메뉴 건너뛰기




Volumn 7622, Issue PART 2, 2010, Pages

The dependence of image quality on the number of high and low kVp projections in dual energy CT using the prior image constrained compressed sensing (PICCS) algorithm

Author keywords

Compressed sensing; CT; Dual energy; Reconstruction

Indexed keywords

CT; DUAL ENERGY; DUAL-ENERGY CT; DUAL-ENERGY IMAGING; ENERGY SEPARATIONS; FILTERED BACK PROJECTION; HIGH IMAGE QUALITY; HIGH SLEW RATES; IMAGE RECONSTRUCTION METHODS; SLEW RATE; SWITCHING TECHNIQUES;

EID: 84873932659     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.844471     Document Type: Conference Paper
Times cited : (7)

References (20)
  • 1
    • 0015911128 scopus 로고
    • Computerized transverse axial scanning (tomography): Part i. description of system
    • Hounsfield, G. N., "Computerized transverse axial scanning (tomography): Part i. description of system," British Journal of Radiology 46, 1016 1022 (1973).
    • (1973) British Journal of Radiology , vol.46 , pp. 1016-1022
    • Hounsfield, G.N.1
  • 2
    • 0017108614 scopus 로고
    • Energy-selective reconstruction in x-ray comptued tomography
    • Alvarez, R. and Macovski, A., "Energy-selective reconstruction in x-ray comptued tomography," Phys. Med. Biol. 21, 733-744 (1976).
    • (1976) Phys. Med. Biol. , vol.21 , pp. 733-744
    • Alvarez, R.1    MacOvski, A.2
  • 3
    • 0018667403 scopus 로고
    • Noise considerations in dual energy ct scanning
    • Kelcz, F., Joseph, P. M., and Hilal, S., "Noise considerations in dual energy ct scanning," Med. Phys. 6(5) (1979).
    • (1979) Med. Phys. , vol.6 , Issue.5
    • Kelcz, F.1    Joseph, P.M.2    Hilal, S.3
  • 4
    • 63849101176 scopus 로고    scopus 로고
    • Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration
    • Primak, A., Giraldo, J., Liu, X., Yu, L., and McCollough, C, "Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration," Med. Phys. 36, 1359 (2009).
    • (2009) Med. Phys. , vol.36 , pp. 1359
    • Primak, A.1    Giraldo, J.2    Liu, X.3    Yu, L.4    McCollough, C.5
  • 6
    • 35148816698 scopus 로고    scopus 로고
    • Image-domain material decomposition using photon-counting ct
    • Taguchi, K., Zhang, M., Frey, E., and Xu, J., "Image-domain material decomposition using photon-counting ct," Proc. of SPIE 6510, 651008 (2007).
    • (2007) Proc. of SPIE , vol.6510 , pp. 651008
    • Taguchi, K.1    Zhang, M.2    Frey, E.3    Xu, J.4
  • 7
    • 43149117710 scopus 로고    scopus 로고
    • Analysis of fast kv switching in dual energy ct using a pre-reconstruction decomposition technique
    • Zou, Y. and Silver, M., "Analysis of fast kv switching in dual energy ct using a pre-reconstruction decomposition technique," Proc. of SPIE 6913, 691313 (2008).
    • (2008) Proc. of SPIE , vol.6913 , pp. 691313
    • Zou, Y.1    Silver, M.2
  • 9
    • 66749125974 scopus 로고    scopus 로고
    • Monochromatic ct image representation via fast switching dual kvp
    • Wu, X., Langan, D., Benson, T., Pack, J., Schmitz, A., and Tkaczyk, J., "Monochromatic ct image representation via fast switching dual kvp," Proc. of SPIE 7258, 725845 (2009).
    • (2009) Proc. of SPIE , vol.7258 , pp. 725845
    • Wu, X.1    Langan, D.2    Benson, T.3    Pack, J.4    Schmitz, A.5    Tkaczyk, J.6
  • 10
    • 66749089320 scopus 로고    scopus 로고
    • Fast kvp switching ct imaging of a dynamic cardiac phantom
    • Pack, J., Wu, D. L. X., Xu, D., Benson, T., Schmitz, A., and Tkaczyk, J., "Fast kvp switching ct imaging of a dynamic cardiac phantom," Proc. of SPIE 7258, 725843 (2009).
    • (2009) Proc. of SPIE , vol.7258 , pp. 725843
    • Pack, J.1    Wu, D.L.X.2    Xu, D.3    Benson, T.4    Schmitz, A.5    Tkaczyk, J.6
  • 11
    • 38849164794 scopus 로고    scopus 로고
    • Prior image constrained compressed sensing (pices): A method to accurately reconstruct dynamic ct images from highly undersampled projection data sets
    • Chen, G. H., Tang, J., and Leng, S., "Prior image constrained compressed sensing (pices): A method to accurately reconstruct dynamic ct images from highly undersampled projection data sets," Med. Phys. 35, 660-663 (2008).
    • (2008) Med. Phys. , vol.35 , Issue.660 , pp. 663
    • Chen, G.H.1    Tang, J.2    Leng, S.3
  • 12
    • 66449095635 scopus 로고    scopus 로고
    • Temporal resolution improvement using pices in mdet cardiac imaging
    • Chen, G. H., Tang, J., and Hsieh, J., "Temporal resolution improvement using pices in mdet cardiac imaging," Med. Phys. 36, 2130 2135 (2009).
    • (2009) Med. Phys. , vol.36 , pp. 2130-2135
    • Chen, G.H.1    Tang, J.2    Hsieh, J.3
  • 15
    • 9244249165 scopus 로고    scopus 로고
    • Specktr: A computational tool for x-ray spectral analysis and imaging system optimization
    • Siewerdsen, J., Waese, A., Moseley, D., Richard, S., and Jaffray, D., "Specktr: A computational tool for x-ray spectral analysis and imaging system optimization," Med. Phys. 31, 3057-3067 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 3057-3067
    • Siewerdsen, J.1    Waese, A.2    Moseley, D.3    Richard, S.4    Jaffray, D.5
  • 16
    • 0030657556 scopus 로고    scopus 로고
    • An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140kv
    • Boone, ,J. M. and Seibert, J. A., "An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140kv," Med. Phys. 24, 1661-1670 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1661-1670
    • Boone, J.M.1    Seibert, J.A.2
  • 17
    • 0003735899 scopus 로고
    • Principles of computerized tomographic imaging
    • Kak, A. C. and Slaney, M., "Principles of computerized tomographic imaging," IEEE Press New York (1988).
    • (1988) IEEE Press New York
    • Kak, A.C.1    Slaney, M.2
  • 18
    • 31744440684 scopus 로고    scopus 로고
    • Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information
    • Candes. K., Romberg, J., and Tao, T. "Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information," INEEE Trans. Inf. Theory 52, 489 509 (2006).
    • (2006) INEEE Trans. Inf. Theory , vol.52 , pp. 489-509
    • Candes, K.1    Romberg, J.2    Tao, T.3
  • 19
    • 33645712892 scopus 로고    scopus 로고
    • Compressed sensing
    • Donoho, D., "Compressed sensing," INEEE Trans. Inf. Theory 52, 1289 1306 (2006).
    • (2006) INEEE Trans. Inf. Theory , vol.52 , pp. 1289-1306
    • Donoho, D.1
  • 20
    • 36849088522 scopus 로고    scopus 로고
    • Sparse mri: The application of compressed sensing for rapid mr imaging
    • Liistig, M., Donoho, D., and Pauly, J., "Sparse mri: The application of compressed sensing for rapid mr imaging," Magnetic Resonance in Medicine 58, 1182C1195 (2007).
    • (2007) Magnetic Resonance in Medicine , vol.58 , pp. 1182-1195
    • Liistig, M.1    Donoho, D.2    Pauly, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.