메뉴 건너뛰기




Volumn 31, Issue 4, 2013, Pages 596-600

The importance of lag screw position for the stabilization of trochanteric fractures with a sliding hip screw: A subject-specific finite element study

Author keywords

cut out; osteosynthesis; tip apex distance; yield strain

Indexed keywords

AGED; ARTICLE; BIOMECHANICS; BONE MASS; BONE SCREW; COMPUTED TOMOGRAPHY SCANNER; FEMALE; FEMUR HEAD; FEMUR IMPLANT; FEMUR NECK; FEMUR SHAFT FRACTURE; FEMUR TROCHANTERIC FRACTURE; FINITE ELEMENT ANALYSIS; HUMAN; MOTOR PERFORMANCE; PREDICTOR VARIABLE; PRIORITY JOURNAL;

EID: 84874645368     PISSN: 07360266     EISSN: 1554527X     Source Type: Journal    
DOI: 10.1002/jor.22266     Document Type: Article
Times cited : (116)

References (29)
  • 1
    • 84921622711 scopus 로고    scopus 로고
    • Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults
    • Parker MJ, Handoll HH., 2010. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database Syst Rev CD000093.
    • (2010) Cochrane Database Syst Rev
    • Parker, M.J.1    Handoll, H.H.2
  • 2
    • 79952797372 scopus 로고    scopus 로고
    • Hip screw migration testing: First results for hip screws and helical blades utilizing a new oscillating test method
    • Born CT, Karich B, Bauer C, et al. 2011. Hip screw migration testing: first results for hip screws and helical blades utilizing a new oscillating test method. J Orthop Res 29: 760-766.
    • (2011) J Orthop Res , vol.29 , pp. 760-766
    • Born, C.T.1    Karich, B.2    Bauer, C.3
  • 3
    • 78549289900 scopus 로고    scopus 로고
    • Risk factors in cutout of sliding hip screw in intertrochanteric fractures: An evaluation of 937 patients
    • Hsueh KK, Fang CK, Chen CM, et al. 2010. Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients. Int Orthop 34: 1273-1276.
    • (2010) Int Orthop , vol.34 , pp. 1273-1276
    • Hsueh, K.K.1    Fang, C.K.2    Chen, C.M.3
  • 4
    • 4444241897 scopus 로고    scopus 로고
    • Prediction of fixation failure after sliding hip screw fixation
    • Pervez H, Parker MJ, Vowler S., 2004. Prediction of fixation failure after sliding hip screw fixation. Injury 35: 994-998.
    • (2004) Injury , vol.35 , pp. 994-998
    • Pervez, H.1    Parker, M.J.2    Vowler, S.3
  • 5
    • 34548567395 scopus 로고    scopus 로고
    • Subject-specific finite element models can accurately predict strain levels in long bones
    • Schileo E, Taddei F, Malandrino A, et al. 2007. Subject-specific finite element models can accurately predict strain levels in long bones. J Biomech 40: 2982-2989.
    • (2007) J Biomech , vol.40 , pp. 2982-2989
    • Schileo, E.1    Taddei, F.2    Malandrino, A.3
  • 6
    • 48349100917 scopus 로고    scopus 로고
    • An accurate estimation of bone density improves the accuracy of subject-specific finite element models
    • Schileo E, Dall'ara E, Taddei F, et al. 2008. An accurate estimation of bone density improves the accuracy of subject-specific finite element models. J Biomech 41: 2483-2491.
    • (2008) J Biomech , vol.41 , pp. 2483-2491
    • Schileo, E.1    Dall'Ara, E.2    Taddei, F.3
  • 7
    • 48349132341 scopus 로고    scopus 로고
    • An efficient approach to converting three-dimensional image data into highly accurate computational models
    • Young PG, Beresford-West TBH, Coward SRL, et al. 2008. An efficient approach to converting three-dimensional image data into highly accurate computational models. Philos Trans R Soc A 366: 3155-3173.
    • (2008) Philos Trans R Soc A , vol.366 , pp. 3155-3173
    • Young, P.G.1    Beresford-West, T.B.H.2    Coward, S.R.L.3
  • 8
    • 78049458315 scopus 로고    scopus 로고
    • A biomechanical evaluation of orthopaedic implants for hip fractures by finite element analysis and in-vitro tests
    • Eberle S, Gerber C, von Oldenburg G, et al. 2010. A biomechanical evaluation of orthopaedic implants for hip fractures by finite element analysis and in-vitro tests. Proc Inst Mech Eng H 224: 1141-1152.
    • (2010) Proc Inst Mech Eng H , vol.224 , pp. 1141-1152
    • Eberle, S.1    Gerber, C.2    Von Oldenburg, G.3
  • 9
    • 35748952794 scopus 로고    scopus 로고
    • The number of screws, bone quality, and friction coefficient affect acetabular cup stability
    • Hsu JT, Chang CH, Huang HL, et al. 2007. The number of screws, bone quality, and friction coefficient affect acetabular cup stability. Med Eng Phys 29: 1089-1095.
    • (2007) Med Eng Phys , vol.29 , pp. 1089-1095
    • Hsu, J.T.1    Chang, C.H.2    Huang, H.L.3
  • 10
    • 42049094688 scopus 로고    scopus 로고
    • Finite element analysis of a subtrochanteric fractured femur with dynamic hip screw, dynamic condylar screw, and proximal femur nail implants - A comparative study
    • Sowmianarayanan S, Chandrasekaran A, Kumar RK., 2008. Finite element analysis of a subtrochanteric fractured femur with dynamic hip screw, dynamic condylar screw, and proximal femur nail implants-a comparative study. Proc Inst Mech Eng H 222: 117-127.
    • (2008) Proc Inst Mech Eng H , vol.222 , pp. 117-127
    • Sowmianarayanan, S.1    Chandrasekaran, A.2    Kumar, R.K.3
  • 11
    • 0034986916 scopus 로고    scopus 로고
    • Musculo-skeletal loading conditions at the hip during walking and stair climbing
    • Heller MO, Bergmann G, Deuretzbacher G, et al. 2001. Musculo-skeletal loading conditions at the hip during walking and stair climbing. J Biomech 34: 883-893.
    • (2001) J Biomech , vol.34 , pp. 883-893
    • Heller, M.O.1    Bergmann, G.2    Deuretzbacher, G.3
  • 12
    • 67949112753 scopus 로고    scopus 로고
    • Type of hip fracture determines load share in intramedullary osteosynthesis
    • Eberle S, Gerber C, von Oldenburg G, et al. 2009. Type of hip fracture determines load share in intramedullary osteosynthesis. Clin Orthop Relat Res 467: 1972-1980.
    • (2009) Clin Orthop Relat Res , vol.467 , pp. 1972-1980
    • Eberle, S.1    Gerber, C.2    Von Oldenburg, G.3
  • 13
    • 0017763115 scopus 로고
    • Thickness and distribution of human femoral head articular cartilage. Changes with age
    • Armstrong CG, Gardner DL., 1977. Thickness and distribution of human femoral head articular cartilage. Changes with age. Ann Rheum Dis 36: 407-412.
    • (1977) Ann Rheum Dis , vol.36 , pp. 407-412
    • Armstrong, C.G.1    Gardner, D.L.2
  • 15
    • 79953061015 scopus 로고    scopus 로고
    • In vivo discrimination of hip fracture with quantitative computed tomography: Results from the prospective European Femur Fracture Study (EFFECT)
    • Bousson VD, Adams J, Engelke K, et al. 2011. In vivo discrimination of hip fracture with quantitative computed tomography: results from the prospective European Femur Fracture Study (EFFECT). J Bone Miner Res 26: 881-893.
    • (2011) J Bone Miner Res , vol.26 , pp. 881-893
    • Bousson, V.D.1    Adams, J.2    Engelke, K.3
  • 16
    • 0029012764 scopus 로고
    • The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip
    • Baumgaertner MR, Curtin SL, Lindskog DM, et al. 1995. The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am 77A: 1058-1064.
    • (1995) J Bone Joint Surg Am , vol.77 A , pp. 1058-1064
    • Baumgaertner, M.R.1    Curtin, S.L.2    Lindskog, D.M.3
  • 17
    • 69449088638 scopus 로고    scopus 로고
    • Heterogeneity of yield strain in low-density versus high-density human trabecular bone
    • Bevill G, Farhamand F, Keaveny TM., 2009. Heterogeneity of yield strain in low-density versus high-density human trabecular bone. J Biomech 42: 2165-2170.
    • (2009) J Biomech , vol.42 , pp. 2165-2170
    • Bevill, G.1    Farhamand, F.2    Keaveny, T.M.3
  • 18
    • 0032123274 scopus 로고    scopus 로고
    • Yield strain behavior of trabecular bone
    • Kopperdahl DL, Keaveny TM., 1998. Yield strain behavior of trabecular bone. J Biomech 31: 601-608.
    • (1998) J Biomech , vol.31 , pp. 601-608
    • Kopperdahl, D.L.1    Keaveny, T.M.2
  • 19
    • 0029858714 scopus 로고    scopus 로고
    • Biomechanical analysis of location of lag screw of a dynamic hip screw in treatment of unstable intertrochanteric fracture
    • Wu CC, Shih CH, Lee MY, Tai CL., 1996. Biomechanical analysis of location of lag screw of a dynamic hip screw in treatment of unstable intertrochanteric fracture. J Trauma 41: 699-702.
    • (1996) J Trauma , vol.41 , pp. 699-702
    • Wu, C.C.1    Shih, C.H.2    Lee, M.Y.3    Tai, C.L.4
  • 20
    • 61849155780 scopus 로고    scopus 로고
    • Finite element analysis of four different implants inserted in different positions to stabilize an idealized trochanteric femoral fracture
    • Helwig P, Faust G, Hindenlang U, et al. 2009. Finite element analysis of four different implants inserted in different positions to stabilize an idealized trochanteric femoral fracture. Injury 40: 288-295.
    • (2009) Injury , vol.40 , pp. 288-295
    • Helwig, P.1    Faust, G.2    Hindenlang, U.3
  • 21
    • 2542493936 scopus 로고    scopus 로고
    • Determination and significance of femoral neck anteversion
    • Cibulka MT., 2004. Determination and significance of femoral neck anteversion. Phys Ther 84: 550-558.
    • (2004) Phys Ther , vol.84 , pp. 550-558
    • Cibulka, M.T.1
  • 22
    • 80053332290 scopus 로고    scopus 로고
    • Functional and anatomic orientation of the femoral head
    • Wright D, Whyne C, Hardisty M, et al. 2011. Functional and anatomic orientation of the femoral head. Clin Orthop Relat Res 469: 2583-2589.
    • (2011) Clin Orthop Relat Res , vol.469 , pp. 2583-2589
    • Wright, D.1    Whyne, C.2    Hardisty, M.3
  • 23
    • 0035283247 scopus 로고    scopus 로고
    • Sex determination from the head of the femur of South African whites and blacks
    • Asala SA., 2001. Sex determination from the head of the femur of South African whites and blacks. Forensic Sci Int 117: 15-22.
    • (2001) Forensic Sci Int , vol.117 , pp. 15-22
    • Asala, S.A.1
  • 24
    • 50349097757 scopus 로고    scopus 로고
    • Difference in femoral head and neck material properties between osteoarthritis and osteoporosis
    • Sun SS, Ma HL, Liu CL, et al. 2008. Difference in femoral head and neck material properties between osteoarthritis and osteoporosis. Clin Biomech (Bristol, Avon) 23: S39-S47.
    • (2008) Clin Biomech (Bristol, Avon) , vol.23
    • Sun, S.S.1    Ma, H.L.2    Liu, C.L.3
  • 25
    • 77955951186 scopus 로고    scopus 로고
    • Tip-apex distance of intramedullary devices as a predictor of cut-out failure in the treatment of peritrochanteric elderly hip fractures
    • Geller JA, Saifi C, Morrison TA, et al. 2010. Tip-apex distance of intramedullary devices as a predictor of cut-out failure in the treatment of peritrochanteric elderly hip fractures. Int Orthop 34: 719-722.
    • (2010) Int Orthop , vol.34 , pp. 719-722
    • Geller, J.A.1    Saifi, C.2    Morrison, T.A.3
  • 26
    • 38349060664 scopus 로고    scopus 로고
    • Subject-specific finite element models implementing a maximum principal strain criterion are able to estimate failure risk and fracture location on human femurs tested in vitro
    • Schileo E, Taddei F, Cristofolini L, et al. 2008. Subject-specific finite element models implementing a maximum principal strain criterion are able to estimate failure risk and fracture location on human femurs tested in vitro. J Biomech 41: 356-367.
    • (2008) J Biomech , vol.41 , pp. 356-367
    • Schileo, E.1    Taddei, F.2    Cristofolini, L.3
  • 27
    • 33747751643 scopus 로고    scopus 로고
    • Tetrahedral versus hexahedral finite elements in numerical modelling of the proximal femur
    • Ramos A, Simoes JA., 2006. Tetrahedral versus hexahedral finite elements in numerical modelling of the proximal femur. Med Eng Phys 28: 916-924.
    • (2006) Med Eng Phys , vol.28 , pp. 916-924
    • Ramos, A.1    Simoes, J.A.2
  • 28
    • 15944383441 scopus 로고    scopus 로고
    • Determination of muscle loading at the hip joint for use in pre-clinical testing
    • Heller MO, Bergmann G, Kassi JP, et al. 2005. Determination of muscle loading at the hip joint for use in pre-clinical testing. J Biomech 38: 1155-1163.
    • (2005) J Biomech , vol.38 , pp. 1155-1163
    • Heller, M.O.1    Bergmann, G.2    Kassi, J.P.3
  • 29
    • 0034984126 scopus 로고    scopus 로고
    • Hip contact forces and gait patterns from routine activities
    • Bergmann G, Deuretzbacher G, Heller M, et al. 2001. Hip contact forces and gait patterns from routine activities. J Biomech 34: 859-871.
    • (2001) J Biomech , vol.34 , pp. 859-871
    • Bergmann, G.1    Deuretzbacher, G.2    Heller, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.