin A, Assi C, Morcos L, Maury P, Taourel P. Iliopsoas impingement on the acetabular component: radiologic and computed tomography findings of a rare hip prosthesis complication in eight cases. J Comput Assist Tomogr 2003, 27(2):183-188. 10.1097/00004728-200303000-00014, 12703010.
-
(2003)
J Comput Assist Tomogr
, vol.27
, Issue.2
, pp. 183-188
-
-
Cyteval, C.1
Sarrabère, M.P.2
Cottin, A.3
Assi, C.4
Morcos, L.5
Maury, P.6
Taourel, P.7
-
9
-
-
48349139258
-
Limited range of motion of hip resurfacing arthroplasty due to unfavorable ratio of prosthetic head size and femoral neck diameter
-
10.1080/17453670810016803, 19085490
-
Kluess D, Zietz C, Lindner T, Mittelmeier W, Schmitz KP, Bader R. Limited range of motion of hip resurfacing arthroplasty due to unfavorable ratio of prosthetic head size and femoral neck diameter. Acta Orthop 2008, 79(6):748-754. 10.1080/17453670810016803, 19085490.
-
(2008)
Acta Orthop
, vol.79
, Issue.6
, pp. 748-754
-
-
Kluess, D.1
Zietz, C.2
Lindner, T.3
Mittelmeier, W.4
Schmitz, K.P.5
Bader, R.6
-
10
-
-
34547783638
-
Impingement with total hip replacement
-
10.2106/JBJS.F.01313, 17671025
-
Malik A, Maheshwari A, Dorr LD. Impingement with total hip replacement. J Bone Joint Surg Am 2007, 89(8):1832-1842. 10.2106/JBJS.F.01313, 17671025.
-
(2007)
J Bone Joint Surg Am
, vol.89
, Issue.8
, pp. 1832-1842
-
-
Malik, A.1
Maheshwari, A.2
Dorr, L.D.3
-
11
-
-
0027479381
-
The definition and measurement of acetabular orientation
-
Murray DW. The definition and measurement of acetabular orientation. J Bone Joint Surg Br 1993, 75(2):228-232.
-
(1993)
J Bone Joint Surg Br
, vol.75
, Issue.2
, pp. 228-232
-
-
Murray, D.W.1
-
12
-
-
84868300314
-
The reliability and variation of acetabular component anteversion measurements from cross-table lateral radiographs
-
Nunley RM, Keeney JA, Zhu J, Clohisy JC, Barrack RL. The reliability and variation of acetabular component anteversion measurements from cross-table lateral radiographs. J Arthroplasty 2011, 26(6 Suppl):84-87.
-
(2011)
J Arthroplasty
, vol.26
, Issue.6 SUPPL
, pp. 84-87
-
-
Nunley, R.M.1
Keeney, J.A.2
Zhu, J.3
Clohisy, J.C.4
Barrack, R.L.5
-
13
-
-
77953128194
-
Cup anteversion in hip resurfacing: validation of EBRA and the presentation of a simple clinical grading system
-
10.1016/j.arth.2009.08.020, 20022454
-
Langton DJ, Sprowson AP, Mahadeva D, Bhatnagar S, Holland JP, Nargol AV. Cup anteversion in hip resurfacing: validation of EBRA and the presentation of a simple clinical grading system. J Arthroplasty 2010, 25(4):607-613. 10.1016/j.arth.2009.08.020, 20022454.
-
(2010)
J Arthroplasty
, vol.25
, Issue.4
, pp. 607-613
-
-
Langton, D.J.1
Sprowson, A.P.2
Mahadeva, D.3
Bhatnagar, S.4
Holland, J.P.5
Nargol, A.V.6
-
14
-
-
0015632760
-
Prosthetic hip angulation
-
McLaren RH. Prosthetic hip angulation. Radiology 1973, 107:705-706.
-
(1973)
Radiology
, vol.107
, pp. 705-706
-
-
McLaren, R.H.1
-
15
-
-
1942422237
-
A simplified method to determine acetabular cup anteversion from plain radiographs
-
10.1016/j.arth.2003.10.016, 15067657
-
Widmer KH. A simplified method to determine acetabular cup anteversion from plain radiographs. J Arthroplasty 2004, 19:387-390. 10.1016/j.arth.2003.10.016, 15067657.
-
(2004)
J Arthroplasty
, vol.19
, pp. 387-390
-
-
Widmer, K.H.1
-
16
-
-
33646079156
-
Position of the acetabular cup - accuracy of radiographic calculation compared to CT-based measurement
-
10.1016/j.ejrad.2005.10.003, 16289687
-
Kalteis T, Handel M, Herold T, Perlick L, Paetzel C, Grifka J. Position of the acetabular cup - accuracy of radiographic calculation compared to CT-based measurement. Eur J Radiol 2006, 58:294-300. 10.1016/j.ejrad.2005.10.003, 16289687.
-
(2006)
Eur J Radiol
, vol.58
, pp. 294-300
-
-
Kalteis, T.1
Handel, M.2
Herold, T.3
Perlick, L.4
Paetzel, C.5
Grifka, J.6
-
17
-
-
79955799269
-
Acetabular anteversion with CT in supine, simulated standing, and sitting positions in a THA patient population
-
10.1007/s11999-010-1732-7, 3048248, 21161739
-
Lazennec JY, Boyer P, Gorin M, Catonné Y, Rousseau MA. Acetabular anteversion with CT in supine, simulated standing, and sitting positions in a THA patient population. Clin Orthop Relat Res 2011, 469(4):1103-1109. 10.1007/s11999-010-1732-7, 3048248, 21161739.
-
(2011)
Clin Orthop Relat Res
, vol.469
, Issue.4
, pp. 1103-1109
-
-
Lazennec, J.Y.1
Boyer, P.2
Gorin, M.3
Catonné, Y.4
Rousseau, M.A.5
-
18
-
-
3042657286
-
A new CT method for measuring cup orientation after total hip arthroplasty: a study of 10 patients
-
10.1080/00016470410001169, 15260415
-
Olivecrona H, Weidenhielm L, Olivecrona L, Beckman MO, Stark A, Noz ME, Maguire GQ, Zeleznik MP, Svensson L, Jonson T. A new CT method for measuring cup orientation after total hip arthroplasty: a study of 10 patients. Acta Orthop Scand 2004, 75:252-260. 10.1080/00016470410001169, 15260415.
-
(2004)
Acta Orthop Scand
, vol.75
, pp. 252-260
-
-
Olivecrona, H.1
Weidenhielm, L.2
Olivecrona, L.3
Beckman, M.O.4
Stark, A.5
Noz, M.E.6
Maguire, G.Q.7
Zeleznik, M.P.8
Svensson, L.9
Jonson, T.10
-
19
-
-
74349097934
-
Large ball metal on metal hips obscure cup angle measurement on plain radiographs
-
Hart AJ, Dandachli W, Schlueter-Brust K, Henckel J, Cobb J. Large ball metal on metal hips obscure cup angle measurement on plain radiographs. Hip Int 2009, 19(4):323-329.
-
(2009)
Hip Int
, vol.19
, Issue.4
, pp. 323-329
-
-
Hart, A.J.1
Dandachli, W.2
Schlueter-Brust, K.3
Henckel, J.4
Cobb, J.5
|