메뉴 건너뛰기




Volumn 28, Issue 2, 2013, Pages 167-177

Highly sensitive gold-overoxidized polypyrrole nanocomposite immunosensor for antitransglutaminase antibody

Author keywords

Antitransglutaminase antibodies; atomic force microscopy; coeliac disease; cyclic voltammetry; electrochemical impedance spectroscopy; Fourier transform infrared spectroscopy; transglutaminase

Indexed keywords

COELIAC DISEASE; ELECTROCHEMICAL DETERMINATION; EXCHANGE CURRENT DENSITIES; HETEROGENEOUS RATE CONSTANT; IMPEDIMETRIC IMMUNOSENSORS; OVEROXIDIZED POLYPYRROLE FILMS; POLYPYRROLE NANOCOMPOSITES; TRANSGLUTAMINASES;

EID: 84875872905     PISSN: 08839115     EISSN: 15308030     Source Type: Journal    
DOI: 10.1177/0883911512472277     Document Type: Article
Times cited : (11)

References (28)
  • 2
    • 56449105830 scopus 로고    scopus 로고
    • An electrochemical DNA biosensor developed on a nanocomposite platform of gold and poly(propyleneimine) dendrimer
    • Arotiba O, Owino J, Songa E, et al. An electrochemical DNA biosensor developed on a nanocomposite platform of gold and poly(propyleneimine) dendrimer. Sensors. 2008 ; 8 (11). 6791-6809
    • (2008) Sensors , vol.8 , Issue.11 , pp. 6791-6809
    • Arotiba, O.1    Owino, J.2    Songa, E.3
  • 3
    • 58149194803 scopus 로고    scopus 로고
    • Electrochemical immunosensor based on polythionine/gold nanoparticles for the determination of aflatoxin B1
    • Owino JHO, Arotiba OA, Hendricks N, et al. Electrochemical immunosensor based on polythionine/gold nanoparticles for the determination of aflatoxin B1. Sensors. 2008 ; 8 (12). 8262-8274
    • (2008) Sensors , vol.8 , Issue.12 , pp. 8262-8274
    • Owino, J.H.O.1    Arotiba, O.A.2    Hendricks, N.3
  • 4
    • 33847746205 scopus 로고    scopus 로고
    • Amperometric glucose biosensor based on electrodeposition of platinum nanoparticles onto covalently immobilized carbon nanotube electrode
    • DOI 10.1016/j.talanta.2006.09.013, PII S0039914006006321
    • Chu X, Duan DX, Shen GL, et al. Amperometric glucose biosensor based on electrodeposition of platinum nanoparticles onto covalently immobilized carbon nanotube electrode. Talanta. 2007 ; 71 (5). 2040-2047 (Pubitemid 46386195)
    • (2007) Talanta , vol.71 , Issue.5 , pp. 2040-2047
    • Chu, X.1    Duan, D.2    Shen, G.3    Yu, R.4
  • 5
    • 55349143214 scopus 로고    scopus 로고
    • A simple quartz crystal microbalance nucleic acid sensor for detection of telomerase
    • Öztürk K, Durusoy M, Piskin E. A simple quartz crystal microbalance nucleic acid sensor for detection of telomerase. J Bioact Compat Polym. 2008 ; 23: 579-593
    • (2008) J Bioact Compat Polym , vol.23 , pp. 579-593
    • Öztürk, K.1    Durusoy, M.2    Piskin, E.3
  • 7
    • 35348936121 scopus 로고    scopus 로고
    • Amperometric detection of triazophos pesticide using acetylcholinesterase biosensor based on multiwall carbon nanotube-chitosan matrix
    • DOI 10.1016/j.snb.2007.05.006, PII S0925400507003322
    • Du D, Huang X, Cai J, et al. Amperometric detection of triazophos pesticide using acetylcholinesterase biosensor based on multiwall carbon nanotube-chitosan matrix. Sens Actuators B Chem. 2007 ; 127 (2). 531-535 (Pubitemid 47599911)
    • (2007) Sensors and Actuators, B: Chemical , vol.127 , Issue.2 , pp. 531-535
    • Du, D.1    Huang, X.2    Cai, J.3    Zhang, A.4
  • 8
    • 0035341205 scopus 로고    scopus 로고
    • Fabrication of ultra-thin polypyrrole-glucose oxidase film from supporting electrolyte-free monomer solution for potentiometric biosensing of glucose
    • DOI 10.1016/S0956-5663(00)00117-2, PII S0956566300001172
    • Adeloju SB, Moline AN. Fabrication of ultra-thin polypyrrole-glucose oxidase film from supporting electrolyte-free monomer solution for potentiometric biosensing of glucose. Biosens Bioelectron. 2001 ; 16 (13). 133-139 (Pubitemid 32406272)
    • (2001) Biosensors and Bioelectronics , vol.16 , Issue.3 , pp. 133-139
    • Adeloju, S.B.1    Moline, A.N.2
  • 9
    • 0036883541 scopus 로고    scopus 로고
    • Hydrogen peroxide sensitive amperometric biosensor based on horseradish peroxidase entrapped in a polypyrrole electrode
    • DOI 10.1016/S0956-5663(02)00083-0, PII S0956566302000830
    • Razola SS, Ruiz BL, Diez NM, et al. Hydrogen peroxide sensitive amperometric biosensor based on horseradish peroxidase entrapped in a polypyrrole electrode. Biosens Bioelectron. 2002 ; 17 (11-12). 921-928 (Pubitemid 35232466)
    • (2002) Biosensors and Bioelectronics , vol.17 , Issue.11-12 , pp. 921-928
    • Razola S.Serradilla1    Ruiz B.Lopez2    Diez N.Mora3    Mark Jr., H.B.4    Kauffmann, J.-M.5
  • 10
    • 36549004634 scopus 로고    scopus 로고
    • Biomolecules-carbon nanotubes doped conducting polymer nanocomposites and their sensor application
    • DOI 10.1016/j.talanta.2007.08.047, PII S0039914007006145, Micro- and Nanotechnology in Electrochemical Detection Science - dedicated to Professor Joseph Wang on the occasion of his 60th birthday MNED 2007 SI
    • Kum MC, Joshi KA, Chen W, et al. Biomolecules-carbon nanotubes doped conducting polymer nanocomposites and their sensor application. Talanta. 2007 ; 74 (3). 370-375 (Pubitemid 350192530)
    • (2007) Talanta , vol.74 , Issue.3 , pp. 370-375
    • Kum, M.C.1    Joshi, K.A.2    Chen, W.3    Myung, N.V.4    Mulchandani, A.5
  • 11
    • 34249866564 scopus 로고    scopus 로고
    • Simultaneous determination of dopamine and serotonin on gold nanocluster/overoxidized-polypyrrole composite modified glassy carbon electrode
    • DOI 10.1016/j.snb.2007.01.021, PII S0925400507000226
    • Li J, Lin X. Simultaneous determination of dopamine and serotonin on gold nanocluster/overoxidized-polypyrrole composite modified glassy carbon electrode. Sens Actuators B Chem. 2007 ; 124 (2). 486-493 (Pubitemid 46874037)
    • (2007) Sensors and Actuators, B: Chemical , vol.124 , Issue.2 , pp. 486-493
    • Li, J.1    Lin, X.2
  • 12
    • 0027983036 scopus 로고
    • Molecular imprinting
    • DOI 10.1016/0968-0004(94)90166-X
    • Mosbach K. Molecular imprinting. Trends Biochem Sci. 1994 ; 19 (1). 9-14 (Pubitemid 24028724)
    • (1994) Trends in Biochemical Sciences , vol.19 , Issue.1 , pp. 9-14
    • Mosbach, K.1
  • 13
    • 0026424540 scopus 로고
    • Effect of electrode substrate on the morphology and selectivity of overoxidized polypyrrole films
    • Witkowski A, Freund MS, Brajter-Toth A. Effect of electrode substrate on the morphology and selectivity of overoxidized polypyrrole films. Anal Chem. 1991 ; 63 (6). 622-626
    • (1991) Anal Chem , vol.63 , Issue.6 , pp. 622-626
    • Witkowski, A.1    Freund, M.S.2    Brajter-Toth, A.3
  • 14
    • 18944395914 scopus 로고    scopus 로고
    • Electrochemical biosensors: Recommended definitions and classification
    • Theavenot DR, Toth TK, Durst RA, et al. Electrochemical biosensors: recommended definitions and classification. Pure Appl Chem. 1999 ; 71 (12). 2333-2348
    • (1999) Pure Appl Chem , vol.71 , Issue.12 , pp. 2333-2348
    • Theavenot, D.R.1    Toth, T.K.2    Durst, R.A.3
  • 15
    • 70350043517 scopus 로고    scopus 로고
    • Molecularly imprinted microgels as enzyme inhibitors
    • Cutivet A, Schembri C, Kovensky J, et al. Molecularly imprinted microgels as enzyme inhibitors. J Am Chem Soc. 2009 ; 131 (41). 14699-14702
    • (2009) J Am Chem Soc , vol.131 , Issue.41 , pp. 14699-14702
    • Cutivet, A.1    Schembri, C.2    Kovensky, J.3
  • 16
    • 35148850459 scopus 로고    scopus 로고
    • Electrospun nanofibers surface-modified with fluorescent proteins
    • Choi JS, Yoo HS. Electrospun nanofibers surface-modified with fluorescent proteins. J Bioact Compat Polym. 2007 ; 22 (5). 508-524
    • (2007) J Bioact Compat Polym , vol.22 , Issue.5 , pp. 508-524
    • Choi, J.S.1    Yoo, H.S.2
  • 17
    • 11144296968 scopus 로고    scopus 로고
    • Study on the immobilization of anti-IgG on Au-colloid modified gold electrode via potentiometric immunosensor, cyclic voltammetry, and electrochemical impedance techniques
    • DOI 10.1016/j.colsurfb.2004.10.022, PII S0927776504003261
    • Fu Y, Yuan R, Tang D, et al. Study on the immobilization of anti-IgG on Au-colloid modified gold electrode via potentiometric immunosensor, cyclic voltammetry, and electrochemical impedance techniques. Colloids Surf B Biointerfaces. 2005 ; 40(1): 61-66 (Pubitemid 40023421)
    • (2005) Colloids and Surfaces B: Biointerfaces , vol.40 , Issue.1 , pp. 61-66
    • Fu, Y.1    Yuan, R.2    Tang, D.3    Chai, Y.4    Xu, L.5
  • 18
    • 53649107422 scopus 로고    scopus 로고
    • An amperometric immunosensor with a DNA polyion complex membrane/gold nanoparticles-backbone for antibody immobilization
    • Li N, Zhao H, Yuan R, et al. An amperometric immunosensor with a DNA polyion complex membrane/gold nanoparticles-backbone for antibody immobilization. Electrochem Acta. 2008 ; 54 (2). 235-241
    • (2008) Electrochem Acta , vol.54 , Issue.2 , pp. 235-241
    • Li, N.1    Zhao, H.2    Yuan, R.3
  • 19
    • 30144443853 scopus 로고    scopus 로고
    • Enzymatic determination of biogenic amines with transglutaminase
    • Punakivi K, Smolander M, Niku-Paavola ML, et al. Enzymatic determination of biogenic amines with transglutaminase. Talanta. 2005 ; 68 (3). 1040-1045
    • (2005) Talanta , vol.68 , Issue.3 , pp. 1040-1045
    • Punakivi, K.1    Smolander, M.2    Niku-Paavola, M.L.3
  • 20
    • 0022014283 scopus 로고
    • Electrochemical and electron spectroscopic studies of highly polished glassy carbon electrodes
    • Kamau GN, Willis WS, Rusling JF. Electrochemical and electron spectroscopic studies of highly polished glassy carbon electrodes. Anal Chem. 1985 ; 57 (2). 545-551
    • (1985) Anal Chem , vol.57 , Issue.2 , pp. 545-551
    • Kamau, G.N.1    Willis, W.S.2    Rusling, J.F.3
  • 21
    • 34447647295 scopus 로고    scopus 로고
    • Structure-based design of α-amido aldehyde containing gluten peptide analogues as modulators of HLA-DQ2 and transglutaminase 2
    • DOI 10.1016/j.bmc.2007.06.020, PII S0968089607005433
    • Siegel M, Xia J, Khosla C. Structure-based design of α-amido aldehyde containing gluten peptide analogues as modulators of HLA-DQ2 and transglutaminase 2. Bioorg Med Chem. 2007 ; 15 (18). 6253-6261 (Pubitemid 47088951)
    • (2007) Bioorganic and Medicinal Chemistry , vol.15 , Issue.18 , pp. 6253-6261
    • Siegel, M.1    Xia, J.2    Khosla, C.3
  • 22
    • 53649107422 scopus 로고    scopus 로고
    • An amperometric immunosensor with a DNA polyion complex membrane/gold nanoparticles-backbone for antibody immobilization
    • Na Li, Hongwen Z, Ruo Y, et al. An amperometric immunosensor with a DNA polyion complex membrane/gold nanoparticles-backbone for antibody immobilization. Electrochem Acta. 2008 ; 54 (2). 235-241
    • (2008) Electrochem Acta , vol.54 , Issue.2 , pp. 235-241
    • Li, N.1    Hongwen, Z.2    Ruo, Y.3
  • 25
    • 66749117817 scopus 로고    scopus 로고
    • Controlled synthesis of large-area and patterned electrochemically reduced graphene oxide films
    • Zhou M, Wang Y, Zhai Y, et al. Controlled synthesis of large-area and patterned electrochemically reduced graphene oxide films. Chemistry. 2009 ; 15 (25). 6116-6120
    • (2009) Chemistry , vol.15 , Issue.25 , pp. 6116-6120
    • Zhou, M.1    Wang, Y.2    Zhai, Y.3
  • 26
    • 2542476501 scopus 로고    scopus 로고
    • Acoustic biosensor for monitoring antibody immobilization and neurotransmitter GABA in real-time
    • Zhou A, Muthuswamy J. Acoustic biosensor for monitoring antibody immobilization and neurotransmitter GABA in real-time. Sens Actuators B Chem. 2004 ; 101 (1-2). 8-19
    • (2004) Sens Actuators B Chem , vol.101 , Issue.12 , pp. 8-19
    • Zhou, A.1    Muthuswamy, J.2
  • 27
    • 0001004779 scopus 로고    scopus 로고
    • Electrostatic layer-by-layer assembly of polycation and DNA multilayer films by real-time surface plasmon resonance technique
    • Pei RJ, Cui XQ, Yang XR, et al. Electrostatic layer-by-layer assembly of polycation and DNA multilayer films by real-time surface plasmon resonance technique. Chinese J Chem. 2001 ; 19 (4). 433-435
    • (2001) Chinese J Chem , vol.19 , Issue.4 , pp. 433-435
    • Pei, R.J.1    Cui, X.Q.2    Yang, X.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.