메뉴 건너뛰기




Volumn 46, Issue 3, 2013, Pages 612-614

Tekscan pressure sensor output changes in the presence of liquid exposure

Author keywords

Knee; Orthopaedics; Pressure Sensing Film; Sports Medicine; Tekscan

Indexed keywords

BIOMEDICAL RESEARCH; CALIBRATED PRESSURES; CLINICAL PRACTICES; COMPRESSIVE LOADS; CONTROLLED ENVIRONMENT; DRY ENVIRONMENT; HUMID AIR; INSTRON; KNEE; LIQUID SATURATION; MOIST ENVIRONMENT; PRESSURE SENSING; SALINE SOLUTIONS; STEADY STATE; TEKSCAN; TENSILE TESTING MACHINES;

EID: 84872595234     PISSN: 00219290     EISSN: 18732380     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2012.09.033     Document Type: Article
Times cited : (45)

References (14)
  • 2
    • 84868191587 scopus 로고    scopus 로고
    • Proud osteochondral autograft versus synthetic plugs-Contact pressures with cyclical loading in a bovine knee model
    • April 11 (Epub ahead of print)
    • Elguizaoui, S., Flanigan, D.C., Harris, J.D., Parsons, E., Litsky, A.S., Siston, R.A., 2012. Proud osteochondral autograft versus synthetic plugs-Contact pressures with cyclical loading in a bovine knee model. Knee, April 11 (Epub ahead of print).
    • (2012) Knee
    • Elguizaoui, S.1    Flanigan, D.C.2    Harris, J.D.3    Parsons, E.4    Litsky, A.S.5    Siston, R.A.6
  • 3
    • 78649670025 scopus 로고    scopus 로고
    • The effects of lesion size and location on subchondral bone contact in experimental knee articular cartilage defects in a bovine model
    • Flanigan D.C., Harris J.D., Brockmeier P.M., Siston R.A. The effects of lesion size and location on subchondral bone contact in experimental knee articular cartilage defects in a bovine model. Arthroscopy 2010, 26(12):1655-1661.
    • (2010) Arthroscopy , vol.26 , Issue.12 , pp. 1655-1661
    • Flanigan, D.C.1    Harris, J.D.2    Brockmeier, P.M.3    Siston, R.A.4
  • 4
    • 84858290403 scopus 로고    scopus 로고
    • Effects of kneeling on tibiofemoral contact pressure and area in posterior cruciate-retaining and posterior cruciate-sacrificing total knee arthroplasty
    • Hofer J.K., Gejo R., McGarry M.H., Lee T.Q. Effects of kneeling on tibiofemoral contact pressure and area in posterior cruciate-retaining and posterior cruciate-sacrificing total knee arthroplasty. Journal of Arthroplasty 2012, 27(4):620-624.
    • (2012) Journal of Arthroplasty , vol.27 , Issue.4 , pp. 620-624
    • Hofer, J.K.1    Gejo, R.2    McGarry, M.H.3    Lee, T.Q.4
  • 9
    • 34948830984 scopus 로고    scopus 로고
    • Dehydration rates of meniscus and articular cartilage in vitro using a fast and accurate laser-based coordinate digitizing system
    • Pham A., Hull M.L. Dehydration rates of meniscus and articular cartilage in vitro using a fast and accurate laser-based coordinate digitizing system. Journal of Biomechanics 2007, 40(14):3223-3229.
    • (2007) Journal of Biomechanics , vol.40 , Issue.14 , pp. 3223-3229
    • Pham, A.1    Hull, M.L.2
  • 10
    • 78049471164 scopus 로고    scopus 로고
    • Lateral ligament repair and reconstruction restore neither contact mechanics of the ankle joint nor motion patterns of the hindfoot
    • Prisk V.R., Imhauser C.W., O'Loughlin P.F., Kennedy J.G. Lateral ligament repair and reconstruction restore neither contact mechanics of the ankle joint nor motion patterns of the hindfoot. Journal of Bone and Joint Surgery, American Volume 2010, 92(14):2375-2386.
    • (2010) Journal of Bone and Joint Surgery, American Volume , vol.92 , Issue.14 , pp. 2375-2386
    • Prisk, V.R.1    Imhauser, C.W.2    O'Loughlin, P.F.3    Kennedy, J.G.4
  • 11
    • 71849086006 scopus 로고    scopus 로고
    • Effect of repair of radial tears at the root of the posterior horn of the medial meniscus with the pullout suture technique: a biomechanical study using porcine knees
    • Seo J.H., Li G., Shetty G.M., Kim J.H., Bae J.H., Jo M.L., Kim J.S., Lee S.J., Nha K.W. Effect of repair of radial tears at the root of the posterior horn of the medial meniscus with the pullout suture technique: a biomechanical study using porcine knees. Arthroscopy 2009, 25(11):1281-1287.
    • (2009) Arthroscopy , vol.25 , Issue.11 , pp. 1281-1287
    • Seo, J.H.1    Li, G.2    Shetty, G.M.3    Kim, J.H.4    Bae, J.H.5    Jo, M.L.6    Kim, J.S.7    Lee, S.J.8    Nha, K.W.9
  • 12
    • 77951800839 scopus 로고    scopus 로고
    • The influence of malrotation of the femoral component in total knee replacement on the mechanics of patellofemoral contact during gait: an in vitro biomechanical study
    • Verlinden C., Uvin P., Labey L., Luyckx J.P., Bellemans J., Vandenneucker H. The influence of malrotation of the femoral component in total knee replacement on the mechanics of patellofemoral contact during gait: an in vitro biomechanical study. Journal of Bone and Joint Surgery, British Volume 2010, 92(5):737-742.
    • (2010) Journal of Bone and Joint Surgery, British Volume , vol.92 , Issue.5 , pp. 737-742
    • Verlinden, C.1    Uvin, P.2    Labey, L.3    Luyckx, J.P.4    Bellemans, J.5    Vandenneucker, H.6
  • 14
    • 0032189669 scopus 로고    scopus 로고
    • Effects of inserting a pressensor film into articular joints on the actual contact mechanics
    • Wu J.Z., Herzog W., Epstein M. Effects of inserting a pressensor film into articular joints on the actual contact mechanics. Journal of Biomechanical Engineering 1998, 120(5):655-659.
    • (1998) Journal of Biomechanical Engineering , vol.120 , Issue.5 , pp. 655-659
    • Wu, J.Z.1    Herzog, W.2    Epstein, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.