메뉴 건너뛰기




Volumn 69, Issue 2, 2013, Pages 531-537

Improved partial volume correction for single inversion time arterial spin labeling data

Author keywords

arterial spin labeling; linear trimmed squares; partial volume correction; perfusion MRI

Indexed keywords

BLOOD; CEREBROSPINAL FLUID; HEMODYNAMICS; REGRESSION ANALYSIS; TISSUE;

EID: 84872938475     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24279     Document Type: Article
Times cited : (34)

References (18)
  • 2
    • 0033937960 scopus 로고    scopus 로고
    • 1-based tissue identification
    • DOI 10.1002/1522-2594(200007)44:1<137::AID-MRM20>3.0.CO;2-R
    • Luh WM, Wong EC, Bandettini PA, Ward BD, Hyde JS,. Comparison of simultaneously measured perfusion and BOLD signal increases during brain activation with T(1)-based tissue identification. Magn Reson Med 2000; 44: 137-143. (Pubitemid 30439849)
    • (2000) Magnetic Resonance in Medicine , vol.44 , Issue.1 , pp. 137-143
    • Luh, W.-M.1    Wong, E.C.2    Bandettini, P.A.3    Ward, B.D.4    Hyde, J.S.5
  • 3
    • 0036338610 scopus 로고    scopus 로고
    • Experimental design and the relative sensitivity of BOLD and perfusion fMRI
    • DOI 10.1006/nimg.2001.0990
    • Aguirre GK, Detre JA, Zarahn E, Alsop DC,. Experimental design and the relative sensitivity of BOLD and perfusion fMRI. Neuroimage 2002; 15: 488-500. (Pubitemid 34852517)
    • (2002) NeuroImage , vol.15 , Issue.3 , pp. 488-500
    • Aguirre, G.K.1    Detre, J.A.2    Zarahn, E.3    Alsop, D.C.4
  • 5
    • 77949708300 scopus 로고    scopus 로고
    • Reliability and precision of pseudo-continuous arterial spin labeling perfusion MRI on 3.0 T and comparison with 15O-water PET in elderly subjects at risk for Alzheimer's disease
    • Xu G, Rowley HA, Wu G, Alsop DC, Shankaranarayanan A, Dowling M, Christian BT, Oakes TR, Johnson SC,. Reliability and precision of pseudo-continuous arterial spin labeling perfusion MRI on 3.0 T and comparison with 15O-water PET in elderly subjects at risk for Alzheimer's disease. NMR Biomed 2010; 23: 286-293.
    • (2010) NMR Biomed , vol.23 , pp. 286-293
    • Xu, G.1    Rowley, H.A.2    Wu, G.3    Alsop, D.C.4    Shankaranarayanan, A.5    Dowling, M.6    Christian, B.T.7    Oakes, T.R.8    Johnson, S.C.9
  • 6
    • 79955029790 scopus 로고    scopus 로고
    • Potentials and challenges for arterial spin labeling in pharmacological magnetic resonance imaging
    • Wang DJ, Chen Y, Fernandez-Seara MA, Detre JA,. Potentials and challenges for arterial spin labeling in pharmacological magnetic resonance imaging. J Pharmacol Exp Ther 2011; 337: 359-366.
    • (2011) J Pharmacol Exp Ther , vol.337 , pp. 359-366
    • Wang, D.J.1    Chen, Y.2    Fernandez-Seara, M.A.3    Detre, J.A.4
  • 8
    • 57149093221 scopus 로고    scopus 로고
    • Regression algorithm correcting for partial volume effects in arterial spin labeling MRI
    • Asllani I, Borogovac A, Brown TR,. Regression algorithm correcting for partial volume effects in arterial spin labeling MRI. Magn Reson Med 2008; 60: 1362-1371.
    • (2008) Magn Reson Med , vol.60 , pp. 1362-1371
    • Asllani, I.1    Borogovac, A.2    Brown, T.R.3
  • 11
    • 84950968334 scopus 로고
    • Least median of squares regression
    • Rousseeuw PJ,. Least median of squares regression. J Am Stat Assoc 1984; 79: 871-880.
    • (1984) J Am Stat Assoc , vol.79 , pp. 871-880
    • Rousseeuw, P.J.1
  • 14
    • 13844298168 scopus 로고    scopus 로고
    • Pattern of cerebral hypoperfusion in Alzheimer disease and mild cognitive impairment measured with arterial spin-labeling MR imaging: Initial experience
    • DOI 10.1148/radiol.2343040197
    • Johnson NA, Jahng GH, Weiner MW, Miller BL, Chui HC, Jagust WJ, Gorno-Tempini ML, Schuff N,. Pattern of cerebral hypoperfusion in Alzheimer disease and mild cognitive impairment measured with arterial spin-labeling MR imaging: initial experience. Radiology 2005; 234: 851-859. (Pubitemid 40250829)
    • (2005) Radiology , vol.234 , Issue.3 , pp. 851-859
    • Johnson, N.A.1    Jahng, G.-H.2    Weiner, M.W.3    Miller, B.L.4    Chui, H.C.5    Jagust, W.J.6    Gorno-Tempini, M.L.7    Schuff, N.8
  • 15
    • 84857204645 scopus 로고    scopus 로고
    • A k-space sharing 3D GRASE pseudo-continuous ASL method for whole-brain resting-state functional connectivity
    • Liang X, Tournier JD, Masterton R, Connelly A, Calamante F,. A k-space sharing 3D GRASE pseudo-continuous ASL method for whole-brain resting-state functional connectivity. Int J Imaging Syst Technol 2012; 22: 37-43.
    • (2012) Int J Imaging Syst Technol , vol.22 , pp. 37-43
    • Liang, X.1    Tournier, J.D.2    Masterton, R.3    Connelly, A.4    Calamante, F.5
  • 17
    • 22744437068 scopus 로고    scopus 로고
    • Efficiency of inversion pulses for background suppressed arterial spin labeling
    • DOI 10.1002/mrm.20556
    • Garcia DM, Duhamel G, Alsop DC,. Efficiency of inversion pulses for background suppressed arterial spin labeling. Magn Reson Med 2005; 54: 366-372. (Pubitemid 41033553)
    • (2005) Magnetic Resonance in Medicine , vol.54 , Issue.2 , pp. 366-372
    • Garcia, D.M.1    Duhamel, G.2    Alsop, D.C.3
  • 18
    • 84872974223 scopus 로고    scopus 로고
    • Achieving late inflow delay in pseudo-CASL 3D GRASE using a hybridized labeling and background suppression scheme
    • Toronto, Canada
    • Fernandez-Seara M, Wang J, Feinberg DA, Detre JA,. Achieving late inflow delay in pseudo-CASL 3D GRASE using a hybridized labeling and background suppression scheme. In Proceedings of the 16th Annual Meeting of ISMRM, Toronto, Canada, 2008. p. 3343.
    • (2008) Proceedings of the 16th Annual Meeting of ISMRM , pp. 3343
    • Fernandez-Seara, M.1    Wang, J.2    Feinberg, D.A.3    Detre, J.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.