메뉴 건너뛰기




Volumn 36, Issue 4, 2009, Pages 1359-1369

Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration

Author keywords

Dual energy CT; dual source CT; x ray beam filtration; x ray spectra

Indexed keywords

CALCIUM; HYDROXYAPATITE; IODINE; IRON; TIN;

EID: 63849101176     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3083567     Document Type: Article
Times cited : (277)

References (27)
  • 1
    • 0017108614 scopus 로고
    • Energy-selective reconstructions in x-ray computerised tomography
    • 0031-9155 10.1088/0031-9155/21/5/002.
    • R. E. Alvarez and A. A. Macovski, " Energy-selective reconstructions in x-ray computerised tomography.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/21/5/002 21, 733-744 (1976).
    • (1976) Phys. Med. Biol. , vol.21 , pp. 733-744
    • Alvarez, R.E.1    Macovski, A.A.2
  • 2
    • 0022528983 scopus 로고
    • Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies
    • 0094-2405 10.1118/1.595958.
    • W. A. Kalender, W. H. Perman, J. R. Vetter, and E. Klotz, " Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies.," Med. Phys. 0094-2405 10.1118/1.595958 13, 334-339 (1986).
    • (1986) Med. Phys. , vol.13 , pp. 334-339
    • Kalender, W.A.1    Perman, W.H.2    Vetter, J.R.3    Klotz, E.4
  • 4
    • 45149128319 scopus 로고    scopus 로고
    • Coronary stent patency: Dual-energy multidetector CT assessment in a pilot study with anthropomorphic phantom
    • 0033-8419
    • D. T. Boll, E. M. Merkle, E. K. Paulson, and T. R. Fleiter, " Coronary stent patency: Dual-energy multidetector CT assessment in a pilot study with anthropomorphic phantom.," Radiology 247, 687-695 (2008). 0033-8419
    • (2008) Radiology , vol.247 , pp. 687-695
    • Boll, D.T.1    Merkle, E.M.2    Paulson, E.K.3    Fleiter, T.R.4
  • 8
    • 33745496524 scopus 로고    scopus 로고
    • X-ray computed tomography
    • 0031-9155 10.1088/0031-9155/51/13/R03.
    • W. A. Kalender, " X-ray computed tomography.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/51/13/R03 51, R29-R43 (2006).
    • (2006) Phys. Med. Biol. , vol.51
    • Kalender, W.A.1
  • 10
    • 54049156093 scopus 로고    scopus 로고
    • Dual-energy CT of the heart for diagnosing coronary artery stenosis and myocardial ischemia-initial experience
    • 0938-7994
    • B. Ruzsics, H. Lee, P. L. Zwerner, M. Gebregziabher, P. Costello, and U. J. Schoepf, " Dual-energy CT of the heart for diagnosing coronary artery stenosis and myocardial ischemia-initial experience.," Eur. Radiol. 18, 2414-2424 (2008). 0938-7994
    • (2008) Eur. Radiol. , vol.18 , pp. 2414-2424
    • Ruzsics, B.1    Lee, H.2    Zwerner, P.L.3    Gebregziabher, M.4    Costello, P.5    Schoepf, U.J.6
  • 12
    • 45449095184 scopus 로고    scopus 로고
    • An initial qualitative study of dual-energy CT in the knee ligaments
    • 0361-803X
    • C. Sun, F. Miao, X. M. Wang, T. Wang, R. Ma, D. P. Wang, and C. Liu, " An initial qualitative study of dual-energy CT in the knee ligaments.," Surg. Radiol. Anat. 30, 443-447 (2008). 0361-803X
    • (2008) Surg. Radiol. Anat. , vol.30 , pp. 443-447
    • Sun, C.1    Miao, F.2    Wang, X.M.3    Wang, T.4    Ma, R.5    Wang, D.P.6    Liu, C.7
  • 14
    • 43149117710 scopus 로고    scopus 로고
    • Analysis of fast kV-switching in dual energy CT using a pre-reconstruction decomposition technique
    • 0277-786X 10.1117/12.772826.
    • Y. Zou and M. Silver, " Analysis of fast kV-switching in dual energy CT using a pre-reconstruction decomposition technique.," Proc. SPIE 0277-786X 10.1117/12.772826 6913, 691313-1-691313-12 (2008).
    • (2008) Proc. SPIE , vol.6913
    • Zou, Y.1    Silver, M.2
  • 15
    • 53749097507 scopus 로고    scopus 로고
    • Calcified vascular plaque specimens: Assessment with cardiac dual-energy multidetector CT in anthropomorphically moving heart phantom
    • 0033-8419
    • D. T. Boll, E. M. Merkle, E. K. Paulson, R. A. Mirza, and T. R. Fleiter, " Calcified vascular plaque specimens: Assessment with cardiac dual-energy multidetector CT in anthropomorphically moving heart phantom.," Radiology 249, 119-126 (2008). 0033-8419
    • (2008) Radiology , vol.249 , pp. 119-126
    • Boll, D.T.1    Merkle, E.M.2    Paulson, E.K.3    Mirza, R.A.4    Fleiter, T.R.5
  • 16
    • 0028140493 scopus 로고
    • X-ray tube potential, filtration, and detector considerations in dual-energy chest radiography
    • 0094-2405 10.1118/1.597373.
    • D. M. Gauntt and G. T. Barnes, " X-ray tube potential, filtration, and detector considerations in dual-energy chest radiography.," Med. Phys. 0094-2405 10.1118/1.597373 21, 203-218 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 203-218
    • Gauntt, D.M.1    Barnes, G.T.2
  • 17
    • 0025158069 scopus 로고
    • Dual-energy mammography: A detector analysis
    • 0094-2405 10.1118/1.596548.
    • J. M. Boone, G. S. Shaber, and M. Tecotzky, " Dual-energy mammography: A detector analysis.," Med. Phys. 0094-2405 10.1118/1.596548 17, 665-675 (1990).
    • (1990) Med. Phys. , vol.17 , pp. 665-675
    • Boone, J.M.1    Shaber, G.S.2    Tecotzky, M.3
  • 18
    • 33744809318 scopus 로고    scopus 로고
    • Optimization of a flat-panel based real time dual-energy system for cardiac imaging
    • 0094-2405 10.1118/1.2174131.
    • J. L. Ducote, T. Xu, and S. Molloi, " Optimization of a flat-panel based real time dual-energy system for cardiac imaging.," Med. Phys. 0094-2405 10.1118/1.2174131 33, 1562-1568 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 1562-1568
    • Ducote, J.L.1    Xu, T.2    Molloi, S.3
  • 20
    • 0018667403 scopus 로고
    • Noise considerations in dual energy CT scanning
    • 0094-2405 10.1118/1.594520.
    • F. Kelcz, P. M. Joseph, and S. K. Hilal, " Noise considerations in dual energy CT scanning.," Med. Phys. 0094-2405 10.1118/1.594520 6, 418-425 (1979).
    • (1979) Med. Phys. , vol.6 , pp. 418-425
    • Kelcz, F.1    Joseph, P.M.2    Hilal, S.K.3
  • 21
    • 0018858655 scopus 로고
    • Split-filter computed tomography: A simple technique for dual energy scanning
    • 0363-8715
    • B. Rutt and A. Fenster, " Split-filter computed tomography: A simple technique for dual energy scanning.," J. Comput. Assist. Tomogr. 4, 501-509 (1980). 0363-8715
    • (1980) J. Comput. Assist. Tomogr. , vol.4 , pp. 501-509
    • Rutt, B.1    Fenster, A.2
  • 23
    • 0030919839 scopus 로고    scopus 로고
    • Estimation of a photon energy spectrum for a computed tomography scanner
    • 0094-2405 10.1118/1.598159.
    • C. Ruth and P. M. Joseph, " Estimation of a photon energy spectrum for a computed tomography scanner.," Med. Phys. 0094-2405 10.1118/1.598159 24, 695-702 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 695-702
    • Ruth, C.1    Joseph, P.M.2
  • 24
    • 0030657556 scopus 로고    scopus 로고
    • An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV
    • 0094-2405 10.1118/1.597953.
    • J. M. Boone and J. A. Seibert, " An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV.," Med. Phys. 0094-2405 10.1118/1.597953 24, 1661-1670 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1661-1670
    • Boone, J.M.1    Seibert, J.A.2
  • 25
    • 0142070759 scopus 로고    scopus 로고
    • Image reconstruction and performance evaluation for ECG-gated spiral scanning with a 16-slice CT system
    • 0094-2405 10.1118/1.1593637.
    • T. Flohr, B. Ohnesorge, H. Bruder, K. Stierstorfer, J. Simon, C. Suess, and S. Schaller, " Image reconstruction and performance evaluation for ECG-gated spiral scanning with a 16-slice CT system.," Med. Phys. 0094-2405 10.1118/1.1593637 30, 2650-2662 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 2650-2662
    • Flohr, T.1    Ohnesorge, B.2    Bruder, H.3    Stierstorfer, K.4    Simon, J.5    Suess, C.6    Schaller, S.7
  • 27
    • 34147137929 scopus 로고    scopus 로고
    • Quantitative x-ray imaging of intraplaque hemorrhage in aortas of apoE(-/-)/LDL(-/-) double knockout mice
    • 0020-9996
    • A. C. Langheinrich, A. Michniewicz, D. G. Sedding, B. Lai, S. M. Jorgensen, R. M. Bohle, and E. L. Ritman, " Quantitative x-ray imaging of intraplaque hemorrhage in aortas of apoE(-/-)/LDL(-/-) double knockout mice.," Invest. Radiol. 42, 263-273 (2007). 0020-9996
    • (2007) Invest. Radiol. , vol.42 , pp. 263-273
    • Langheinrich, A.C.1    Michniewicz, A.2    Sedding, D.G.3    Lai, B.4    Jorgensen, S.M.5    Bohle, R.M.6    Ritman, E.L.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.