메뉴 건너뛰기




Volumn 17, Issue 4, 2005, Pages 267-270

Tracheal width and left double-lumen tube size: A formula to estimate left-bronchial width

Author keywords

Airway, trachea, bronchus; Intubation, double lumen tube

Indexed keywords

ADULT; AGED; ARTICLE; BODY HEIGHT; BODY WEIGHT; BRONCHUS; CORRELATION ANALYSIS; ENDOTRACHEAL TUBE; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; MULTIVARIATE ANALYSIS; PREDICTION; PRIORITY JOURNAL; SEX ROLE; STATISTICAL ANALYSIS; STATISTICAL SIGNIFICANCE; THORAX RADIOGRAPHY; TRACHEA; UNIVERSITY HOSPITAL;

EID: 20444388672     PISSN: 09528180     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jclinane.2004.07.008     Document Type: Article
Times cited : (69)

References (14)
  • 1
    • 0021958079 scopus 로고
    • Malposition of left-sided endobronchial double-lumen tubes
    • J.B. Brodsky, M.S. Shulman, and J.B. Mark Malposition of left-sided endobronchial double-lumen tubes Anesthesiology 62 1985 667 669
    • (1985) Anesthesiology , vol.62 , pp. 667-669
    • Brodsky, J.B.1    Shulman, M.S.2    Mark, J.B.3
  • 2
    • 0029964337 scopus 로고    scopus 로고
    • The effective diameter and airflow resistance of the individual lumens of left polyvinyl chloride double-lumen endobronchial tubes
    • M.S. Hannallah, S.C. Miller, S.I. Kurzer, and M.C. Tefft The effective diameter and airflow resistance of the individual lumens of left polyvinyl chloride double-lumen endobronchial tubes Anesth Analg 82 1996 867 869
    • (1996) Anesth Analg , vol.82 , pp. 867-869
    • Hannallah, M.S.1    Miller, S.C.2    Kurzer, S.I.3    Tefft, M.C.4
  • 3
    • 0031924702 scopus 로고    scopus 로고
    • Flow resistances of disposable double-lumen, single-lumen, and Univent tubes
    • P.D. Slinger, and L. Lesiuk Flow resistances of disposable double-lumen, single-lumen, and Univent tubes J Cardiothorac Vasc Anesth 12 1998 142 144
    • (1998) J Cardiothorac Vasc Anesth , vol.12 , pp. 142-144
    • Slinger, P.D.1    Lesiuk, L.2
  • 5
    • 0028968178 scopus 로고
    • The relationship between left mainstem bronchial diameter and patient size
    • M.S. Hannallah, J.L. Benumof, and U.E. Ruttimann The relationship between left mainstem bronchial diameter and patient size J Cardiothorac Vasc Anesth 9 1995 119 121
    • (1995) J Cardiothorac Vasc Anesth , vol.9 , pp. 119-121
    • Hannallah, M.S.1    Benumof, J.L.2    Ruttimann, U.E.3
  • 6
    • 0027424342 scopus 로고
    • The resting volume and compliance characteristics of the bronchial cuff of left polyvinylchloride double-lumen endobronchial tubes
    • M.S. Hannallah, J.L. Benumof, L.C. Bachenheimer, and D.J. Mundt The resting volume and compliance characteristics of the bronchial cuff of left polyvinylchloride double-lumen endobronchial tubes Anesth Analg 77 1993 1222 1226
    • (1993) Anesth Analg , vol.77 , pp. 1222-1226
    • Hannallah, M.S.1    Benumof, J.L.2    Bachenheimer, L.C.3    Mundt, D.J.4
  • 7
    • 0037628935 scopus 로고    scopus 로고
    • Left double-lumen tubes: Clinical experience with 1,170 patients
    • J.B. Brodsky, and H.J. Lemmens Left double-lumen tubes: clinical experience with 1,170 patients J Cardiothorac Vasc Anesth 17 2003 289 298
    • (2003) J Cardiothorac Vasc Anesth , vol.17 , pp. 289-298
    • Brodsky, J.B.1    Lemmens, H.J.2
  • 9
    • 0031003952 scopus 로고    scopus 로고
    • Evaluation of an approach to choosing a left double-lumen tube size based on chest computed tomographic scan measurement of left mainstem bronchial diameter
    • M. Hannallah, J.L. Benumof, P.M. Silverman, L.C. Kelly, and D. Lea Evaluation of an approach to choosing a left double-lumen tube size based on chest computed tomographic scan measurement of left mainstem bronchial diameter J Cardiothorac Vasc Anesth 11 1997 168 171
    • (1997) J Cardiothorac Vasc Anesth , vol.11 , pp. 168-171
    • Hannallah, M.1    Benumof, J.L.2    Silverman, P.M.3    Kelly, L.C.4    Lea, D.5
  • 10
    • 0029285044 scopus 로고
    • Choosing the appropriate double-lumen tube: A glimmer of science comes to a dark art
    • P. Slinger Choosing the appropriate double-lumen tube: a glimmer of science comes to a dark art J Cardiothorac Vasc Anesth 9 1995 117 118
    • (1995) J Cardiothorac Vasc Anesth , vol.9 , pp. 117-118
    • Slinger, P.1
  • 11
    • 0038461038 scopus 로고    scopus 로고
    • A view of and through double-lumen tubes
    • P. Slinger A view of and through double-lumen tubes J Cardiothorac Vasc Anesth 17 2003 287 288
    • (2003) J Cardiothorac Vasc Anesth , vol.17 , pp. 287-288
    • Slinger, P.1
  • 12
    • 0001091748 scopus 로고
    • The dimensional interrelationships of the major components of the human tracheobronchial tree
    • J.E. Jesseph, and K.A. Merendino The dimensional interrelationships of the major components of the human tracheobronchial tree Surg Gynecol Obstet 105 1957 210 214
    • (1957) Surg Gynecol Obstet , vol.105 , pp. 210-214
    • Jesseph, J.E.1    Merendino, K.A.2
  • 13
    • 0035073646 scopus 로고    scopus 로고
    • The relationship between tracheal width and left bronchial width: Implications for left-sided double-lumen tube selection
    • J.B. Brodsky, K. Malott, M. Angst, B.G. Fitzmaurice, S.P. Kee, and L. Logan The relationship between tracheal width and left bronchial width: implications for left-sided double-lumen tube selection J Cardiothorac Vasc Anesth 15 2001 216 217
    • (2001) J Cardiothorac Vasc Anesth , vol.15 , pp. 216-217
    • Brodsky, J.B.1    Malott, K.2    Angst, M.3    Fitzmaurice, B.G.4    Kee, S.P.5    Logan, L.6
  • 14
    • 0029998807 scopus 로고    scopus 로고
    • Tracheal diameter predicts double-lumen tube size: A method for selecting left double-lumen tubes
    • J.B. Brodsky, A. Macario, and J.B. Mark Tracheal diameter predicts double-lumen tube size: a method for selecting left double-lumen tubes Anesth Analg 82 1996 861 864
    • (1996) Anesth Analg , vol.82 , pp. 861-864
    • Brodsky, J.B.1    MacArio, A.2    Mark, J.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.