메뉴 건너뛰기




Volumn 69, Issue 3, 2013, Pages 698-707

Perfusion phantom: An efficient and reproducible method to simulate myocardial first-pass perfusion measurements with cardiovascular magnetic resonance

Author keywords

3T; first pass perfusion MR; gadolinium; heart; phantom

Indexed keywords

GADOLINIUM; HEART; HEMODYNAMICS; PHANTOMS;

EID: 84874358730     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24299     Document Type: Article
Times cited : (41)

References (32)
  • 1
    • 63249109110 scopus 로고    scopus 로고
    • Cardiac magnetic resonance stress testing: Results and prognosis
    • Chiribiri A, Bettencourt N, Nagel E,. Cardiac magnetic resonance stress testing: results and prognosis. Curr Cardiol Rep 2009; 11: 54-60.
    • (2009) Curr Cardiol Rep , vol.11 , pp. 54-60
    • Chiribiri, A.1    Bettencourt, N.2    Nagel, E.3
  • 2
    • 34548814710 scopus 로고    scopus 로고
    • Diagnostic performance of stress cardiac magnetic resonance imaging in the detection of coronary artery disease: A meta-analysis
    • Nandalur K, Dwamena B, Choudhri A, Nandalur M, Carlos R,. Diagnostic performance of stress cardiac magnetic resonance imaging in the detection of coronary artery disease: a meta-analysis. J Am Coll Cardiol 2007; 50: 1343-1353.
    • (2007) J Am Coll Cardiol , vol.50 , pp. 1343-1353
    • Nandalur, K.1    Dwamena, B.2    Choudhri, A.3    Nandalur, M.4    Carlos, R.5
  • 5
    • 79952109371 scopus 로고    scopus 로고
    • Quantification of myocardial perfusion by cardiovascular magnetic resonance
    • Jerosch-Herold M,. Quantification of myocardial perfusion by cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2010; 12: 57.
    • (2010) J Cardiovasc Magn Reson , vol.12 , pp. 57
    • Jerosch-Herold, M.1
  • 6
    • 44449088979 scopus 로고    scopus 로고
    • Estimation of absolute myocardial blood flow during first-pass MR perfusion imaging using a dual-bolus injection technique: Comparison to single-bolus injection method
    • Christian TF, Aletras AH, Arai AE,. Estimation of absolute myocardial blood flow during first-pass MR perfusion imaging using a dual-bolus injection technique: comparison to single-bolus injection method. J Magn Reson Imaging 2008; 27: 1271-1277.
    • (2008) J Magn Reson Imaging , vol.27 , pp. 1271-1277
    • Christian, T.F.1    Aletras, A.H.2    Arai, A.E.3
  • 9
    • 0031906266 scopus 로고    scopus 로고
    • Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolution
    • Jerosch-Herold M, Wilke N, Stillman A,. Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolution. Med Phys 1998; 25: 73-84.
    • (1998) Med Phys , vol.25 , pp. 73-84
    • Jerosch-Herold, M.1    Wilke, N.2    Stillman, A.3
  • 11
    • 0000606319 scopus 로고
    • Theoretical basis of indicator-dilution methods for measuring flow and volume
    • Zierler K,. Theoretical basis of indicator-dilution methods for measuring flow and volume. Circ Res 1962; 10: 393-407.
    • (1962) Circ Res , vol.10 , pp. 393-407
    • Zierler, K.1
  • 12
    • 50849100431 scopus 로고    scopus 로고
    • High spatial resolution myocardial perfusion cardiac magnetic resonance for the detection of coronary artery disease
    • Plein S, Kozerke S, Suerder D, Luescher T, Greenwood J, Boesiger P, Schwitter J,. High spatial resolution myocardial perfusion cardiac magnetic resonance for the detection of coronary artery disease. Eur Heart J 2008; 29: 2148-2155.
    • (2008) Eur Heart J , vol.29 , pp. 2148-2155
    • Plein, S.1    Kozerke, S.2    Suerder, D.3    Luescher, T.4    Greenwood, J.5    Boesiger, P.6    Schwitter, J.7
  • 14
    • 56149093323 scopus 로고    scopus 로고
    • K-Space and time sensitivity encoding-accelerated myocardial perfusion MR imaging at 3.0 T: Comparison with 1.5 T
    • Plein S, Schwitter J, Suerder D, Greenwood JP, Boesiger P, Kozerke S,. k-Space and time sensitivity encoding-accelerated myocardial perfusion MR imaging at 3.0 T: comparison with 1.5 T. Radiology 2008; 249: 493-500.
    • (2008) Radiology , vol.249 , pp. 493-500
    • Plein, S.1    Schwitter, J.2    Suerder, D.3    Greenwood, J.P.4    Boesiger, P.5    Kozerke, S.6
  • 15
    • 36248935661 scopus 로고    scopus 로고
    • MR myocardial perfusion imaging with k-space and time broad-use linear acquisition speed-up technique: Feasibility study
    • Gebker R, Jahnke C, Paetsch I, Schnackenburg B, Kozerke S, Bornstedt A, Fleck E, Nagel E,. MR myocardial perfusion imaging with k-space and time broad-use linear acquisition speed-up technique: feasibility study. Radiology 2007; 245: 863-871.
    • (2007) Radiology , vol.245 , pp. 863-871
    • Gebker, R.1    Jahnke, C.2    Paetsch, I.3    Schnackenburg, B.4    Kozerke, S.5    Bornstedt, A.6    Fleck, E.7    Nagel, E.8
  • 16
    • 53549099148 scopus 로고    scopus 로고
    • Measurement of myocardial frequency offsets during first pass of a gadolinium-based contrast agent in perfusion studies
    • Ferreira P, Gatehouse P, Bucciarelli-Ducci C, Wage R, Firmin D,. Measurement of myocardial frequency offsets during first pass of a gadolinium-based contrast agent in perfusion studies. Magn Reson Med 2008; 60: 860-870.
    • (2008) Magn Reson Med , vol.60 , pp. 860-870
    • Ferreira, P.1    Gatehouse, P.2    Bucciarelli-Ducci, C.3    Wage, R.4    Firmin, D.5
  • 17
    • 0036210186 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow and blood flow reserve in the presence of arterial dispersion: A simulation study
    • Schmitt M, Viallon M, Thelen M, Schreiber WG,. Quantification of myocardial blood flow and blood flow reserve in the presence of arterial dispersion: a simulation study. Magn Reson Med 2002; 47: 787-793.
    • (2002) Magn Reson Med , vol.47 , pp. 787-793
    • Schmitt, M.1    Viallon, M.2    Thelen, M.3    Schreiber, W.G.4
  • 18
    • 0035999417 scopus 로고    scopus 로고
    • Myocardial blood flow quantification with MRI by model-independent deconvolution
    • Jerosch-Herold M, Swingen C, Seethamraju RT,. Myocardial blood flow quantification with MRI by model-independent deconvolution. Med Phys 2002; 29: 886-897.
    • (2002) Med Phys , vol.29 , pp. 886-897
    • Jerosch-Herold, M.1    Swingen, C.2    Seethamraju, R.T.3
  • 19
    • 60349110366 scopus 로고    scopus 로고
    • Absolute blood contrast concentration and blood signal saturation on myocardial perfusion MRI: Estimation from CT data
    • Ishida M, Sakuma H, Murashima S, Nishida J, Senga M, Kobayasi S, Takeda K, Kato N,. Absolute blood contrast concentration and blood signal saturation on myocardial perfusion MRI: estimation from CT data. J Magn Reson Imaging 2009; 29: 205-210.
    • (2009) J Magn Reson Imaging , vol.29 , pp. 205-210
    • Ishida, M.1    Sakuma, H.2    Murashima, S.3    Nishida, J.4    Senga, M.5    Kobayasi, S.6    Takeda, K.7    Kato, N.8
  • 20
    • 79961082886 scopus 로고    scopus 로고
    • Development of a dynamic flow imaging phantom for dynamic contrast-enhanced CT
    • Driscoll B, Keller H, Coolens C,. Development of a dynamic flow imaging phantom for dynamic contrast-enhanced CT. Med Phys 2011; 38: 4866-4880.
    • (2011) Med Phys , vol.38 , pp. 4866-4880
    • Driscoll, B.1    Keller, H.2    Coolens, C.3
  • 21
    • 2942721386 scopus 로고    scopus 로고
    • Magnetic resonance versus radionuclide pharmacological stress perfusion imaging for flow-limiting stenoses of varying severity
    • Lee DC,. Magnetic resonance versus radionuclide pharmacological stress perfusion imaging for flow-limiting stenoses of varying severity. Circulation 2004; 110: 58-65.
    • (2004) Circulation , vol.110 , pp. 58-65
    • Lee, D.C.1
  • 23
    • 69449097366 scopus 로고    scopus 로고
    • K-t PCA: Temporally constrained k-t BLAST reconstruction using principal component analysis
    • Pedersen H, Kozerke S, Ringgaard S, Nehrke K, Kim WY,. k-t PCA: temporally constrained k-t BLAST reconstruction using principal component analysis. Magn Reson Med 2009; 62: 706-716.
    • (2009) Magn Reson Med , vol.62 , pp. 706-716
    • Pedersen, H.1    Kozerke, S.2    Ringgaard, S.3    Nehrke, K.4    Kim, W.Y.5
  • 26
    • 78650527024 scopus 로고    scopus 로고
    • High-resolution magnetic resonance myocardial perfusion imaging at 3.0-Tesla to detect hemodynamically significant coronary stenoses as determined by fractional flow reserve
    • Lockie T, Ishida M, Perera D, Chiribiri A, De Silva K, Kozerke S, Marber M, Nagel E, Rezavi R, Redwood S, Plein S,. High-resolution magnetic resonance myocardial perfusion imaging at 3.0-Tesla to detect hemodynamically significant coronary stenoses as determined by fractional flow reserve. J Am Coll Cardiol 2011; 57: 70-75.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 70-75
    • Lockie, T.1    Ishida, M.2    Perera, D.3    Chiribiri, A.4    De Silva, K.5    Kozerke, S.6    Marber, M.7    Nagel, E.8    Rezavi, R.9    Redwood, S.10    Plein, S.11
  • 27
    • 41949111859 scopus 로고    scopus 로고
    • Quantification of MRI measured myocardial perfusion reserve in healthy humans: A comparison with positron emission tomography
    • Fritz-Hansen T, Hove JD, Kofoed KF, Kelbaek H, Larsson HBW,. Quantification of MRI measured myocardial perfusion reserve in healthy humans: a comparison with positron emission tomography. J Magn Reson Imaging 2008; 27: 818-824.
    • (2008) J Magn Reson Imaging , vol.27 , pp. 818-824
    • Fritz-Hansen, T.1    Hove, J.D.2    Kofoed, K.F.3    Kelbaek, H.4    Larsson, H.B.W.5
  • 30
    • 67649574212 scopus 로고    scopus 로고
    • Quantitative contrast-enhanced myocardial perfusion magnetic resonance imaging: Simulation of bolus dispersion in constricted vessels
    • Graafen D, Münnemann K, Weber S, Kreitner K-F, Schreiber LM,. Quantitative contrast-enhanced myocardial perfusion magnetic resonance imaging: simulation of bolus dispersion in constricted vessels. Med Phys 2009; 36: 3099-3106.
    • (2009) Med Phys , vol.36 , pp. 3099-3106
    • Graafen, D.1    Münnemann, K.2    Weber, S.3    Kreitner, K.-F.4    Schreiber, L.M.5
  • 31
    • 0030032648 scopus 로고    scopus 로고
    • Magnetization exchange in capillaries by microcirculation affects diffusion-controlled spin-relaxation: A model which describes the effect of perfusion on relaxation enhancement by intravascular contrast agents
    • Bauer WR, Hiller KH, Roder F, Rommel E, Ertl G, Haase A,. Magnetization exchange in capillaries by microcirculation affects diffusion-controlled spin-relaxation: a model which describes the effect of perfusion on relaxation enhancement by intravascular contrast agents. Magn Reson Med 1996; 35: 43-55.
    • (1996) Magn Reson Med , vol.35 , pp. 43-55
    • Bauer, W.R.1    Hiller, K.H.2    Roder, F.3    Rommel, E.4    Ertl, G.5    Haase, A.6
  • 32
    • 0028836223 scopus 로고
    • Effects of myocardial water exchange on T1 enhancement during bolus administration of MR contrast agents
    • Judd RM, Atalay MK, Rottman GA, Zerhouni EA,. Effects of myocardial water exchange on T1 enhancement during bolus administration of MR contrast agents. Magn Reson Med 1995; 33: 215-223.
    • (1995) Magn Reson Med , vol.33 , pp. 215-223
    • Judd, R.M.1    Atalay, M.K.2    Rottman, G.A.3    Zerhouni, E.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.