메뉴 건너뛰기




Volumn 82, Issue 5, 2013, Pages

Body mass index-adapted prospective coronary computed tomography angiography. Determining the lowest limit for diagnostic purposes

Author keywords

256 Slice computed tomography angiography; Image quality; Prospective ECG triggering; Radiation exposure; Ultra low dose coronary CTA

Indexed keywords

ADULT; ANGIOCARDIOGRAPHY; ARTICLE; BODY MASS; CONTRAST TO NOISE RATIO; CONTROLLED STUDY; CORONARY ARTERY DISEASE; DIAGNOSTIC IMAGING; FEMALE; HUMAN; IMAGE QUALITY; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; PROSPECTIVE STUDY; RADIATION DOSE; RADIATION EXPOSURE; SIGNAL NOISE RATIO;

EID: 84875712293     PISSN: 0720048X     EISSN: 18727727     Source Type: Journal    
DOI: 10.1016/j.ejrad.2012.12.013     Document Type: Article
Times cited : (9)

References (23)
  • 1
    • 84928097222 scopus 로고    scopus 로고
    • A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group
    • ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging
    • ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging. A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group. Journal of the American College of Radiology 2006; 3:751-71.
    • (2006) Journal of the American College of Radiology , vol.3 , pp. 751-771
  • 2
    • 77953498744 scopus 로고    scopus 로고
    • The diagnostic accuracy of 256-row computed tomographic angiography compared with invasive coronary angiography in patients with suspected coronary artery disease
    • S.P. Chao, W.Y. Law, C.J. Kuo, H.F. Hung, J.J. Cheng, and H.M. Lo The diagnostic accuracy of 256-row computed tomographic angiography compared with invasive coronary angiography in patients with suspected coronary artery disease European Heart Journal 31 2010 1916 1923
    • (2010) European Heart Journal , vol.31 , pp. 1916-1923
    • Chao, S.P.1    Law, W.Y.2    Kuo, C.J.3    Hung, H.F.4    Cheng, J.J.5    Lo, H.M.6
  • 3
    • 77957943350 scopus 로고    scopus 로고
    • Quantitative assessment of stenosis severity and atherosclerotic plaque composition using 256-slice computed tomography
    • G. Korosoglou, D. Mueller, S. Lehrke, H. Steen, W. Hosch, and T. Heye Quantitative assessment of stenosis severity and atherosclerotic plaque composition using 256-slice computed tomography European Radiology 20 2010 1841 1850
    • (2010) European Radiology , vol.20 , pp. 1841-1850
    • Korosoglou, G.1    Mueller, D.2    Lehrke, S.3    Steen, H.4    Hosch, W.5    Heye, T.6
  • 4
    • 34447558140 scopus 로고    scopus 로고
    • Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography
    • DOI 10.1001/jama.298.3.317
    • A.J. Einstein, M.J. Henzlova, and S. Rajagopalan Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography The Journal of American Medical Association 298 2007 317 323 (Pubitemid 47080486)
    • (2007) Journal of the American Medical Association , vol.298 , Issue.3 , pp. 317-323
    • Einstein, A.J.1    Henzlova, M.J.2    Rajagopalan, S.3
  • 5
    • 84867022029 scopus 로고    scopus 로고
    • Reduction of radiation exposure and improvement of image quality with BMI-adapted prospective cardiac computed tomography and iterative reconstruction
    • W. Hosch, W. Stiller, D. Mueller, G. Gitsioudis, J. Welzel, and M. Dadrich Reduction of radiation exposure and improvement of image quality with BMI-adapted prospective cardiac computed tomography and iterative reconstruction European Journal of Radiology 81 2012 3568 3576
    • (2012) European Journal of Radiology , vol.81 , pp. 3568-3576
    • Hosch, W.1    Stiller, W.2    Mueller, D.3    Gitsioudis, G.4    Welzel, J.5    Dadrich, M.6
  • 6
    • 78249261294 scopus 로고    scopus 로고
    • Image quality and radiation exposure with a low tube voltage protocol for coronary ct angiography results of the protection ii trial
    • J. Hausleiter, S. Martinoff, M. Hadamitzky, E. Martuscelli, I. Pschierer, and G.M. Feuchtner Image quality and radiation exposure with a low tube voltage protocol for coronary ct angiography results of the protection ii trial JACC Cardiovascular imaging 3 2010 1113 1123
    • (2010) JACC Cardiovascular Imaging , vol.3 , pp. 1113-1123
    • Hausleiter, J.1    Martinoff, S.2    Hadamitzky, M.3    Martuscelli, E.4    Pschierer, I.5    Feuchtner, G.M.6
  • 7
    • 84861150020 scopus 로고    scopus 로고
    • Image quality and radiation exposure with prospectively ECG-triggered axial scanning for coronary CT angiography: The multicenter, multivendor, randomized PROTECTION-III study
    • J. Hausleiter, T.S. Meyer, E. Martuscelli, P. Spagnolo, H. Yamamoto, and P. Carrascosa Image quality and radiation exposure with prospectively ECG-triggered axial scanning for coronary CT angiography: the multicenter, multivendor, randomized PROTECTION-III study JACC Cardiovascular Imaging 5 2012 484 493
    • (2012) JACC Cardiovascular Imaging , vol.5 , pp. 484-493
    • Hausleiter, J.1    Meyer, T.S.2    Martuscelli, E.3    Spagnolo, P.4    Yamamoto, H.5    Carrascosa, P.6
  • 8
    • 80052762886 scopus 로고    scopus 로고
    • Image quality and radiation dose in 256-slice cardiac computed tomography: Comparison of prospective versus retrospective image acquisition protocols
    • W. Hosch, T. Heye, F. Schulz, S. Lehrke, M. Schlieter, and E. Giannitsis Image quality and radiation dose in 256-slice cardiac computed tomography: comparison of prospective versus retrospective image acquisition protocols European Journal of Radiology 80 2011 127 135
    • (2011) European Journal of Radiology , vol.80 , pp. 127-135
    • Hosch, W.1    Heye, T.2    Schulz, F.3    Lehrke, S.4    Schlieter, M.5    Giannitsis, E.6
  • 9
    • 79954562252 scopus 로고    scopus 로고
    • Detection of coronary artery stenoses by low-dose, prospectively ECG-triggered, high-pitch spiral coronary CT angiography
    • S. Achenbach, T. Goroll, M. Seltmann, T. Pflederer, K. Anders, and D. Ropers Detection of coronary artery stenoses by low-dose, prospectively ECG-triggered, high-pitch spiral coronary CT angiography JACC Cardiovascular Imaging 4 2011 328 337
    • (2011) JACC Cardiovascular Imaging , vol.4 , pp. 328-337
    • Achenbach, S.1    Goroll, T.2    Seltmann, M.3    Pflederer, T.4    Anders, K.5    Ropers, D.6
  • 10
  • 11
    • 15944402152 scopus 로고    scopus 로고
    • Improvement of image quality with β-blocker premedication on ECG-gated 16-MDCT coronary angiography
    • S.S. Shim, Y. Kim, and S.M. Lim Improvement of image quality with beta-blocker premedication on ECG-gated 16-MDCT coronary angiography AJR American Journal of Roentgenology 184 2005 649 654 (Pubitemid 46657279)
    • (2005) American Journal of Roentgenology , vol.184 , Issue.2 , pp. 649-654
    • Shim, S.S.1    Kim, Y.2    Lim, S.M.3
  • 13
    • 61849088894 scopus 로고    scopus 로고
    • Ionizing radiation in cardiac imaging: A science advisory from the American Heart Association Committee on cardiac imaging of the council on clinical cardiology and committee on cardiovascular imaging and intervention of the council on cardiovascular radiology and intervention
    • T.C. Gerber, J.J. Carr, A.E. Arai, R.L. Dixon, V.A. Ferrari, and A.S. Gomes Ionizing radiation in cardiac imaging: a science advisory from the American Heart Association Committee on cardiac imaging of the council on clinical cardiology and committee on cardiovascular imaging and intervention of the council on cardiovascular radiology and intervention Circulation 119 2009 1056 1065
    • (2009) Circulation , vol.119 , pp. 1056-1065
    • Gerber, T.C.1    Carr, J.J.2    Arai, A.E.3    Dixon, R.L.4    Ferrari, V.A.5    Gomes, A.S.6
  • 14
    • 40949118140 scopus 로고    scopus 로고
    • Reduction of radiation dose estimates in cardiac 64-slice CT angiography in patients after coronary artery bypass graft surgery
    • DOI 10.1097/RLI.0b013e318160b3a3, PII 0000442420080400000006
    • F. Hermann, S. Martinoff, T. Meyer, M. Hadamitzky, C. Jiang, and E. Hendrich Reduction of radiation dose estimates in cardiac 64-slice CT angiography in patients after coronary artery bypass graft surgery Investigative Radiology 43 2008 253 260 (Pubitemid 351416768)
    • (2008) Investigative Radiology , vol.43 , Issue.4 , pp. 253-260
    • Hermann, F.1    Martinoff, S.2    Meyer, T.3    Hadamitzky, M.4    Jiang, C.5    Hendrich, E.6    Hausleiter, J.7
  • 16
    • 40949165279 scopus 로고    scopus 로고
    • Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose
    • J.P. Earls, E.L. Berman, B.A. Urban, C.A. Curry, J.L. Lane, and R.S. Jennings Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose Radiology 246 2008 742 753
    • (2008) Radiology , vol.246 , pp. 742-753
    • Earls, J.P.1    Berman, E.L.2    Urban, B.A.3    Curry, C.A.4    Lane, J.L.5    Jennings, R.S.6
  • 17
    • 38349134611 scopus 로고    scopus 로고
    • Feasibility of low-dose coronary CT angiography: First experience with prospective ECG-gating
    • L. Husmann, I. Valenta, O. Gaemperli, O. Adda, V. Treyer, and C.A. Wyss Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating European Heart Journal 29 2008 191 197
    • (2008) European Heart Journal , vol.29 , pp. 191-197
    • Husmann, L.1    Valenta, I.2    Gaemperli, O.3    Adda, O.4    Treyer, V.5    Wyss, C.A.6
  • 19
    • 33846251912 scopus 로고    scopus 로고
    • Low tube voltage improves computed tomography imaging of delayed myocardial contrast enhancement in an experimental acute myocardial infarction model
    • DOI 10.1097/01.rli.0000251577.68223.84, PII 0000442420070200000008
    • A.H. Mahnken, P. Bruners, G. Muhlenbruch, M. Emmerich, C. Hohl, and R.W. Gunther Low tube voltage improves computed tomography imaging of delayed myocardial contrast enhancement in an experimental acute myocardial infarction model Investigative Radiology 42 2007 123 129 (Pubitemid 46104893)
    • (2007) Investigative Radiology , vol.42 , Issue.2 , pp. 123-129
    • Mahnken, A.H.1    Bruners, P.2    Muhlenbruch, G.3    Emmerich, M.4    Hohl, C.5    Gunther, R.W.6    Wildberger, J.E.7
  • 20
    • 41149124559 scopus 로고    scopus 로고
    • Noninvasive coronary angiography using 64-slice spiral computed tomography in an unselected patient collective: Effect of heart rate, heart rate variability and coronary calcifications on image quality and diagnostic accuracy
    • DOI 10.1016/j.ejrad.2007.05.013, PII S0720048X07002550
    • H. Brodoefel, A. Reimann, C. Burgstahler, F. Schumacher, T. Herberts, and I. Tsiflikas Noninvasive coronary angiography using 64-slice spiral computed tomography in an unselected patient collective: effect of heart rate, heart rate variability and coronary calcifications on image quality and diagnostic accuracy European Journal of Radiology 66 2008 134 141 (Pubitemid 351434522)
    • (2008) European Journal of Radiology , vol.66 , Issue.1 , pp. 134-141
    • Brodoefel, H.1    Reimann, A.2    Burgstahler, C.3    Schumacher, F.4    Herberts, T.5    Tsiflikas, I.6    Schroeder, S.7    Claussen, C.D.8    Kopp, A.F.9    Heuschmid, M.10
  • 21
    • 84860319410 scopus 로고    scopus 로고
    • A hybrid iterative reconstruction algorithm that improves the image quality of low-tube-voltage coronary CT angiography
    • S. Oda, D. Utsunomiya, Y. Funama, K. Yonenaga, T. Namimoto, and T. Nakaura A hybrid iterative reconstruction algorithm that improves the image quality of low-tube-voltage coronary CT angiography AJR American Journal of Roentgenology 198 2012 1126 1131
    • (2012) AJR American Journal of Roentgenology , vol.198 , pp. 1126-1131
    • Oda, S.1    Utsunomiya, D.2    Funama, Y.3    Yonenaga, K.4    Namimoto, T.5    Nakaura, T.6
  • 23
    • 84874507632 scopus 로고    scopus 로고
    • 64-slice coronary computed tomography angiography using low tube voltage of 80 kV in subjects with normal body mass indices: Comparative study using 120 kV
    • B.R. Jun, H.S. Yong, E.Y. Kang, O.H. Woo, and E.J. Choi 64-slice coronary computed tomography angiography using low tube voltage of 80 kV in subjects with normal body mass indices: comparative study using 120 kV Acta Radiologica 2012
    • (2012) Acta Radiologica
    • Jun, B.R.1    Yong, H.S.2    Kang, E.Y.3    Woo, O.H.4    Choi, E.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.