메뉴 건너뛰기




Volumn 48, Issue 4, 2013, Pages 223-230

Quantitative and semiquantitative measures of regional pulmonary microvascular perfusion by magnetic resonance imaging and their relationships to global lung perfusion and lung diffusing capacity: The multiethnic study of atherosclerosis chronic obstructive pulmonary disease study

Author keywords

Chronic obstructive pulmonary disease (COPD); Dynamic contrast enhanced MRI; Lung diffusing capacity; Pulmonary microvascular blood flow; Quantitative perfusion maps

Indexed keywords

AGED; ARTICLE; CHRONIC OBSTRUCTIVE LUNG DISEASE; CONTRAST ENHANCEMENT; CONTROLLED STUDY; FEMALE; FORCED EXPIRATORY VOLUME; GLOBAL LUNG PERFUSION; HUMAN; LUNG BLOOD FLOW; LUNG DIFFUSION CAPACITY; LUNG FUNCTION; LUNG PARENCHYMA; LUNG PERFUSION; MAJOR CLINICAL STUDY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS;

EID: 84874931750     PISSN: 00209996     EISSN: 15360210     Source Type: Journal    
DOI: 10.1097/RLI.0b013e318281057d     Document Type: Article
Times cited : (49)

References (34)
  • 1
    • 79551610879 scopus 로고    scopus 로고
    • The role of the bronchial microvasculature in the airway remodelling in asthma and COPD
    • Zanini A, Chetta A, Imperatori AS, et al. The role of the bronchial microvasculature in the airway remodelling in asthma and COPD. Respir Res. 2010; 11:132.
    • (2010) Respir Res. , Issue.11 , pp. 132
    • Zanini, A.1    Chetta, A.2    Imperatori, A.S.3
  • 4
    • 79958065567 scopus 로고    scopus 로고
    • Ventilation/perfusion SPECT in chronic obstructive pulmonary disease: An evaluation by reference to symptoms, spirometric lung function and emphysema, as assessed with HRCT
    • Jogi J, Ekberg M, Jonson B, et al. Ventilation/perfusion SPECT in chronic obstructive pulmonary disease: an evaluation by reference to symptoms, spirometric lung function and emphysema, as assessed with HRCT. Eur J Nucl Med Mol Imaging. 2011;38:1344-1352.
    • (2011) Eur J Nucl Med Mol Imaging. , vol.38 , pp. 1344-1352
    • Jogi, J.1    Ekberg, M.2    Jonson, B.3
  • 6
    • 0022497731 scopus 로고
    • Quantitative measurement of regional pulmonary blood flow with positron emission tomography
    • Mintun MA, Ter-Pogossian MM, Green MA, et al. Quantitative measurement of regional pulmonary blood flow with positron emission tomography. J Appl Physiol. 1986;60:317-326. (Pubitemid 16024052)
    • (1986) Journal of Applied Physiology , vol.60 , Issue.1 , pp. 317-326
    • Mintun, M.A.1    Ter-Pogossian, M.M.2    Green, M.A.3
  • 7
    • 0028931483 scopus 로고
    • Measurement of regional pulmonary blood flow with PET
    • Schuster DP, Kaplan JD, Gauvain K, et al. Measurement of regional pulmonary blood flow with PET. J Nucl Med. 1995;36:371-377.
    • (1995) J Nucl Med. , vol.36 , pp. 371-377
    • Schuster, D.P.1    Kaplan, J.D.2    Gauvain, K.3
  • 8
    • 4344601293 scopus 로고    scopus 로고
    • Quantitative assessment of regional pulmonary perfusion in the entire lung using three-dimensional ultrafast dynamic contrast-enhanced magnetic resonance imaging: Preliminary experience in 40 subjects
    • DOI 10.1002/jmri.20137
    • Ohno Y, Hatabu H, Murase K, et al. Quantitative assessment of regional pulmonary perfusion in the entire lung using three-dimensional ultrafast dynamic contrast-enhanced magnetic resonance imaging: preliminary experience in 40 subjects. J Magn Reson Imaging. 2004;20:353-365. (Pubitemid 39121931)
    • (2004) Journal of Magnetic Resonance Imaging , vol.20 , Issue.3 , pp. 353-365
    • Ohno, Y.1    Hatabu, H.2    Murase, K.3    Higashino, T.4    Kawamitsu, H.5    Watanabe, H.6    Takenaka, D.7    Fujii, M.8    Sugimura, K.9
  • 9
    • 65349168393 scopus 로고    scopus 로고
    • Adult Tetralogy of Fallot: Quantitative assessment of pulmonary perfusion with time-resolved three dimensional magnetic resonance angiography
    • Tomasian A, Krishnam MS, Lohan DG, et al. Adult Tetralogy of Fallot: quantitative assessment of pulmonary perfusion with time-resolved three dimensional magnetic resonance angiography. Invest Radiol. 2009;44:31-37.
    • (2009) Invest Radiol. , vol.44 , pp. 31-37
    • Tomasian, A.1    Krishnam, M.S.2    Lohan, D.G.3
  • 10
    • 4143052375 scopus 로고    scopus 로고
    • Quantification of pulmonary blood flow and volume in healthy volunteers by dynamic contrast-enhanced magnetic resonance imaging using a parallel imaging technique
    • DOI 10.1097/01.rli.0000133813.22873.47
    • Nikolaou K, Schoenberg SO, Brix G, et al. Quantification of pulmonary blood flow and volume in healthy volunteers by dynamic contrast-enhanced magnetic resonance imaging using a parallel imaging technique. Invest Radiol. 2004;39:537-545. (Pubitemid 39096771)
    • (2004) Investigative Radiology , vol.39 , Issue.9 , pp. 537-545
    • Nikolaou, K.1    Schoenberg, S.O.2    Brix, G.3    Goldman, J.P.4    Attenberger, U.5    Kuehn, B.6    Dietrich, O.7    Reiser, M.F.8
  • 11
    • 33845336875 scopus 로고    scopus 로고
    • Dual-bolus approach to quantitative measurement of pulmonary perfusion by contrast-enhanced MRI
    • DOI 10.1002/jmri.20747
    • Risse F, Semmler W, Kauczor HU, et al. Dual-bolus approach to quantitative measurement of pulmonary perfusion by contrast-enhanced MRI. J Magn Reson Imaging. 2006;24:1284-1290. (Pubitemid 44871872)
    • (2006) Journal of Magnetic Resonance Imaging , vol.24 , Issue.6 , pp. 1284-1290
    • Risse, F.1    Semmler, W.2    Kauczor, H.-U.3    Fink, C.4
  • 12
    • 77049181625 scopus 로고
    • On the theory of the indicator-dilution method for measurement of blood flow and volume
    • Meier P, Zierler KL. On the theory of the indicator-dilution method for measurement of blood flow and volume. J Appl Physiol. 1954;6:731-744.
    • (1954) J Appl Physiol. , vol.6 , pp. 731-744
    • Meier, P.1    Zierler, K.L.2
  • 14
    • 67650093743 scopus 로고    scopus 로고
    • Quantitative contrast-enhanced perfusion measurements of the human lung using the prebolus approach
    • Oechsner M, Muhlhausler M, Ritter CO, et al. Quantitative contrast-enhanced perfusion measurements of the human lung using the prebolus approach. J Magn Reson Imaging. 2009;30:104-111.
    • (2009) J Magn Reson Imaging. , vol.30 , pp. 104-111
    • Oechsner, M.1    Muhlhausler, M.2    Ritter, C.O.3
  • 15
    • 77949528328 scopus 로고    scopus 로고
    • The association of pipe and cigar use with cotinine levels, lung function, and airflow obstruction: A cross-sectional study
    • Rodriguez J, Jiang R, Johnson WC, et al. The association of pipe and cigar use with cotinine levels, lung function, and airflow obstruction: a cross-sectional study. Ann Intern Med. 2010;152:201-210.
    • (2010) Ann Intern Med. , vol.152 , pp. 201-210
    • Rodriguez, J.1    Jiang, R.2    Johnson, W.C.3
  • 17
    • 45749118767 scopus 로고    scopus 로고
    • Plasma carbonyls do not correlate with lung function or computed tomography measures of lung density in older smokers
    • Mesa-Vela S, Chih-Ching Y, Austin JHM, et al. Plasma carbonyls do not correlate with lung function or computed tomography measures of lung density in older smokers. Biomarkers. 2008;13:422-434.
    • (2008) Biomarkers. , vol.13 , pp. 422-434
    • Mesa-Vela, S.1    Chih-Ching, Y.2    Austin, J.H.M.3
  • 19
    • 33746759422 scopus 로고    scopus 로고
    • Improvement of quantification of myocardial first-pass perfusion mapping: A temporal and spatial wavelet denoising method
    • DOI 10.1002/mrm.20950
    • Goldstein TA, Zhang H, Misselwitz B, et al. Improvement of quantification of myocardial first-pass perfusion mapping: a temporal and spatial wavelet denoising method. Magn Reson Med. 2006;56:439-445. (Pubitemid 44162792)
    • (2006) Magnetic Resonance in Medicine , vol.56 , Issue.2 , pp. 439-445
    • Goldstein, T.A.1    Zhang, H.2    Misselwitz, B.3    Gropler, R.G.4    Zheng, J.5
  • 20
    • 0031906266 scopus 로고    scopus 로고
    • Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolution
    • DOI 10.1118/1.598163
    • Jerosch-Herold M, Wilke N, Stillman AE. Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolution. Med Phys. 1998;25:73-84. (Pubitemid 28063691)
    • (1998) Medical Physics , vol.25 , Issue.1 , pp. 73-84
    • Jerosch-Herold, M.1    Wilke, N.2    Stillman, A.E.3    Wilson, R.F.4
  • 25
    • 74849125941 scopus 로고    scopus 로고
    • Performance of American Thoracic SocietyYrecommended spirometry reference values in a multiethnic sample of adults: The Multi-Ethnic Study of Atherosclerosis (MESA) lung study
    • Hankinson JL, Kawut SM, Shahar E, et al. Performance of American Thoracic SocietyYrecommended spirometry reference values in a multiethnic sample of adults: the Multi-Ethnic Study of Atherosclerosis (MESA) lung study. Chest. 2010;137:138-145.
    • (2010) Chest. , vol.137 , pp. 138-145
    • Hankinson, J.L.1    Kawut, S.M.2    Shahar, E.3
  • 26
    • 0000160155 scopus 로고
    • A theoretical and experimental analysis of anomalies in the estimation of pulmonary diffusing capacity by the single breath method
    • Jones RS, Meade F. A theoretical and experimental analysis of anomalies in the estimation of pulmonary diffusing capacity by the single breath method. Q J Exp Physiol Cogn Med Sci. 1961;46:131-143.
    • (1961) Q J Exp Physiol Cogn Med Sci. , vol.46 , pp. 131-143
    • Jones, R.S.1    Meade, F.2
  • 29
    • 72749123965 scopus 로고    scopus 로고
    • Lung volume reference values for women and men 65 to 85 years of age
    • Garcia-Rio F, Dorgham A, Pino JM, et al. Lung volume reference values for women and men 65 to 85 years of age. Am J Respir Crit Care Med. 2009;180:1083-1091.
    • (2009) Am J Respir Crit Care Med. , vol.180 , pp. 1083-1091
    • Garcia-Rio, F.1    Dorgham, A.2    Pino, J.M.3
  • 32
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • DOI 10.1191/096228099673819272
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Statist Methods Med Res. 1999;8:135-160. (Pubitemid 29425900)
    • (1999) Statistical Methods in Medical Research , vol.8 , Issue.2 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 33
    • 84864684778 scopus 로고    scopus 로고
    • Quantitative evaluation of MR perfusion imaging using blood pool contrast agent in subjects without pulmonary diseases and in patients with pulmonary embolism
    • Hansch A, Kohlmann P, Hinneburg U, et al. Quantitative evaluation of MR perfusion imaging using blood pool contrast agent in subjects without pulmonary diseases and in patients with pulmonary embolism. Eur Radiol. 2012;22:1748-1756.
    • (2012) Eur Radiol. , vol.22 , pp. 1748-1756
    • Hansch, A.1    Kohlmann, P.2    Hinneburg, U.3
  • 34
    • 0027481892 scopus 로고
    • Pitfalls in MR measurement of tissue blood flow with intravascular tracers: Which mean transit time?
    • Weisskoff RM, Chesler D, Boxerman JL, et al. Pitfalls in MR measurement of tissue blood flow with intravascular tracers: which mean transit time? Magn Reson Med. 1993;29:553-558. (Pubitemid 23112762)
    • (1993) Magnetic Resonance in Medicine , vol.29 , Issue.4 , pp. 553-558
    • Weisskoff, R.M.1    Chesler, D.2    Boxerman, J.L.3    Rosen, B.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.