메뉴 건너뛰기




Volumn 79, Issue 6, 2008, Pages 748-754

Limited range of motion of hip resurfacing arthroplasty due to unfavorable ratio of prosthetic head size and femoral neck diameter

Author keywords

[No Author keywords available]

Indexed keywords

ACETABULUM; ARTICLE; COMPUTER AIDED DESIGN; COMPUTER ASSISTED TOMOGRAPHY; DATA ANALYSIS; FEMUR HEAD; FEMUR NECK; FEMUR NECK FRACTURE; HIP ARTHROPLASTY; HIP DISLOCATION; HIP PROSTHESIS; HIP RESURFACING ARTHROPLASTY; JOINT MOBILITY; PROSTHESIS LOOSENING; RANGE OF MOTION; RISK ASSESSMENT; THREE DIMENSIONAL IMAGING; TOTAL HIP PROSTHESIS;

EID: 48349139258     PISSN: 17453674     EISSN: 17453682     Source Type: Journal    
DOI: 10.1080/17453670810016803     Document Type: Article
Times cited : (62)

References (28)
  • 2
    • 4544312502 scopus 로고    scopus 로고
    • Fracture of the neck of the femur after surface arthroplasty of the hip
    • Amstutz H C, Campbell P A, Le Duff M J. Fracture of the neck of the femur after surface arthroplasty of the hip. J Bone Joint Surg (Am) 2004b; 86 (9): 1874-7.
    • (2004) J Bone Joint Surg (Am) , vol.86 , Issue.9 , pp. 1874-1877
    • Amstutz, H.C.1    Campbell, P.A.2    Le Duff, M.J.3
  • 4
    • 33846818683 scopus 로고    scopus 로고
    • Results of metal-on-metal hybrid hip resurfacing for Crowe type-I and II developmental dysplasia
    • Amstutz H C, Antoniades J T, Le Duff M J. Results of metal-on-metal hybrid hip resurfacing for Crowe type-I and II developmental dysplasia. J Bone Joint Surg (Am) 2007; 89 (2): 339-46.
    • (2007) J Bone Joint Surg (Am) , vol.89 , Issue.2 , pp. 339-346
    • Amstutz, H.C.1    Antoniades, J.T.2    Le Duff, M.J.3
  • 5
    • 0036301782 scopus 로고    scopus 로고
    • Computer-based motion simulation of total hip prostheses with ceramic-on-ceramic wear couple. Analysis of implant design andorientation as influence parameters
    • Bader R, Steinhauser E, Gradinger R, Willmann G, Mittelmeier W. Computer-based motion simulation of total hip prostheses with ceramic-on-ceramic wear couple. Analysis of implant design andorientation as influence parameters. Z Orthop Ihre Grenzgeb 2002; 140 (3): 310-6.
    • (2002) Z Orthop Ihre Grenzgeb , vol.140 , Issue.3 , pp. 310-316
    • Bader, R.1    Steinhauser, E.2    Gradinger, R.3    Willmann, G.4    Mittelmeier, W.5
  • 6
    • 2942595992 scopus 로고    scopus 로고
    • Method for the evaluation of factors influencing the dislocation stability of total hip endoprotheses
    • Bader R, Scholz R, Steinhauser E, Busch R, Mittelmeier W. Method for the evaluation of factors influencing the dislocation stability of total hip endoprotheses. Biomed Tech 2004a; 49 (5): 137-44.
    • (2004) Biomed Tech , vol.49 , Issue.5 , pp. 137-144
    • Bader, R.1    Scholz, R.2    Steinhauser, E.3    Busch, R.4    Mittelmeier, W.5
  • 7
    • 4444309697 scopus 로고    scopus 로고
    • The influence of head and neck geometry on stability of total hip replacement: A mechanical test study
    • Bader R, Scholz R, Steinhauser E, Zimmermann S, Busch R, Mittelmeier W. The influence of head and neck geometry on stability of total hip replacement: a mechanical test study. Acta Orthop Scand 2004b; 75 (4): 415-21.
    • (2004) Acta Orthop Scand , vol.75 , Issue.4 , pp. 415-421
    • Bader, R.1    Scholz, R.2    Steinhauser, E.3    Zimmermann, S.4    Busch, R.5    Mittelmeier, W.6
  • 10
    • 23744506543 scopus 로고    scopus 로고
    • Resurfacing hip prostheses revisited: Failure analysis during a 16-year follow-up
    • Duijsens A W, Keizer S, Vliet-Vlieland T, Nelissen R G. Resurfacing hip prostheses revisited: failure analysis during a 16-year follow-up. Intern Orthop 2005; 29 (4): 224-8.
    • (2005) Intern Orthop , vol.29 , Issue.4 , pp. 224-228
    • Duijsens, A.W.1    Keizer, S.2    Vliet-Vlieland, T.3    Nelissen, R.G.4
  • 12
    • 34250633994 scopus 로고    scopus 로고
    • Finite-Element-analysis into impingement-related implant failure of total hip replacement
    • Kluess D, Martin H, Mittelmeier W, Schmitz K, Bader R. Finite-Element-analysis into impingement-related implant failure of total hip replacement. Materials Testing 2007a; 49 (6): 330-6.
    • (2007) Materials Testing , vol.49 , Issue.6 , pp. 330-336
    • Kluess, D.1    Martin, H.2    Mittelmeier, W.3    Schmitz, K.4    Bader, R.5
  • 13
    • 33846110261 scopus 로고    scopus 로고
    • Influence of femoral head size on impingement, dislocation and stress distribution in total hip replacement
    • Kluess D, Martin H, Mittelmeier W, Schmitz K P, Bader R. Influence of femoral head size on impingement, dislocation and stress distribution in total hip replacement. Med Eng Phys 2007b; 29 (4): 465-71.
    • (2007) Med Eng Phys , vol.29 , Issue.4 , pp. 465-471
    • Kluess, D.1    Martin, H.2    Mittelmeier, W.3    Schmitz, K.P.4    Bader, R.5
  • 14
    • 0032801048 scopus 로고    scopus 로고
    • The effect of acetabular cup orientations on limiting hip rotation
    • Kummer F J, Shah S, Iyer S, DiCesare P E. The effect of acetabular cup orientations on limiting hip rotation. J Arthroplasty 1999; 14 (4): 509-13.
    • (1999) J Arthroplasty , vol.14 , Issue.4 , pp. 509-513
    • Kummer, F.J.1    Shah, S.2    Iyer, S.3    DiCesare, P.E.4
  • 16
    • 17044433022 scopus 로고    scopus 로고
    • Hydroxyapatite-coated femoral implant in metal-on-metal resurfacing hip arthroplasty: Minimum of two years follow-up
    • Lilikakis A K, Vowler S L, Villar R N. Hydroxyapatite-coated femoral implant in metal-on-metal resurfacing hip arthroplasty: minimum of two years follow-up. Orthop Clin North Am 2005; 36 (2): 215-22.
    • (2005) Orthop Clin North Am , vol.36 , Issue.2 , pp. 215-222
    • Lilikakis, A.K.1    Vowler, S.L.2    Villar, R.N.3
  • 18
    • 0037398768 scopus 로고    scopus 로고
    • Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation
    • Nadzadi M E, Pedersen D R, Yack H J, Callaghan J J, Brown T D. Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation. J Biomech 2003; 36 (4): 577-91.
    • (2003) J Biomech , vol.36 , Issue.4 , pp. 577-591
    • Nadzadi, M.E.1    Pedersen, D.R.2    Yack, H.J.3    Callaghan, J.J.4    Brown, T.D.5
  • 22
    • 57749093103 scopus 로고    scopus 로고
    • Schmalzried T P. Resurfacing Arthroplasty: Time to consider it again? Yes. Proceedings of the AAOS 2007: 8.
    • Schmalzried T P. Resurfacing Arthroplasty: Time to consider it again? Yes. Proceedings of the AAOS 2007: 8.
  • 24
    • 17044401726 scopus 로고    scopus 로고
    • Complications associated with hip resurfacing arthroplasty
    • Shimmin A J, Bare J, Back D L. Complications associated with hip resurfacing arthroplasty. Orthop Clin North Am 2005; 36 (2): 187-93.
    • (2005) Orthop Clin North Am , vol.36 , Issue.2 , pp. 187-193
    • Shimmin, A.J.1    Bare, J.2    Back, D.L.3
  • 26
    • 4043133785 scopus 로고    scopus 로고
    • Implementing capsule representation in a total hip dislocation finite element model
    • Stewart K J, Pedersen D R, Callaghan J J, Brown T D. Implementing capsule representation in a total hip dislocation finite element model. Iowa Orthop J 2004; 24: 1-8.
    • (2004) Iowa Orthop J , vol.24 , pp. 1-8
    • Stewart, K.J.1    Pedersen, D.R.2    Callaghan, J.J.3    Brown, T.D.4
  • 28
    • 33749477485 scopus 로고    scopus 로고
    • Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty
    • Witzleb W-C, Ziegler J, Krummenauer F, Neumeister V, Guenther K-P. Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty. Acta Orthop 2006; 77 (5): 697-705.
    • (2006) Acta Orthop , vol.77 , Issue.5 , pp. 697-705
    • Witzleb, W.-C.1    Ziegler, J.2    Krummenauer, F.3    Neumeister, V.4    Guenther, K.-P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.