1
-
-
35148829155
-
Microcomputed tomography with a photon-counting X-ray detector
-
SPIE: San Diego, CA, USA. p
-
Frey, E.C., et al., Microcomputed tomography with a photon-counting X-ray detector, in Medical Imaging 2007: Physics of Medical Imaging. 2007, SPIE: San Diego, CA, USA. p. 6510-62.
-
(2007)
Medical Imaging 2007: Physics of Medical Imaging
, pp. 6510-6562
-
-
Frey, E.C.1
-
2
-
-
84888716950
-
X-ray color scanner with multiple energy discrimination capability
-
SPIE: San Diego, CA, USA. p, A
-
Tomita, Y., et al., X-ray color scanner with multiple energy discrimination capability, in Medical Imaging 2005: Physics of Medical Imaging. 2005, SPIE: San Diego, CA, USA. p. 59220 A.
-
(2005)
Medical Imaging 2005: Physics of Medical Imaging
, pp. 59220
-
-
Tomita, Y.1
-
4
-
-
84888725684
-
Novel CT detector based on an inorganic scintillator working in photon-counting mode
-
SPIE: San Diego, CA, USA. p
-
Berar, P., et al., Novel CT detector based on an inorganic scintillator working in photon-counting mode, in Medical Imaging 2006: Physics of Medical Imaging. 2006, SPIE: San Diego, CA, USA. p. 61420V-1.
-
(2006)
Medical Imaging 2006: Physics of Medical Imaging
-
-
Berar, P.1
-
5
-
-
0017108614
-
Energy-selective reconstructions in X-ray computerised tomography
-
Alvarez, R.E. and A. Macovski, Energy-selective reconstructions in X-ray computerised tomography. Physics in Medicine and Biology, 1976. 21(5): p. 733-744.
-
(1976)
Physics in Medicine and Biology
, vol.21
, Issue.5
, pp. 733-744
-
-
Alvarez, R.E.1
Macovski, A.2
-
6
-
-
35148835355
-
-
Frey, E.C., et al., Investigation of the use of photon counting detectors with energy discrimination capability for material decomposition in micro-computed tomography, in Medical Imaging 2007: Physics of Medical Imaging. 2007, SPIE: San Diego, CA, USA. p. 6510-09.
-
Frey, E.C., et al., Investigation of the use of photon counting detectors with energy discrimination capability for material decomposition in micro-computed tomography, in Medical Imaging 2007: Physics of Medical Imaging. 2007, SPIE: San Diego, CA, USA. p. 6510-09.
-
-
-
-
8
-
-
0022528983
-
Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies
-
Kalender, W.A., et al., Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies. Medical Physics, 1986. 13(3): p. 334-339.
-
(1986)
Medical Physics
, vol.13
, Issue.3
, pp. 334-339
-
-
Kalender, W.A.1
-
9
-
-
0018667403
-
Noise considerations in dual energy CTscanning
-
Kelcz, F., P.M. Joseph, and S.K. Hilal, Noise considerations in dual energy CTscanning. Medical Physics, 1979. 6(5): p. 418-425.
-
(1979)
Medical Physics
, vol.6
, Issue.5
, pp. 418-425
-
-
Kelcz, F.1
Joseph, P.M.2
Hilal, S.K.3
-
10
-
-
85054755416
-
Signal-to-Noise Monte-Carlo Analysis of Base Material Decomposed CT Projections
-
San Diego, CA, USA: IEEE
-
Heismann, B.J. Signal-to-Noise Monte-Carlo Analysis of Base Material Decomposed CT Projections, in Medical Imaging 2006: Physics of Medical Imaging. 2006. San Diego, CA, USA: IEEE.
-
(2006)
Medical Imaging 2006: Physics of Medical Imaging
-
-
Heismann, B.J.1
-
11
-
-
31444454089
-
First performance evaluation of a dual-source CT (DSCT) system
-
Flohr, T.G., et al., First performance evaluation of a dual-source CT (DSCT) system. European Radiology, 2006. V16(2): p. 256-268.
-
(2006)
European Radiology
, vol.16
, Issue.2
, pp. 256-268
-
-
Flohr, T.G.1
-
12
-
-
84888755239
-
Effect of heart rate on CT angiography using the enhanced cardiac model of the 4D NCAT
-
San Diego, CA, USA: SPIE
-
Segars, W.P., et al. Effect of heart rate on CT angiography using the enhanced cardiac model of the 4D NCAT. in Medical Imaging 2006: Physics of Medical Imaging. 2006. San Diego, CA, USA: SPIE.
-
(2006)
Medical Imaging 2006: Physics of Medical Imaging
-
-
Segars, W.P.1
-
13
-
-
84888676979
-
-
Seltzer, J.H.H.a.S.M. Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients (version 1.4, from I keV to 20 MeV for Elements Z= 1 to 92 and 48 Additional Substances of Dosimetric Interest*. 2004 [cited; Originally published as NISTIR 5632, National Institute of Standards and Technology, Gaithersburg, MD 1995, Available from: Available:, 2007, February 7, National Institute of Standards and Technology, Gaithersburg, MD
-
Seltzer, J.H.H.a.S.M. Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients (version 1.4) -from I keV to 20 MeV for Elements Z= 1 to 92 and 48 Additional Substances of Dosimetric Interest*. 2004 [cited; Originally published as NISTIR 5632, National Institute of Standards and Technology, Gaithersburg, MD (1995)]. Available from: Available: http://physics.nist.gov/xaamdi [2007, February 7]. National Institute of Standards and Technology, Gaithersburg, MD.
-
-
-
|