Comparison of endothelial cell count using confocal and contact specular microscopy
-
DOI 10.1159/000068562
-
Klais CM, Bühren J, Kohnen T. Comparison of endothelial cell count using confocal and contact specular microscopy. Ophthalmologica. 2003; 217:99-103. (Pubitemid 36237703)
-
(2003)
Ophthalmologica
, vol.217
, Issue.2
, pp. 99-103
-
-
Klais, C.M.C.1
Buhren, J.2
Kohnen, T.3
-
2
-
-
0033822579
-
Specular microscopy confocal microscopy and ultrasound biomicroscopy diagnostic tools of the past quarter century
-
Cavanagh HD, El-Agha MS, Petroll WM, et al. Specular microscopy, confocal microscopy, and ultrasound biomicroscopy diagnostic tools of the past quarter century. Cornea. 2000;19:712-722.
-
(2000)
Cornea
, vol.19
, pp. 712-722
-
-
Cavanagh, H.D.1
El-Agha, M.S.2
Petroll, W.M.3
-
3
-
-
2942623857
-
Corneal thickness measurement by confocal microscopy, ultrasound, and scanning slit methods
-
DOI 10.1016/j.ajo.2004.01.049, PII S0002939404000935
-
McLaren JW, Nau CB, Erie JC, et al. Corneal thickness measurement by confocal microscopy, ultrasound, and scanning slit methods. Am J Ophthalmol. 2004;137:1011-1020. (Pubitemid 38759348)
-
(2004)
American Journal of Ophthalmology
, vol.137
, Issue.6
, pp. 1011-1020
-
-
McLaren, J.W.1
Nau, C.B.2
Erie, J.C.3
Bourne, W.M.4
-
4
-
-
0038650775
-
Comparison of central corneal thickness measurements by specular microscopy, ultrasound pachymetry, and ultrasound biomicroscopy
-
DOI 10.1016/S0886-3350(02)01921-1
-
Tam ES, Rootman DS. Comparison of central corneal thickness measurements by specular microscopy, ultrasound pachymetry, and ultrasound biomicroscopy. J Cataract Refract Surg. 2003;29:1179-1184. (Pubitemid 36759112)
-
(2003)
Journal of Cataract and Refractive Surgery
, vol.29
, Issue.6
, pp. 1179-1184
-
-
Tam, E.S.1
Rootman, D.S.2
-
5
-
-
29544440497
-
Comparison of three methods of measuring corneal thickness and anterior chamber depth
-
Buehl W, Stojanac D, Sacu S, et al. Comparison of three methods of measuring corneal thickness and anterior chamber depth. Am J Ophthalmol. 2006;141:7-12.
-
(2006)
Am J Ophthalmol
, vol.141
, pp. 7-12
-
-
Buehl, W.1
Stojanac, D.2
Sacu, S.3
-
6
-
-
0042201932
-
Corneal thickness measurements: Scanning-slit corneal topography and noncontact specular microscopy versus ultrasonic pachymetry
-
DOI 10.1016/S0886-3350(03)00123-8
-
Suzuki S, Oshika T, Oki K, et al. Corneal thickness measurements: scanning-slit corneal topography and noncontact specular microscopy versus ultrasonic pachymetry. J Cataract Refract Surg. 2003;29: 1313-1318. (Pubitemid 36939150)
-
(2003)
Journal of Cataract and Refractive Surgery
, vol.29
, Issue.7
, pp. 1313-1318
-
-
Suzuki, S.1
Oshika, T.2
Oki, K.3
Sakabe, I.4
Iwase, A.5
Amano, S.6
Araie, M.7
-
7
-
-
27644542761
-
Repeatability and reproducibility of central corneal thickness measurement with pentacam, orbscan, and ultrasound
-
DOI 10.1097/01.opx.0000180817.46312.0a
-
Lackner B, Schmidinger G, Pieh S, et al. Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound. Optom Vis Sci. 2005;82:892-899. (Pubitemid 41566871)
-
(2005)
Optometry and Vision Science
, vol.82
, Issue.10
, pp. 892-899
-
-
Lackner, B.1
Schmidinger, G.2
Pieh, S.3
Funovics, M.A.4
Skorpik, C.5
-
8
-
-
27144479245
-
Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry
-
DOI 10.1016/j.jcrs.2005.03.058, PII S088633500500430X
-
Barkana Y, Gerber Y, Elbaz U, et al. Central corneal thickness measurement with the Pentacam Scheimpflug system, optical lowcoherence reflectometry pachymeter, and ultrasound pachymetry. J Cataract Refract Surg. 2005;31:1729-1735. (Pubitemid 41503429)
-
(2005)
Journal of Cataract and Refractive Surgery
, vol.31
, Issue.9
, pp. 1729-1735
-
-
Barkana, Y.1
Gerber, Y.2
Elbaz, U.3
Schwartz, S.4
Ken-Dror, G.5
Avni, I.6
Zadok, D.7
-
9
-
-
67651083511
-
Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation
-
Doors M, Cruysberg LP, Berendschot TT, et al. Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation. Graefes Arch Clin Exp Ophthalmol. 2009;247:1139-1146.
-
(2009)
Graefes Arch Clin Exp Ophthalmol
, vol.247
, pp. 1139-1146
-
-
Doors, M.1
Cruysberg, L.P.2
Berendschot, T.T.3
-
10
-
-
65349131841
-
Anterior ocular biometry using 3- dimensional optical coherence tomography
-
Fukuda S, Kawana K, Yasuno Y, et al. Anterior ocular biometry using 3- dimensional optical coherence tomography. Ophthalmology. 2009;116: 882-889.
-
(2009)
Ophthalmology
, vol.116
, pp. 882-889
-
-
Fukuda, S.1
Kawana, K.2
Yasuno, Y.3
-
11
-
-
67249126267
-
Central and peripheral corneal thickness measured with optical coherence tomography, Scheimpflug imaging, and ultrasound pachymetry in normal, keratoconus-suspect, and post-laser in situ keratomileusis eyes
-
Prospero Ponce CM, Rocha KM, Smith SD, et al. Central and peripheral corneal thickness measured with optical coherence tomography, Scheimpflug imaging, and ultrasound pachymetry in normal, keratoconus-suspect, and post-laser in situ keratomileusis eyes. J Cataract Refract Surg. 2009; 35:1055-1062.
-
(2009)
J Cataract Refract Surg
, vol.35
, pp. 1055-1062
-
-
Prospero Ponce, C.M.1
Rocha, K.M.2
Smith, S.D.3
-
12
-
-
2342457162
-
Central corneal thickness measurements with partial coherence interferometry, ultrasound, and the Orbscan system
-
DOI 10.1016/j.ophtha.2003.09.027, PII S0161642003017469
-
Rainer G, Findl O, Petternel V, et al. Central corneal thickness measurements with partial coherence interferometry, ultrasound, and the Orbscan system. Ophthalmology. 2004;111:875-879. (Pubitemid 38586678)
-
(2004)
Ophthalmology
, vol.111
, Issue.5
, pp. 875-879
-
-
Rainer, G.1
Findl, O.2
Petternel, V.3
Kiss, B.4
Drexler, W.5
Skorpik, C.6
Georgopoulos, M.7
Schmetterer, L.8
-
13
-
-
0037378859
-
Diurnal variation of corneal sensitivity and thickness
-
DOI 10.1097/00003226-200304000-00004
-
du Toit R, Vega JA, Fonn D, et al. Diurnal variation of corneal sensitivity and thickness. Cornea. 2003;22:205-209. (Pubitemid 36359154)
-
(2003)
Cornea
, vol.22
, Issue.3
, pp. 205-209
-
-
Du Toit, R.1
Vega, J.A.2
Fonn, D.3
Simpson, T.4
-
14
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
PII S0140673686908378
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1: 307-310. (Pubitemid 16134762)
-
(1986)
Lancet
, vol.1
, Issue.8476
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
15
-
-
0032884749
-
Measuring agreement in method comparison studies
-
DOI 10.1191/096228099673819272
-
Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8:135-160. (Pubitemid 29425900)
-
(1999)
Statistical Methods in Medical Research
, vol.8
, Issue.2
, pp. 135-160
-
-
Bland, J.M.1
Altman, D.G.2
-
16
-
-
48249153186
-
Intraclass correlations: Uses in assessing rater reliability
-
Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 1979;86:420-428.
-
(1979)
Psychol Bull
, vol.86
, pp. 420-428
-
-
Shrout, P.E.1
Fleiss, J.L.2
-
17
-
-
0030596840
-
Measurement error
-
Bland JM, Altman DG. Measurement error. BMJ. 1996;313:744.
-
(1996)
BMJ
, vol.313
, pp. 744
-
-
Bland, J.M.1
Altman, D.G.2
-
18
-
-
33646906826
-
Comparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography
-
DOI 10.1016/j.ophtha.2006.01.063, PII S0161642006002806
-
Amano S, Honda N, Amano Y, et al. Comparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography. Ophthalmology. 2006; 113:937-941. (Pubitemid 43795239)
-
(2006)
Ophthalmology
, vol.113
, Issue.6
, pp. 937-941
-
-
Amano, S.1
Honda, N.2
Amano, Y.3
Yamagami, S.4
Miyai, T.5
Samejima, T.6
Ogata, M.7
Miyata, K.8
-
19
-
-
0030732713
-
Corneal thickness measurements with the Orbscan Topography System and ultrasonic pachymetry
-
Yaylali V, Kaufman SC, Thompson HW. Corneal thickness measurements with the Orbscan topography system and ultrasonic pachymetry. J Cataract Refract Surg. 1997;23:1345-1350. (Pubitemid 27524541)
-
(1997)
Journal of Cataract and Refractive Surgery
, vol.23
, Issue.9
, pp. 1345-1350
-
-
Yaylali, V.1
Kaufman, S.C.2
Thompson, H.W.3
-
20
-
-
0033051656
-
Corneal thickness is reduced in dry eye
-
Liu Z, Pflugfelder SC. Corneal thickness is reduced in dry eye. Cornea. 1999;18:403-407. (Pubitemid 29294061)
-
(1999)
Cornea
, vol.18
, Issue.4
, pp. 403-407
-
-
Liu, Z.1
Pflugfelder, S.C.2
-
21
-
-
0032767869
-
Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography system
-
Liu Z, Huang AJ, Pflugfelder SC. Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography system. Br J Ophthalmol. 1999;83:774-778. (Pubitemid 29324786)
-
(1999)
British Journal of Ophthalmology
, vol.83
, Issue.7
, pp. 774-778
-
-
Liu, Z.1
Huang, A.J.2
Pflugfelder, S.C.3
-
22
-
-
0033759092
-
The repeatability of corneal thickness measures
-
Marsich MW, Bullimore MA. The repeatability of corneal thickness measures. Cornea. 2000;19:792-795.
-
(2000)
Cornea
, vol.19
, pp. 792-795
-
-
Marsich, M.W.1
Bullimore, M.A.2
-
23
-
-
0035737828
-
Scanning-slit and specular microscopic pachymetry in comparison with ultrasonic determination of corneal thickness
-
DOI 10.1097/00003226-200110000-00008
-
Módis L Jr, Langenbucher A, Seitz B. Scanning-slit and specular microscopic pachymetry in comparison with ultrasonic determination of corneal thickness. Cornea. 2001;20:711-714. (Pubitemid 34506468)
-
(2001)
Cornea
, vol.20
, Issue.7
, pp. 711-714
-
-
Modis Jr., L.1
Langenbucher, A.2
Seitz, B.3
-
24
-
-
34548748620
-
Central corneal thickness measurement with Pentacam, Orbscan II, and ultrasound devices before and after laser refractive surgery for myopia
-
DOI 10.1016/j.jcrs.2007.05.040, PII S0886335007011868
-
Hashemi H, Mehravaran S. Central corneal thickness measurement with Pentacam, Orbscan II, and ultrasound devices before and after laser refractive surgery for myopia. J Cataract Refract Surg. 2007;33: 1701-1707. (Pubitemid 47432834)
-
(2007)
Journal of Cataract and Refractive Surgery
, vol.33
, Issue.10
, pp. 1701-1707
-
-
Hashemi, H.1
Mehravaran, S.2
-
25
-
-
35348960981
-
Reproducibility and repeatability of central corneal thickness measurement in keratoconus using the rotating Scheimpflug camera and ultrasound pachymetry
-
de Sanctis U, Missolungi A, Mutani B, et al. Reproducibility and repeatability of central corneal thickness measurement in keratoconus using the rotating Scheimpflug camera and ultrasound pachymetry. Am J Ophthalmol. 2007;144:712-718.
-
(2007)
Am J Ophthalmol
, vol.144
, pp. 712-718
-
-
De Sanctis, U.1
Missolungi, A.2
Mutani, B.3
-
26
-
-
34250648821
-
Central corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopia
-
DOI 10.1016/j.jcrs.2007.03.028, PII S0886335007005834
-
Ho T, Cheng AC, Rao SK, et al. Central corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopia. J Cataract Refract Surg. 2007;33: 1177-1182. (Pubitemid 46936129)
-
(2007)
Journal of Cataract and Refractive Surgery
, vol.33
, Issue.7
, pp. 1177-1182
-
-
Ho, T.1
Cheng, A.C.K.2
Rao, S.K.3
Lau, S.4
Leung, C.K.S.5
Lam, D.S.C.6
-
27
-
-
28044436542
-
Agreement and repeatability of central thickness measurement in normal corneas using ultrasound pachymetry and the OCULUS Pentacam
-
DOI 10.1097/01.ico.0000157422.01146.e9
-
O'Donnell C, Maldonado-Codina C. Agreement and repeatability of central thickness measurement in normal corneas using ultrasound pachymetry and the OCULUS Pentacam. Cornea. 2005; 24:920-924. (Pubitemid 41688522)
-
(2005)
Cornea
, vol.24
, Issue.8
, pp. 920-924
-
-
O'Donnell, C.1
Maldonado-Codina, C.2
-
28
-
-
0035161383
-
Comparison of corneal thickness measurements using ultrasound and Orbscan slit-scanning topography in normal and post-LASIK eyes
-
DOI 10.1016/S0886-3350(01)01089-6, PII S0886335001010896
-
Chakrabarti HS, Craig JP, Brahma A, et al. Comparison of corneal thickness measurements using ultrasound and Orbscan slit-scanning topography in normal and post-LASIK eyes. J Cataract Refract Surg. 2001;27:1823-1828. (Pubitemid 33055554)
-
(2001)
Journal of Cataract and Refractive Surgery
, vol.27
, Issue.11
, pp. 1823-1828
-
-
Chakrabarti, H.S.1
Craig, J.P.2
Brahma, A.3
Malik, T.Y.4
McGhee, C.N.J.5
-
29
-
-
1442329172
-
A comparison of two pachymetric systems: Slit-scanning and ultrasonic
-
Giraldez Fernandez MJ, Diaz Rey A, Cerviño A, et al. A comparison of two pachymetric systems: slit-scanning and ultrasonic. CLAO J. 2002;28: 221-223. (Pubitemid 38269645)
-
(2002)
CLAO Journal
, vol.28
, Issue.4
, pp. 221-223
-
-
Giraldez Fernandez, M.J.1
Diaz Rey, A.2
Cervino, A.3
Yebra-Pimentel, E.4
-
30
-
-
79955052778
-
Pentacam (complete anterior segment analysis instrument) [in Hungarian]
-
Módis L Jr, Vajas A, Tóth E, et al. Pentacam (complete anterior segment analysis instrument) [in Hungarian]. Szemészet. 2004;141:343-349.
-
(2004)
Szemészet
, vol.141
, pp. 343-349
-
-
Módis Jr., L.1
Vajas, A.2
Tóth, E.3
-
31
-
-
4744346127
-
Evaluation of normal corneas using the scanning-slit topography/ pachymetry system
-
DOI 10.1097/01.ico.0000126315.05519.0b
-
Módis L Jr, Langenbucher A, Seitz B. Evaluation of normal corneas using the scanning-slit topography/pachymetry system. Cornea. 2004;23: 689-694. (Pubitemid 39314778)
-
(2004)
Cornea
, vol.23
, Issue.7
, pp. 689-694
-
-
Modis Jr., L.1
Langenbucher, A.2
Seitz, B.3
-
32
-
-
14744278223
-
Zentrale und periphere hornhautpachymetrie - Normevaluation mit dem pentacam-system
-
DOI 10.1055/s-2005-857908
-
Rü fer F, Schröder A, Arvani MK, et al. Central and peripheral corneal pachymetry-standard evaluation with the Pentacam system. Klin Monbl Augenheilkd. 2005;222:117-122. (Pubitemid 40327315)
-
(2005)
Klinische Monatsblatter fur Augenheilkunde
, vol.222
, Issue.2
, pp. 117-122
-
-
Rufer, F.1
Schroder, A.2
Arvani, M.-K.3
Erb, C.4
-
33
-
-
29344455749
-
Orbscan global pachymetry: Analysis of repeated measures
-
DOI 10.1097/01.opx.0000192348.37026.09
-
Fam HB, Lim KL, Reinstein DZ. Orbscan global pachymetry: analysis of repeated measures. Optom Vis Sci. 2005;82:1047-1053. (Pubitemid 43004868)
-
(2005)
Optometry and Vision Science
, vol.82
, Issue.12
, pp. 1047-1053
-
-
Fam, H.-B.1
Lim, K.-L.2
Reinstein, D.Z.3
-
34
-
-
33644843307
-
Quantitative anatomical differences in central corneal thickness values determined with scanning-slit corneal topography and noncontact specular microscopy
-
DOI 10.1097/01.ico.0000176605.72129.2c
-
Sanchis-Gimeno JA, Herrera M, Lleó-Pérez A, et al. Quantitative anatomical differences in central corneal thickness values determined with scanning-slit corneal topography and noncontact specular microscopy. Cornea. 2006;25:203-205. (Pubitemid 43362722)
-
(2006)
Cornea
, vol.25
, Issue.2
, pp. 203-205
-
-
Sanchis-Gimeno, J.A.1
Herrera, M.2
Lleo-Perez, A.3
Alonso, L.4
Rahhal, M.S.5
Martinez-Soriano, F.6
-
35
-
-
33746960262
-
Corneal thickness measurements in normal and keratoconic eyes: Pentacam comprehensive eye scanner versus noncontact specular microscopy and ultrasound pachymetry
-
DOI 10.1016/j.jcrs.2006.02.037, PII S0886335006002276
-
Ucxakhan OO, Ozkan M, Kanpolat A. Corneal thickness measurements in normal and keratoconic eyes: Pentacam comprehensive eye scanner versus noncontact specular microscopy and ultrasound pachymetry. J Cataract Refract Surg. 2006;32:970-977. (Pubitemid 44202394)
-
(2006)
Journal of Cataract and Refractive Surgery
, vol.32
, Issue.6
, pp. 970-977
-
-
Ucakhan, O.O.1
Ozkan, M.2
Kanpolat, A.3
-
36
-
-
33646713714
-
Differences in ocular dimensions between normal and dry eyes
-
DOI 10.1007/s00276-006-0076-1
-
Sanchis-Gimeno JA, Herrera M, Sánchez-del-Campo F, et al. Differences in ocular dimensions between normal and dry eyes. Surg Radiol Anat. 2006;28:267-270. (Pubitemid 43733108)
-
(2006)
Surgical and Radiologic Anatomy
, vol.28
, Issue.3
, pp. 267-270
-
-
Sanchis-Gimeno, J.A.1
Herrera, M.2
Sanches-del-Campo, F.3
Martinez-Soriano, F.4
-
37
-
-
33846000997
-
Age-related changes in central and peripheral corneal thickness: Determination of normal values with the Orbscan II topography system1
-
DOI 10.1097/01.ico.0000240095.95067.3f, PII 0000322620070100000001
-
Rü fer F, Schröder A, Bader C, et al. Age-related changes in central and peripheral corneal thickness: determination of normal values with the Orbscan II topography system. Cornea. 2007;26:1-5. (Pubitemid 46041555)
-
(2007)
Cornea
, vol.26
, Issue.1
, pp. 1-5
-
-
Rufer, F.1
Schroder, A.2
Bader, C.3
Erb, C.4
-
38
-
-
33847125749
-
Pentacam pachometry: Comparison with non-contact specular microscopy on the central cornea and inter-session repeatability on the peripheral cornea
-
Lam AK, Chen D. Pentacam pachometry: comparison with non-contact specular microscopy on the central cornea and inter-session repeatability on the peripheral cornea. Clin Exp Optom. 2007;90:108-114.
-
(2007)
Clin Exp Optom
, vol.90
, pp. 108-114
-
-
Lam, A.K.1
Chen, D.2
-
39
-
-
34247341807
-
Central and peripheral pachymetry measurements according to age using the Pentacam rotating Scheimpflug camera
-
DOI 10.1016/j.jcrs.2006.12.025, PII S0886335007002532
-
Khoramnia R, Rabsilber TM, Auffarth GU. Central and peripheral pachymetry measurements according to age using the Pentacam rotating Scheimpflug camera. J Cataract Refract Surg. 2007;33: 830-836. (Pubitemid 46636184)
-
(2007)
Journal of Cataract and Refractive Surgery
, vol.33
, Issue.5
, pp. 830-836
-
-
Khoramnia, R.1
Rabsilber, T.M.2
Auffarth, G.U.3
-
40
-
-
37349056419
-
Anterior segment biometry with the Pentacam: Comprehensive assessment of repeatability of automated measurements
-
DOI 10.1016/j.jcrs.2007.09.013, PII S0886335007017725
-
Shankar H, Taranath D, Santhirathelagan CT, et al. Anterior segment biometry with the Pentacam: comprehensive assessment of repeatability of automated measurements. J Cataract Refract Surg. 2008;34: 103-113. (Pubitemid 350299777)
-
(2008)
Journal of Cataract and Refractive Surgery
, vol.34
, Issue.1
, pp. 103-113
-
-
Shankar, H.1
Taranath, D.2
Santhirathelagan, C.T.3
Pesudovs, K.4
-
41
-
-
49849092351
-
Distribution of central and peripheral corneal thickness in Chinese children and adults: The Guangzhou twin eye study
-
Zheng Y, Huang G, Huang W, et al. Distribution of central and peripheral corneal thickness in Chinese children and adults: the Guangzhou twin eye study. Cornea. 2008;27:776-781.
-
(2008)
Cornea
, vol.27
, pp. 776-781
-
-
Zheng, Y.1
Huang, G.2
Huang, W.3
-
42
-
-
52749095432
-
Comparison between central corneal thickness measurements by Oculus Pentacam and ultrasonic pachymetry
-
Al-Mezaine HS, Al-Amro SA, Kangave D, et al. Comparison between central corneal thickness measurements by Oculus Pentacam and ultrasonic pachymetry. Int Ophthalmol. 2008;28:333-338.
-
(2008)
Int Ophthalmol
, vol.28
, pp. 333-338
-
-
Al-Mezaine, H.S.1
Al-Amro, S.A.2
Kangave, D.3
-
43
-
-
66149149508
-
Repeatability of corneal thickness measured using an Oculus Pentacam
-
Miranda MA, Radhakrishnan H, O'Donnell C. Repeatability of corneal thickness measured using an Oculus Pentacam. Optom Vis Sci. 2009;86: 266-272.
-
(2009)
Optom Vis Sci
, vol.86
, pp. 266-272
-
-
Miranda, M.A.1
Radhakrishnan, H.2
O'Donnell, C.3
-
44
-
-
60749123573
-
The relationship of central corneal thickness (CCT) to thinnest central cornea (TCC) in healthy adults
-
Ashwin PT, Shah S, Pushpoth S, et al. The relationship of central corneal thickness (CCT) to thinnest central cornea (TCC) in healthy adults. Cont Lens Anterior Eye. 2009;32:64-67.
-
(2009)
Cont Lens Anterior Eye
, vol.32
, pp. 64-67
-
-
Ashwin, P.T.1
Shah, S.2
Pushpoth, S.3
-
45
-
-
0026008629
-
A clinical comparison of optical and ultrasonic pachometry
-
Nissen J, Hjortdal JO, Ehlers N, et al. A clinical comparison of optical and ultrasonic pachometry. Acta Ophthalmol (Copenh). 1991;69:659-663.
-
(1991)
Acta Ophthalmol (Copenh)
, vol.69
, pp. 659-663
-
-
Nissen, J.1
Hjortdal, J.O.2
Ehlers, N.3
-
46
-
-
0024412191
-
Improved biometry of the anterior eye segment
-
Kampfer T, Wegener A, Dragomirescu V, et al. Improved biometry of the anterior eye segment. Ophthalmic Res. 1989;21:239-248. (Pubitemid 19171655)
-
(1989)
Ophthalmic Research
, vol.21
, Issue.3
, pp. 239-248
-
-
Kampfer, T.1
Wegener, A.2
Dragomirescu, V.3
Hockwin, O.4
-
47
-
-
0033066788
-
Scheimpflug records without distortion - A mythos?
-
DOI 10.1159/000055525
-
Huebscher H, Fink W, Steinbrück D, et al. Scheimpflug records without distortion-a mythos? Ophthalmic Res. 1999;31:134-139. (Pubitemid 29080731)
-
(1999)
Ophthalmic Research
, vol.31
, Issue.2
, pp. 134-139
-
-
Huebscher, H.-J.1
Fink, W.2
Steinbruck, D.3
Seiler, T.4
-
48
-
-
0035022540
-
The shape of the aging human lens: Curvature, equivalent refractive index and the lens paradox
-
DOI 10.1016/S0042-6989(01)00057-8, PII S0042698901000578
-
Dubbelman M, Van der Heijde GL. The shape of the aging human lens: curvature, equivalent refractive index and the lens paradox. Vision Res. 2001;41:1867-1877. (Pubitemid 32429543)
-
(2001)
Vision Research
, vol.41
, Issue.14
, pp. 1867-1877
-
-
Dubbelman, M.1
Van Der Heijde, G.L.2
-
49
-
-
63649088722
-
Photography of the anterior eye segment according to Scheimpflug's principle: Options and limitations-a review
-
Wegener A, Laser-Junga H. Photography of the anterior eye segment according to Scheimpflug's principle: options and limitations-a review. Clin Experiment Ophthalmol. 2009;37:144-154.
-
(2009)
Clin Experiment Ophthalmol
, vol.37
, pp. 144-154
-
-
Wegener, A.1
Laser-Junga, H.2
-
50
-
-
66149192417
-
Pentacam Scheimpflug quantitative imaging of the crystalline lens and intraocular lens
-
Rosales P, Marcos S. Pentacam Scheimpflug quantitative imaging of the crystalline lens and intraocular lens. J Refract Surg. 2009;25: 421-428.
-
(2009)
J Refract Surg
, vol.25
, pp. 421-428
-
-
Rosales, P.1
Marcos, S.2
|