메뉴 건너뛰기




Volumn 35, Issue 2, 2013, Pages 225-228

Influence of in vitro hemolysis on nucleated red blood cells and reticulocyte counts

Author keywords

Hemolysis; Hemolyzed specimens; Nucleated red blood cells; Preanalytical variability; Reticulocytes

Indexed keywords

EDETIC ACID;

EID: 84875055851     PISSN: 17515521     EISSN: 1751553X     Source Type: Journal    
DOI: 10.1111/ijlh.12012     Document Type: Article
Times cited : (7)

References (11)
  • 1
    • 65349101612 scopus 로고    scopus 로고
    • Quality counts: new parameters in blood cell counting
    • Briggs C. Quality counts: new parameters in blood cell counting. Int J Lab Hematol 2009;31:277-97.
    • (2009) Int J Lab Hematol , vol.31 , pp. 277-297
    • Briggs, C.1
  • 2
    • 33645757592 scopus 로고    scopus 로고
    • Preanalytical variability: the dark side of the moon in laboratory testing
    • Lippi G, Guidi GC, Mattiuzzi C, Plebani M. Preanalytical variability: the dark side of the moon in laboratory testing. Clin Chem Lab Med 2006;44:358-65.
    • (2006) Clin Chem Lab Med , vol.44 , pp. 358-365
    • Lippi, G.1    Guidi, G.C.2    Mattiuzzi, C.3    Plebani, M.4
  • 5
    • 84856426677 scopus 로고    scopus 로고
    • Erythrocyte mechanical fragility is increased in patients with type 2 diabetes
    • Lippi G, Mercadanti M, Aloe R, Targher G. Erythrocyte mechanical fragility is increased in patients with type 2 diabetes. Eur J Intern Med 2012b;23:150-3.
    • (2012) Eur J Intern Med , vol.23 , pp. 150-153
    • Lippi, G.1    Mercadanti, M.2    Aloe, R.3    Targher, G.4
  • 7
    • 84859812541 scopus 로고    scopus 로고
    • Interference studies: focus on blood cell lysates preparation and testing
    • Lippi G. Interference studies: focus on blood cell lysates preparation and testing. Clin Lab 2012;58:351-5.
    • (2012) Clin Lab , vol.58 , pp. 351-355
    • Lippi, G.1
  • 9
    • 0037330289 scopus 로고    scopus 로고
    • Development and clinical application of nucleated red blood cell counting and staging on the automated haematology analyser XE-2100
    • Wang FS, Itose Y, Tsuji T, Hamaguchi Y, Hirai K, Sakata T. Development and clinical application of nucleated red blood cell counting and staging on the automated haematology analyser XE-2100. Clin Lab Haematol 2003;25:17-23.
    • (2003) Clin Lab Haematol , vol.25 , pp. 17-23
    • Wang, F.S.1    Itose, Y.2    Tsuji, T.3    Hamaguchi, Y.4    Hirai, K.5    Sakata, T.6
  • 10
    • 0002183637 scopus 로고    scopus 로고
    • Performance evaluation of the Sysmex XE-2100 hematology analyzer
    • Walters J, Garrity P. Performance evaluation of the Sysmex XE-2100 hematology analyzer. Lab Hematol 2000;6:83-92.
    • (2000) Lab Hematol , vol.6 , pp. 83-92
    • Walters, J.1    Garrity, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.