메뉴 건너뛰기




Volumn 26, Issue 1, 2013, Pages 81-98

Challenges and current methods for attenuation correction in PET/MR

Author keywords

Attenuation correction; Emission; PET MR; Template; Transmission; UTE

Indexed keywords

DIAGNOSTIC AGENT; RADIOPHARMACEUTICAL AGENT;

EID: 84874108578     PISSN: 09685243     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10334-012-0334-7     Document Type: Review
Times cited : (128)

References (65)
  • 2
    • 33745111311 scopus 로고    scopus 로고
    • Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI
    • 16595498
    • Pichler BJ, Judenhofer MS, Catana C (2006) Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI. J Nucl Med 47:639-647
    • (2006) J Nucl Med , vol.47 , pp. 639-647
    • Pichler, B.J.1    Judenhofer, M.S.2    Catana, C.3
  • 7
    • 34548104447 scopus 로고    scopus 로고
    • Is MR-guided attenuation correction a viable option for dual-modality PET/MR Imaging?
    • 17709821 10.1148/radiol.2443070092
    • Zaidi H (2007) Is MR-guided attenuation correction a viable option for dual-modality PET/MR Imaging? Radiology 244:639-642
    • (2007) Radiology , vol.244 , pp. 639-642
    • Zaidi, H.1
  • 8
    • 0003017412 scopus 로고
    • Photon cross sections, attenuation coefficients, and energy absorption coefficients from 10 keV to 100 GeV
    • National Bureau of Standards, Washington, DC
    • Hubbel J (1969) Photon cross sections, attenuation coefficients, and energy absorption coefficients from 10 keV to 100 GeV. NSRDS-NBS 29. National Bureau of Standards, Washington, DC
    • (1969) NSRDS-NBS 29
    • Hubbel, J.1
  • 9
    • 0003682469 scopus 로고
    • Tissue substitutes in radiation, dosimetry and measurement
    • International Commission on Radiation Units and Measurements (ICRU) ICRU, Bethesda, MD
    • International Commission on Radiation Units and Measurements (ICRU) (1989) Tissue substitutes in radiation, dosimetry and measurement. ICRU Report 44. ICRU, Bethesda, MD
    • (1989) ICRU Report 44
  • 11
    • 80855128883 scopus 로고    scopus 로고
    • The effect of errors in segmented attenuation maps on PET quantification
    • 22047365 10.1118/1.3651640
    • Keereman V, Van Holen R, Mollet P, Vandenberghe S (2011) The effect of errors in segmented attenuation maps on PET quantification. Med Phys 38:6010-6019
    • (2011) Med Phys , vol.38 , pp. 6010-6019
    • Keereman, V.1    Van Holen, R.2    Mollet, P.3    Vandenberghe, S.4
  • 12
    • 0022665040 scopus 로고
    • Problems in signal-to-noise ratio for attenuation correction in high resolution PET
    • 10.1109/TNS.1987.4337350
    • Dahlbom M, Hoffman E (1987) Problems in signal-to-noise ratio for attenuation correction in high resolution PET. IEEE T Nucl Sci 34:288-293
    • (1987) IEEE T Nucl Sci , vol.34 , pp. 288-293
    • Dahlbom, M.1    Hoffman, E.2
  • 13
    • 0028341310 scopus 로고
    • Attenuation correction in PET using single photon transmission measurement
    • 7935213 10.1118/1.597394 1:STN:280:DyaK2M%2FitV2mtw%3D%3D
    • deKemp RA, Nahmias C (1994) Attenuation correction in PET using single photon transmission measurement. Med Phys 21:771-778
    • (1994) Med Phys , vol.21 , pp. 771-778
    • Dekemp, R.A.1    Nahmias, C.2
  • 14
    • 0033870513 scopus 로고    scopus 로고
    • A combined PET/CT scanner for clinical oncology
    • 10945530 1:STN:280:DC%2BD3cvitFCguw%3D%3D
    • Beyer T, Townsend D, Brun T (2000) A combined PET/CT scanner for clinical oncology. J Nucl Med 41:1369-1379
    • (2000) J Nucl Med , vol.41 , pp. 1369-1379
    • Beyer, T.1    Townsend, D.2    Brun, T.3
  • 15
    • 0031791001 scopus 로고    scopus 로고
    • Attenuation correction for a combined 3D PET/CT scanner
    • 9800714 10.1118/1.598392 1:STN:280:DyaK1M%2FhslSqtA%3D%3D
    • Kinahan P, Townsend D, Beyer T, Sashin D (1998) Attenuation correction for a combined 3D PET/CT scanner. Med Phys 25:2046-2053
    • (1998) Med Phys , vol.25 , pp. 2046-2053
    • Kinahan, P.1    Townsend, D.2    Beyer, T.3    Sashin, D.4
  • 16
    • 0036093165 scopus 로고    scopus 로고
    • PET attenuation coefficients from CT images: Experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients
    • 10.1007/s00259-002-0796-3 1:STN:280:DC%2BD38zms1Gjtg%3D%3D
    • Burger C, Goerres G, Schoenes S, Buck A (2002) PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients. Eur J Nucl Med 29:922-927
    • (2002) Eur J Nucl Med , vol.29 , pp. 922-927
    • Burger, C.1    Goerres, G.2    Schoenes, S.3    Buck, A.4
  • 17
    • 0037655094 scopus 로고    scopus 로고
    • Dual- modality PET/CT imaging: The effect of respiratory motion on combined image quality in clinical oncology
    • 12582813 10.1007/s00259-002-1097-6
    • Beyer T, Antoch G, Blodgett T, Freudenberg LF, Akhurst T, Mueller S (2003) Dual- modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology. Eur J Nucl Med Mol Imaging 30:588-596
    • (2003) Eur J Nucl Med Mol Imaging , vol.30 , pp. 588-596
    • Beyer, T.1    Antoch, G.2    Blodgett, T.3    Freudenberg, L.F.4    Akhurst, T.5    Mueller, S.6
  • 19
    • 60549089954 scopus 로고    scopus 로고
    • PET/MRI system design
    • 19104809 10.1007/s00259-008-1008-6
    • Delso G, Ziegler S (2009) PET/MRI system design. Eur J Nucl Med Mol Imaging 36(Suppl 1):S86-S92
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.SUPPL. 1
    • Delso, G.1    Ziegler, S.2
  • 20
    • 78049448620 scopus 로고    scopus 로고
    • Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scanner
    • 20647598 10.1088/0031-9155/55/15/011 1:STN:280:DC%2BC3cnovVCiug%3D%3D
    • Delso G, Martinez-Moller A, Bundschuh R, Ladebeck R, Candidus Y, Faul D, Ziegler S (2010) Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scanner. Phys Med Biol 55:4361-4374
    • (2010) Phys Med Biol , vol.55 , pp. 4361-4374
    • Delso, G.1    Martinez-Moller, A.2    Bundschuh, R.3    Ladebeck, R.4    Candidus, Y.5    Faul, D.6    Ziegler, S.7
  • 22
    • 33745851216 scopus 로고    scopus 로고
    • Whole-body 18F-FDG PET/CT in the presence of truncation artifacts
    • 16391192
    • Beyer T, Bockisch A, Kühl H, Martinez MJ (2006) Whole-body 18F-FDG PET/CT in the presence of truncation artifacts. J Nucl Med 47:91-99
    • (2006) J Nucl Med , vol.47 , pp. 91-99
    • Beyer, T.1    Bockisch, A.2    Kühl, H.3    Martinez, M.J.4
  • 23
    • 84860811781 scopus 로고    scopus 로고
    • MRI-based attenuation correction for hybrid PET/MRI systems: A four-class tissue segmentation technique using a combined ultra-short echo time (UTE)/Dixon MR sequence
    • 22505568 10.2967/jnumed.111.092577
    • Berker Y, Franke J, Salomon A, Palmowski M, Donker H, Temur Y, Mottaghy F, Kuhl C, Izquierdo-Garcia D, Fayad Z, Kiessling F, Schulz V (2012) MRI-based attenuation correction for hybrid PET/MRI systems: a four-class tissue segmentation technique using a combined ultra-short echo time (UTE)/Dixon MR sequence. J Nucl Med 53:796-804
    • (2012) J Nucl Med , vol.53 , pp. 796-804
    • Berker, Y.1    Franke, J.2    Salomon, A.3    Palmowski, M.4    Donker, H.5    Temur, Y.6    Mottaghy, F.7    Kuhl, C.8    Izquierdo-Garcia, D.9    Fayad, Z.10    Kiessling, F.11    Schulz, V.12
  • 24
    • 14244251257 scopus 로고    scopus 로고
    • Atlas-guided non-uniform attenuation correction in cerebral 3D PET imaging
    • 15734362 10.1016/j.neuroimage.2004.11.021
    • Montandon M, Zaidi H (2005) Atlas-guided non-uniform attenuation correction in cerebral 3D PET imaging. Neuroimage 25:278-286
    • (2005) Neuroimage , vol.25 , pp. 278-286
    • Montandon, M.1    Zaidi, H.2
  • 25
    • 48149097720 scopus 로고    scopus 로고
    • Alternative methods for attenuation correction for PET images in MR-PET scanners
    • Rota Kops E, Herzog H (2007) Alternative methods for attenuation correction for PET images in MR-PET scanners. IEEE Nucl Sci Conf R 4327-4330
    • (2007) IEEE Nucl Sci Conf R , pp. 4327-4330
    • Rota Kops, E.1    Herzog, H.2
  • 26
    • 67649185917 scopus 로고    scopus 로고
    • Template based attenuation correction for PET in MR-PET scanners
    • Rota Kops E, Herzog H (2008) Template based attenuation correction for PET in MR-PET scanners. IEEE Nucl Sci Conf R 3786-3789
    • (2008) IEEE Nucl Sci Conf R , pp. 3786-3789
    • Rota Kops, E.1    Herzog, H.2
  • 27
    • 57349155316 scopus 로고    scopus 로고
    • MRI-based attenuation correction for PET/MRI: A novel approach combining pattern recognition and atlas registration
    • 18927326 10.2967/jnumed.107.049353
    • Hofmann M, Steinke F, Scheel V (2008) MRI-based attenuation correction for PET/MRI: a novel approach combining pattern recognition and atlas registration. J Nucl Med 49:1875-1883
    • (2008) J Nucl Med , vol.49 , pp. 1875-1883
    • Hofmann, M.1    Steinke, F.2    Scheel, V.3
  • 28
    • 80052644918 scopus 로고    scopus 로고
    • MRI-based attenuation correction for whole-body PET/MRI: Quantitative evaluation of segmentation- and atlas-based methods
    • 21828115 10.2967/jnumed.110.078949
    • Hofmann M, Bezrukov I, Mantlik F, Aschoff P, Steinke F, Beyer T, Pichler BJ, Scholkopf B (2011) MRI-based attenuation correction for whole-body PET/MRI: quantitative evaluation of segmentation- and atlas-based methods. J Nucl Med 52:1392-1399
    • (2011) J Nucl Med , vol.52 , pp. 1392-1399
    • Hofmann, M.1    Bezrukov, I.2    Mantlik, F.3    Aschoff, P.4    Steinke, F.5    Beyer, T.6    Pichler, B.J.7    Scholkopf, B.8
  • 31
    • 0035355056 scopus 로고    scopus 로고
    • Absolute activity quantitation from projections using an analytical approach: Comparison with iterative methods in Tc-99 m and I-123 brain SPECT
    • 10.1109/23.940161
    • El Fakhri G, Kijewski MF, Moore SC (2001) Absolute activity quantitation from projections using an analytical approach: comparison with iterative methods in Tc-99 m and I-123 brain SPECT. IEEE T Nucl Sci 48:768-773
    • (2001) IEEE T Nucl Sci , vol.48 , pp. 768-773
    • El Fakhri, G.1    Kijewski, M.F.2    Moore, S.C.3
  • 32
    • 0038247944 scopus 로고    scopus 로고
    • Magnetic resonance imaging-guided attenuation and scatter corrections in three-dimensional brain positron emission tomography
    • 12773003 10.1118/1.1569270
    • Zaidi H, Montandon M, Slosman D (2003) Magnetic resonance imaging-guided attenuation and scatter corrections in three-dimensional brain positron emission tomography. Med Phys 30:937-948
    • (2003) Med Phys , vol.30 , pp. 937-948
    • Zaidi, H.1    Montandon, M.2    Slosman, D.3
  • 33
    • 1642471697 scopus 로고    scopus 로고
    • Attenuation compensation in cerebral 3D PET: Effect of the attenuation map on absolute and relative quantitation
    • 14574512 10.1007/s00259-003-1325-8
    • Zaidi H, Montandon M, Slosman D (2004) Attenuation compensation in cerebral 3D PET: effect of the attenuation map on absolute and relative quantitation. Eur J Nucl Med Mol Imaging 31:52-63
    • (2004) Eur J Nucl Med Mol Imaging , vol.31 , pp. 52-63
    • Zaidi, H.1    Montandon, M.2    Slosman, D.3
  • 36
    • 77951197260 scopus 로고    scopus 로고
    • MR-based attenuation correction for a whole-body sequential PET/MR system
    • Hu Z, Ojha N, Renisch S, Schulz V, Torres I, Buhl A, Pal D, Muswick G, Penatzer J, Guo T, Bönert P, Tung C, Kaste J, Morich M, Havens T, Maniawski P, Schafer W, GuÂ̈nther R, Krombach G, Shao L (2009) MR-based attenuation correction for a whole-body sequential PET/MR system. IEEE Nucl Sci Conf R 3508-3512
    • (2009) IEEE Nucl Sci Conf R , pp. 3508-3512
    • Hu Z, O.1
  • 38
    • 76949090527 scopus 로고    scopus 로고
    • Three-region MRI-based whole-body attenuation correction for automated PET reconstruction
    • 20152722 10.1016/j.nucmedbio.2009.11.002 1:CAS:528:DC%2BC3cXhs1ygtLY%3D
    • Steinberg J, Jia G, Sammet S, Zhang J, Hall N, Knopp M (2010) Three-region MRI-based whole-body attenuation correction for automated PET reconstruction. Nucl Med Biol 37:227-235
    • (2010) Nucl Med Biol , vol.37 , pp. 227-235
    • Steinberg, J.1    Jia, G.2    Sammet, S.3    Zhang, J.4    Hall, N.5    Knopp, M.6
  • 40
    • 0021132985 scopus 로고
    • Simple proton spectroscopic imaging
    • 6089263 1:STN:280:DyaL2c3pvFWhsQ%3D%3D
    • Dixon W (1984) Simple proton spectroscopic imaging. Radiology 153:189-194
    • (1984) Radiology , vol.153 , pp. 189-194
    • Dixon, W.1
  • 42
    • 0030662535 scopus 로고    scopus 로고
    • Two-point Dixon technique for water-fat signal decomposition with B0 inhomogeneity correction
    • 9402188 10.1002/mrm.1910380606 1:STN:280:DyaK1c%2FmtlOrsg%3D%3D
    • Coombs B, Szumowski J, Coshow W (1997) Two-point Dixon technique for water-fat signal decomposition with B0 inhomogeneity correction. Magn Reson Med 38:884-889
    • (1997) Magn Reson Med , vol.38 , pp. 884-889
    • Coombs, B.1    Szumowski, J.2    Coshow, W.3
  • 45
    • 0037236412 scopus 로고    scopus 로고
    • Magnetic resonance imaging of short T2 components in tissue
    • 12565203 10.1053/crad.2003.1157 1:STN:280:DC%2BD3s%2Flslaluw%3D%3D
    • Gatehouse P, Bydder G (2003) Magnetic resonance imaging of short T2 components in tissue. Clin Radiol 58:1-19
    • (2003) Clin Radiol , vol.58 , pp. 1-19
    • Gatehouse, P.1    Bydder, G.2
  • 46
    • 3543114382 scopus 로고    scopus 로고
    • Contrast enhancement of short T2 tissues using ultrashort TE (UTE) pulse sequences
    • 15262547 10.1016/j.crad.2003.09.025 1:STN:280:DC%2BD2czlvVentg%3D%3D
    • Robson M, Gatehouse P, So P, Bell J (2004) Contrast enhancement of short T2 tissues using ultrashort TE (UTE) pulse sequences. Clin Radiol 59:720-726
    • (2004) Clin Radiol , vol.59 , pp. 720-726
    • Robson, M.1    Gatehouse, P.2    So, P.3    Bell, J.4
  • 47
    • 77952302436 scopus 로고    scopus 로고
    • MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences
    • 20439508 10.2967/jnumed.109.065425
    • Keereman V, Fierens Y, Broux T, De Deene Y, Lonneux M, Vandenberghe S (2010) MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences. J Nucl Med 51:812-818
    • (2010) J Nucl Med , vol.51 , pp. 812-818
    • Keereman, V.1    Fierens, Y.2    Broux, T.3    De Deene, Y.4    Lonneux, M.5    Vandenberghe, S.6
  • 48
    • 77957038794 scopus 로고    scopus 로고
    • Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain proto-type
    • 20810759 10.2967/jnumed.109.069112 1:CAS:528:DC%2BC3cXht1ejsLvI
    • Catana C, Kouwe A, Benner T, Michel C, Hamm M, Fenchel M, Fischl B, Rosen B, Schmand M, Sorensen A (2010) Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain proto-type. J Nucl Med 51:1431-1438
    • (2010) J Nucl Med , vol.51 , pp. 1431-1438
    • Catana, C.1    Kouwe, A.2    Benner, T.3    Michel, C.4    Hamm, M.5    Fenchel, M.6    Fischl, B.7    Rosen, B.8    Schmand, M.9    Sorensen, A.10
  • 49
    • 79959534469 scopus 로고    scopus 로고
    • CT substitute derived from MRI sequences with ultrashort echo time
    • 21776807 10.1118/1.3578928
    • Johansson A, Karlsson M, Nyholm T (2011) CT substitute derived from MRI sequences with ultrashort echo time. Med Phys 38:2708-2717
    • (2011) Med Phys , vol.38 , pp. 2708-2717
    • Johansson, A.1    Karlsson, M.2    Nyholm, T.3
  • 50
    • 84867552130 scopus 로고    scopus 로고
    • Simultaneous MR-compatible emission and transmission imaging for PET using time-of-flight information
    • doi: 10.1109/TMI.2012.2198831
    • Mollet P, Keereman V, Clementel E, Vandenberghe S (2012) Simultaneous MR-compatible emission and transmission imaging for PET using time-of-flight information. IEEE Trans Med Imaging. doi: 10.1109/TMI.2012.2198831
    • (2012) IEEE Trans Med Imaging.
    • Mollet, P.1    Keereman, V.2    Clementel, E.3    Vandenberghe, S.4
  • 53
    • 0030082269 scopus 로고    scopus 로고
    • A hybrid attenuation correction technique to compensate for lung density in 3-D total body PET
    • 10.1109/23.485973
    • Tai Y, Lin K, Dahlbom M, Hoffman E (1996) A hybrid attenuation correction technique to compensate for lung density in 3-D total body PET. IEEE T Nucl Sci 43:323-330
    • (1996) IEEE T Nucl Sci , vol.43 , pp. 323-330
    • Tai, Y.1    Lin, K.2    Dahlbom, M.3    Hoffman, E.4
  • 54
    • 0030082270 scopus 로고    scopus 로고
    • Adaptive, segmented attenuation correction for whole-body PET imaging
    • 10.1109/23.485974
    • Xu M, Cutler P, Luk W (1996) Adaptive, segmented attenuation correction for whole-body PET imaging. IEEE T Nucl Sci 43:331-336
    • (1996) IEEE T Nucl Sci , vol.43 , pp. 331-336
    • Xu, M.1    Cutler, P.2    Luk, W.3
  • 55
    • 0018457105 scopus 로고
    • A new approach to the emission computerized tomography problem: Simultaneous calculation of attenuation and activity coefficients
    • 10.1109/TNS.1979.4330535
    • Censor Y, Gustafson DE, Lent A, Tuy H (1979) A new approach to the emission computerized tomography problem: simultaneous calculation of attenuation and activity coefficients. IEEE Trans Nucl Sci 26:2775-2779
    • (1979) IEEE Trans Nucl Sci , vol.26 , pp. 2775-2779
    • Censor, Y.1    Gustafson, D.E.2    Lent, A.3    Tuy, H.4
  • 56
    • 0032588587 scopus 로고    scopus 로고
    • Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinograms
    • 10416801 10.1109/42.774167 1:STN:280:DyaK1MzktlWqsg%3D%3D
    • Nuyts J, Dupont P, Stroobants S, Benninck R, Mortelmans L, Suetens P (1999) Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinograms. IEEE Trans Med Imaging 18:393-403
    • (1999) IEEE Trans Med Imaging , vol.18 , pp. 393-403
    • Nuyts, J.1    Dupont, P.2    Stroobants, S.3    Benninck, R.4    Mortelmans, L.5    Suetens, P.6
  • 57
    • 0033360505 scopus 로고    scopus 로고
    • A new approach towards simultaneous activity and attenuation reconstruction in emission tomography
    • 10.1088/0266-5611/15/4/307
    • Dicken V (1999) A new approach towards simultaneous activity and attenuation reconstruction in emission tomography. Inverse Prob 15:931-960
    • (1999) Inverse Prob , vol.15 , pp. 931-960
    • Dicken, V.1
  • 58
    • 79551660998 scopus 로고    scopus 로고
    • Why is TOF PET reconstruction a more robust method in the presence of inconsistent data?
    • 21119224 10.1088/0031-9155/56/1/010
    • Conti M (2011) Why is TOF PET reconstruction a more robust method in the presence of inconsistent data? Phys Med Biol 56:155-168
    • (2011) Phys Med Biol , vol.56 , pp. 155-168
    • Conti, M.1
  • 59
    • 84856853168 scopus 로고    scopus 로고
    • Time-of-flight PET data determine the attenuation sinogram up to a constant
    • 22290428 10.1088/0031-9155/57/4/885
    • Defrise M, Rezzaei A, Nuyts J (2012) Time-of-flight PET data determine the attenuation sinogram up to a constant. Phys Med Biol 57:885-899
    • (2012) Phys Med Biol , vol.57 , pp. 885-899
    • Defrise, M.1    Rezzaei, A.2    Nuyts, J.3
  • 62
    • 79952162564 scopus 로고    scopus 로고
    • Simultaneous reconstruction of activity and attenuation for PET/MR
    • 21118768 10.1109/TMI.2010.2095464
    • Salomon A, Goedicke A, Schweizer B, Aach T, Schulz V (2011) Simultaneous reconstruction of activity and attenuation for PET/MR. IEEE Trans Med Imaging 30:804-813
    • (2011) IEEE Trans Med Imaging , vol.30 , pp. 804-813
    • Salomon, A.1    Goedicke, A.2    Schweizer, B.3    Aach, T.4    Schulz, V.5
  • 63
    • 77953505299 scopus 로고    scopus 로고
    • The effect of limited MR field of view in MR/PET attenuation correction
    • 20632591 10.1118/1.3431576
    • Delso G, Martinez-Möller A, Bundschuh R, Nekolla S, Ziegler S (2010) The effect of limited MR field of view in MR/PET attenuation correction. Med Phys 37:2804-2812
    • (2010) Med Phys , vol.37 , pp. 2804-2812
    • Delso, G.1    Martinez-Moller, A.2    Bundschuh, R.3    Nekolla, S.4    Ziegler, S.5
  • 64
    • 84861883596 scopus 로고    scopus 로고
    • Variable lung density consideration in attenuation correction of whole-body PET/MRI
    • 22566600 10.2967/jnumed.111.098350
    • Marshall H, Prato F, Deans L, Théberge J, Thompson R, Stodilka R (2012) Variable lung density consideration in attenuation correction of whole-body PET/MRI. J Nucl Med 53:977-984
    • (2012) J Nucl Med , vol.53 , pp. 977-984
    • Marshall, H.1    Prato, F.2    Deans, L.3    Théberge, J.4    Thompson, R.5    Stodilka, R.6