메뉴 건너뛰기




Volumn 56, Issue 2, 2006, Pages 439-445

Improvement of quantification of myocardial first-pass perfusion mapping: A temporal and spatial wavelet denoising method

Author keywords

Denoising; MRI; Myocardial perfusion; Vasodilation; Wavelet

Indexed keywords

DISEASES; IMAGE ENHANCEMENT; MAGNETIC RESONANCE IMAGING; MAPPING; PIXELS; SIGNAL TO NOISE RATIO; WAVELET ANALYSIS;

EID: 33746759422     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.20950     Document Type: Article
Times cited : (16)

References (27)
  • 1
    • 0037355514 scopus 로고    scopus 로고
    • Assessment of ischemic heart disease using magnetic resonance first-pass perfusion imaging
    • Muhling O, Jerosch-Herold M, Nabauer M, Wilke N. Assessment of ischemic heart disease using magnetic resonance first-pass perfusion imaging. Herz 2003;28:82-89.
    • (2003) Herz , vol.28 , pp. 82-89
    • Muhling, O.1    Jerosch-Herold, M.2    Nabauer, M.3    Wilke, N.4
  • 2
    • 0036298279 scopus 로고    scopus 로고
    • Mapping myocardial perfusion with an intravascular MR contrast agent: Robustness of deconvolution methods at various blood flows
    • Neyran B, Janier MF, Casali C, Revel D, Canet Soulas EP. Mapping myocardial perfusion with an intravascular MR contrast agent: robustness of deconvolution methods at various blood flows. Magn Reson Med 2002;48:166-179.
    • (2002) Magn Reson Med , vol.48 , pp. 166-179
    • Neyran, B.1    Janier, M.F.2    Casali, C.3    Revel, D.4    Canet Soulas, E.P.5
  • 3
    • 33746712272 scopus 로고    scopus 로고
    • Adaptive magnetic resonance image denoising using mixture model and wavelet shrinkage
    • Sydney, Australia
    • Jiang L, Yang W. Adaptive magnetic resonance image denoising using mixture model and wavelet shrinkage. Digital Image Comput: Techniques and Applications. Sydney, Australia, 2003. p. 831-838.
    • (2003) Digital Image Comput: Techniques and Applications , pp. 831-838
    • Jiang, L.1    Yang, W.2
  • 4
    • 1642357547 scopus 로고    scopus 로고
    • Denoising functional MR images: A comparison of wavelet denoising and Gaussian smoothing
    • Wink AM, Roerdink JBTM. Denoising functional MR images: a comparison of wavelet denoising and Gaussian smoothing. Med Imaging IEEE 2000;23:374-387.
    • (2000) Med Imaging IEEE , vol.23 , pp. 374-387
    • Wink, A.M.1    Roerdink, J.B.T.M.2
  • 6
    • 0034981548 scopus 로고    scopus 로고
    • Pharmacokinetics of Gadomer, a new dendritic magnetic resonance contrast agent
    • Misselwitz B, Schmitt-Willich H, Ebert W, Frenzel T, Weinmann HJ. Pharmacokinetics of Gadomer, a new dendritic magnetic resonance contrast agent. MAGMA 2001;12:128-134.
    • (2001) MAGMA , vol.12 , pp. 128-134
    • Misselwitz, B.1    Schmitt-Willich, H.2    Ebert, W.3    Frenzel, T.4    Weinmann, H.J.5
  • 7
    • 0035119402 scopus 로고    scopus 로고
    • Contrast-enhanced MRI of coronary arteries: Comparison of intravascular and extravascular contrast agents and technical considerations
    • Li D, Zheng J, Weinmann HJ, Bae KT, Haacke EM. Contrast-enhanced MRI of coronary arteries: comparison of intravascular and extravascular contrast agents and technical considerations. Radiology 2001;218:670-678.
    • (2001) Radiology , vol.218 , pp. 670-678
    • Li, D.1    Zheng, J.2    Weinmann, H.J.3    Bae, K.T.4    Haacke, E.M.5
  • 13
    • 0038511629 scopus 로고    scopus 로고
    • Noise reduction by wavelet thresholding. 2001
    • New York: Springer-Verlag
    • Jansen M, Verlag S. Noise reduction by wavelet thresholding. 2001. In: Lecture notes in Statistics, Vol. 161. New York: Springer-Verlag.
    • Lecture Notes in Statistics , vol.161
    • Jansen, M.1    Verlag, S.2
  • 14
    • 84950459514 scopus 로고
    • Adapting to unknown smoothness via wavelet shrinkage
    • Donoho DL, Johnstone IM. Adapting to unknown smoothness via wavelet shrinkage. J Am Statist Assoc 1995;90:1200-1224,
    • (1995) J Am Statist Assoc , vol.90 , pp. 1200-1224
    • Donoho, D.L.1    Johnstone, I.M.2
  • 16
    • 0035999417 scopus 로고    scopus 로고
    • Myocardial blood flow quantification with MRI by model-independent deconvolution
    • Jerosch-Herold M, Swingen C, Seethamraju RT. Myocardial blood flow quantification with MRI by model-independent deconvolution. Med Phys 2002;29:886-897.
    • (2002) Med Phys , vol.29 , pp. 886-897
    • Jerosch-Herold, M.1    Swingen, C.2    Seethamraju, R.T.3
  • 17
    • 0031906266 scopus 로고    scopus 로고
    • Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolulion
    • Jerosch-Herold M, Wilke N, Stillman AE. Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolulion. Med Phys 1998;25:73-84.
    • (1998) Med Phys , vol.25 , pp. 73-84
    • Jerosch-Herold, M.1    Wilke, N.2    Stillman, A.E.3
  • 19
    • 0033989015 scopus 로고    scopus 로고
    • Complex denoising of MR data via wavelet analysis: Application for functional MRI
    • Zaroubi S, Geolman G. Complex denoising of MR data via wavelet analysis: application for functional MRI. J Magn Reson Imaging 2000; 18:59-68.
    • (2000) J Magn Reson Imaging , vol.18 , pp. 59-68
    • Zaroubi, S.1    Geolman, G.2
  • 20
    • 0033062659 scopus 로고    scopus 로고
    • Wavelet packet denoising of magnetic resonance images: Importance of Rician noise at low SNR
    • Wood JC. Johnson KM. Wavelet packet denoising of magnetic resonance images: importance of Rician noise at low SNR. Magn Reson Med 1999;41:631-635.
    • (1999) Magn Reson Med , vol.41 , pp. 631-635
    • Wood, J.C.1    Johnson, K.M.2
  • 22
    • 0036788282 scopus 로고    scopus 로고
    • Single-vessel coronary artery stenosis: Myocardial perfusion imaging with Gadomer-17 first-pass MR imaging in a swine model of comparison with gadopentetate dimeglumine
    • Gerber BL, Bluemke DA, Chin BB, Boston RC, Heldman AW, Lima JA, Kraitchman DL. Single-vessel coronary artery stenosis: myocardial perfusion imaging with Gadomer-17 first-pass MR imaging in a swine model of comparison with gadopentetate dimeglumine. Radiology 2002;225:104-112.
    • (2002) Radiology , vol.225 , pp. 104-112
    • Gerber, B.L.1    Bluemke, D.A.2    Chin, B.B.3    Boston, R.C.4    Heldman, A.W.5    Lima, J.A.6    Kraitchman, D.L.7
  • 23
    • 0037507447 scopus 로고    scopus 로고
    • The significance of perfusion defect at myocardial perfusion MR imaging in a cat model of acute reperfused myocardial infarction
    • Goo HW, Kim DH, Lee SS, Park SB, Lim TH. The significance of perfusion defect at myocardial perfusion MR imaging in a cat model of acute reperfused myocardial infarction. Kor J Radiol 2002;3:235-239.
    • (2002) Kor J Radiol , vol.3 , pp. 235-239
    • Goo, H.W.1    Kim, D.H.2    Lee, S.S.3    Park, S.B.4    Lim, T.H.5
  • 25
    • 0026017365 scopus 로고
    • Effects of barium-induced cardiac contraction on large- and small-vessel intramyocardial blood volume
    • Judd RM, Levy BI. Effects of barium-induced cardiac contraction on large- and small-vessel intramyocardial blood volume. Circ Res 1991; 68:217-225.
    • (1991) Circ Res , vol.68 , pp. 217-225
    • Judd, R.M.1    Levy, B.I.2
  • 26
    • 0037310235 scopus 로고    scopus 로고
    • Quantification of renal perfusion using an intravascular contrast agent (part 1): Results in a canine model
    • Aumann S, Schoenberg SO, Just A, Briley-Saebo K, Bjornerud A, Bock M, Brix G. Quantification of renal perfusion using an intravascular contrast agent (part 1): results in a canine model. Magn Reson Med 2003;49:276-287.
    • (2003) Magn Reson Med , vol.49 , pp. 276-287
    • Aumann, S.1    Schoenberg, S.O.2    Just, A.3    Briley-Saebo, K.4    Bjornerud, A.5    Bock, M.6    Brix, G.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.