메뉴 건너뛰기




Volumn 38, Issue 5, 2011, Pages 2424-2429

Reducing 4D CT artifacts using optimized sorting based on anatomic similarity

Author keywords

4D CT; image artifacts; phase and displacement sorting; respiratory motion; two dimensional correlation coefficient

Indexed keywords

COMPUTERIZED TOMOGRAPHY; RESPIRATORY MECHANICS;

EID: 79959537366     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3577601     Document Type: Article
Times cited : (24)

References (14)
  • 1
    • 14644439819 scopus 로고    scopus 로고
    • Comparison of helical and cine acquisitions for 4D-CT imaging with multislice CT
    • DOI 10.1118/1.1855013
    • T. Pan, Comparison of helical and cine acquisitions for 4D-CT imaging with multislice CT., Med. Phys. 32, 627-634 (2005). 10.1118/1.1855013 (Pubitemid 40322344)
    • (2005) Medical Physics , vol.32 , Issue.2 , pp. 627-634
    • Pan, T.1
  • 2
    • 0842306300 scopus 로고    scopus 로고
    • 4-Dimensional Computed Tomography Imaging and Treatment Planning
    • DOI 10.1053/j.semradonc.2003.10.006
    • P. Keall, 4-dimensional computed tomography imaging and treatment planning., Semin. Radiat. Oncol. 14, 81-90 (2004). 10.1053/j.semradonc.2003.10. 006 (Pubitemid 38168957)
    • (2004) Seminars in Radiation Oncology , vol.14 , Issue.1 , pp. 81-90
    • Keall, P.1
  • 5
    • 33746625978 scopus 로고    scopus 로고
    • A comparison between amplitude sorting and phase-angle sorting using external respiratory measurement for 4D CT
    • DOI 10.1118/1.2219772
    • W. Lu, P. J. Parikh, J. P. Hubenschmidt, J. D. Bradley, and D. A. Low, A comparison between amplitude sorting and phase-angle sorting using external respiratory measurement for 4D CT., Med. Phys. 33, 2964-2974 (2006). 10.1118/1.2219772 (Pubitemid 44154570)
    • (2006) Medical Physics , vol.33 , Issue.8 , pp. 2964-2974
    • Lu, W.1    Parikh, P.J.2    Hubenschmidt, J.P.3    Bradley, J.D.4    Low, D.A.5
  • 6
    • 31844442905 scopus 로고    scopus 로고
    • Improving retrospective sorting of 4D computed tomography data
    • DOI 10.1118/1.2150780
    • E. Rietzel and G. T. Chen, Improving retrospective sorting of 4D computed tomography data., Med. Phys. 33, 377-379 (2006). 10.1118/1.2150780 (Pubitemid 43183980)
    • (2006) Medical Physics , vol.33 , Issue.2 , pp. 377-379
    • Rietzel, E.1    Chen, G.T.Y.2
  • 7
    • 0034762764 scopus 로고    scopus 로고
    • Determining parameters for respiration-gated radiotherapy
    • DOI 10.1118/1.1406524
    • S. S. Vedam, P. J. Keall, V. R. Kini, and R. Mohan, Determining parameters for respiration-gated radiotherapy., Med. Phys. 28, 2139-2146 (2001). 10.1118/1.1406524 (Pubitemid 32977560)
    • (2001) Medical Physics , vol.28 , Issue.10 , pp. 2139-2146
    • Vedam, S.S.1    Keall, P.J.2    Kini, V.R.3    Mohan, R.4
  • 8
    • 35649001395 scopus 로고    scopus 로고
    • Improvement of the cine-CT based 4D-CT imaging
    • DOI 10.1118/1.2794225
    • T. Pan, X. Sun, and D. Luo, Improvement of the cine-CT based 4D-CT imaging., Med. Phys. 34, 4499-4503 (2007). 10.1118/1.2794225 (Pubitemid 350029671)
    • (2007) Medical Physics , vol.34 , Issue.11 , pp. 4499-4503
    • Pan, T.1    Sun, X.2    Luo, D.3
  • 9
    • 54049105620 scopus 로고    scopus 로고
    • Retrospective analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients
    • 10.1016/j.ijrob2008.06.1937
    • T. Yamamoto, U. Langner, B. W. Loo, Jr., J. Shen, and P. J. Keall, Retrospective analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients., Int. J. Radiat. Oncol., Biol., Phys. 72, 1250-1258 (2008). 10.1016/j.ijrobp.2008.06.1937
    • (2008) Int. J. Radiat. Oncol., Biol., Phys. , vol.72 , pp. 1250-1258
    • Yamamoto, T.1    Langner, U.2    Loo Jr., B.W.3    Shen, J.4    Keall, P.J.5
  • 10
    • 63649084829 scopus 로고    scopus 로고
    • A fully automated non-external marker 4D-CT sorting algorithm using a serial cine scanning protocol
    • 10.1088/0031-9155/54/7/013
    • G. Carnes, S. Gaede, E. Yu, J. Van Dyk, J. Battista, and T. Y. Lee, A fully automated non-external marker 4D-CT sorting algorithm using a serial cine scanning protocol., Phys. Med. Biol. 54, 2049-2066 (2009). 10.1088/0031-9155/54/ 7/013
    • (2009) Phys. Med. Biol. , vol.54 , pp. 2049-2066
    • Carnes, G.1    Gaede, S.2    Yu, E.3    Van Dyk, J.4    Battista, J.5    Lee, T.Y.6
  • 11
    • 34147120474 scopus 로고
    • A note on two problems in connexion with graphs
    • 10.1007/BF01386390
    • E. W. Dijkstra, A note on two problems in connexion with graphs., Numer. Math. 1, 269-271 (1959). 10.1007/BF01386390
    • (1959) Numer. Math. , vol.1 , pp. 269-271
    • Dijkstra, E.W.1
  • 12
    • 58149412516 scopus 로고
    • Weighted kappa: Nominal scale agreement with provision for scaled disagreement or partial credit
    • 10.1037/h0026256
    • J. Cohen, Weighted kappa: Nominal scale agreement with provision for scaled disagreement or partial credit., Psychol. Bull. 70, 213-220 (1968). 10.1037/h0026256
    • (1968) Psychol. Bull. , vol.70 , pp. 213-220
    • Cohen, J.1
  • 13
    • 84965886444 scopus 로고
    • Equivalence of weighted kappa and intraclass correlation coefficient as measures of reliability
    • 10.1177/001316447303300309
    • J. L. Fleiss and J. Cohen, Equivalence of weighted kappa and intraclass correlation coefficient as measures of reliability., Educ. Psychol. Meas. 33, 613-619 (1973). 10.1177/001316447303300309
    • (1973) Educ. Psychol. Meas. , vol.33 , pp. 613-619
    • Fleiss, J.L.1    Cohen, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.