메뉴 건너뛰기




Volumn 42, Issue 2, 2013, Pages

Accuracy of vertical height measurements on direct digital panoramic radiographs using posterior mandibular implants and metal balls as reference objects

Author keywords

Dental implant; Digital dental radiography; Panoramic radiography; Radiographic magnification

Indexed keywords

ALLOY; CONTRAST MEDIUM;

EID: 84875171895     PISSN: 0250832X     EISSN: None     Source Type: Journal    
DOI: 10.1259/dmfr.20110429     Document Type: Article
Times cited : (36)

References (35)
  • 2
    • 18544400674 scopus 로고    scopus 로고
    • EAO Guidelines for the use of diagnostic imaging in implant dentistry A consensus workshop organized by the european association for osseointegration in trinity college dublin
    • Harris D, Buser D, Dula K, Grondahl K, Haris D, Jacobs R, et al. EAO Guidelines for the use of diagnostic imaging in implant dentistry. A consensus workshop organized by the European Association for Osseointegration in Trinity College Dublin. Clin Oral Implants Res 2002; 13: 566-570.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 566-570
    • Harris, D.1    Buser, D.2    Dula, K.3    Grondahl, K.4    Haris, D.5    Jacobs, R.6
  • 3
    • 4644259597 scopus 로고    scopus 로고
    • Study on the necessity for cross-section imaging of the posterior mandible for treatment planning of standard cases in implant dentistry
    • Frei C, Buser D, Dula K. Study on the necessity for cross-section imaging of the posterior mandible for treatment planning of standard cases in implant dentistry. Clin Oral Implants Res 2004; 15: 490-497.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 490-497
    • Frei, C.1    Buser, D.2    Dula, K.3
  • 4
    • 37249040000 scopus 로고    scopus 로고
    • Efficacy of panoramic radiographs in the preoperative planning of posterior mandibular implants: A prospective clinical study of 1527 consecutively treated patients
    • Vazquez L, Saulacic N, Belser U, Bernard JP. Efficacy of panoramic radiographs in the preoperative planning of posterior mandibular implants: a prospective clinical study of 1527 consecutively treated patients. Clin Oral Implants Res 2008; 19: 81-85.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 81-85
    • Vazquez, L.1    Saulacic, N.2    Belser, U.3    Bernard, J.P.4
  • 5
    • 80755135441 scopus 로고    scopus 로고
    • Reliability of the vertical magnification factor on panoramic radiographs: Clinical implications for posterior mandibular implants
    • Vazquez L, Nizam Al Din Y, Belser UC, Combescure C, Bernard JP. Reliability of the vertical magnification factor on panoramic radiographs: clinical implications for posterior mandibular implants. Clin Oral Impl Res 2011; 22: 1420-1425.
    • (2011) Clin Oral Impl Res , vol.22 , pp. 1420-1425
    • Vazquez, L.1    Nizam Al Din, Y.2    Belser, U.C.3    Combescure, C.4    Bernard, J.P.5
  • 6
    • 0026112449 scopus 로고
    • A comparison of panoramic radiography with computed tomography in the planning of implant surgery
    • Tal H, Moses O. A comparison of panoramic radiography with computed tomography in the planning of implant surgery. Dentomaxillofac Radiol 1991; 20: 40-42.
    • (1991) Dentomaxillofac Radiol , vol.20 , pp. 40-42
    • Tal, H.1    Moses, O.2
  • 7
    • 0019848361 scopus 로고
    • Image distortion in rotational panoramic radiography I. General considerations
    • Tronje G, Welander U, McDavid WD, Morris CR. Image distortion in rotational panoramic radiography. I. General considerations. Acta Radiol Diagn (Stockh) 1981; 22: 295-299.
    • (1981) Acta Radiol Diagn (Stockh) , vol.22 , pp. 295-299
    • Tronje, G.1    Welander, U.2    McDavid, W.D.3    Morris, C.R.4
  • 8
    • 0019837709 scopus 로고
    • Image distortion in rotational panoramic radiography. II. Vertical distances
    • Tronje G, Eliasson S, Julin P, Welander U. Image distortion in rotational panoramic radiography. II. Vertical distances. Acta Radiol Diagn (Stockh) 1981; 22: 449-455.
    • (1981) Acta Radiol Diagn (Stockh) , vol.22 , pp. 449-455
    • Tronje, G.1    Eliasson, S.2    Julin, P.3    Welander, U.4
  • 12
    • 0033090826 scopus 로고    scopus 로고
    • Areadependent enlargement ratios of panoramic tomography on orthograde patient positioning and its significance for implant dentistry
    • Gomez-Roman G, Lukas D, Beniashvili R, Schulte W. Areadependent enlargement ratios of panoramic tomography on orthograde patient positioning and its significance for implant dentistry. Int J Oral Maxillofac Implants 1999; 14: 248-257.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 248-257
    • Gomez-Roman, G.1    Lukas, D.2    Beniashvili, R.3    Schulte, W.4
  • 13
    • 0036484114 scopus 로고    scopus 로고
    • Accuracy of linear and angular measurements on panoramic radiographs taken at various positions in vitro
    • Stramotas S, Geenty JP, Petocz P, Darendeliler MA. Accuracy of linear and angular measurements on panoramic radiographs taken at various positions in vitro. Eur J Orthod 2002; 24: 43-52.
    • (2002) Eur J Orthod , vol.24 , pp. 43-52
    • Stramotas, S.1    Geenty, J.P.2    Petocz, P.3    Darendeliler, M.A.4
  • 14
    • 71149096293 scopus 로고    scopus 로고
    • Calibration of radiographs by a reference metal ball affects preoperative selection of implant size
    • Schropp L, Stavropoulos A, Gotfredsen E, Wenzel A. Calibration of radiographs by a reference metal ball affects preoperative selection of implant size. Clin Oral Investig 2009; 13: 375-381.
    • (2009) Clin Oral Investig , vol.13 , pp. 375-381
    • Schropp, L.1    Stavropoulos, A.2    Gotfredsen, E.3    Wenzel, A.4
  • 15
    • 2942694212 scopus 로고    scopus 로고
    • A 7-year life table analysis from a prospective study on ITI implants with special emphasis on the use of short implants Results from a private practice
    • Nedir R, Bischof M, Briaux JM, Beyer S, Szmukler-Moncler S, Bernard JP. A 7-year life table analysis from a prospective study on ITI implants with special emphasis on the use of short implants. Results from a private practice. Clin Oral Implants Res 2004; 15: 150-157.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 150-157
    • Nedir, R.1    Bischof, M.2    Briaux, J.M.3    Beyer, S.4    Szmukler-Moncler, S.5    Bernard, J.P.6
  • 17
    • 84875174757 scopus 로고    scopus 로고
    • Software used to predict implant size from digital panoramic radiographs
    • Gotfredsen E, Schropp L, Wenzel A. Software used to predict implant size from digital panoramic radiographs. Int Congr Ser 2005; 1281-1414.
    • (2005) Int Congr ser , pp. 1281-1414
    • Gotfredsen, E.1    Schropp, L.2    Wenzel, A.3
  • 18
    • 77954569411 scopus 로고    scopus 로고
    • The evaluation of digital panoramic radiographs taken for implant dentistry in daily practice
    • Park JB. The evaluation of digital panoramic radiographs taken for implant dentistry in daily practice. Med Oral Patol Oral Cir Bucal 2010; 15: e663-666.
    • (2010) Med Oral Patol Oral Cir Bucal , vol.15
    • Park, J.B.1
  • 19
    • 78751559511 scopus 로고    scopus 로고
    • Magnification rate of digital panoramic radiographs and its effectiveness for preoperative assessment of dental implants
    • Kim YK, Park JY, Kim SG, Kim JS, Kim JD. Magnification rate of digital panoramic radiographs and its effectiveness for preoperative assessment of dental implants. Dentomaxillofac Radiol 2011; 40: 76-83.
    • (2011) Dentomaxillofac Radiol , vol.40 , pp. 76-83
    • Kim, Y.K.1    Park, J.Y.2    Kim, S.G.3    Kim, J.S.4    Kim, J.D.5
  • 20
    • 0035433138 scopus 로고    scopus 로고
    • Mathematical Analysis of Projection Errors in paralleling technique with respect to implant geometry
    • Schulze R, d'Hoedt B: Mathematical analysis of projection errors in "paralleling technique" with respect to implant geometry. Clin Oral Implants Res 2001; 10: 364-371.
    • (2001) Clin Oral Implants Res , vol.10 , pp. 364-371
    • Schulze, R.1    D'Hoedt, B.2
  • 21
    • 0034572132 scopus 로고    scopus 로고
    • Surgical procedures in partially edentulous patients with ITI implants
    • Buser D, von Arx T. Surgical procedures in partially edentulous patients with ITI implants. Clin Oral Implants Res 2000; 11: 83-100.
    • (2000) Clin Oral Implants Res , vol.11 , pp. 83-100
    • Buser, D.1    Von Arx, T.2
  • 22
    • 52749087498 scopus 로고    scopus 로고
    • Patient risk related to common dental radiographic examinations: The impact of 2007 International Commission on Radiological Protection recommendations regarding dose calculation
    • Ludlow JB, Davies-Ludlow LE, White SC. Patient risk related to common dental radiographic examinations: the impact of 2007 International Commission on Radiological Protection recommendations regarding dose calculation. J Am Dent Assoc 2008; 139: 1237-1243.
    • (2008) J Am Dent Assoc , vol.139 , pp. 1237-1243
    • Ludlow, J.B.1    Davies-Ludlow, L.E.2    White, S.C.3
  • 23
    • 69949169325 scopus 로고    scopus 로고
    • Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications
    • Loubele M, Bogaerts R, Van Dijck E, Pauwels R, Vanheusden S, Suetens P, et al. Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications. Eur J Radiol 2009; 71: 461-468.
    • (2009) Eur J Radiol , vol.71 , pp. 461-468
    • Loubele, M.1    Bogaerts, R.2    Van Dijck, E.3    Pauwels, R.4    Vanheusden, S.5    Suetens, P.6
  • 24
    • 0034208064 scopus 로고    scopus 로고
    • The accuracy of spiral tomography to assess bone quantity for the preoperative planning of implants in the posterior maxilla
    • Bou Serhal C, Jacobs R, Persoons M, Hermans R, van Steenberghe D. The accuracy of spiral tomography to assess bone quantity for the preoperative planning of implants in the posterior maxilla. Clin Oral Implants Res 2000; 11: 242-247.
    • (2000) Clin Oral Implants Res , vol.11 , pp. 242-247
    • Bou Serhal, C.1    Jacobs, R.2    Persoons, M.3    Hermans, R.4    Van Steenberghe, D.5
  • 25
    • 0034183344 scopus 로고    scopus 로고
    • Selection criteria for dental implant site imaging: A position paper of the American Academy of Oral and Maxillofacial radiology
    • Tyndall DA, Brooks SL. Selection criteria for dental implant site imaging: a position paper of the American Academy of Oral and Maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2000; 89: 630-637.
    • (2000) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.89 , pp. 630-637
    • Tyndall, D.A.1    Brooks, S.L.2
  • 27
    • 69249102664 scopus 로고    scopus 로고
    • Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners
    • Suomalainen A, Kiljunen T, Kaser Y, Peltola J, Kortesniemi M. Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners. Dentomaxillofac Radiol 2009; 38: 367-378.
    • (2009) Dentomaxillofac Radiol , vol.38 , pp. 367-378
    • Suomalainen, A.1    Kiljunen, T.2    Kaser, Y.3    Peltola, J.4    Kortesniemi, M.5
  • 28
    • 33644639722 scopus 로고    scopus 로고
    • Clinical applications of conebeam computed tomography in dental practice
    • Scarfe WC, Farman AG, Sukovic P. Clinical applications of conebeam computed tomography in dental practice. J Can Dent Assoc 2006; 72: 75-80.
    • (2006) J Can Dent Assoc , vol.72 , pp. 75-80
    • Scarfe, W.C.1    Farman, A.G.2    Sukovic, P.3
  • 29
    • 14244264415 scopus 로고    scopus 로고
    • Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom)
    • Lascala CA, Panella J, Marques MM. Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom). Dentomaxillofac Radiol 2004; 33: 291-294.
    • (2004) Dentomaxillofac Radiol , vol.33 , pp. 291-294
    • Lascala, C.A.1    Panella, J.2    Marques, M.M.3
  • 30
  • 33
    • 77949643532 scopus 로고    scopus 로고
    • Reproducibility of 3 different tracing methods based on cone beam computed tomography in determining the anatomical position of the mandibular canal
    • Gerlach NL, Meijer GJ, Maal TJ, Mulder J, Rangel FA, Borstlap WA, et al. Reproducibility of 3 different tracing methods based on cone beam computed tomography in determining the anatomical position of the mandibular canal. J Oral Maxillofac Surg 2012; 68: 811-817.
    • (2012) J Oral Maxillofac Surg , vol.68 , pp. 811-817
    • Gerlach, N.L.1    Meijer, G.J.2    Maal, T.J.3    Mulder, J.4    Rangel, F.A.5    Borstlap, W.A.6
  • 34
    • 0029314476 scopus 로고
    • Measurements of distances related to the mandibular canal in radiographs
    • Lindh C, Petersson A, Klinge B. Measurements of distances related to the mandibular canal in radiographs. Clin Oral Implants Res 1995; 6: 96-103.
    • (1995) Clin Oral Implants Res , vol.6 , pp. 96-103
    • Lindh, C.1    Petersson, A.2    Klinge, B.3
  • 35
    • 77954477109 scopus 로고    scopus 로고
    • Novel ultrasonic device to measure the distance from the bottom of the osteotome to various anatomic landmarks
    • Machtei EE, Zigdon H, Levin L, Peled M. Novel ultrasonic device to measure the distance from the bottom of the osteotome to various anatomic landmarks. J Periodontol 2011; 81: 1051-1055.
    • (2011) J Periodontol , vol.81 , pp. 1051-1055
    • MacHtei, E.E.1    Zigdon, H.2    Levin, L.3    Peled, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.