메뉴 건너뛰기




Volumn 14, Issue 1, 2013, Pages 299-304

Dosimetric assessment of a novel metal artifact reduction method in CT images

Author keywords

CT; Dose inaccuracies; IMRT; Metal artifact reduction

Indexed keywords


EID: 84873533236     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v14i1.4027     Document Type: Article
Times cited : (22)

References (12)
  • 1
    • 0034351113 scopus 로고    scopus 로고
    • X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prostheses
    • Zhao S, Robertson DD, Wang G, Whiting B, Bae KT. X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prostheses. IEEE Trans Med Imaging. 2000;19(12):1238-47.
    • (2000) IEEE Trans Med Imaging , vol.19 , Issue.12 , pp. 1238-1247
    • Zhao, S.1    Robertson, D.D.2    Wang, G.3    Whiting, B.4    Bae, K.T.5
  • 2
    • 33746633331 scopus 로고    scopus 로고
    • Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering
    • Bal M, Spies L. Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering. Med Phys. 2006;33(8):2852-59.
    • (2006) Med Phys , vol.33 , Issue.8 , pp. 2852-2859
    • Bal, M.1    Spies, L.2
  • 3
    • 12744273446 scopus 로고    scopus 로고
    • X-ray CT high-density artifact suppression in the presence of bones
    • Wei J, Chen L, Sandison GA, Liang Y, Xu LX. X-ray CT high-density artifact suppression in the presence of bones. Phys Med Biol. 2004;49(24):5407-18.
    • (2004) Phys Med Biol , vol.49 , Issue.24 , pp. 5407-5418
    • Wei, J.1    Chen, L.2    Sandison, G.A.3    Liang, Y.4    Xu, L.X.5
  • 4
    • 49949095531 scopus 로고    scopus 로고
    • Computed tomographic metal artifact reduction for the detection and quantitation of small features near large metallic implants: a comparison of published methods.
    • Rinkel J, Dillon WP, Funk T, Gould R, Prevrhal S. Computed tomographic metal artifact reduction for the detection and quantitation of small features near large metallic implants: a comparison of published methods. J Comput Assist Tomogr. 2008;32(4):621-29.
    • (2008) J Comput Assist Tomogr , vol.32 , Issue.4 , pp. 621-629
    • Rinkel, J.1    Dillon, W.P.2    Funk, T.3    Gould, R.4    Prevrhal, S.5
  • 5
    • 75749108974 scopus 로고    scopus 로고
    • Development and validation of segmentation and interpolation techniques in sinograms for metal artifact suppression in CT
    • Veldkamp WJH, Joemai RMS, van der Molen AJ, Geleijns J. Development and validation of segmentation and interpolation techniques in sinograms for metal artifact suppression in CT. Med Phys. 2010;37(2):620-28.
    • (2010) Med Phys , vol.37 , Issue.2 , pp. 620-628
    • Veldkamp, W.J.H.1    Joemai, R.M.S.2    van der Molen, A.J.3    Geleijns, J.4
  • 6
    • 77958483245 scopus 로고    scopus 로고
    • Reducing metal artifacts in computed tomography caused by hip endoprostheses using a physics-based approach
    • Prell D, Kyriakou Y, Kachelrie M, Kalender WA. Reducing metal artifacts in computed tomography caused by hip endoprostheses using a physics-based approach. Invest Radiol. 2010;45(11):747-54.
    • (2010) Invest Radiol , vol.45 , Issue.11 , pp. 747-754
    • Prell, D.1    Kyriakou, Y.2    Kachelrie, M.3    Kalender, W.A.4
  • 8
    • 79959376217 scopus 로고    scopus 로고
    • Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
    • Bamberg F, Dierks A, Nikolaou K, Reiser MF, Becker CR, Johnson TR. Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation. Eur Radiol. 2011;21(7):1424-29.
    • (2011) Eur Radiol , vol.21 , Issue.7 , pp. 1424-1429
    • Bamberg, F.1    Dierks, A.2    Nikolaou, K.3    Reiser, M.F.4    Becker, C.R.5    Johnson, T.R.6
  • 9
    • 84860137596 scopus 로고    scopus 로고
    • CT metal artifact reduction method correcting for beam hardening and missing projections
    • Verburg J, Seco J. CT metal artifact reduction method correcting for beam hardening and missing projections. Phys Med Biol. 2012;57(9):2803-18.
    • (2012) Phys Med Biol , vol.57 , Issue.9 , pp. 2803-2818
    • Verburg, J.1    Seco, J.2
  • 10
    • 10744226022 scopus 로고    scopus 로고
    • Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63
    • Reft C, Alecu R, Das IJ, et al. Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63. Med Phys. 2003;30(6):1162-82.
    • (2003) Med Phys , vol.30 , Issue.6 , pp. 1162-1182
    • Reft, C.1    Alecu, R.2    Das, I.J.3
  • 11
    • 37549062637 scopus 로고    scopus 로고
    • Dosimetric impact of motion in free-breathing and gated lung radiotherapy: a 4D Monte Carlo study of intrafraction and interfraction effects
    • Seco J, Sharp GC, Wu Z, Gierga D, Buettner F, Paganetti H. Dosimetric impact of motion in free-breathing and gated lung radiotherapy: a 4D Monte Carlo study of intrafraction and interfraction effects. Med Phys. 2008;35(1):356-66.
    • (2008) Med Phys , vol.35 , Issue.1 , pp. 356-366
    • Seco, J.1    Sharp, G.C.2    Wu, Z.3    Gierga, D.4    Buettner, F.5    Paganetti, H.6
  • 12
    • 34047250299 scopus 로고    scopus 로고
    • Conversion of CT numbers into tissue parameters for Monte Carlo dose calculations: a multi-center study
    • Vanderstraeten B, Chin M, Fix M, et al. Conversion of CT numbers into tissue parameters for Monte Carlo dose calculations: a multi-center study. Phys Med Biol. 2007;52(3):539-62.
    • (2007) Phys Med Biol , vol.52 , Issue.3 , pp. 539-562
    • Vanderstraeten, B.1    Chin, M.2    Fix, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.