메뉴 건너뛰기




Volumn 10, Issue 1, 2006, Pages 86-97

Multichannel CT imaging of orthopedic hardware and implants

Author keywords

Bone; CT; Joint prosthesis; Prostheses and implants; X ray computed tomography

Indexed keywords

ARTICLE; ARTIFACT REDUCTION; BONE ATROPHY; BONE PROSTHESIS; COLLIMATOR; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC ACCURACY; DIAGNOSTIC APPROACH ROUTE; DIAGNOSTIC IMAGING; DIAGNOSTIC VALUE; HIP PROSTHESIS; HUMAN; IMAGE INTENSIFIER; IMAGE PROCESSING; IMAGE QUALITY; MULTICHANNEL RECORDER; OPEN REDUCTION; ORTHOPEDIC EQUIPMENT; OSTEOSYNTHESIS; PATIENT ASSESSMENT; POSTOPERATIVE PERIOD; PROSTHESIS FAILURE; PROSTHESIS LOOSENING; RADIOLOGIST; TOTAL HIP PROSTHESIS; EQUIPMENT; HIP; KNEE; METHODOLOGY; PROSTHESES AND ORTHOSES; RADIOGRAPHY; REVIEW; SHOULDER;

EID: 33745929920     PISSN: 10897860     EISSN: 1098898X     Source Type: Journal    
DOI: 10.1055/s-2006-934219     Document Type: Article
Times cited : (60)

References (8)
  • 1
    • 0036210548 scopus 로고    scopus 로고
    • Technical considerations: CT and MR imaging in the postoperative orthopedic patient
    • White LM, Buckwalter KA. Technical considerations: CT and MR imaging in the postoperative orthopedic patient. Semin Musculoskelet Radiol 2002;6:5-17
    • (2002) Semin Musculoskelet Radiol , vol.6 , pp. 5-17
    • White, L.M.1    Buckwalter, K.A.2
  • 2
    • 0022461321 scopus 로고
    • Metallic hip implants: CT with multiplanar reconstruction
    • Fishman EK, Magid D, Robertson DD, et al. Metallic hip implants: CT with multiplanar reconstruction. Radiology 1986;160:675-681
    • (1986) Radiology , vol.160 , pp. 675-681
    • Fishman, E.K.1    Magid, D.2    Robertson, D.D.3
  • 3
    • 0028135654 scopus 로고
    • CT scans through metal scanning technique versus hardware composition
    • Haramati N, Staron RB, Mazel-Sperling K, et al. CT scans through metal scanning technique versus hardware composition. Comput Med Imaging Graph 1994;18:429-434
    • (1994) Comput Med Imaging Graph , vol.18 , pp. 429-434
    • Haramati, N.1    Staron, R.B.2    Mazel-Sperling, K.3
  • 5
    • 0029870637 scopus 로고    scopus 로고
    • Synovial cyst formation complicating total hip arthroplasty: A case report
    • DeFrang RD, Guyer WD, Porter JM, et al. Synovial cyst formation complicating total hip arthroplasty: a case report. Clin Orthop Relat Res 1996;(325):163-167
    • (1996) Clin Orthop Relat Res , vol.325 , pp. 163-167
    • DeFrang, R.D.1    Guyer, W.D.2    Porter, J.M.3
  • 6
    • 0031907145 scopus 로고    scopus 로고
    • Polyethylene wear debris presenting as a retroperitoneal tumor
    • Adelman SC, Urquhart AG, Sondak V, et al. Polyethylene wear debris presenting as a retroperitoneal tumor. Surgery 1998;123:111-112
    • (1998) Surgery , vol.123 , pp. 111-112
    • Adelman, S.C.1    Urquhart, A.G.2    Sondak, V.3
  • 7
    • 0036528661 scopus 로고    scopus 로고
    • Use of helical computed tomography for the assessment of acetabular osteolysis after total hip arthroplasty
    • Puri L, Wixson RL, Stern SH, et al. Use of helical computed tomography for the assessment of acetabular osteolysis after total hip arthroplasty. J Bone Joint Surg Am 2002;84:609-614
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 609-614
    • Puri, L.1    Wixson, R.L.2    Stern, S.H.3
  • 8
    • 0025179416 scopus 로고
    • Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components
    • Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res 1990;(257):107-128
    • (1990) Clin Orthop Relat Res , vol.257 , pp. 107-128
    • Engh, C.A.1    Massin, P.2    Suthers, K.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.