메뉴 건너뛰기




Volumn 120, Issue 5, 1998, Pages 655-659

Effects of inserting a pressensor film into articular joints on the actual contact mechanics

Author keywords

[No Author keywords available]

Indexed keywords

CARTILAGE; ELASTICITY; FINITE ELEMENT METHOD; JOINTS (ANATOMY); PHOTOGRAPHIC FILMS; PRESSURE MEASUREMENT;

EID: 0032189669     PISSN: 01480731     EISSN: 15288951     Source Type: Journal    
DOI: 10.1115/1.2834758     Document Type: Article
Times cited : (108)

References (15)
  • 2
    • 0024110520 scopus 로고
    • Contact stress aberrations following imprecise reduction of simple tibial plateau fractures
    • Brown, T. D., Anderson, D. D., Nepola, J. V., Singerman, R. J., Pederson, D. R., and Brand, R. A., 1988, “Contact stress aberrations following imprecise reduction of simple tibial plateau fractures,” J. Orthopaedic Res., 6:851-862.
    • (1988) J. Orthopaedic Res , vol.6 , pp. 851-862
    • Brown, T.D.1    Erson, D.D.2    Nepola, J.V.3    Singerman, R.J.4    Pederson, D.R.5    Brand, R.A.6
  • 4
    • 0019256214 scopus 로고
    • The contact area and pressure distribution of the knee
    • Fukubayashi, T., and Kurosawa, H., 1980, “The contact area and pressure distribution of the knee,” Acta Orthopaedica Scandinavica, 51:871-879.
    • (1980) Acta Orthopaedica Scandinavica , vol.51 , pp. 871-879
    • Fukubayashi, T.1    Kurosawa, H.2
  • 5
    • 0026911047 scopus 로고
    • Contact stress gradient detection limits of pressensor film
    • Hale, J. E., and Brown, T. D., 1992, “Contact stress gradient detection limits of pressensor film,” ASME Journal of Biomechanical Engineering, 114:352-357.
    • (1992) ASME Journal of Biomechanical Engineering , vol.114 , pp. 352-357
    • Hale, J.E.1    Brown, T.D.2
  • 6
    • 0003627982 scopus 로고    scopus 로고
    • Hibbitt, Karlsson and Sorensen, Inc., Pawtucket, RI
    • HKS, 1996, ABAQUS Manual (version 5.5), Hibbitt, Karlsson and Sorensen, Inc., Pawtucket, RI.
    • (1996) ABAQUS Manual (Version 5.5)
  • 7
    • 0024053921 scopus 로고
    • Contact pressures in chondromalacia patellar and the effects of capsular reconstructive procedures
    • Huberti, H. H., and Hayes, W. C., 1988, “Contact pressures in chondromalacia patellar and the effects of capsular reconstructive procedures,” J. Orthopaedic Res., 6:499-508.
    • (1988) J. Orthopaedic Res , vol.6 , pp. 499-508
    • Huberti, H.H.1    Hayes, W.C.2
  • 8
    • 0029395006 scopus 로고
    • An analytical model to study blunt impact response of the rabbit P-F joint
    • Li, X., Haut, R. C., and Altiero, N. J., 1995, “An analytical model to study blunt impact response of the rabbit P-F joint,” ASME Journal of Biomechanical Engineering, 117:485-491.
    • (1995) ASME Journal of Biomechanical Engineering , vol.117 , pp. 485-491
    • Li, X.1    Haut, R.C.2    Altiero, N.J.3
  • 10
    • 0029326663 scopus 로고
    • Spatial and pressure resolution of Fuji pressure-sensitive film
    • Liggins, A. B., Hardie, W. R., and Finlay, J. B., 1995b, “Spatial and pressure resolution of Fuji pressure-sensitive film,” Experimental Mechanics, 35:166-173.
    • (1995) Experimental Mechanics , vol.35 , pp. 166-173
    • Liggins, A.B.1    Hardie, W.R.2    Finlay, J.B.3
  • 11
    • 0029307152 scopus 로고
    • Sealing Fuji prescale pressure sensitive film for protection against fluid damage: The effect on its response
    • Liggins, A. B., Surry, K., and Finlay, J. B., 1995c, “Sealing Fuji prescale pressure sensitive film for protection against fluid damage: the effect on its response,” Strain, 31:57-62.
    • (1995) Strain , vol.31 , pp. 57-62
    • Liggins, A.B.1    Surry, K.2    Finlay, J.B.3
  • 12
    • 0020611450 scopus 로고
    • Load-bearing characteristics of lumbar facets in normal and surgically altered spinal segments
    • Lorenz, M., Patwardhem, A., and Vanderby, R., 1983, “Load-bearing characteristics of lumbar facets in normal and surgically altered spinal segments,” Spine, 8:122-130.
    • (1983) Spine , vol.8 , pp. 122-130
    • Lorenz, M.1    Patwardhem, A.2    Vanderby, R.3
  • 14
    • 0023313719 scopus 로고
    • Quantitation of pressure sensitive film using digital image scanning
    • Singerman, R. J., Pederson, D. R., and Brown, T. D., 1987, “Quantitation of pressure sensitive film using digital image scanning,” Experimental Mechanics, 27:99-105.
    • (1987) Experimental Mechanics , vol.27 , pp. 99-105
    • Singerman, R.J.1    Pederson, D.R.2    Brown, T.D.3
  • 15
    • 0022384819 scopus 로고
    • Changes in tibiotalar joint contact areas following experimentally induced tibial angular deformities
    • Tarr, R. R., Resnick, C. T., Wagner, K. S., and Sarmiento, A., 1985, “Changes in tibiotalar joint contact areas following experimentally induced tibial angular deformities,” Clinical Orthopaedics, 199:72-78.
    • (1985) Clinical Orthopaedics , vol.199 , pp. 72-78
    • Tarr, R.R.1    Resnick, C.T.2    Wagner, K.S.3    Sarmiento, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.