메뉴 건너뛰기




Volumn 15, Issue 2, 2013, Pages 227-233

Clinical outcome of dental implants placed with high insertion torques (Up to 176Ncm)

Author keywords

Crestal bone; Implant; Insertion torque

Indexed keywords

ADULT; AGED; ALVEOLAR BONE LOSS; ARTICLE; BONE REGENERATION; CLASSIFICATION; EDENTULOUSNESS; FEMALE; FOLLOW UP; HUMAN; JAW; MALE; MANDIBLE; MAXILLA; METHODOLOGY; MIDDLE AGED; PATHOLOGY; PHYSIOLOGY; PROSPECTIVE STUDY; TOOTH IMPLANT; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TORQUE; TREATMENT OUTCOME; VERY ELDERLY;

EID: 84875808868     PISSN: 15230899     EISSN: 17088208     Source Type: Journal    
DOI: 10.1111/j.1708-8208.2011.00351.x     Document Type: Article
Times cited : (73)

References (43)
  • 1
    • 0034139407 scopus 로고    scopus 로고
    • Considerations preliminary to the application of early and immediate loading protocols in dental implantology
    • Szmukler-Moncler S, Piatelli A, Favero GA, Dubruille JH. Considerations preliminary to the application of early and immediate loading protocols in dental implantology. Clin Oral Implants Res 2000; 11:12-25.
    • (2000) Clin Oral Implants Res , vol.11 , pp. 12-25
    • Szmukler-Moncler, S.1    Piatelli, A.2    Favero, G.A.3    Dubruille, J.H.4
  • 2
    • 0033140443 scopus 로고    scopus 로고
    • In vivo bone response to biomechanical loading at the bone/dental-implant interface
    • Brunski JB. In vivo bone response to biomechanical loading at the bone/dental-implant interface. Adv Dent Res 1999; 13:99-119.
    • (1999) Adv Dent Res , vol.13 , pp. 99-119
    • Brunski, J.B.1
  • 3
    • 0042012798 scopus 로고    scopus 로고
    • Immediate functional loading of Brånemark system implants with enhanced initial stability: a prospective 1- to 2-year clinical and radiographic study
    • Calandriello R, Tomatis M, Rangert B. Immediate functional loading of Brånemark system implants with enhanced initial stability: a prospective 1- to 2-year clinical and radiographic study. Clin Implant Dent Relat Res 2003; 5:10-20.
    • (2003) Clin Implant Dent Relat Res , vol.5 , pp. 10-20
    • Calandriello, R.1    Tomatis, M.2    Rangert, B.3
  • 4
    • 0345304945 scopus 로고    scopus 로고
    • Radiographic bone density around immediately loaded oral implants. A case series
    • Barone A, Covani U, Cornelini R, Gherlone E. Radiographic bone density around immediately loaded oral implants. A case series. Clin Oral Implants Res 2003; 14:610-613.
    • (2003) Clin Oral Implants Res , vol.14 , pp. 610-613
    • Barone, A.1    Covani, U.2    Cornelini, R.3    Gherlone, E.4
  • 5
    • 0036362362 scopus 로고    scopus 로고
    • Histologic and histomporphmetric evaluation of peri-implant bone subjected to immediate loading: an experimental study with Macaca fascicularis
    • Romanos GE, Toh CG, Siar CH, Swaminathan D. Histologic and histomporphmetric evaluation of peri-implant bone subjected to immediate loading: an experimental study with Macaca fascicularis. Int J Oral Maxillofac Implants 2002; 17:44-51.
    • (2002) Int J Oral Maxillofac Implants , vol.17 , pp. 44-51
    • Romanos, G.E.1    Toh, C.G.2    Siar, C.H.3    Swaminathan, D.4
  • 6
    • 0031992325 scopus 로고    scopus 로고
    • Report of the American Academy of Periodontology's Workshop on the Design and Conduct of Clinical Trials for Endosseous Dental Implants
    • Cochran DL. Report of the American Academy of Periodontology's Workshop on the Design and Conduct of Clinical Trials for Endosseous Dental Implants. J Periodontol 1998; 69:280-284.
    • (1998) J Periodontol , vol.69 , pp. 280-284
    • Cochran, D.L.1
  • 7
    • 0142088696 scopus 로고    scopus 로고
    • Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface
    • Barewal R, Oates T, Meredith N, Cochran D. Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface. Int J Oral Maxillofac Implants 2003; 18:641-651.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 641-651
    • Barewal, R.1    Oates, T.2    Meredith, N.3    Cochran, D.4
  • 8
    • 0344010698 scopus 로고    scopus 로고
    • Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible
    • Beer A, Gahleitner A, Holm A, Tschabitscher M, Homolka P. Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible. Clin Oral Implants Res 2003; 14:616-620.
    • (2003) Clin Oral Implants Res , vol.14 , pp. 616-620
    • Beer, A.1    Gahleitner, A.2    Holm, A.3    Tschabitscher, M.4    Homolka, P.5
  • 10
    • 0032151752 scopus 로고    scopus 로고
    • Assessment of implant stability as a prognostic determinant
    • Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 1998; 11:491-501.
    • (1998) Int J Prosthodont , vol.11 , pp. 491-501
    • Meredith, N.1
  • 12
    • 0034574211 scopus 로고    scopus 로고
    • Measurements comparing the initial stability of five designs of dental implants: a human cadaver study
    • O'Sullivan D, Sennerby L, Meredith N. Measurements comparing the initial stability of five designs of dental implants: a human cadaver study. Clin Implant Dent Rela Res 2000; 2:85-92.
    • (2000) Clin Implant Dent Rela Res , vol.2 , pp. 85-92
    • O'Sullivan, D.1    Sennerby, L.2    Meredith, N.3
  • 13
    • 0032150708 scopus 로고    scopus 로고
    • Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature
    • Sennerby L, Roos J. Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature. Int J Prosthodont 1998; 11:408-420.
    • (1998) Int J Prosthodont , vol.11 , pp. 408-420
    • Sennerby, L.1    Roos, J.2
  • 14
    • 1342300783 scopus 로고    scopus 로고
    • Immediate loading of 190 endosseous dental implants: a prospective observational study of 40 patients treatments with up to 2-years data
    • Nikellis I, Levi A, Nicolopoulos C. Immediate loading of 190 endosseous dental implants: a prospective observational study of 40 patients treatments with up to 2-years data. Int J Oral Maxillofac Implants 2004; 19:116-123.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 116-123
    • Nikellis, I.1    Levi, A.2    Nicolopoulos, C.3
  • 15
    • 0034577023 scopus 로고    scopus 로고
    • Interaction of force-fitting and surface roughness of implants
    • Skalak R, Zhao Y. Interaction of force-fitting and surface roughness of implants. Clin Implant Dent Relat Res 2000; 2:219-224.
    • (2000) Clin Implant Dent Relat Res , vol.2 , pp. 219-224
    • Skalak, R.1    Zhao, Y.2
  • 16
    • 3042610261 scopus 로고    scopus 로고
    • Localized sinus elevation and osteocompression with single-stage tapered dental implants: technical note
    • Le Gall MG. Localized sinus elevation and osteocompression with single-stage tapered dental implants: technical note. Int J Oral Maxillofac Implants 2004; 19:431-437.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 431-437
    • Le Gall, M.G.1
  • 17
    • 0036974819 scopus 로고    scopus 로고
    • Histomorphometric and fluorescence microscopic analysis of bone remodeling after installation of implants using an osteotome technique
    • Nkenke E, Kloss F, Wiltfang J, etal. Histomorphometric and fluorescence microscopic analysis of bone remodeling after installation of implants using an osteotome technique. Clin Oral Implants Res 2002; 13:595-602.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 595-602
    • Nkenke, E.1    Kloss, F.2    Wiltfang, J.3
  • 19
    • 0026285722 scopus 로고
    • The relationship between insertion torque and removal torque analysed in fresh temporal bone
    • Ueda M, Matsuki M, Jacobsson M, Tjellström A. The relationship between insertion torque and removal torque analysed in fresh temporal bone. Int J Oral Maxillofac Implants 1991; 6:442-447.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 442-447
    • Ueda, M.1    Matsuki, M.2    Jacobsson, M.3    Tjellström, A.4
  • 20
    • 0141829269 scopus 로고    scopus 로고
    • One year prospective three center study comparing the outcome of a "soft bone implant" (prototype Mk IV) and the standard Brånemark implant
    • Friberg B, Jisander S, Widmark G, etal. One year prospective three center study comparing the outcome of a "soft bone implant" (prototype Mk IV) and the standard Brånemark implant. Clin Implant Dent Relat Res 2003; 5:71-77.
    • (2003) Clin Implant Dent Relat Res , vol.5 , pp. 71-77
    • Friberg, B.1    Jisander, S.2    Widmark, G.3
  • 21
    • 0035224741 scopus 로고    scopus 로고
    • Immediate provisional single-tooth implant replacement with Brånemark system: preliminary report
    • Hui E, Chow J, Li D, Liu J, Wat P, Law H. Immediate provisional single-tooth implant replacement with Brånemark system: preliminary report. Clin Implant Dent Relat Res 2001; 3:79-86.
    • (2001) Clin Implant Dent Relat Res , vol.3 , pp. 79-86
    • Hui, E.1    Chow, J.2    Li, D.3    Liu, J.4    Wat, P.5    Law, H.6
  • 22
    • 0000402785 scopus 로고
    • Assessment of bone quality from cutting resistance during implant surgery
    • Johansson P, Strid KG. Assessment of bone quality from cutting resistance during implant surgery. Int J Oral Maxillofac Implants 1994; 9:279-288.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 279-288
    • Johansson, P.1    Strid, K.G.2
  • 23
    • 0037822206 scopus 로고    scopus 로고
    • Immediate loading of single-tooth implants in the anterior maxilla. Preliminary results after one year
    • Lorenzoni M, Pertl C, Zhang K, Wimmer G, Wegscheider W. Immediate loading of single-tooth implants in the anterior maxilla. Preliminary results after one year. Clin Oral Implants Res 2003; 14:180-187.
    • (2003) Clin Oral Implants Res , vol.14 , pp. 180-187
    • Lorenzoni, M.1    Pertl, C.2    Zhang, K.3    Wimmer, G.4    Wegscheider, W.5
  • 24
    • 33846238497 scopus 로고    scopus 로고
    • Adapted preparation technique for screw-type implants: explorative in vitro pilot study in a porcine bone model
    • Beer A, Gahleitner A, Holm A, Birkfellner W, Homolka P. Adapted preparation technique for screw-type implants: explorative in vitro pilot study in a porcine bone model. Clin Oral Implants Res 2007; 18:103-107.
    • (2007) Clin Oral Implants Res , vol.18 , pp. 103-107
    • Beer, A.1    Gahleitner, A.2    Holm, A.3    Birkfellner, W.4    Homolka, P.5
  • 26
    • 33644693595 scopus 로고    scopus 로고
    • Human ex vivo bone tissue strains around immediately loaded implants supporting maxillary overdentures
    • Akça K, Akkocaoglu M, Comert A, Tekdemir I, Cehreli MC. Human ex vivo bone tissue strains around immediately loaded implants supporting maxillary overdentures. Clin Oral Implants Res 2005; 16:715-722.
    • (2005) Clin Oral Implants Res , vol.16 , pp. 715-722
    • Akça, K.1    Akkocaoglu, M.2    Comert, A.3    Tekdemir, I.4    Cehreli, M.C.5
  • 27
    • 34547700240 scopus 로고    scopus 로고
    • Clinical study on the primary stability of two dental implant systems with resonance frequency analysis
    • Rabel A, Köhler SG, Schmidt-Westhausen AM. Clinical study on the primary stability of two dental implant systems with resonance frequency analysis. Clin Oral Investig 2007; 11:257-265.
    • (2007) Clin Oral Investig , vol.11 , pp. 257-265
    • Rabel, A.1    Köhler, S.G.2    Schmidt-Westhausen, A.M.3
  • 28
    • 0033176199 scopus 로고    scopus 로고
    • A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20 months clinical study
    • Friberg B, Sennerby L, Meredith N, Lekholm U. A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20 months clinical study. Int J Oral Maxillofac Surg 1999; 28:297-303.
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 297-303
    • Friberg, B.1    Sennerby, L.2    Meredith, N.3    Lekholm, U.4
  • 29
    • 0034574209 scopus 로고    scopus 로고
    • Immediate function of Brånemark implants in the esthetic zone: a retrospective clinical study with 6 months to 4 years of follow-up
    • Malo P, Rangert B, Dvarsater L. Immediate function of Brånemark implants in the esthetic zone: a retrospective clinical study with 6 months to 4 years of follow-up. Clin Implant Dent Relat Res 2000; 2:138-146.
    • (2000) Clin Implant Dent Relat Res , vol.2 , pp. 138-146
    • Malo, P.1    Rangert, B.2    Dvarsater, L.3
  • 30
    • 0034326765 scopus 로고    scopus 로고
    • Immediate loading of Branemark system implants following placement in edentulous patients: a clinical report
    • Horiuchi K, Uchida H, Yamamoto K, Sugimura M. Immediate loading of Branemark system implants following placement in edentulous patients: a clinical report. Int J Oral Maxillofac Implants 2000; 15:824-830.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 824-830
    • Horiuchi, K.1    Uchida, H.2    Yamamoto, K.3    Sugimura, M.4
  • 32
    • 33646194028 scopus 로고    scopus 로고
    • Peri-implant bone organization under immediate loading state. Circularly polarized light analyses: a minipig study
    • Neugebauer J, Traini T, Thams U, Piatelli A, Zöller JE. Peri-implant bone organization under immediate loading state. Circularly polarized light analyses: a minipig study. J Periodontol 2006; 77:152-160.
    • (2006) J Periodontol , vol.77 , pp. 152-160
    • Neugebauer, J.1    Traini, T.2    Thams, U.3    Piatelli, A.4    Zöller, J.E.5
  • 34
    • 0029446141 scopus 로고
    • Implant stability related to insertion torque force and bone density: an in vitro study
    • Tricio J, Van Steenberghe D, Rosenberg D, Duchateau L. Implant stability related to insertion torque force and bone density: an in vitro study. J Prosthet Dent 1995; 74:608-612.
    • (1995) J Prosthet Dent , vol.74 , pp. 608-612
    • Tricio, J.1    Van Steenberghe, D.2    Rosenberg, D.3    Duchateau, L.4
  • 35
    • 33947322536 scopus 로고    scopus 로고
    • A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment
    • Alsaadi G, Quirynen M, Michiels K, Jacobs R, Van Steenberghe D. A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment. J Clin Periodontol 2007; 34:359-366.
    • (2007) J Clin Periodontol , vol.34 , pp. 359-366
    • Alsaadi, G.1    Quirynen, M.2    Michiels, K.3    Jacobs, R.4    Van Steenberghe, D.5
  • 36
    • 34547174147 scopus 로고    scopus 로고
    • Relations between the bone density values from computerized tomography, and implant stability parameters: a clinical study of 230 regular platform implants
    • Turkyilmaz I, Tumer C, Ozbek EN, Tözüm TF. Relations between the bone density values from computerized tomography, and implant stability parameters: a clinical study of 230 regular platform implants. J Clin Periodontol 2007; 34:716-722.
    • (2007) J Clin Periodontol , vol.34 , pp. 716-722
    • Turkyilmaz, I.1    Tumer, C.2    Ozbek, E.N.3    Tözüm, T.F.4
  • 37
    • 0002172340 scopus 로고
    • Patient selection and preparation
    • Brånemark PI, Zarb GA, Albrektsson T, eds. . Chicago, IL: Quintessence Publishing Co. Inc.
    • Lekholm U, Zarb GA. Patient selection and preparation. In: Brånemark PI, Zarb GA, Albrektsson T, eds. Tissue integrated prostheses: osseointegration in clinical dentistry. Chicago, IL: Quintessence Publishing Co. Inc., 1985:199-209.
    • (1985) Tissue integrated prostheses: osseointegration in clinical dentistry , pp. 199-209
    • Lekholm, U.1    Zarb, G.A.2
  • 39
    • 0031197165 scopus 로고    scopus 로고
    • A comparative study of removal torque of endosseous implants in the fibula, iliac crest and scapula of cadavers: preliminary report
    • Niimi A, Ozeki K, Ueda M, Nakayama B. A comparative study of removal torque of endosseous implants in the fibula, iliac crest and scapula of cadavers: preliminary report. Clin Oral Implants Res 1997; 8:286-289.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 286-289
    • Niimi, A.1    Ozeki, K.2    Ueda, M.3    Nakayama, B.4
  • 40
    • 0038176376 scopus 로고    scopus 로고
    • Early functional loading at 5 days for Branemark implants placed into edentulous mandibles: a prospective, open-ended, longitudinal study
    • Becker W, Becker BE, Huffstetler S. Early functional loading at 5 days for Branemark implants placed into edentulous mandibles: a prospective, open-ended, longitudinal study. J Periodontol 2003; 74:695-702.
    • (2003) J Periodontol , vol.74 , pp. 695-702
    • Becker, W.1    Becker, B.E.2    Huffstetler, S.3
  • 41
    • 0019663098 scopus 로고
    • A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
    • Adell R, Lekholm U, Rockler B, Brånemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981; 10:387-416.
    • (1981) Int J Oral Surg , vol.10 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3    Brånemark, P.I.4
  • 42
    • 0022726532 scopus 로고
    • The long-term efficacy of currently used dental implants: a review and proposed criteria of success
    • Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants 1986; 1:11-25.
    • (1986) Int J Oral Maxillofac Implants , vol.1 , pp. 11-25
    • Albrektsson, T.1    Zarb, G.2    Worthington, P.3    Eriksson, A.R.4
  • 43
    • 0024760224 scopus 로고
    • Criteria for success of osseointegrated endosseous implants
    • Smith DE, Zarb GA. Criteria for success of osseointegrated endosseous implants. J Prosthet Dent 1989; 62:567-572.
    • (1989) J Prosthet Dent , vol.62 , pp. 567-572
    • Smith, D.E.1    Zarb, G.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.