-
1
-
-
37349049968
-
Safety of magnetic resonance imaging in patients with cardiovascular devices: An American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization
-
American Heart Association Committee on Diagnostic and Interventional Cardiac Catheterization; American Heart Association Council on Clinical Cardiology; American Heart Association Council on Cardiovascular Radiology and Intervention.
-
Levine GN, Gomes AS, Arai AE, et al. American Heart Association Committee on Diagnostic and Interventional Cardiac Catheterization; American Heart Association Council on Clinical Cardiology; American Heart Association Council on Cardiovascular Radiology and Intervention. Safety of magnetic resonance imaging in patients with cardiovascular devices: an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance. Circulation 2007; 116: 2878-2891.
-
(2007)
Circulation
, vol.116
, pp. 2878-2891
-
-
Levine, G.N.1
Gomes, A.S.2
Arai, A.E.3
-
2
-
-
20344387680
-
Do we need pacemakers resistant to magnetic resonance imaging?
-
Irnich W, Irnich B, Bartsch C, Stertmann WA, Gufler H, Weiler G,. Do we need pacemakers resistant to magnetic resonance imaging? Europace 2005; 7: 353-365.
-
(2005)
Europace
, vol.7
, pp. 353-365
-
-
Irnich, W.1
Irnich, B.2
Bartsch, C.3
Stertmann, W.A.4
Gufler, H.5
Weiler, G.6
-
3
-
-
33748752144
-
Strategy for safe performance of extrathoracic MRI at 1.5 T in the presence of cardiac pacemakers in non-pacemaker dependent patients: A prospective study with 115 examinations
-
Sommer T, Naehle CP, Yang A, et al. Strategy for safe performance of extrathoracic MRI at 1.5 T in the presence of cardiac pacemakers in non-pacemaker dependent patients: A prospective study with 115 examinations. Circulation 2006; 114: 1285-1292.
-
(2006)
Circulation
, vol.114
, pp. 1285-1292
-
-
Sommer, T.1
Naehle, C.P.2
Yang, A.3
-
4
-
-
0033500251
-
Concerns about sources of electromagnetic interference in patients with pacemakers
-
Sakakibara Y, Mitsui T,. Concerns about sources of electromagnetic interference in patients with pacemakers. Jpn Heart J 1999; 40: 737-743.
-
(1999)
Jpn Heart J
, vol.40
, pp. 737-743
-
-
Sakakibara, Y.1
Mitsui, T.2
-
5
-
-
44649139918
-
Magnetic resonance imaging in individuals with cardiovascular implantable electronic devices
-
Roguin A, Schwitter J, Vahlhaus C, Lombardi M, Brugada J, Vardas P, Auricchio A, et al. Magnetic resonance imaging in individuals with cardiovascular implantable electronic devices. Europace 2008; 10: 336-346.
-
(2008)
Europace
, vol.10
, pp. 336-346
-
-
Roguin, A.1
Schwitter, J.2
Vahlhaus, C.3
Lombardi, M.4
Brugada, J.5
Vardas, P.6
Auricchio, A.7
-
6
-
-
18044393463
-
Current clinical issues for MRI scanning of pacemaker and defibrillator patients
-
Kalin R, Stanton MS,. Current clinical issues for MRI scanning of pacemaker and defibrillator patients. Pacing Clin Electrophysiol 2005; 28: 326-328.
-
(2005)
Pacing Clin Electrophysiol
, vol.28
, pp. 326-328
-
-
Kalin, R.1
Stanton, M.S.2
-
7
-
-
79952404347
-
First MRI-safe pacemaker receives conditional approval from FDA
-
Mitka M,. first MRI-safe pacemaker receives conditional approval from FDA. JAMA 2011; 305: 985-986.
-
(2011)
JAMA
, vol.305
, pp. 985-986
-
-
Mitka, M.1
-
8
-
-
0036800991
-
Pacemaker reed switch behavior in 0.5, 1.5, and 3.0 Tesla magnetic resonance imaging units: Are reed switches always closed in strong magnetic fields?
-
Luechinger R, Duru F, Zeijlemaker VA, Scheidegger MB, Boesiger P, Candinas R,. Pacemaker reed switch behavior in 0.5, 1.5, and 3.0 Tesla magnetic resonance imaging units: Are reed switches always closed in strong magnetic fields? Pacing Clin Electrophysiol 2002; 25: 1419-1423.
-
(2002)
Pacing Clin Electrophysiol
, vol.25
, pp. 1419-1423
-
-
Luechinger, R.1
Duru, F.2
Zeijlemaker, V.A.3
Scheidegger, M.B.4
Boesiger, P.5
Candinas, R.6
-
9
-
-
84855575767
-
Initial experience with magnetic resonance imaging-safe pacemakers
-
Jung W, Zvereva V, Hajredini B, Jäckle S,. Initial experience with magnetic resonance imaging-safe pacemakers. J Interv Card Electrophysiol 2011; 32: 213-219.
-
(2011)
J Interv Card Electrophysiol
, vol.32
, pp. 213-219
-
-
Jung, W.1
Zvereva, V.2
Hajredini, B.3
Jäckle, S.4
-
10
-
-
0034077462
-
MR imaging and cardiac pacemakers: In-vitro evaluation and in-vivo studies in 51 patients at 0.5 T
-
Sommer T, Vahlhaus C, Lauck G, von Smekal A, Reinke M, Hofer U, Block W, et al. MR imaging and cardiac pacemakers: In-vitro evaluation and in-vivo studies in 51 patients at 0.5 T. Radiology 2000; 215: 869-879.
-
(2000)
Radiology
, vol.215
, pp. 869-879
-
-
Sommer, T.1
Vahlhaus, C.2
Lauck, G.3
Von Smekal, A.4
Reinke, M.5
Hofer, U.6
Block, W.7
-
11
-
-
0030931926
-
Effects of magnetic resonance imaging on cardiac pacemakers and electrodes
-
Achenbach S, Moshage W, Diem B, Bieberle T, Schibgilla V, Bachmann K,. Effects of magnetic resonance imaging on cardiac pacemakers and electrodes. Am Heart J 1997; 134: 467-473.
-
(1997)
Am Heart J
, vol.134
, pp. 467-473
-
-
Achenbach, S.1
Moshage, W.2
Diem, B.3
Bieberle, T.4
Schibgilla, V.5
Bachmann, K.6
-
12
-
-
14144252694
-
In vivo heating of pacemaker leads during magnetic resonance imaging
-
Luechinger R, Zeijlemaker VA, Pedersen EM, Mortensen P, Falk E, Duru F, Candinas R, et al. In vivo heating of pacemaker leads during magnetic resonance imaging. Eur Heart J 2005; 26: 376-383.
-
(2005)
Eur Heart J
, vol.26
, pp. 376-383
-
-
Luechinger, R.1
Zeijlemaker, V.A.2
Pedersen, E.M.3
Mortensen, P.4
Falk, E.5
Duru, F.6
Candinas, R.7
-
13
-
-
0035030124
-
Interference with cardiac pacemakers by MRI: Are there irreversible changes at 0.5 Tesla?
-
Vahlhaus C, Sommer T, Lewalter T, Schimpf R, Schumacher B, Jung W, Lüderitz B,. Interference with cardiac pacemakers by MRI: Are there irreversible changes at 0.5 Tesla? Pacing Clin Electrophysiol 2001; 24: 489-495.
-
(2001)
Pacing Clin Electrophysiol
, vol.24
, pp. 489-495
-
-
Vahlhaus, C.1
Sommer, T.2
Lewalter, T.3
Schimpf, R.4
Schumacher, B.5
Jung, W.6
Lüderitz, B.7
-
14
-
-
1842478179
-
Magnetic resonance imaging and cardiac pacemaker safety at 1.5 T
-
Martin ET, Coman JA, Shellock FG, Pulling CC, Fair R, Jenkins K,. Magnetic resonance imaging and cardiac pacemaker safety at 1.5 T. J Am Coll Cardiol 2004; 43: 1315-1324.
-
(2004)
J Am Coll Cardiol
, vol.43
, pp. 1315-1324
-
-
Martin, E.T.1
Coman, J.A.2
Shellock, F.G.3
Pulling, C.C.4
Fair, R.5
Jenkins, K.6
-
15
-
-
33748740922
-
Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable-cardioverter defibrillators at 1.5 tesla
-
Nazarian S,. Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable-cardioverter defibrillators at 1.5 tesla. Circulation 2006; 114: 1277-1284.
-
(2006)
Circulation
, vol.114
, pp. 1277-1284
-
-
Nazarian, S.1
-
16
-
-
3543116170
-
Modern pacemaker and implantable cardioverter/ defibrillator systems can be magnetic resonance imaging safe in vitro and in vivo assessment of safety and function at 1.5 T
-
Roguin A, Zviman MR,. Modern pacemaker and implantable cardioverter/ defibrillator systems can be magnetic resonance imaging safe in vitro and in vivo assessment of safety and function at 1.5 T. Circulation 2004; 110: 475-482.
-
(2004)
Circulation
, vol.110
, pp. 475-482
-
-
Roguin, A.1
Zviman, M.R.2
-
17
-
-
70449724740
-
Evaluation of cumulative effects of MR imaging on pacemaker systems at 1.5 Tesla
-
Naehle CP, Zeijlemaker V, Thomas D, Meyer C, Strach K, Fimmers R, Schild H, et al. Evaluation of cumulative effects of MR imaging on pacemaker systems at 1.5 Tesla. Pacing Clin Electrophysiol 2009; 32: 1526-1535.
-
(2009)
Pacing Clin Electrophysiol
, vol.32
, pp. 1526-1535
-
-
Naehle, C.P.1
Zeijlemaker, V.2
Thomas, D.3
Meyer, C.4
Strach, K.5
Fimmers, R.6
Schild, H.7
-
18
-
-
80053531595
-
A prospective evaluation of a protocol for magnetic resonance imaging of patients with implanted cardiac devices
-
Nazarian S, Hansford R, Roguin A, Goldsher D, Zviman MM, Lardo AC, Caffo BS, et al. A prospective evaluation of a protocol for magnetic resonance imaging of patients with implanted cardiac devices. Ann Intern Med 2011; 155: 415-424.
-
(2011)
Ann Intern Med
, vol.155
, pp. 415-424
-
-
Nazarian, S.1
Hansford, R.2
Roguin, A.3
Goldsher, D.4
Zviman, M.M.5
Lardo, A.C.6
Caffo, B.S.7
-
19
-
-
79958093042
-
Safety, feasibility, and diagnostic value of cardiac magnetic resonance imaging in patients with cardiac pacemakers and implantable cardioverters/ defibrillators at 1.5 T
-
Naehle CP, Kreuz J, Strach K, Schwab JO, Pingel S, Luechinger R, Fimmers R, et al. Safety, feasibility, and diagnostic value of cardiac magnetic resonance imaging in patients with cardiac pacemakers and implantable cardioverters/defibrillators at 1.5 T. Am Heart J 2011; 161: 1096-105.
-
(2011)
Am Heart J
, vol.161
, pp. 1096-1105
-
-
Naehle, C.P.1
Kreuz, J.2
Strach, K.3
Schwab, J.O.4
Pingel, S.5
Luechinger, R.6
Fimmers, R.7
-
20
-
-
1842530285
-
Can patients with implantable pacemakers safely undergo magnetic resonance imaging?
-
Gimbel RJ, Kanal E,. Can patients with implantable pacemakers safely undergo magnetic resonance imaging? J Am Coll Cardiol 2004; 43: 1325-1327.
-
(2004)
J Am Coll Cardiol
, vol.43
, pp. 1325-1327
-
-
Gimbel, R.J.1
Kanal, E.2
-
21
-
-
77952581688
-
Safety and efficacy of a new magnetic resonance imaging-compatible pacing system: Early results of a prospective comparison with conventional dual-chamber implant outcomes
-
Forleo GB, Santini L, Della Rocca DG, Romano V, Papavasileiou LP, Magliano G, et al. Safety and efficacy of a new magnetic resonance imaging-compatible pacing system: early results of a prospective comparison with conventional dual-chamber implant outcomes. Heart Rhythm 2010; 7: 750-754.
-
(2010)
Heart Rhythm
, vol.7
, pp. 750-754
-
-
Forleo, G.B.1
Santini, L.2
Della Rocca, D.G.3
Romano, V.4
Papavasileiou, L.P.5
Magliano, G.6
-
22
-
-
84855339792
-
Clinical routine implantation of a dual chamber pacemaker system designed for safe use with MRI: A single center, retrospective study on lead performance of Medtronic lead 5086MRI in comparison to Medtronic leads 4592-53 and 4092-58
-
Wollmann CG, Thudt K, Vock P, Globits S, Mayr H,. Clinical routine implantation of a dual chamber pacemaker system designed for safe use with MRI: A single center, retrospective study on lead performance of Medtronic lead 5086MRI in comparison to Medtronic leads 4592-53 and 4092-58. Herzschrittmacherther Elektrophysiol 2011; 22: 233-242.
-
(2011)
Herzschrittmacherther Elektrophysiol
, vol.22
, pp. 233-242
-
-
Wollmann, C.G.1
Thudt, K.2
Vock, P.3
Globits, S.4
Mayr, H.5
-
23
-
-
78650670809
-
Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment
-
Wilkoff BL, Bello D, Taborsky M, Vymazal J, Kanal E, Heuer H, Hecking K, et al. Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment. Heart Rhythm 2011; 8: 65-73.
-
(2011)
Heart Rhythm
, vol.8
, pp. 65-73
-
-
Wilkoff, B.L.1
Bello, D.2
Taborsky, M.3
Vymazal, J.4
Kanal, E.5
Heuer, H.6
Hecking, K.7
-
24
-
-
84874784278
-
-
Accessed July 1
-
Biotronik SE, & Co. Available at: http://www.biotronik.com Accessed July 1. 2012.
-
(2012)
-
-
Biotronik, S.E.1
-
25
-
-
84874780310
-
-
St. Jude Medical Accessed July 1. 2012
-
St. Jude Medical. Available at: http://www.sjm.com. Accessed July 1. 2012.
-
-
-
-
26
-
-
65749107941
-
Heart Rhythm Society Task Force on Lead Performance Policies and Guidelines; American College of Cardiology (ACC); American Heart Association (AHA). Recommendations from the Heart Rhythm Society Task Force on Lead Performance Policies and Guidelines: Developed in collaboration with the American College of Cardiology (ACC) and the American Heart Association (AHA)
-
Maisel WH, Hauser RG, Hammill SC, Hauser RG, Ellenbogen KA, Epstein AE, Hayes DL, et al. Heart Rhythm Society Task Force on Lead Performance Policies and Guidelines; American College of Cardiology (ACC); American Heart Association (AHA). Recommendations from the Heart Rhythm Society Task Force on Lead Performance Policies and Guidelines: Developed in collaboration with the American College of Cardiology (ACC) and the American Heart Association (AHA). Heart Rhythm 2009; 6: 869-885.
-
(2009)
Heart Rhythm
, vol.6
, pp. 869-885
-
-
Maisel, W.H.1
Hauser, R.G.2
Hammill, S.C.3
Hauser, R.G.4
Ellenbogen, K.A.5
Epstein, A.E.6
Hayes, D.L.7
-
27
-
-
55249119369
-
Magnetic resonance imaging of implantable cardiac rhythm devices at 3.0 Tesla
-
Gimbel JR,. Magnetic resonance imaging of implantable cardiac rhythm devices at 3.0 Tesla. Pacing Clin Electrophysiol 2008; 31: 795-801.
-
(2008)
Pacing Clin Electrophysiol
, vol.31
, pp. 795-801
-
-
Gimbel, J.R.1
-
29
-
-
79952017776
-
Guidelines and the growing service burden
-
Gimbel R,. Guidelines and the growing service burden. J Interv Card Electrophysiol 2010; 28: 83-85.
-
(2010)
J Interv Card Electrophysiol
, vol.28
, pp. 83-85
-
-
Gimbel, R.1
-
30
-
-
77955009233
-
The safety of MRI scanning of pacemakers and ICDs: What are the critical elements of safe scanning? Ask me again at 10 000
-
Gimbel R,. The safety of MRI scanning of pacemakers and ICDs: What are the critical elements of safe scanning? Ask me again at 10 000. Europace 2010; 12: 915-917.
-
(2010)
Europace
, vol.12
, pp. 915-917
-
-
Gimbel, R.1
-
31
-
-
0036800992
-
Interference in implanted cardiac devices, part II
-
Pinski SL, Trohman RG,. Interference in implanted cardiac devices, part II. Pacing Clin Electrophysiol 2002; 25: 1496-1509.
-
(2002)
Pacing Clin Electrophysiol
, vol.25
, pp. 1496-1509
-
-
Pinski, S.L.1
Trohman, R.G.2
-
32
-
-
84874782155
-
Medicare National Coverage Determinations Manual; Chapter 1, Part 4 (Sections 200-310.1)
-
07. Available at: http://www.cms.gov/Regulations-and-Guidance/Guidance/ Transmittals/downloads/R135NCD.pdf
-
Medicare National Coverage Determinations Manual; Chapter 1, Part 4 (Sections 200-310.1), Coverage Determinations: Rev 65, 02-23 -07. Available at: http://www.cms.gov/Regulations-and-Guidance/Guidance/Transmittals/downloads/ R135NCD.pdf
-
Coverage Determinations: Rev
, vol.65
, pp. 02-23
-
-
-
33
-
-
77952983907
-
Image-guided cardiac resynchronization
-
Schwartzman D, Schelbert E, Adelstein E, Gorcsan J, Soman P, Saba S,. Image-guided cardiac resynchronization. Europace 2010; 12: 877-880.
-
(2010)
Europace
, vol.12
, pp. 877-880
-
-
Schwartzman, D.1
Schelbert, E.2
Adelstein, E.3
Gorcsan, J.4
Soman, P.5
Saba, S.6
-
34
-
-
84871235545
-
-
Europace (doi: 10.1093/europace/eus230 [Epub ahead of print])
-
Sommer P, Grothoff M, Eitel C, Gaspar T, Piorkowski C, Gutberlet M, Hindrick G,. Feasibility of real-time magnetic resonance imaging-guided electrophysiology studies in humans. Europace 2012 (doi: 10.1093/europace/eus230 [Epub ahead of print]).
-
(2012)
Feasibility of Real-time Magnetic Resonance Imaging-guided Electrophysiology Studies in Humans
-
-
Sommer, P.1
Grothoff, M.2
Eitel, C.3
Gaspar, T.4
Piorkowski, C.5
Gutberlet, M.6
Hindrick, G.7
-
35
-
-
79955905010
-
Pacemakers and magnetic resonance imaging: Current status and survey in Switzerland
-
Weishaupt D, Bremerich J, Duru F, Hoppe H, Rizzo E, Votik P, Luechinger R,. Pacemakers and magnetic resonance imaging: Current status and survey in Switzerland. Swiss Med Wkly 2011 141: w13147.
-
(2011)
Swiss Med Wkly
, vol.141
-
-
Weishaupt, D.1
Bremerich, J.2
Duru, F.3
Hoppe, H.4
Rizzo, E.5
Votik, P.6
Luechinger, R.7
-
36
-
-
78049506986
-
Complication rates associated with pacemaker or implantable cardioverter-defibrillator generator replacements and upgrade procedures. Results from the REPLACE registry
-
Poole JE, Gleva MG, Mela T, Chung MK, Uslan DZ, Borge R, Gottipaty V, et al. Complication rates associated with pacemaker or implantable cardioverter-defibrillator generator replacements and upgrade procedures. Results from the REPLACE registry. Circulation 2010; 122: 1553-1561.
-
(2010)
Circulation
, vol.122
, pp. 1553-1561
-
-
Poole, J.E.1
Gleva, M.G.2
Mela, T.3
Chung, M.K.4
Uslan, D.Z.5
Borge, R.6
Gottipaty, V.7
|