메뉴 건너뛰기




Volumn 7, Issue , 2013, Pages 417-422

Central corneal thickness and anterior chamber depth measurement by sirius® Scheimpfug tomography and ultrasound

Author keywords

Limits of agreement; Scheimpfug corneal tomography; Ultrasound biometry; Ultrasound pachymetry

Indexed keywords

ADULT; ANTERIOR EYE CHAMBER DEPTH; ARTICLE; BIOMETRY; BIOMICROSCOPY; CAMERA; CENTRAL CORNEAL THICKNESS; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; ECHOGRAPHY; FEMALE; HUMAN; HUMAN EXPERIMENT; IMAGE ANALYSIS; IMAGE PROCESSING; IMAGE QUALITY; MALE; MEDICAL DEVICE; NORMAL HUMAN; PACHYMETRY; SCHEIMPFLUG CORNEAL TOMOGRAPHY; TOMOGRAPHY; TOPOGRAPHY;

EID: 84874517706     PISSN: 11775467     EISSN: 11775483     Source Type: Journal    
DOI: 10.2147/OPTH.S35121     Document Type: Article
Times cited : (26)

References (22)
  • 2
    • 0033192282 scopus 로고    scopus 로고
    • Further information on the knowledge of topographical corneal thickness
    • Parafta M, Yebra-Pimentel E, Giraldez MJ, et al. Further information on the knowledge of topographical corneal thickness. Int Contact Lens Clin. 1999;26:128-137.
    • (1999) Int Contact Lens Clin , vol.26 , pp. 128-137
    • Parafta, M.1    Yebra-Pimentel, E.2    Giraldez, M.J.3
  • 3
    • 70349972238 scopus 로고    scopus 로고
    • Determination of corneal volume from anterior topography and topographic pachymetry: Application to healthy and keratoconic eyes
    • Cervino A, Gonzalez-Meijome JM, Ferrer-Blasco T, et al. Determination of corneal volume from anterior topography and topographic pachymetry: application to healthy and keratoconic eyes. Ophthalmic Physiol Opt. 2009;29:652-660.
    • (2009) Ophthalmic Physiol Opt , vol.29 , pp. 652-660
    • Cervino, A.1    Gonzalez-Meijome, J.M.2    Ferrer-Blasco, T.3
  • 4
    • 70350125378 scopus 로고    scopus 로고
    • Stromal thickness in the normal cornea: Three-dimensional display with Artemis very high frequency digital ultrasound
    • Reinstein DZ, Archer TJ, Gobbe M, et al. Stromal thickness in the normal cornea: three-dimensional display with Artemis very high frequency digital ultrasound. J Refract Surg. 2009;25:776-786.
    • (2009) J Refract Surg , vol.25 , pp. 776-786
    • Reinstein, D.Z.1    Archer, T.J.2    Gobbe, M.3
  • 5
    • 0030967592 scopus 로고    scopus 로고
    • Ultrasound biomicroscopic corneal thickness measurement for corneal thickness mapping
    • Wada I. Ultrasound biomicroscopic corneal thickness measurement for corneal thickness mapping. Jpn J Ophthalmol. 1997;41:12-18.
    • (1997) Jpn J Ophthalmol , vol.41 , pp. 12-18
    • Wada, I.1
  • 6
    • 0037255230 scopus 로고    scopus 로고
    • Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry
    • Gonzalez-Meijome JM, Cervino A, Yebra-Pimentel E, Parafta MA. Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry. J Cataract Refract Surg. 2003;29:125-132.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 125-132
    • Gonzalez-Meijome, J.M.1    Cervino, A.2    Yebra-Pimentel, E.3    Parafta, M.A.4
  • 7
    • 77949389504 scopus 로고    scopus 로고
    • Central corneal thickness, anterior chamber depth, and pupil diameter measurements using Visante OCT, Orbscan, and Pentacam
    • Yazici AT, Bozkurt E, Alagoz C, et al. Central corneal thickness, anterior chamber depth, and pupil diameter measurements using Visante OCT, Orbscan, and Pentacam. J Refract Surg. 2010;26:127-133.
    • (2010) J Refract Surg , vol.26 , pp. 127-133
    • Yazici, A.T.1    Bozkurt, E.2    Alagoz, C.3
  • 9
    • 27644542761 scopus 로고    scopus 로고
    • Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound
    • Lackner B, Schmidinger G, Pieh S, et al. Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound. Optom Vis Sci. 2005;82:892-899.
    • (2005) Optom Vis Sci , vol.82 , pp. 892-899
    • Lackner, B.1    Schmidinger, G.2    Pieh, S.3
  • 10
    • 34250648821 scopus 로고    scopus 로고
    • Central corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopia
    • Ho T, Cheng AC, Rao SK, et al. Central corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopia. J Cataract Refract Surg. 2007;33:1177-1182.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 1177-1182
    • Ho, T.1    Cheng, A.C.2    Rao, S.K.3
  • 12
    • 78449247507 scopus 로고    scopus 로고
    • Pupil size, white-to-white corneal diameter, and anterior chamber depth in patients with myopia
    • Alfonso JF, Ferrer-Blasco T, Gonzalez-Meijome JM, et al. Pupil size, white-to-white corneal diameter, and anterior chamber depth in patients with myopia. J Refract Surg. 2010;26:891-898.
    • (2010) J Refract Surg , vol.26 , pp. 891-898
    • Alfonso, J.F.1    Ferrer-Blasco, T.2    Gonzalez-Meijome, J.M.3
  • 13
    • 27644517844 scopus 로고    scopus 로고
    • Anterior chamber depth measurement with a-scan ultrasonography, Orbscan II, and IOLMaster
    • Hashemi H, Yazdani K, Mehravaran S, Fotouhi A. Anterior chamber depth measurement with a-scan ultrasonography, Orbscan II, and IOLMaster. Optom Vis Sci. 2005;82:900-904.
    • (2005) Optom Vis Sci , vol.82 , pp. 900-904
    • Hashemi, H.1    Yazdani, K.2    Mehravaran, S.3    Fotouhi, A.4
  • 14
    • 80051861463 scopus 로고    scopus 로고
    • Repeatability of automatic measurements by a new Scheimpfug camera combined with Placido topography
    • Savini G, Barboni P, Carbonelli M, Hoffer KJ. Repeatability of automatic measurements by a new Scheimpfug camera combined with Placido topography. J Cataract Refract Surg. 2011;37:1809-1816.
    • (2011) J Cataract Refract Surg , vol.37 , pp. 1809-1816
    • Savini, G.1    Barboni, P.2    Carbonelli, M.3    Hoffer, K.J.4
  • 15
    • 80051875041 scopus 로고    scopus 로고
    • Comparison of anterior segment measurements by 3 Scheimpflug tomographers and 1 Placido corneal topographer
    • Savini G, Carbonelli M, Sbreglia A, et al. Comparison of anterior segment measurements by 3 Scheimpflug tomographers and 1 Placido corneal topographer. J Cataract Refract Surg. 2011;37: 1679-1685.
    • (2011) J Cataract Refract Surg , vol.37 , pp. 1679-1685
    • Savini, G.1    Carbonelli, M.2    Sbreglia, A.3
  • 16
    • 78751497805 scopus 로고    scopus 로고
    • Pachymetric measurements with a new Scheimpfug photography-based system: Intraobserver repeatability and agreement with optical coherence tomography pachymetry
    • Milla M, Pinero D P, Amparo F, Alio JL. Pachymetric measurements with a new Scheimpfug photography-based system: intraobserver repeatability and agreement with optical coherence tomography pachymetry. J Cataract Refract Surg. 2011;37:310-316.
    • (2011) J Cataract Refract Surg , vol.37 , pp. 310-316
    • Milla, M.1    Pinero, D.P.2    Amparo, F.3    Alio, J.L.4
  • 17
    • 0037378859 scopus 로고    scopus 로고
    • Diurnal variation of corneal sensitivity and thickness
    • Du TR, Vega JA, Fonn D, Simpson T. Diurnal variation of corneal sensitivity and thickness. Cornea. 2003;22:205-209.
    • (2003) Cornea , vol.22 , pp. 205-209
    • Du, T.R.1    Vega, J.A.2    Fonn, D.3    Simpson, T.4
  • 18
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1: 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 19
    • 78049307441 scopus 로고    scopus 로고
    • Accuracy of RTVue optical coherence tomography, Pentacam, and ultrasonic pachymetry for the measurement of central corneal thickness
    • Nam SM, Im CY, Lee HK, Kim EK, Kim TI, Seo KY. Accuracy of RTVue optical coherence tomography, Pentacam, and ultrasonic pachymetry for the measurement of central corneal thickness. Ophthalmology. 2010;117:2096-2103.
    • (2010) Ophthalmology , vol.117 , pp. 2096-2103
    • Nam, S.M.1    Im, C.Y.2    Lee, H.K.3    Kim, E.K.4    Kim, T.I.5    Seo, K.Y.6
  • 20
    • 76149100636 scopus 로고    scopus 로고
    • Changes in corneal thickness, curvature, and anterior chamber depth during the menstrual cycle
    • Hashemi H, Mehravaran S, Rezvan F. Changes in corneal thickness, curvature, and anterior chamber depth during the menstrual cycle. Can J Ophthalmol. 2010;45:67-70.
    • (2010) Can J Ophthalmol , vol.45 , pp. 67-70
    • Hashemi, H.1    Mehravaran, S.2    Rezvan, F.3
  • 21
    • 79955072484 scopus 로고    scopus 로고
    • Reliability of the corneal thickness measurements with the Pentacam HR imaging system and ultrasound pachymetry
    • Modis L, Szalai E, Németh G, Berta A. Reliability of the corneal thickness measurements with the Pentacam HR imaging system and ultrasound pachymetry. Cornea. 2011;30:561-566.
    • (2011) Cornea , vol.30 , pp. 561-566
    • Modis, L.1    Szalai, E.2    Németh, G.3    Berta, A.4
  • 22
    • 33746040471 scopus 로고    scopus 로고
    • Anterior chamber depth measurements in phakic and pseudophakic eyes: Pentacam versus ultrasound device
    • Nemeth G, Vajas A, Kolozsvari B, Berta A, Modis L. Anterior chamber depth measurements in phakic and pseudophakic eyes: Pentacam versus ultrasound device. J Cataract Refract Surg. 2006;32: 1331-1335.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 1331-1335
    • Nemeth, G.1    Vajas, A.2    Kolozsvari, B.3    Berta, A.4    Modis, L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.