메뉴 건너뛰기




Volumn 33, Issue 7, 2007, Pages 1177-1182

Central corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopia

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CORNEA THICKNESS; HONG KONG; HUMAN; INTERMETHOD COMPARISON; KERATOMILEUSIS; MAJOR CLINICAL STUDY; MYOPIA; PRIORITY JOURNAL; ULTRASOUND;

EID: 34250648821     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2007.03.028     Document Type: Article
Times cited : (94)

References (17)
  • 1
    • 0347662615 scopus 로고    scopus 로고
    • Ectasia after laser in situ keratomileusis
    • Binder P.S. Ectasia after laser in situ keratomileusis. J Cataract Refract Surg 29 (2003) 2419-2429
    • (2003) J Cataract Refract Surg , vol.29 , pp. 2419-2429
    • Binder, P.S.1
  • 2
    • 0032930812 scopus 로고    scopus 로고
    • Corneal indentation during ultrasonic pachometry
    • Solomon O.D. Corneal indentation during ultrasonic pachometry. Cornea 18 (1999) 214-215
    • (1999) Cornea , vol.18 , pp. 214-215
    • Solomon, O.D.1
  • 3
    • 33645945900 scopus 로고    scopus 로고
    • Pachymetry assessment with Orbscan II in postoperative patients with myopic LASIK
    • Cheng A.C.K., Rao S.K., Tang E., and Lam D.S.C. Pachymetry assessment with Orbscan II in postoperative patients with myopic LASIK. J Refract Surg 22 (2006) 363-366
    • (2006) J Refract Surg , vol.22 , pp. 363-366
    • Cheng, A.C.K.1    Rao, S.K.2    Tang, E.3    Lam, D.S.C.4
  • 4
    • 0037373268 scopus 로고    scopus 로고
    • Reliability of pachymetric measurements using Orbscan after excimer refractive surgery
    • Prisant O., Calderon N., Chastang P., et al. Reliability of pachymetric measurements using Orbscan after excimer refractive surgery. Ophthalmology 110 (2003) 511-515
    • (2003) Ophthalmology , vol.110 , pp. 511-515
    • Prisant, O.1    Calderon, N.2    Chastang, P.3
  • 5
    • 0030732713 scopus 로고    scopus 로고
    • Corneal thickness measurements with the Orbscan Topography System and ultrasonic pachymetry
    • Yaylali V., Kaufman S.C., and Thompson H.W. Corneal thickness measurements with the Orbscan Topography System and ultrasonic pachymetry. J Cataract Refract Surg 23 (1997) 1345-1350
    • (1997) J Cataract Refract Surg , vol.23 , pp. 1345-1350
    • Yaylali, V.1    Kaufman, S.C.2    Thompson, H.W.3
  • 6
    • 0030477331 scopus 로고    scopus 로고
    • Diurnal variations in human corneal thickness
    • erratum 1997; 81:175
    • Harper C.L., Boulton M.E., Bennett D., et al. Diurnal variations in human corneal thickness. Br J Ophthalmol 80 (1996) 1068-1072 erratum 1997; 81:175
    • (1996) Br J Ophthalmol , vol.80 , pp. 1068-1072
    • Harper, C.L.1    Boulton, M.E.2    Bennett, D.3
  • 7
    • 0021343454 scopus 로고
    • Investigations on lens transparency and its disturbances by microdensitometric analyses of Scheimpflug photographs
    • Hockwin O., Lerman S., and Ohrloff C. Investigations on lens transparency and its disturbances by microdensitometric analyses of Scheimpflug photographs. Curr Eye Res 3 (1984) 15-22
    • (1984) Curr Eye Res , vol.3 , pp. 15-22
    • Hockwin, O.1    Lerman, S.2    Ohrloff, C.3
  • 8
    • 0026454347 scopus 로고
    • Comparison of the Nidek EAS 1000 system and the Topcon SL-45 in clinical application
    • Wegener A., Hockwin O., Laser H., and Strack C. Comparison of the Nidek EAS 1000 system and the Topcon SL-45 in clinical application. Ophthalmic Res 24 suppl 1 (1992) 55-62
    • (1992) Ophthalmic Res , vol.24 , Issue.SUPPL. 1 , pp. 55-62
    • Wegener, A.1    Hockwin, O.2    Laser, H.3    Strack, C.4
  • 9
    • 0036963538 scopus 로고    scopus 로고
    • The effect of corneal thickness and corneal curvature on pneumatonometer measurements
    • Morgan A.J., Harper J., Hosking S.L., and Gilmartin B. The effect of corneal thickness and corneal curvature on pneumatonometer measurements. Curr Eye Res 25 (2002) 107-112
    • (2002) Curr Eye Res , vol.25 , pp. 107-112
    • Morgan, A.J.1    Harper, J.2    Hosking, S.L.3    Gilmartin, B.4
  • 10
    • 34748896756 scopus 로고    scopus 로고
    • Li EY, Mohamed S, Leung CK, et al. Agreement among 3 methods to measure corneal thickness: ultrasound pachymetry, Orbscan II and Visante anterior segment optical coherence tomography. In press, Ophthalmology 2007
  • 11
    • 27644542761 scopus 로고    scopus 로고
    • Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound
    • Lackner B., Schmidinger G., Pieh S., et al. Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound. Optom Vis Sci 82 (2005) 892-899
    • (2005) Optom Vis Sci , vol.82 , pp. 892-899
    • Lackner, B.1    Schmidinger, G.2    Pieh, S.3
  • 12
    • 27144479245 scopus 로고    scopus 로고
    • Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry
    • Barkana Y., Gerber Y., Elbaz U., et al. Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry. J Cataract Refract Surg 31 (2005) 1729-1735
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1729-1735
    • Barkana, Y.1    Gerber, Y.2    Elbaz, U.3
  • 13
    • 29544440497 scopus 로고    scopus 로고
    • Comparison of three methods of measuring corneal thickness and anterior chamber depth
    • Buehl W., Stojanac D., Sacu S., et al. Comparison of three methods of measuring corneal thickness and anterior chamber depth. Am J Ophthalmol 141 (2006) 7-12
    • (2006) Am J Ophthalmol , vol.141 , pp. 7-12
    • Buehl, W.1    Stojanac, D.2    Sacu, S.3
  • 14
    • 19344369632 scopus 로고    scopus 로고
    • Assessment of central corneal thickness using optical coherence tomography
    • Fishman G.R., Pons M.E., Seedor J.A., et al. Assessment of central corneal thickness using optical coherence tomography. J Cataract Refract Surg 31 (2005) 707-711
    • (2005) J Cataract Refract Surg , vol.31 , pp. 707-711
    • Fishman, G.R.1    Pons, M.E.2    Seedor, J.A.3
  • 15
    • 0033759092 scopus 로고    scopus 로고
    • The repeatability of corneal thickness measures
    • Marsich M.M., and Bullimore M.A. The repeatability of corneal thickness measures. Cornea 19 (2000) 792-795
    • (2000) Cornea , vol.19 , pp. 792-795
    • Marsich, M.M.1    Bullimore, M.A.2
  • 16
    • 0042201932 scopus 로고    scopus 로고
    • Corneal thickness measurements: scanning-slit corneal topography and noncontact specular microscopy versus ultrasonic pachymetry
    • Suzuki S., Oshika T., Oki K., et al. Corneal thickness measurements: scanning-slit corneal topography and noncontact specular microscopy versus ultrasonic pachymetry. J Cataract Refract Surg 29 (2003) 1313-1318
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1313-1318
    • Suzuki, S.1    Oshika, T.2    Oki, K.3
  • 17
    • 33745042431 scopus 로고    scopus 로고
    • The effects of eye drops on corneal thickness in adult myopia
    • Gao L., Fan H., Cheng A.C.K., et al. The effects of eye drops on corneal thickness in adult myopia. Cornea 25 (2006) 404-407
    • (2006) Cornea , vol.25 , pp. 404-407
    • Gao, L.1    Fan, H.2    Cheng, A.C.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.