메뉴 건너뛰기




Volumn 13, Issue 6, 2012, Pages 170-180

An automated method for comparing motion artifacts in cine four-dimensional computed tomography images

Author keywords

Four dimensional computed tomography; Image similarity; Motion artifacts; Normalized correlation coefficient

Indexed keywords


EID: 84873553798     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v13i6.3838     Document Type: Article
Times cited : (17)

References (20)
  • 1
    • 14644439819 scopus 로고    scopus 로고
    • Comparison of helical and cine acquisitions for 4D-CT imaging with multislice CT
    • Pan T. Comparison of helical and cine acquisitions for 4D-CT imaging with multislice CT. Med Phys. 2005;32(2):627-34.
    • (2005) Med Phys. , vol.32 , Issue.2 , pp. 627-634
    • Pan, T.1
  • 2
    • 17844371743 scopus 로고    scopus 로고
    • Four-dimensional computed tomography: image formation and clinical protocol
    • Rietzel E, Pan T, Chen GTY. Four-dimensional computed tomography: image formation and clinical protocol. Med Phys. 2005;32(4):874-89.
    • (2005) Med Phys. , vol.32 , Issue.4 , pp. 874-889
    • Rietzel, E.1    Pan, T.2    Chen, G.T.Y.3
  • 3
    • 31044444598 scopus 로고    scopus 로고
    • Displacement-based binning of time-dependent computed tomography image data sets
    • Fitzpatrick MJ, Starkschall G, Antolak JA, et al. Displacement-based binning of time-dependent computed tomography image data sets. Med Phys. 2006;33(1):235-46.
    • (2006) Med Phys. , vol.33 , Issue.1 , pp. 235-246
    • Fitzpatrick, M.J.1    Starkschall, G.2    Antolak, J.A.3
  • 4
    • 35649001395 scopus 로고    scopus 로고
    • Improvement of the cine-CT based 4D-CT imaging
    • Pan T, Sun X, Luo D. Improvement of the cine-CT based 4D-CT imaging. Med Phys. 2007;34(11):4499-503.
    • (2007) Med Phys. , vol.34 , Issue.11 , pp. 4499-4503
    • Pan, T.1    Sun, X.2    Luo, D.3
  • 5
    • 54049105620 scopus 로고    scopus 로고
    • Retrospective analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients
    • Yamamoto T, Langner U, Loo BW Jr, Shen J, Keall PJ. Retrospective analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients. Int J Radiat Oncol Biol Phys. 2008;72(4):1250-58.
    • (2008) Int J Radiat Oncol Biol Phys. , vol.72 , Issue.4 , pp. 1250-1258
    • Yamamoto, T.1    Langner, U.2    Loo Jr., B.W.3    Shen, J.4    Keall, P.J.5
  • 6
    • 0842327786 scopus 로고    scopus 로고
    • Artifacts in computed tomography scanning of moving objects
    • Chen GTY, Kung JH, Beaudette KP. Artifacts in computed tomography scanning of moving objects. Semin Radiat Oncol. 2004;14(1):19-26.
    • (2004) Semin Radiat Oncol. , vol.14 , Issue.1 , pp. 19-26
    • Chen, G.T.Y.1    Kung, J.H.2    Beaudette, K.P.3
  • 7
    • 0037237809 scopus 로고    scopus 로고
    • Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning
    • Ford EC, Mageras GS, Yorke E, Ling CC. Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning. Med Phys. 2003;30(1):88-97.
    • (2003) Med Phys. , vol.30 , Issue.1 , pp. 88-97
    • Ford, E.C.1    Mageras, G.S.2    Yorke, E.3    Ling, C.C.4
  • 8
    • 0842306300 scopus 로고    scopus 로고
    • 4-dimensional computed tomography imaging and treatment planning
    • Keall P. 4-dimensional computed tomography imaging and treatment planning. Semin Radiat Oncol. 2004;14(1):81-90.
    • (2004) Semin Radiat Oncol. , vol.14 , Issue.1 , pp. 81-90
    • Keall, P.1
  • 9
    • 78650061267 scopus 로고    scopus 로고
    • Commissioning and quality assurance for a respiratory training system based on audiovisual biofeedback
    • Cui G, Gopalan S, Yamamoto T, Berger J, Maxim PG, Keall PJ. Commissioning and quality assurance for a respiratory training system based on audiovisual biofeedback. J Appl Clin Med Phys. 2010;11(4):42-56.
    • (2010) J Appl Clin Med Phys. , vol.11 , Issue.4 , pp. 42-56
    • Cui, G.1    Gopalan, S.2    Yamamoto, T.3    Berger, J.4    Maxim, P.G.5    Keall, P.J.6
  • 10
    • 45749086196 scopus 로고    scopus 로고
    • Development and preliminary evaluation of a prototype audiovisual biofeedback device incorporating a patient-specific guiding waveform
    • Venkat RB, Sawant A, Suh Y, George R, Keall PJ. Development and preliminary evaluation of a prototype audiovisual biofeedback device incorporating a patient-specific guiding waveform. Phys Med Biol. 2008;53(11):N197-N208.
    • (2008) Phys Med Biol. , vol.53 , Issue.11
    • Venkat, R.B.1    Sawant, A.2    Suh, Y.3    George, R.4    Keall, P.J.5
  • 11
    • 33746625978 scopus 로고    scopus 로고
    • A comparison between amplitude sorting and phase-angle sorting using external respiratory measurement for 4D CT
    • Lu W, Parikh PJ, Hubenschmidt JP, Bradley JD, Low DA. A comparison between amplitude sorting and phase-angle sorting using external respiratory measurement for 4D CT. Med Phys. 2006;33(8):2964-74.
    • (2006) Med Phys. , vol.33 , Issue.8 , pp. 2964-2974
    • Lu, W.1    Parikh, P.J.2    Hubenschmidt, J.P.3    Bradley, J.D.4    Low, D.A.5
  • 12
    • 34249751028 scopus 로고    scopus 로고
    • Phase and amplitude binning for 4D-CT imaging
    • Abdelnour AF, Nehmeh SA, Pan T, et al. Phase and amplitude binning for 4D-CT imaging. Phys Med Biol. 2007;52(12):3515-29.
    • (2007) Phys Med Biol. , vol.52 , Issue.12 , pp. 3515-3529
    • Abdelnour, A.F.1    Nehmeh, S.A.2    Pan, T.3
  • 13
    • 52949140550 scopus 로고    scopus 로고
    • Prospective displacement and velocity-based cine 4D CT
    • Langner UW and Keall PJ. Prospective displacement and velocity-based cine 4D CT. Med Phys. 2008;35(10):4501-12.
    • (2008) Med Phys. , vol.35 , Issue.10 , pp. 4501-4512
    • Langner, U.W.1    Keall, P.J.2
  • 14
    • 33846632761 scopus 로고    scopus 로고
    • An optical flow based method for improved reconstruction of 4D CT data sets acquired during free breathing
    • Ehrhardt J, Werner R, Saring D, et al. An optical flow based method for improved reconstruction of 4D CT data sets acquired during free breathing. Med Phys. 2007;34(2):711-21.
    • (2007) Med Phys. , vol.34 , Issue.2 , pp. 711-721
    • Ehrhardt, J.1    Werner, R.2    Saring, D.3
  • 16
    • 63649084829 scopus 로고    scopus 로고
    • A fully automated non-external marker 4D-CT sorting algorithm using a serial cine scanning protocol
    • Carnes G, Gaede S, Yu E, Dyk JV, Battista J, Lee TY. A fully automated non-external marker 4D-CT sorting algorithm using a serial cine scanning protocol. Phys Med Biol. 2009;54(7):2049-66.
    • (2009) Phys Med Biol. , vol.54 , Issue.7 , pp. 2049-2066
    • Carnes, G.1    Gaede, S.2    Yu, E.3    Dyk, J.V.4    Battista, J.5    Lee, T.Y.6
  • 17
    • 70349783471 scopus 로고    scopus 로고
    • 4D CT sorting based on patient internal anatomy
    • Li R, Lewis JH, Cervino LI, Jiang SB. 4D CT sorting based on patient internal anatomy. Phys Med Biol. 2009;54(15):4821-33.
    • (2009) Phys Med Biol. , vol.54 , Issue.15 , pp. 4821-4833
    • Li, R.1    Lewis, J.H.2    Cervino, L.I.3    Jiang, S.B.4
  • 18
    • 84873529459 scopus 로고    scopus 로고
    • Signal processing toolbox, Natick, MA: The Mathworks; 2012. Available from:
    • Signal processing toolbox. R2012a Documentation. Natick, MA: The Mathworks; 2012. Available from: http://www.mathworks.com/help/toolbox/signal/ref/xcorr2.html
    • R2012a Documentation
  • 19
    • 1242338927 scopus 로고    scopus 로고
    • 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT
    • Pan T, Lee TY, Rietzel E, Chen GT. 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. Med Phys. 2004;31(2):333-40.
    • (2004) Med Phys. , vol.31 , Issue.2 , pp. 333-340
    • Pan, T.1    Lee, T.Y.2    Rietzel, E.3    Chen, G.T.4
  • 20
    • 79959537366 scopus 로고    scopus 로고
    • Reducing 4D CT artifacts using optimized sorting based on anatomic similarity
    • Johnston E, Diehn M, Murphy JD, Loo JBW, Maxim PG. Reducing 4D CT artifacts using optimized sorting based on anatomic similarity. Med Phys. 2011;38(5): 2424-29.
    • (2011) Med Phys. , vol.38 , Issue.5 , pp. 2424-2429
    • Johnston, E.1    Diehn, M.2    Murphy, J.D.3    Loo, J.B.W.4    Maxim, P.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.