메뉴 건너뛰기




Volumn 26, Issue 3, 2013, Pages 329-335

Electrocardiogram-triggered, higher order, projection-based B0 shimming allows for fast and reproducible shim convergence in spinal cord 1H MRS

Author keywords

B0 shimming; FASTMAP; In vivo; MRS; Spinal cord; VAPOR

Indexed keywords

CENTRAL NERVOUS SYSTEMS; CHEMICAL COMPOSITIONS; FASTMAP; FIELD DISTORTIONS; FIELD MAPPING; IN-VIVO; MRS; PREPARATION PHASIS; REPRODUCIBILITIES; ROBUST METHODS; SPECTRAL QUALITY; SPINAL CORDS; TECHNICAL CHALLENGES;

EID: 84873990894     PISSN: 09523480     EISSN: 10991492     Source Type: Journal    
DOI: 10.1002/nbm.2852     Document Type: Article
Times cited : (28)

References (28)
  • 1
    • 0032464264 scopus 로고    scopus 로고
    • Human cerebral neoplasms studied using MR spectroscopy: a review
    • Kaibara T, Tyson RL, Sutherland GR. Human cerebral neoplasms studied using MR spectroscopy: a review. Biochem. Cell Biol. 1998; 76(2-3): 477-486.
    • (1998) Biochem. Cell Biol. , vol.76 , Issue.2-3 , pp. 477-486
    • Kaibara, T.1    Tyson, R.L.2    Sutherland, G.R.3
  • 2
    • 44949263061 scopus 로고    scopus 로고
    • Quantitative magnetic resonance spectroscopy in the entire human cervical spinal cord and beyond at 3T
    • Henning A, Schar M, Kollias SS, Boesiger P, Dydak U. Quantitative magnetic resonance spectroscopy in the entire human cervical spinal cord and beyond at 3T. Magn. Reson. Med. 2008; 59(6): 1250-1258.
    • (2008) Magn. Reson. Med. , vol.59 , Issue.6 , pp. 1250-1258
    • Henning, A.1    Schar, M.2    Kollias, S.S.3    Boesiger, P.4    Dydak, U.5
  • 3
    • 2942729475 scopus 로고    scopus 로고
    • Quantitative proton magnetic resonance spectroscopy of the cervical spinal cord
    • Cooke FJ, Blamire AM, Manners DN, Styles P, Rajagopalan B. Quantitative proton magnetic resonance spectroscopy of the cervical spinal cord. Magn. Reson. Med. 2004; 51(6): 1122-1128.
    • (2004) Magn. Reson. Med. , vol.51 , Issue.6 , pp. 1122-1128
    • Cooke, F.J.1    Blamire, A.M.2    Manners, D.N.3    Styles, P.4    Rajagopalan, B.5
  • 4
    • 0023636904 scopus 로고
    • Spatial localization in NMR spectroscopy in vivo
    • Bottomley PA. Spatial localization in NMR spectroscopy in vivo. Ann. N. Y. Acad. Sci. 1987; 508(1): 333-348.
    • (1987) Ann. N. Y. Acad. Sci. , vol.508 , Issue.1 , pp. 333-348
    • Bottomley, P.A.1
  • 6
    • 33846071071 scopus 로고    scopus 로고
    • Quantitative proton magnetic resonance spectroscopy of the human cervical spinal cord at 3 Tesla
    • Marliani AF, Clementi V, Albini-Riccioli L, Agati R, Leonardi M. Quantitative proton magnetic resonance spectroscopy of the human cervical spinal cord at 3 Tesla. Magn. Reson. Med. 2007; 57(1): 160-163.
    • (2007) Magn. Reson. Med. , vol.57 , Issue.1 , pp. 160-163
    • Marliani, A.F.1    Clementi, V.2    Albini-Riccioli, L.3    Agati, R.4    Leonardi, M.5
  • 8
    • 4644313555 scopus 로고    scopus 로고
    • MR spectroscopy of cervical spinal cord in patients with multiple sclerosis
    • Kendi AT, Tan FU, Kendi M, Yilmaz S, Huvaj S, Tellioglu S. MR spectroscopy of cervical spinal cord in patients with multiple sclerosis. Neuroradiology, 2004; 46(9): 764-769.
    • (2004) Neuroradiology , vol.46 , Issue.9 , pp. 764-769
    • Kendi, A.T.1    Tan, F.U.2    Kendi, M.3    Yilmaz, S.4    Huvaj, S.5    Tellioglu, S.6
  • 10
    • 0027375098 scopus 로고
    • Estimation of metabolite concentrations from localized in vivo proton NMR spectra
    • Provencher SW. Estimation of metabolite concentrations from localized in vivo proton NMR spectra. Magn. Reson. Med. 1993; 30(6): 672-679.
    • (1993) Magn. Reson. Med. , vol.30 , Issue.6 , pp. 672-679
    • Provencher, S.W.1
  • 12
    • 33749177862 scopus 로고    scopus 로고
    • Optimized detection of lactate at high fields using inner volume saturation
    • Edden RA, Schar M, Hillis AE, Barker PB. Optimized detection of lactate at high fields using inner volume saturation. Magn. Reson. Med. 2006; 56(4): 912-917.
    • (2006) Magn. Reson. Med. , vol.56 , Issue.4 , pp. 912-917
    • Edden, R.A.1    Schar, M.2    Hillis, A.E.3    Barker, P.B.4
  • 13
    • 44049117202 scopus 로고
    • Fast, noniterative shimming of spatially localized signals. In vivo analysis of the magnetic field along axes
    • Gruetter R, Boesch C. Fast, noniterative shimming of spatially localized signals. In vivo analysis of the magnetic field along axes. J. Magn. Reson. 1992; 96(2): 323-334.
    • (1992) J. Magn. Reson. , vol.96 , Issue.2 , pp. 323-334
    • Gruetter, R.1    Boesch, C.2
  • 14
    • 0027200329 scopus 로고
    • Automatic, localized in vivo adjustment of all first- and second-order shim coils
    • Gruetter R. Automatic, localized in vivo adjustment of all first- and second-order shim coils. Magn. Reson. Med. 1993; 29(6): 804-811.
    • (1993) Magn. Reson. Med. , vol.29 , Issue.6 , pp. 804-811
    • Gruetter, R.1
  • 15
    • 0030726451 scopus 로고    scopus 로고
    • Improvements on an in vivo automatic shimming method [FASTERMAP]
    • Shen J, Rycyna RE, Rothman DL. Improvements on an in vivo automatic shimming method [FASTERMAP]. Magn. Reson. Med. 1997; 38(5): 834-839.
    • (1997) Magn. Reson. Med. , vol.38 , Issue.5 , pp. 834-839
    • Shen, J.1    Rycyna, R.E.2    Rothman, D.L.3
  • 16
    • 0342948677 scopus 로고    scopus 로고
    • Field mapping without reference scan using asymmetric echo-planar techniques
    • Gruetter R, Tkáč I. Field mapping without reference scan using asymmetric echo-planar techniques. Magn. Reson. Med. 2000; 43(2): 319-323.
    • (2000) Magn. Reson. Med. , vol.43 , Issue.2 , pp. 319-323
    • Gruetter, R.1    Tkáč, I.2
  • 18
    • 0035089444 scopus 로고    scopus 로고
    • Hydrodynamic modeling of cerebrospinal fluid motion within the spinal cavity
    • Loth F, Yardimci MA, Alperin N. Hydrodynamic modeling of cerebrospinal fluid motion within the spinal cavity. J. Biomech. Eng. 2001; 123(1): 71-79.
    • (2001) J. Biomech. Eng. , vol.123 , Issue.1 , pp. 71-79
    • Loth, F.1    Yardimci, M.A.2    Alperin, N.3
  • 20
    • 37549007917 scopus 로고    scopus 로고
    • SELOVS: brain MRSI localization based on highly selective T1- and B1- insensitive outer-volume suppression at 3T
    • Henning A, Schar M, Schulte RF, Wilm B, Pruessmann KP, Boesiger P. SELOVS: brain MRSI localization based on highly selective T1- and B1- insensitive outer-volume suppression at 3T. Magn. Reson. Med. 2008; 59(1): 40-51.
    • (2008) Magn. Reson. Med. , vol.59 , Issue.1 , pp. 40-51
    • Henning, A.1    Schar, M.2    Schulte, R.F.3    Wilm, B.4    Pruessmann, K.P.5    Boesiger, P.6
  • 21
    • 0025340810 scopus 로고
    • In vivo proton spectroscopy in presence of eddy currents
    • Klose U. In vivo proton spectroscopy in presence of eddy currents. Magn. Reson. Med. 1990; 14(1): 26-30.
    • (1990) Magn. Reson. Med. , vol.14 , Issue.1 , pp. 26-30
    • Klose, U.1
  • 22
    • 0001876029 scopus 로고
    • Computer simulations in magnetic resonance. An object-oriented programming approach
    • Smith SA, Levante TO, Meier BH, Ernst RR. Computer simulations in magnetic resonance. An object-oriented programming approach. J. Magn. Reson. 1994; 106(1): 75-105.
    • (1994) J. Magn. Reson. , vol.106 , Issue.1 , pp. 75-105
    • Smith, S.A.1    Levante, T.O.2    Meier, B.H.3    Ernst, R.R.4
  • 27
    • 0034983072 scopus 로고    scopus 로고
    • Effect of degenerate spherical harmonics and a method for automatic shimming of oblique slices
    • Shen J. Effect of degenerate spherical harmonics and a method for automatic shimming of oblique slices. NMR Biomed. 2001; 14(3): 177-183.
    • (2001) NMR Biomed. , vol.14 , Issue.3 , pp. 177-183
    • Shen, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.