메뉴 건너뛰기




Volumn 26, Issue 1, 2013, Pages 1-4

MR/PET or PET/MRI: Does it matter?

Author keywords

Artifacts; Attenuation correction; Cancer; PET CT; PET MR; Safety

Indexed keywords

ARTIFACT; COMPUTER ASSISTED EMISSION TOMOGRAPHY; COMPUTER ASSISTED TOMOGRAPHY; EQUIPMENT DESIGN; HUMAN; IMAGE PROCESSING; METHODOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; POSITRON EMISSION TOMOGRAPHY; REVIEW; WHOLE BODY IMAGING;

EID: 84873329060     PISSN: 09685243     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10334-012-0365-0     Document Type: Review
Times cited : (11)

References (29)
  • 1
    • 60549083251 scopus 로고    scopus 로고
    • Pre-clinical PET/MR: Technological advances and new perspectives in biomedical research
    • 19194703 10.1007/s00259-009-1078-0
    • Wehrl HF, Judenhofer MS, Wiehr S, Pichler BJ (2009) Pre-clinical PET/MR: technological advances and new perspectives in biomedical research. Eur J Nucl Med Mol Imaging 36(Suppl 1):S56-S68
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.SUPPL. 1
    • Wehrl, H.F.1    Judenhofer, M.S.2    Wiehr, S.3    Pichler, B.J.4
  • 2
    • 77950366807 scopus 로고    scopus 로고
    • PET/MRI: Paving the way for the next generation of clinical multimodality imaging applications
    • 20150252 10.2967/jnumed.109.061853
    • Pichler BJ, Kolb A, Nägele T, Schlemmer HP (2010) PET/MRI: paving the way for the next generation of clinical multimodality imaging applications. J Nucl Med 51(3):333-336
    • (2010) J Nucl Med , vol.51 , Issue.3 , pp. 333-336
    • Pichler, B.J.1    Kolb, A.2    Nägele, T.3    Schlemmer, H.P.4
  • 3
    • 84862836501 scopus 로고    scopus 로고
    • The future of hybrid imaging-part 3: PET/MR, small-animal imaging and beyond
    • 22347950 10.1007/s13244-011-0085-4
    • Beyer T, Freudenberg LS, Czernin J, Townsend DW (2011) The future of hybrid imaging-part 3: PET/MR, small-animal imaging and beyond. Insights Imaging 2(3):235-246
    • (2011) Insights Imaging , vol.2 , Issue.3 , pp. 235-246
    • Beyer, T.1    Freudenberg, L.S.2    Czernin, J.3    Townsend, D.W.4
  • 4
    • 60549087331 scopus 로고    scopus 로고
    • Healthcare costs for new technologies
    • 19104799 10.1007/s00259-008-0975-y
    • Goyen M, Debatin JF (2009) Healthcare costs for new technologies. Eur J Nucl Med Mol Imaging 36(Suppl 1):S139-S143
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.SUPPL. 1
    • Goyen, M.1    Debatin, J.F.2
  • 5
    • 84874109727 scopus 로고    scopus 로고
    • Sequential whole-body PET/MR scanner: Concept, clinical use, and optimisation after two years in the clinic. The manufacturer's perspective
    • Kalemis A, Delattre BM, Heinzer S (2013) Sequential whole-body PET/MR scanner: concept, clinical use, and optimisation after two years in the clinic. The manufacturer's perspective. Magn Reson Mater Phy 26(1):5-23
    • (2013) Magn Reson Mater Phy , vol.26 , Issue.1 , pp. 5-23
    • Kalemis, A.1    Delattre, B.M.2    Heinzer, S.3
  • 6
    • 84874118629 scopus 로고    scopus 로고
    • PET-MR imaging using a tri-modality PET/CT-MR system with a dedicated shuttle in clinical routine
    • Veit-Haibach P, Kuhn FP, Wiesinger F, Delso G, von Schulthess G (2013) PET-MR imaging using a tri-modality PET/CT-MR system with a dedicated shuttle in clinical routine. Magn Reson Mater Phy 26(1):25-35
    • (2013) Magn Reson Mater Phy , vol.26 , Issue.1 , pp. 25-35
    • Veit-Haibach, P.1    Kuhn, F.P.2    Wiesinger, F.3    Delso, G.4    Von Schulthess, G.5
  • 7
    • 0031791001 scopus 로고    scopus 로고
    • Attenuation correction for a combined 3D PET/CT scanner
    • 9800714 10.1118/1.598392 1:STN:280:DyaK1M%2FhslSqtA%3D%3D
    • Kinahan PE, Townsend DW, Beyer T, Sashin D (1998) Attenuation correction for a combined 3D PET/CT scanner. Med Phys 25(10):2046-2053
    • (1998) Med Phys , vol.25 , Issue.10 , pp. 2046-2053
    • Kinahan, P.E.1    Townsend, D.W.2    Beyer, T.3    Sashin, D.4
  • 8
    • 77952095948 scopus 로고    scopus 로고
    • Integrating imaging modalities: What makes sense from a workflow perspective?
    • 10.1007/s00259-009-1378-4
    • von Schulthess GK, Burger C (2010) Integrating imaging modalities: what makes sense from a workflow perspective? Eur J Nucl Med Mol Imaging 37(5):980-990
    • (2010) Eur J Nucl Med Mol Imaging , vol.37 , Issue.5 , pp. 980-990
    • Von Schulthess, G.K.1    Burger, C.2
  • 11
    • 60549089555 scopus 로고    scopus 로고
    • Combined PET/MRI: A new dimension in whole-body oncology imaging?
    • 19104802 10.1007/s00259-008-0951-6
    • Antoch G, Bockisch A (2009) Combined PET/MRI: a new dimension in whole-body oncology imaging? Eur J Nucl Med Mol Imaging 36(Suppl 1):S113-S120
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.SUPPL. 1
    • Antoch, G.1    Bockisch, A.2
  • 12
    • 84861848020 scopus 로고    scopus 로고
    • Oncologic PET/MRI, part 1: Tumors of the brain, head and neck, chest, abdomen, and pelvis
    • 22582048 10.2967/jnumed.112.105338
    • Buchbender C, Heusner TA, Lauenstein TC, Bockisch A, Antoch G (2012) Oncologic PET/MRI, part 1: tumors of the brain, head and neck, chest, abdomen, and pelvis. J Nucl Med 53(6):928-938
    • (2012) J Nucl Med , vol.53 , Issue.6 , pp. 928-938
    • Buchbender, C.1    Heusner, T.A.2    Lauenstein, T.C.3    Bockisch, A.4    Antoch, G.5
  • 13
    • 84864770796 scopus 로고    scopus 로고
    • Oncologic PET/MRI, part 2: Bone tumors, soft-tissue tumors, melanoma, and lymphoma
    • 22782313 10.2967/jnumed.112.109306
    • Buchbender C, Heusner TA, Lauenstein TC, Bockisch A, Antoch G (2012) Oncologic PET/MRI, part 2: bone tumors, soft-tissue tumors, melanoma, and lymphoma. J Nucl Med 53(8):1244-1252
    • (2012) J Nucl Med , vol.53 , Issue.8 , pp. 1244-1252
    • Buchbender, C.1    Heusner, T.A.2    Lauenstein, T.C.3    Bockisch, A.4    Antoch, G.5
  • 17
    • 0027178057 scopus 로고
    • Anatometabolic" tumor imaging: Fusion of FDG PET with CT or MRI to localize foci of increased activity
    • 8315501 1:STN:280:DyaK3szgtFOntA%3D%3D
    • Wahl RL, Quint LE, Cieslak RD, Aisen AM, Koeppe RA, Meyer CR (1993) "Anatometabolic" tumor imaging: fusion of FDG PET with CT or MRI to localize foci of increased activity. J Nucl Med 34(7):1190-1197
    • (1993) J Nucl Med , vol.34 , Issue.7 , pp. 1190-1197
    • Wahl, R.L.1    Quint, L.E.2    Cieslak, R.D.3    Aisen, A.M.4    Koeppe, R.A.5    Meyer, C.R.6
  • 20
    • 60549086399 scopus 로고    scopus 로고
    • Towards quantitative PET/MRI: A review of MR-based attenuation correction techniques
    • 19104810 10.1007/s00259-008-1007-7
    • Hofmann M, Pichler B, Schölkopf B, Beyer T (2009) Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques. Eur J Nucl Med Mol Imaging 36(Suppl 1):S93-S104
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.SUPPL. 1
    • Hofmann, M.1    Pichler, B.2    Schölkopf, B.3    Beyer, T.4
  • 21
    • 84874110199 scopus 로고    scopus 로고
    • Quantitative accuracy of attenuation correction in the Philips Ingenuity TF whole-body PET/MR system: A direct comparison with transmission-based attenuation correction
    • 10.1007/s10334-012-0328-5
    • Schramm G, Langner J, Hofheinz F, Petr J, Beuthien-Baumann B, Platzek I, Steinbach J, Kotzerke J, van den Hoff J (2013) Quantitative accuracy of attenuation correction in the Philips Ingenuity TF whole-body PET/MR system: a direct comparison with transmission-based attenuation correction. Magn Reson Mater Phy 26(1):115-126
    • (2013) Magn Reson Mater Phy , vol.26 , Issue.1 , pp. 115-126
    • Schramm, G.1    Langner, J.2    Hofheinz, F.3    Petr, J.4    Beuthien-Baumann, B.5    Platzek, I.6    Steinbach, J.7    Kotzerke, J.8    Van Den Hoff, J.9
  • 22
  • 23
    • 84874105804 scopus 로고    scopus 로고
    • Does PET/MR in human brain imaging provide optimal registration? A critical reflection
    • Pietrzyk U, Herzog H (2013) Does PET/MR in human brain imaging provide optimal registration? A critical reflection. Magn Reson Mater Phy 26(1):137-147
    • (2013) Magn Reson Mater Phy , vol.26 , Issue.1 , pp. 137-147
    • Pietrzyk, H.1    Herzog, U.2
  • 24
    • 84874117374 scopus 로고    scopus 로고
    • Radiotracers for positron emission tomography imaging
    • Gillings N (2013) Radiotracers for positron emission tomography imaging. Magn Reson Mater Phy 26(1):149-158
    • (2013) Magn Reson Mater Phy , vol.26 , Issue.1 , pp. 149-158
    • Gillings, N.1
  • 25
    • 84874114603 scopus 로고    scopus 로고
    • Physical and organizational provision for installation, regulatory requirements and implementation of a simultaneous hybrid PET/MR-imaging system in an integrated research and clinical setting
    • Sattler B, Jochimsen T, Barthel H, Sommerfeld K, Stumpp P, Hoffmann KT, Gutberlet M, Villringer A, Kahn T, Sabri O (2013) Physical and organizational provision for installation, regulatory requirements and implementation of a simultaneous hybrid PET/MR-imaging system in an integrated research and clinical setting. Magn Reson Mater Phy 26(1):159-171
    • (2013) Magn Reson Mater Phy , vol.26 , Issue.1 , pp. 159-171
    • Sattler, B.1    Jochimsen, T.2    Barthel, H.3    Sommerfeld, K.4    Stumpp, P.5    Hoffmann, K.T.6    Gutberlet, M.7    Villringer, A.8    Kahn, T.9    Sabri, O.10
  • 27
    • 60549100491 scopus 로고    scopus 로고
    • Risks and safety aspects related to PET/MR examinations
    • 19104806 10.1007/s00259-008-0937-4
    • Brix G, Nekolla EA, Nosske D, Griebel J (2009) Risks and safety aspects related to PET/MR examinations. Eur J Nucl Med Mol Imaging 36(Suppl 1):S131-S138
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.SUPPL. 1
    • Brix, G.1    Nekolla, E.A.2    Nosske, D.3    Griebel, J.4
  • 29
    • 84859646398 scopus 로고    scopus 로고
    • 7-T MR - From research to clinical applications?
    • 22102481 10.1002/nbm.1794
    • Moser E, Stahlberg F, Ladd ME, Trattnig S (2012) 7-T MR - from research to clinical applications? NMR Biomed 25(5):695-716
    • (2012) NMR Biomed , vol.25 , Issue.5 , pp. 695-716
    • Moser, E.1    Stahlberg, F.2    Ladd, M.E.3    Trattnig, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.