메뉴 건너뛰기




Volumn , Issue , 2009, Pages 2530-2533

Attenuation correction in MR-PET scanners with segmented T1-weighted MR images

Author keywords

[No Author keywords available]

Indexed keywords

ATTENUATION COEFFICIENT; ATTENUATION CORRECTION; ATTENUATION MAPS; BRAIN TISSUE; BRAIN TUMORS; CORTICAL REGIONS; CT SCAN; CT VOLUME; EMISSION DATA; FDG PET; GAUSSIAN KERNELS; GREY MATTERS; HOUNSFIELD UNITS; MR IMAGES; MR SCANNERS; NEW APPROACHES; PET DATA; PET IMAGES; PET SCAN; PET SCANNER; SELECTION CRITERIA; SOFT TISSUE; TRANSMISSION DATA;

EID: 77951174895     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2009.5402034     Document Type: Conference Paper
Times cited : (21)

References (11)
  • 1
    • 67649185917 scopus 로고    scopus 로고
    • Template Based Attenuation Correction for PET in MR-PET Scanners
    • E. Rota Kops, H. Herzog, "Template Based Attenuation Correction for PET in MR-PET Scanners," IEEE NSS/MIC Conference Record, pp. 4327-4330, 2008.
    • (2008) IEEE NSS/MIC Conference Record , pp. 4327-4330
    • Rota Kops, E.1    Herzog, H.2
  • 4
    • 6344229991 scopus 로고    scopus 로고
    • MRI-Based Individual 3D Region-of-Interest Atlases of the Human Brain. A New Method for Analyzing Functional Data
    • G. Wagenknecht, H.J. Kaiser, U. Buell, and O. Sabri, "MRI-Based Individual 3D Region-of-Interest Atlases of the Human Brain. A New Method for Analyzing Functional Data, " Methods Inf Med, 43:383-390, 2004.
    • (2004) Methods Inf Med , vol.43 , pp. 383-390
    • Wagenknecht, G.1    Kaiser, H.J.2    Buell, U.3    Sabri, O.4
  • 5
    • 77951181255 scopus 로고    scopus 로고
    • Wissensbasierte Segmentierung schwächungsrelevanter Regionen des Kopfes in T1- Gewichteten MRT-Bilddaten für die Schwächungskorrektur in MR-PET Systemen
    • in German
    • G. Wagenknecht, E. Rota Kops, H. Herzog, "Wissensbasierte Segmentierung schwächungsrelevanter Regionen des Kopfes in T1- gewichteten MRT-Bilddaten für die Schwächungskorrektur in MR-PET Systemen, " (in German) Nuklearmedizin, 48:V147, 2009.
    • (2009) Nuklearmedizin , vol.48
    • Wagenknecht, G.1    Rota Kops, E.2    Herzog, H.3
  • 7
    • 0042925674 scopus 로고    scopus 로고
    • 18F]CPFPX and positron emission tomography
    • DOI 10.1016/S1053-8119(03)00241-6
    • A. Bauer, M.H. Holschbach, P.T. Meyer, C. Boy, H. Herzog, R.A. Olsson, H.H. Coenen, K. Zilles, "In Vivo Imaging of Adenosine A1 Receptors in the Human Brain with [18F]CPFPX and Positron Emission Tomography, " Neuroimage, 19:1760-1769, 2003. (Pubitemid 37025871)
    • (2003) NeuroImage , vol.19 , Issue.4 , pp. 1760-1769
    • Bauer, A.1    Holschbach, M.H.2    Meyer, P.T.3    Boy, C.4    Herzog, H.5    Olsson, R.A.6    Coenen, H.H.7    Zilles, K.8
  • 10
    • 0036093165 scopus 로고    scopus 로고
    • PET Attenuation Coefficients from CT Images: Experimental Evaluation of the Transformation of CT into PET 511-keV Attenuation Coefficients
    • C. Burger, G. Goerres, S. Schoenes, "PET Attenuation Coefficients from CT Images: Experimental Evaluation of the Transformation of CT into PET 511-keV Attenuation Coefficients," EJNMMI, 29:922-927, 2002.
    • (2002) EJNMMI , vol.29 , pp. 922-927
    • Burger, C.1    Goerres, G.2    Schoenes, S.3
  • 11
    • 77951153891 scopus 로고    scopus 로고
    • Attenuation Correction in MR-PET Scanners. Influence of the Smoothness of the Attenuation Maps
    • in German
    • E. Rota Kops, J. Scheins, L. Tellmann, H. Herzog, "Attenuation Correction in MR-PET Scanners. Influence of the Smoothness of the Attenuation Maps," (in German). Nuklearmedizin, 48:V22, 2009.
    • (2009) Nuklearmedizin , vol.48
    • Rota Kops, E.1    Scheins, J.2    Tellmann, L.3    Herzog, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.