메뉴 건너뛰기




Volumn 16, Issue 6, 2005, Pages 715-722

Human ex vivo bone tissue strains around immediately loaded implants supporting maxillary overdentures

Author keywords

Biomechanics; Bone strain; Immediate loading; Installation torque; Maxilla; Overdenture; Removal torque; Resonance frequency analysis

Indexed keywords

AGED; ARTICLE; CADAVER; DENTAL CARE; DENTURE; FEMALE; HUMAN; INSTRUMENTATION; MALE; MASTICATION; MAXILLA; MECHANICAL STRESS; MIDDLE AGED; NONPARAMETRIC TEST; PHYSIOLOGY; STATISTICS; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TORQUE; VIBRATION;

EID: 33644693595     PISSN: 09057161     EISSN: 16000501     Source Type: Journal    
DOI: 10.1111/j.1600-0501.2005.01176.x     Document Type: Article
Times cited : (22)

References (42)
  • 1
    • 18744396684 scopus 로고    scopus 로고
    • Implant design and intraosseous stability of immediately-placed implants: A human cadaver study
    • Akkocaoglu, M., Uysal, S., Tekdemir, I., Akca, K. Cehreli, M.C. (2005) Implant design and intraosseous stability of immediately-placed implants: a human cadaver study. Clinical Oral Implants Research 16 : 202 209.
    • (2005) Clinical Oral Implants Research , vol.16 , pp. 202-209
    • Akkocaoglu, M.1    Uysal, S.2    Tekdemir, I.3    Akca, K.4    Cehreli, M.C.5
  • 2
    • 0034045848 scopus 로고    scopus 로고
    • A strain gauge and photoelastic analysis of in vivo strain and in vitro stress distribution in human dental supporting structures
    • Asundi, A. Kishen, A. (2000) A strain gauge and photoelastic analysis of in vivo strain and in vitro stress distribution in human dental supporting structures. Archives of Oral Biology 45 : 543 550.
    • (2000) Archives of Oral Biology , vol.45 , pp. 543-550
    • Asundi, A.1    Kishen, A.2
  • 6
    • 0023522742 scopus 로고
    • Mechanical history and skeletal biology
    • Carter, D.R. (1987) Mechanical history and skeletal biology. Journal of Biomechanics 20 : 1095 1109.
    • (1987) Journal of Biomechanics , vol.20 , pp. 1095-1109
    • Carter, D.R.1
  • 8
    • 0023198738 scopus 로고
    • Influences of mechanical stress on prenatal and postnatal skeletal development
    • Carter, D.R., Orr, T.E., Fyhrie, D.P. Schurman, D.J. (1987) Influences of mechanical stress on prenatal and postnatal skeletal development. Clinical Orthopaedics 238 : 237 250.
    • (1987) Clinical Orthopaedics , vol.238 , pp. 237-250
    • Carter, D.R.1    Orr, T.E.2    Fyhrie, D.P.3    Schurman, D.J.4
  • 9
    • 4644304411 scopus 로고    scopus 로고
    • Dynamic fatigue resistance of implant-abutment junction in an internally-notched morse-taper oral implant: Influence of abutment design
    • Cehreli, M.C., Akca, K., Iplikcioglu, H. Sahin, S. (2004) Dynamic fatigue resistance of implant-abutment junction in an internally-notched morse-taper oral implant: influence of abutment design. Clinical Oral Implants Research 15 : 459 465.
    • (2004) Clinical Oral Implants Research , vol.15 , pp. 459-465
    • Cehreli, M.C.1    Akca, K.2    Iplikcioglu, H.3    Sahin, S.4
  • 11
    • 0036550748 scopus 로고    scopus 로고
    • The influence of the location of load transfer on strains around implants supporting four unit cement retained prosthesis
    • Cehreli, M.C., Iplikcioglu, H. Bilir, O.G. (2002) The influence of the location of load transfer on strains around implants supporting four unit cement retained prosthesis. Journal of Oral Rehabilitation 29 : 394 400.
    • (2002) Journal of Oral Rehabilitation , vol.29 , pp. 394-400
    • Cehreli, M.C.1    Iplikcioglu, H.2    Bilir, O.G.3
  • 13
    • 0038519767 scopus 로고    scopus 로고
    • Retention mechanisms and prosthetic complications of implant-supported mandibular overdentures: Long-term results
    • Dudic, A. Merickse-Stern, R. (2002) Retention mechanisms and prosthetic complications of implant-supported mandibular overdentures: long-term results. Clinical Implant Dentistry & Related Research 4 : 212 219.
    • (2002) Clinical Implant Dentistry & Related Research , vol.4 , pp. 212-219
    • Dudic, A.1    Merickse-Stern, R.2
  • 14
    • 0025269893 scopus 로고
    • Skeletal structural adaptations to mechanical usage (SATMU): 1. Redefining Wolff-s law: The bone modelling problem
    • Frost, H.M. (1990) Skeletal structural adaptations to mechanical usage (SATMU): 1. Redefining Wolff-s law: the bone modelling problem. Anatomical Record 226 : 403 413.
    • (1990) Anatomical Record , vol.226 , pp. 403-413
    • Frost, H.M.1
  • 15
    • 0028253303 scopus 로고
    • Wolff's law and bone's structural adaptations to mechanical usage: An overview for clinicians
    • Frost, H.M. (1994) Wolff's law and bone's structural adaptations to mechanical usage: an overview for clinicians. Angle Orthodontics 64 : 175 188.
    • (1994) Angle Orthodontics , vol.64 , pp. 175-188
    • Frost, H.M.1
  • 16
    • 0141709289 scopus 로고    scopus 로고
    • Biomechanical aspects on overdenture treatment
    • Glantz, P.-O. Nilner, K. (1997) Biomechanical aspects on overdenture treatment. Journal of Dentistry 25 : 21 24.
    • (1997) Journal of Dentistry , vol.25 , pp. 21-24
    • Glantz, P.-O.1    Nilner, K.2
  • 17
    • 0042513564 scopus 로고    scopus 로고
    • Immediate occlusal loading of Branemark Tiunite implants placed predominantly in soft bone: 1-year results of a prospective clinical study
    • Glauser, R., Ruhstaller, P. Hammerle, C.H. (2003) Immediate occlusal loading of Branemark Tiunite implants placed predominantly in soft bone: 1-year results of a prospective clinical study. Clinical Implant Dentistry & Related Research 5 : 47 55.
    • (2003) Clinical Implant Dentistry & Related Research , vol.5 , pp. 47-55
    • Glauser, R.1    Ruhstaller, P.2    Hammerle, C.H.3
  • 19
    • 0036134211 scopus 로고    scopus 로고
    • Comparative evaluation of the effect of diameter, length and number of implants supporting three occlusal unit fixed partial prostheses on stress distribution in bone
    • Iplikcioglu, H. Akca, K. (2002) Comparative evaluation of the effect of diameter, length and number of implants supporting three occlusal unit fixed partial prostheses on stress distribution in bone. Journal of Dentistry 30 : 41 46.
    • (2002) Journal of Dentistry , vol.30 , pp. 41-46
    • Iplikcioglu, H.1    Akca, K.2
  • 22
    • 0018589158 scopus 로고
    • Stegprothetische Versorgung des zahnlosen Unterkiefers mit Hilfe plasmabeschichteten Titanschraubimplantaten
    • Ledermann, P.D. (1979) Stegprothetische Versorgung des zahnlosen Unterkiefers mit Hilfe plasmabeschichteten Titanschraubimplantaten. Deutsche Zahnärtzlische Zeitung 34 : 907 911.
    • (1979) Deutsche Zahnärtzlische Zeitung , vol.34 , pp. 907-911
    • Ledermann, P.D.1
  • 23
    • 0042961795 scopus 로고
    • Das TPS-Schraubeimplantat nach siebenjähriger Anwendung
    • Ledermann, P.D. (1984) Das TPS-Schraubeimplantat nach siebenjähriger Anwendung. Quintessenz 30 : 1 11.
    • (1984) Quintessenz , vol.30 , pp. 1-11
    • Ledermann, P.D.1
  • 24
    • 0025582810 scopus 로고
    • Immediate loading of cylinder implants with overdentures in the mandibular symphysis: The titanium plasma-sprayed screw technique
    • Lefkove, M.D. Beals, R.P. (1990) Immediate loading of cylinder implants with overdentures in the mandibular symphysis: the titanium plasma-sprayed screw technique. Journal of Oral Implantology 16 : 265 271.
    • (1990) Journal of Oral Implantology , vol.16 , pp. 265-271
    • Lefkove, M.D.1    Beals, R.P.2
  • 25
    • 0034141403 scopus 로고    scopus 로고
    • Bone surface strains and internal bony pressures at the jaw joint of the miniature pig during masticatory muscle contraction
    • Liu, Z.J. Herring, S.W. (2000) Bone surface strains and internal bony pressures at the jaw joint of the miniature pig during masticatory muscle contraction. Archives of Oral Biology 45 : 95 112.
    • (2000) Archives of Oral Biology , vol.45 , pp. 95-112
    • Liu, Z.J.1    Herring, S.W.2
  • 26
    • 0037822206 scopus 로고    scopus 로고
    • Immediate loading of single-tooth implants in the anterior maxilla. Preliminary results after one year
    • Lorenzoni, M., Pertl, C., Zhang, K., Wimmer, G. Wegscheider, W.A. (2003) Immediate loading of single-tooth implants in the anterior maxilla. Preliminary results after one year. Clinical Oral Implants Research 14 : 180 187.
    • (2003) Clinical Oral Implants Research , vol.14 , pp. 180-187
    • Lorenzoni, M.1    Pertl, C.2    Zhang, K.3    Wimmer, G.4    Wegscheider, W.A.5
  • 27
    • 0032151752 scopus 로고    scopus 로고
    • Assessment of implant stability as a prognostic determinant
    • Meredith, N. (1998) Assessment of implant stability as a prognostic determinant. International Journal of Prosthodontics 11 : 491 501.
    • (1998) International Journal of Prosthodontics , vol.11 , pp. 491-501
    • Meredith, N.1
  • 28
    • 0031107925 scopus 로고    scopus 로고
    • Force distribution on implants supporting overdentures: The effect of distal bar extensions. a 3-D in vivo study
    • Merickse-Stern, R. (1997) Force distribution on implants supporting overdentures: the effect of distal bar extensions. A 3-D in vivo study. Clinical Oral Implants Research 8 : 142 151.
    • (1997) Clinical Oral Implants Research , vol.8 , pp. 142-151
    • Merickse-Stern, R.1
  • 29
    • 0030320450 scopus 로고    scopus 로고
    • 3-D in vivo force measurements on mandibular implants supporting overdentures. a comparative study
    • Merickse-Stern, R., Piotti, M. Sirtes, G. (1996) 3-D in vivo force measurements on mandibular implants supporting overdentures. A comparative study. Clinical Oral Implants Research 7 : 387 396.
    • (1996) Clinical Oral Implants Research , vol.7 , pp. 387-396
    • Merickse-Stern, R.1    Piotti, M.2    Sirtes, G.3
  • 31
    • 0033087984 scopus 로고    scopus 로고
    • A 5-year prospective randomized clinical trial on the influence of splinted and unsplinted oral implants retaining a mandibular overdenture: Prosthetic aspects and patient satisfaction
    • Naert, I., Gizani, S., Vuylsteke, M. Van Steenberghe, D. (1999) A 5-year prospective randomized clinical trial on the influence of splinted and unsplinted oral implants retaining a mandibular overdenture: prosthetic aspects and patient satisfaction. Journal of Oral Rehabilitation 26 : 195 202.
    • (1999) Journal of Oral Rehabilitation , vol.26 , pp. 195-202
    • Naert, I.1    Gizani, S.2    Vuylsteke, M.3    Van Steenberghe, D.4
  • 32
    • 2442492090 scopus 로고    scopus 로고
    • Photoelastic analysis of the effect of palatal support on various implant-supported overdenture designs
    • Ochiai, K.T., Williams, B.H., Hojo, S., Nishimura, R. Caputo, A.A. (2004) Photoelastic analysis of the effect of palatal support on various implant-supported overdenture designs. Journal of Prosthetic Dentistry 91 : 421 427.
    • (2004) Journal of Prosthetic Dentistry , vol.91 , pp. 421-427
    • Ochiai, K.T.1    Williams, B.H.2    Hojo, S.3    Nishimura, R.4    Caputo, A.A.5
  • 33
    • 0035235832 scopus 로고    scopus 로고
    • One-year prospective evaluation of the early loading of unsplinted conical Branemark fixtures with mandibular overdentures immediately following surgery
    • Payne, A.G., Tawse-Smith, A., Kumara, R. Thomson, W.M. (2001) One-year prospective evaluation of the early loading of unsplinted conical Branemark fixtures with mandibular overdentures immediately following surgery. Clinical Implant Dentistry & Related Research 3 : 9 19.
    • (2001) Clinical Implant Dentistry & Related Research , vol.3 , pp. 9-19
    • Payne, A.G.1    Tawse-Smith, A.2    Kumara, R.3    Thomson, W.M.4
  • 34
    • 0022465758 scopus 로고
    • Observation of the effect of movement on the bone ingrowth into porous surfaced implants
    • Pilliar, R.M., Lee, J.M. Maniatopoulos, C. (1986) Observation of the effect of movement on the bone ingrowth into porous surfaced implants. Clinical Orthopaedics 208 : 108 113.
    • (1986) Clinical Orthopaedics , vol.208 , pp. 108-113
    • Pilliar, R.M.1    Lee, J.M.2    Maniatopoulos, C.3
  • 38
    • 0025618219 scopus 로고
    • Immediate fixed interim prostheses supported by two-stage threaded implants: Methodology and results
    • Schnitman, P.A., Wohrle, P.S. Rubenstein, J.E. (1990) Immediate fixed interim prostheses supported by two-stage threaded implants: methodology and results. Journal of Oral Implantology 16 : 96 105.
    • (1990) Journal of Oral Implantology , vol.16 , pp. 96-105
    • Schnitman, P.A.1    Wohrle, P.S.2    Rubenstein, J.E.3
  • 40
    • 0036365690 scopus 로고    scopus 로고
    • Early loading of unsplinted implants supporting mandibular overdentures using a one-stage operative procedure with two different implant systems: A 2-year report
    • Tawse-Smith, A., Payne, A.G., Kumara, R. Thomson, W.M. (2002) Early loading of unsplinted implants supporting mandibular overdentures using a one-stage operative procedure with two different implant systems: a 2-year report. Clinical Implant Dentistry & Related Research 4 : 33 42.
    • (2002) Clinical Implant Dentistry & Related Research , vol.4 , pp. 33-42
    • Tawse-Smith, A.1    Payne, A.G.2    Kumara, R.3    Thomson, W.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.