메뉴 건너뛰기




Volumn 13, Issue 3, 2013, Pages 3039-3055

A novel cell-based hybrid acoustic wave biosensor with impedimetric sensing capabilities

Author keywords

Bovine aortic endothelial cells; COMSOL multiphysics ; Impedance spectroscopy measurements; Quartz crystal microbalance; Resonant frequency; Thickness shear mode

Indexed keywords

BOVINE AORTIC ENDOTHELIAL CELLS; BULK ACOUSTIC WAVE RESONATOR; COMSOL MULTIPHYSICS; ELECTRIC CELLSUBSTRATE IMPEDANCE SENSING (ECIS); FINITE ELEMENT MODELING; IMPEDANCE SPECTROSCOPY MEASUREMENTS; RESONANT FREQUENCY MEASUREMENTS; THICKNESS SHEAR MODES;

EID: 84875148233     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s130303039     Document Type: Article
Times cited : (30)

References (42)
  • 2
    • 60349111587 scopus 로고    scopus 로고
    • Mammalian cell-based biosensors for pathogens and toxins
    • Banerjee, P.; Bhunia, A.K. Mammalian cell-based biosensors for pathogens and toxins. Trends Biotechnol. 2009, 27, 179-188.
    • (2009) Trends Biotechnol , vol.27 , pp. 179-188
    • Banerjee, P.1    Bhunia, A.K.2
  • 3
    • 38549093748 scopus 로고    scopus 로고
    • A novel and simple cell based detection system with a collagen-encapsulated B-lymphocyte cell line as a biosensor for rapid detection of pathogens and toxins
    • Banerjee, P.; Lenz, D.; Robinson, J.P.; Rickus, J.L.; Bhunia, A.K. A novel and simple cell based detection system with a collagen-encapsulated B-lymphocyte cell line as a biosensor for rapid detection of pathogens and toxins. Lab. Invest. 2008, 88, 196-206.
    • (2008) Lab. Invest , vol.88 , pp. 196-206
    • Banerjee, P.1    Lenz, D.2    Robinson, J.P.3    Rickus, J.L.4    Bhunia, A.K.5
  • 6
    • 0034157331 scopus 로고    scopus 로고
    • Cell-based biosensors
    • Ziegler, C. Cell-based biosensors. Fresenius' J. Anal. Chem. 2000, 366, 552-559.
    • (2000) Fresenius' J. Anal. Chem , vol.366 , pp. 552-559
    • Ziegler, C.1
  • 7
    • 84857363887 scopus 로고    scopus 로고
    • Acoustic wave based MEMS devices for biosensing applications
    • Voiculescu, I; Nordin, A.N. Acoustic wave based MEMS devices for biosensing applications. Biosens. Bioelectron. 2012, 33, 1-9.
    • (2012) Biosens. Bioelectron , vol.33 , pp. 1-9
    • Voiculescu, I.1    Nordin, A.N.2
  • 9
    • 37049112273 scopus 로고
    • Piezoelectric crystals for mass and chemical measurements
    • Alder, J.F.; McCallum, J.J. Piezoelectric crystals for mass and chemical measurements. Analyst 1983, 108, 1169-1189.
    • (1983) Analyst , vol.108 , pp. 1169-1189
    • Alder, J.F.1    McCallum, J.J.2
  • 10
    • 0141503495 scopus 로고    scopus 로고
    • Quartz crystal microbalance: A useful tool for studying thin polymer films and complex biomolecular systems at the solution-surface interface
    • Marx, K.A. Quartz crystal microbalance: A useful tool for studying thin polymer films and complex biomolecular systems at the solution-surface interface. Biomacromolecules 2003, 4, 1099-1120.
    • (2003) Biomacromolecules , vol.4 , pp. 1099-1120
    • Marx, K.A.1
  • 11
    • 67649289011 scopus 로고    scopus 로고
    • Linking biological and artificial olfaction: Biomimetic quartz crystal microbalance odor sensors
    • Wyszynski, B.; Nakamoto, T. Linking biological and artificial olfaction: biomimetic quartz crystal microbalance odor sensors. Trans. Electr. Electron. Eng. 2009, 4, 334-338.
    • (2009) Trans. Electr. Electron. Eng , vol.4 , pp. 334-338
    • Wyszynski, B.1    Nakamoto, T.2
  • 12
    • 34548485828 scopus 로고    scopus 로고
    • Monitoring cell adhesion by using thickness shear mode acoustic wave sensors
    • Li, F.; Wang, J.H.; Wang, Q.M. Monitoring cell adhesion by using thickness shear mode acoustic wave sensors. Biosens. Bioelectron. 2007, 23, 42-50.
    • (2007) Biosens. Bioelectron , vol.23 , pp. 42-50
    • Li, F.1    Wang, J.H.2    Wang, Q.M.3
  • 13
    • 27744562170 scopus 로고    scopus 로고
    • Measurements of fast fluctuation of viscoelastic properties with the quartz crystal microbalance
    • Pax, M.; Rieger, J.; Eibl, R.; Thielemann, C.; Johannsmann, D. Measurements of fast fluctuation of viscoelastic properties with the quartz crystal microbalance. Analyst 2005, 130, 1474-1477.
    • (2005) Analyst , vol.130 , pp. 1474-1477
    • Pax, M.1    Rieger, J.2    Eibl, R.3    Thielemann, C.4    Johannsmann, D.5
  • 14
    • 33747851741 scopus 로고    scopus 로고
    • Real-time analysis of cell-surface adhesive interactions using thickness shear mode resonator
    • Hong, S.; Ergezen, E.; Lec, R.; Barbee, K.A. Real-time analysis of cell-surface adhesive interactions using thickness shear mode resonator. Biomaterials 2006, 27, 5813-5820.
    • (2006) Biomaterials , vol.27 , pp. 5813-5820
    • Hong, S.1    Ergezen, E.2    Lec, R.3    Barbee, K.A.4
  • 15
    • 33744755697 scopus 로고    scopus 로고
    • A contribution to solve the problem of coating properties extraction in quartz crystal microbalance applications
    • Jimenez, Y.; Fernandez, R.; Torres, R.; Arnau, A. A contribution to solve the problem of coating properties extraction in quartz crystal microbalance applications. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 2006, 53, 1057-1072.
    • (2006) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.53 , pp. 1057-1072
    • Jimenez, Y.1    Fernandez, R.2    Torres, R.3    Arnau, A.4
  • 16
    • 0345708446 scopus 로고    scopus 로고
    • Transduction mechanism of acoustic-wave based chemical and biochemical sensors
    • Lucklum, R.; Hauptmann, P. Transduction mechanism of acoustic-wave based chemical and biochemical sensors. Meas. Sci. Technol. 2003, 14, 1854-1864.
    • (2003) Meas. Sci. Technol , vol.14 , pp. 1854-1864
    • Lucklum, R.1    Hauptmann, P.2
  • 17
    • 48449090042 scopus 로고    scopus 로고
    • Interaction of BSA protein with copper evaluated by electrochemical impedance spectroscopy and quartz crystal microbalance
    • Pinto, E.M.; Soares, D.M.; Brett, C.M.A. Interaction of BSA protein with copper evaluated by electrochemical impedance spectroscopy and quartz crystal microbalance. Electrochimica Acta 2008, 53, 7460-7466.
    • (2008) Electrochimica Acta , vol.53 , pp. 7460-7466
    • Pinto, E.M.1    Soares, D.M.2    Brett, C.M.A.3
  • 18
    • 33847353274 scopus 로고    scopus 로고
    • Detection and modelling of DNA hybridization by EIS measurements Mention of a polythiophenematrix suitable for electrochemically controlled gene delivery
    • Gautier, C.; Cougnon C.; Pilard, J.-F.; Casse, N.; Chenais, B.; Laulier, M. Detection and modelling of DNA hybridization by EIS measurements Mention of a polythiophenematrix suitable for electrochemically controlled gene delivery. Biosens. Bioelectron. 2007, 22, 2025-2031.
    • (2007) Biosens. Bioelectron , vol.22 , pp. 2025-2031
    • Gautier, C.1    Cougnon, C.2    Pilard, J.-F.3    Casse, N.4    Chenais, B.5    Laulier, M.6
  • 19
    • 76749085723 scopus 로고    scopus 로고
    • Combined QCM-D and EIS study of supported lipid bilayer formation and interaction with pore-forming peptides
    • Briand, E.; Zäch, M.; Svedhem, S.; Kasemo, B.; Petronis, S. Combined QCM-D and EIS study of supported lipid bilayer formation and interaction with pore-forming peptides. Analyst 2010, 135, 343-350.
    • (2010) Analyst , vol.135 , pp. 343-350
    • Briand, E.1    Zäch, M.2    Svedhem, S.3    Kasemo, B.4    Petronis, S.5
  • 20
    • 0033101199 scopus 로고    scopus 로고
    • Electric impedance spectroscopy using microchannels with integrated metal electrodes
    • Ayliffe, H.E.; Frazier, A.B.; Rabbitt, R.D. Electric impedance spectroscopy using microchannels with integrated metal electrodes. J. Microelectromech. Syst. 1999, 8, 50-57.
    • (1999) J. Microelectromech. Syst , vol.8 , pp. 50-57
    • Ayliffe, H.E.1    Frazier, A.B.2    Rabbitt, R.D.3
  • 24
    • 33846323280 scopus 로고    scopus 로고
    • Quantification of the heterogeneity in breast cancer cell lines using whole-cell impedance spectroscopy
    • Han, A.; Yang, L.; Frazier, A.B. Quantification of the heterogeneity in breast cancer cell lines using whole-cell impedance spectroscopy. Clin. Cancer Res. 2007, 13, 139-143.
    • (2007) Clin. Cancer Res , vol.13 , pp. 139-143
    • Han, A.1    Yang, L.2    Frazier, A.B.3
  • 25
    • 0028446185 scopus 로고
    • Biosensor that monitors cell morphology with electrical fields
    • Keese, C.R.; Giaever, I.A. Biosensor that monitors cell morphology with electrical fields. Eng. Med. Biol. Mag. 1994, 13, 402-408.
    • (1994) Eng. Med. Biol. Mag , vol.13 , pp. 402-408
    • Keese, C.R.1    Giaever, I.A.2
  • 26
    • 0025916059 scopus 로고
    • Micromotion of mammalian cells measured electrically
    • Giaever, I.; Keese, C.R. Micromotion of mammalian cells measured electrically. Proc. Nat. Acad. Sci. USA 1991, 88, 7896-7900.
    • (1991) Proc. Nat. Acad. Sci. USA , vol.88 , pp. 7896-7900
    • Giaever, I.1    Keese, C.R.2
  • 27
    • 0026069780 scopus 로고
    • Electric measurements can be used to monitor the attachment and spreading of cells in tissue culture
    • Mitra, P.; Keese, C.R.; Giaever, I. Electric measurements can be used to monitor the attachment and spreading of cells in tissue culture. Biotechniques 1991, 11, 504-10.
    • (1991) Biotechniques , vol.11 , pp. 504-510
    • Mitra, P.1    Keese, C.R.2    Giaever, I.3
  • 28
    • 0026738687 scopus 로고
    • Electrical method for detection of endothelial cell shape change in real time: Assessment of endothelial barrier function
    • Tiruppathi, C.; Malik, A.B.; Del Vecchio P.J.; Keese, C.R.; Giaever, I. Electrical method for detection of endothelial cell shape change in real time: Assessment of endothelial barrier function. Proc. Nat. Acad. Sci. USA 1992, 89, 7919-7923.
    • (1992) Proc. Nat. Acad. Sci. USA , vol.89 , pp. 7919-7923
    • Tiruppathi, C.1    Malik, A.B.2    Del Vecchio, P.J.3    Keese, C.R.4    Giaever, I.5
  • 29
    • 0027233863 scopus 로고
    • Monitoring motion of confluent cells in tissue culture. Exp
    • Lo, C.M.; Keese, C.R.; Giaever, I. Monitoring motion of confluent cells in tissue culture. Exp. Cell Res. 1993, 204, 102-109.
    • (1993) Cell Res , vol.204 , pp. 102-109
    • Lo, C.M.1    Keese, C.R.2    Giaever, I.3
  • 30
    • 0028339859 scopus 로고
    • Effect of the pSV2-neoplasmid on NIH 3T3 cell motion detected electrically
    • Pei, Z.; Keese, C.R.; Giaever, I.; Kurzawa, H.; Wilson, D.E. Effect of the pSV2-neoplasmid on NIH 3T3 cell motion detected electrically. Exp. Cell Res. 1994, 212, 225-229.
    • (1994) Exp. Cell Res , vol.212 , pp. 225-229
    • Pei, Z.1    Keese, C.R.2    Giaever, I.3    Kurzawa, H.4    Wilson, D.E.5
  • 31
    • 39449104524 scopus 로고    scopus 로고
    • Real-time monitoring primary cardiomyocyte adhesion based on electrochemical impedance spectroscopy and electrical cell-substrate impedance sensing
    • Qiu, Y.; Liao, R.; Zhang, X. Real-time monitoring primary cardiomyocyte adhesion based on electrochemical impedance spectroscopy and electrical cell-substrate impedance sensing. Anal. Chem. 2008, 80, 990-996.
    • (2008) Anal. Chem , vol.80 , pp. 990-996
    • Qiu, Y.1    Liao, R.2    Zhang, X.3
  • 32
    • 20644446484 scopus 로고    scopus 로고
    • Assessment of cytotoxicity by emerging impedance spectroscopy
    • Xiao, C.; Luong, J.H.T. Assessment of cytotoxicity by emerging impedance spectroscopy. Toxicol. Appl. Pharmacol. 2005, 206, 102-112.
    • (2005) Toxicol. Appl. Pharmacol , vol.206 , pp. 102-112
    • Xiao, C.1    Luong, J.H.T.2
  • 33
    • 0031772817 scopus 로고    scopus 로고
    • Cell-substrate impedance analysis of epithelial cell shape and micromotion upon challenge with bacterial proteins that perturb extracellular matrix and cytoskeleton
    • Ko, K.S.C.; Lo, C.M.; Ferrier, J.; Hannam, P.; Tamura, M.; McBridec, B.C.; Ellen, R.P. Cell-substrate impedance analysis of epithelial cell shape and micromotion upon challenge with bacterial proteins that perturb extracellular matrix and cytoskeleton. J. Microbiol. Methods 1998, 34, 125-132.
    • (1998) J. Microbiol. Methods , vol.34 , pp. 125-132
    • Ko, K.S.C.1    Lo, C.M.2    Ferrier, J.3    Hannam, P.4    Tamura, M.5    McBridec, B.C.6    Ellen, R.P.7
  • 34
    • 1542303757 scopus 로고    scopus 로고
    • Impedance based Biosensor Array for Monitoring Mammalian Cell Behavior
    • Toronto, ON, Canada, 22-24 October
    • Huang, X.; Greve, D.W.; Nguyen, D.D.; Domach, M.M. Impedance based Biosensor Array for Monitoring Mammalian Cell Behavior. In Proceedings of IEEE Sensors, Toronto, ON, Canada, 22-24 October 2003.
    • (2003) Proceedings of IEEE Sensors
    • Huang, X.1    Greve, D.W.2    Nguyen, D.D.3    Domach, M.M.4
  • 37
    • 33746520657 scopus 로고    scopus 로고
    • Selection of a battery of rapid toxicity sensors for drinking water evaluation
    • Van der Schalie, W.H.; James, R.R.; Gargan, T.P. Selection of a battery of rapid toxicity sensors for drinking water evaluation. Biosens. Bioelectron. 2006, 22, 18-27.
    • (2006) Biosens. Bioelectron , vol.22 , pp. 18-27
    • Van der Schalie, W.H.1    James, R.R.2    Gargan, T.P.3
  • 38
    • 68949128764 scopus 로고    scopus 로고
    • On mass loading and dissipation measured with acoustic wave sensors: A review
    • doi:10.1155/2009/943125
    • Voinova, M.V. On mass loading and dissipation measured with acoustic wave sensors: A review. J. Sens. 2009, doi:10.1155/2009/943125.
    • (2009) J. Sens
    • Voinova, M.V.1
  • 39
    • 1642602350 scopus 로고    scopus 로고
    • Influence of interchannel spacing on the dynamical properties of multichannel quartz crystal microbalance
    • Shen, F.; Lu, P. Influence of interchannel spacing on the dynamical properties of multichannel quartz crystal microbalance. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 2004, 51, 249-253.
    • (2004) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.51 , pp. 249-253
    • Shen, F.1    Lu, P.2
  • 40
    • 0034775319 scopus 로고    scopus 로고
    • Ultrasensitive quartz crystal microbalance sensors for detection of M13-Phages in liquids
    • Uttenthaler, E.; Schraml, M.; Mandel, J.; Drost, S. Ultrasensitive quartz crystal microbalance sensors for detection of M13-Phages in liquids. Biosens. Bioelectron. 2001, 16, 735-743.
    • (2001) Biosens Bioelectron , vol.16 , pp. 735-743
    • Uttenthaler, E.1    Schraml, M.2    Mandel, J.3    Drost, S.4
  • 41
    • 84951279351 scopus 로고
    • Use of vibrating quartz for thin film weighing and microweighing
    • U
    • Sauerbrey, G. Use of vibrating quartz for thin film weighing and microweighing. Z. Phys. 1959, 155, 206-222.
    • (1959) Z. Phys , vol.155 , pp. 206-222
    • Sauerbrey, G.1
  • 42
    • 37549028413 scopus 로고    scopus 로고
    • Characterization of viscoelastic properties of cell layer by using acoustic wave resonator sensors
    • Li, F.; Wang, J.H.C.; Wang, Q.M. Characterization of viscoelastic properties of cell layer by using acoustic wave resonator sensors. Sens. Actuators B 2008, 128, 399-406.
    • (2008) Sens. Actuators B , vol.128 , pp. 399-406
    • Li, F.1    Wang, J.H.C.2    Wang, Q.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.