메뉴 건너뛰기




Volumn 38, Issue 6, 2012, Pages 706-712

Accuracy of a newly developed cone-beam computerized tomography-aided surgical guidance system for dental implant placement: An ex vivo study

Author keywords

Computer aided surgery; Cone beam computerized tomography (CBCT); Dental implant; Stereolithography; Surgical guide

Indexed keywords

ARTICLE; CADAVER; COMPUTER ASSISTED SURGERY; COMPUTER PROGRAM; CONE BEAM COMPUTED TOMOGRAPHY; EDENTULOUSNESS; HUMAN; IMAGE PROCESSING; MANDIBLE; MEDICAL PHOTOGRAPHY; METHODOLOGY; RADIOGRAPHY; TOOTH IMPLANTATION; VALIDATION STUDY;

EID: 84872513497     PISSN: 01606972     EISSN: 15481336     Source Type: Journal    
DOI: 10.1563/AAID-JOI-D-11-00062     Document Type: Article
Times cited : (3)

References (28)
  • 1
    • 68949085280 scopus 로고    scopus 로고
    • Cone-beam CT for preoperative implant planning in the posterior mandible: Visibility of anatomical landmarks
    • Lofthag-Hansen S, Gröndahl K, Ekestubbe A. Cone-beam CT for preoperative implant planning in the posterior mandible: visibility of anatomical landmarks. Clin Implant Dent Relat Res. 2009; 1:246-255.
    • (2009) Clin Implant Dent Relat Res , vol.1 , pp. 246-255
    • Lofthag-Hansen, S.1    Gröndahl, K.2    Ekestubbe, A.3
  • 2
    • 67650889147 scopus 로고    scopus 로고
    • Bone quality assessment based on cone beam computed tomography imaging
    • Hua Y, Nackaerts O, Duyck J, Maes F, Jacobs R. Bone quality assessment based on cone beam computed tomography imaging. Clin Oral Implant Res. 2009;20:767-771.
    • (2009) Clin Oral Implant Res , vol.20 , pp. 767-771
    • Hua, Y.1    Nackaerts, O.2    Duyck, J.3    Maes, F.4    Jacobs, R.5
  • 3
    • 67649202168 scopus 로고    scopus 로고
    • The use of a computerized tomography-based software program with a flapless surgical technique in implant dentistry: A case report
    • Terzioǧlu H, Akkaya M, Ozan O. The use of a computerized tomography-based software program with a flapless surgical technique in implant dentistry: a case report. Int J Oral Maxillofac Implants. 2009;24:137-142.
    • (2009) Int J Oral Maxillofac Implants , vol.24 , pp. 137-142
    • Terzioǧlu, H.1    Akkaya, M.2    Ozan, O.3
  • 4
    • 84861827126 scopus 로고    scopus 로고
    • Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: A review of the literature
    • D'haese J, van de Velde T, Komiyama A, Hultin M, de Bruyn H. Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature. Clin Implant Dent Relat Res. 2012;14:321-335.
    • (2012) Clin Implant Dent Relat Res , vol.14 , pp. 321-335
    • D'haese, J.1    Van De Velde, T.2    Komiyama, A.3    Hultin, M.4    De Bruyn, H.5
  • 5
    • 34548077180 scopus 로고    scopus 로고
    • Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: A pilot study
    • Van Assche N, van Steenberghe D, Guerrero ME, et al. Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: a pilot study. J Clin Periodontol. 2007;34:816-821.
    • (2007) J Clin Periodontol , vol.34 , pp. 816-821
    • Van Assche, N.1    Van Steenberghe, D.2    Guerrero, M.E.3
  • 6
    • 70249128672 scopus 로고    scopus 로고
    • Accuracy of a computerized tomography-guided template-assisted implant placement system: An in vitro study
    • Horwitz J, Zuabi O, Machtei EE. Accuracy of a computerized tomography-guided template-assisted implant placement system: an in vitro study. Clin Oral Implant Res. 2009;20:1156-1162.
    • (2009) Clin Oral Implant Res , vol.20 , pp. 1156-1162
    • Horwitz, J.1    Zuabi, O.2    MacHtei, E.E.3
  • 7
    • 84864506897 scopus 로고    scopus 로고
    • Accuracy of virtually planned and template guided implant surgery on edentate patients
    • May 11, doi: 10.1111/j.1708-8208.2010.00285.x
    • Pettersson A, Komiyama A, Hultin M, Nasstrom K, Klinge B. Accuracy of virtually planned and template guided implant surgery on edentate patients. Clin Implant Dent Relat Res May 11, 2010. doi: 10.1111/j.1708-8208.2010.00285.x.
    • Clin Implant Dent Relat Res , pp. 2010
    • Pettersson, A.1    Komiyama, A.2    Hultin, M.3    Nasstrom, K.4    Klinge, B.5
  • 8
    • 49149088692 scopus 로고    scopus 로고
    • Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: Clinical data from 94 implants
    • Ersoy AE, Türkyilmaz I, Ozan O, McGlumphy EA. Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants. J Periodontol. 2008;79:1339-1345.
    • (2008) J Periodontol , vol.79 , pp. 1339-1345
    • Ersoy, A.E.1    Türkyilmaz, I.2    Ozan, O.3    McGlumphy, E.A.4
  • 9
    • 33747109599 scopus 로고    scopus 로고
    • Prosthetically directed implant placement using computer software to ensure precise placement and predictable prosthetic outcomes. Part 2: Rapid-prototype medical modeling and stereolithographic drilling guides requiring bone exposure
    • Rosenfeld AL, Mandelaris GA, Tardieu PB. Prosthetically directed implant placement using computer software to ensure precise placement and predictable prosthetic outcomes. Part 2: Rapid-prototype medical modeling and stereolithographic drilling guides requiring bone exposure. Int J Periodont Restor Dent, 2006; 26:347-353.
    • (2006) Int J Periodont Restor Dent , vol.26 , pp. 347-353
    • Rosenfeld, A.L.1    Mandelaris, G.A.2    Tardieu, P.B.3
  • 10
    • 67649202168 scopus 로고    scopus 로고
    • The use of a computerized tomography-based software program with a flapless surgical technique in implant dentistry: A case report
    • Terzioǧlu H, Akkaya M, Ozan O. The use of a computerized tomography-based software program with a flapless surgical technique in implant dentistry: a case report. Int J Oral Maxillofac Implants. 2009;24:137-142.
    • (2009) Int J Oral Maxillofac Implants , vol.24 , pp. 137-142
    • Terzioǧlu, H.1    Akkaya, M.2    Ozan, O.3
  • 11
    • 49349087499 scopus 로고    scopus 로고
    • Using computer-guided implantology in flapless implant surgery of a maxilla: A clinical report
    • Azari A, Nikzad S, Kabiri A. Using computer-guided implantology in flapless implant surgery of a maxilla: a clinical report. J Oral Rehabil. 2008;35:690-694.
    • (2008) J Oral Rehabil , vol.35 , pp. 690-694
    • Azari, A.1    Nikzad, S.2    Kabiri, A.3
  • 12
    • 33646245182 scopus 로고    scopus 로고
    • Effect of flapless surgery on pain experienced in implant placement using an imageguided system
    • Fortin T, Bosson JL, Isidori M, Blanchet E. Effect of flapless surgery on pain experienced in implant placement using an imageguided system. Int J Oral Maxillofac Implants. 2006;21:298-304.
    • (2006) Int J Oral Maxillofac Implants , vol.21 , pp. 298-304
    • Fortin, T.1    Bosson, J.L.2    Isidori, M.3    Blanchet, E.4
  • 13
    • 61649118441 scopus 로고    scopus 로고
    • Implant placement accuracy when using stereolithographic template as a surgical guide: Preliminary results
    • Al-Harbi SA, Sun AYT. Implant placement accuracy when using stereolithographic template as a surgical guide: preliminary results. Implant Dent. 2009;18:46-51.
    • (2009) Implant Dent , vol.18 , pp. 46-51
    • Al-Harbi, S.A.1    Sun, A.Y.T.2
  • 14
    • 0036653031 scopus 로고    scopus 로고
    • Accuracy of reformatted CT image for measuring the pre-implant site: Analysis of the image distorsion related to the gantry angle change
    • Choi SC, Ann CH, Choi HM, Heo MS, Lee SS. Accuracy of reformatted CT image for measuring the pre-implant site: analysis of the image distorsion related to the gantry angle change. Dentomaxillofac Radiol. 2002;31:273-277.
    • (2002) Dentomaxillofac Radiol , vol.31 , pp. 273-277
    • Choi, S.C.1    Ann, C.H.2    Choi, H.M.3    Heo, M.S.4    Lee, S.S.5
  • 15
    • 33644639722 scopus 로고    scopus 로고
    • Clinical applications of cone-beam computed tomography in dental practice
    • Scarfe WC, Farman AG, Sukovic P. Clinical applications of cone-beam computed tomography in dental practice. J Can Dent Assoc. 2006;72:75-80.
    • (2006) J Can Dent Assoc , vol.72 , pp. 75-80
    • Scarfe, W.C.1    Farman, A.G.2    Sukovic, P.3
  • 16
    • 52049117425 scopus 로고    scopus 로고
    • What is cone-beam CT and how does it work?
    • Scarfe WC, Farman AG. What is cone-beam CT and how does it work? Dent Clin North Am. 2008;52:707-730.
    • (2008) Dent Clin North Am , vol.52 , pp. 707-730
    • Scarfe, W.C.1    Farman, A.G.2
  • 17
    • 77952683115 scopus 로고    scopus 로고
    • Essentials of maxillofacial cone beam computed tomography
    • Scarfe WC, Farman AG, Levin MD, Gane D. Essentials of maxillofacial cone beam computed tomography. Alpha Omegan. 2010;103:62-67.
    • (2010) Alpha Omegan , vol.103 , pp. 62-67
    • Scarfe, W.C.1    Farman, A.G.2    Levin, M.D.3    Gane, D.4
  • 19
    • 0026952014 scopus 로고
    • Digital radiology for implant treatment planning and evaluation
    • Jeffcoat MK. Digital radiology for implant treatment planning and evaluation. Dentomaxillofac Radiol. 1992;21:203-207.
    • (1992) Dentomaxillofac Radiol , vol.21 , pp. 203-207
    • Jeffcoat, M.K.1
  • 20
    • 0026145458 scopus 로고
    • Radiographicprosthetic planning of the surgical phase of the treatment of edentulism by osseointegrated implants: An in vitro study
    • Modica F, Fava C, Benech A, Preti G. Radiographicprosthetic planning of the surgical phase of the treatment of edentulism by osseointegrated implants: an in vitro study. J Prosthet Dent. 1991;65:541-546.
    • (1991) J Prosthet Dent , vol.65 , pp. 541-546
    • Modica, F.1    Fava, C.2    Benech, A.3    Preti, G.4
  • 21
    • 19044400459 scopus 로고    scopus 로고
    • Clinical application of stereolithographic surgical guides for implant placement: Preliminary results
    • Di Giacomo GA, Cury PR, de Araujo NS, Sendyk WR, Sendyk CL. Clinical application of stereolithographic surgical guides for implant placement: preliminary results. J Periodontol. 2005;76:503-507.
    • (2005) J Periodontol , vol.76 , pp. 503-507
    • Di Giacomo, G.A.1    Cury, P.R.2    De Araujo, N.S.3    Sendyk, W.R.4    Sendyk, C.L.5
  • 22
    • 43049114556 scopus 로고    scopus 로고
    • The use of CT scan based planning for oral rehabilitation by means of implants and its transfer to the surgical field: A critical review on accuracy
    • Vercruyssen M, Jacobs R, Van Assche N, van Steenberghe D. The use of CT scan based planning for oral rehabilitation by means of implants and its transfer to the surgical field: a critical review on accuracy. J Oral Rehabil. 2008;6:454-474.
    • (2008) J Oral Rehabil , vol.6 , pp. 454-474
    • Vercruyssen, M.1    Jacobs, R.2    Van Assche, N.3    Van Steenberghe, D.4
  • 23
    • 77649199482 scopus 로고    scopus 로고
    • Accuracy of two stereolithographic guide systems for computer-aided implant placement: A computed tomography-based clinical comparative study
    • Arisan V, Karabuda C, Ozdemir T. Accuracy of two stereolithographic guide systems for computer-aided implant placement: a computed tomography-based clinical comparative study. J Periodontol. 2008;81:43-51.
    • (2008) J Periodontol , vol.81 , pp. 43-51
    • Arisan, V.1    Karabuda, C.2    Ozdemir, T.3
  • 24
    • 68549115350 scopus 로고    scopus 로고
    • A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry
    • Schneider D, Marquardt P, Zwahlen M, Jung RD. A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry. Clin Oral Implant Res. 2009;20(suppl 4):73-86.
    • (2009) Clin Oral Implant Res , vol.20 , Issue.SUPPL. 4 , pp. 73-86
    • Schneider, D.1    Marquardt, P.2    Zwahlen, M.3    Jung, R.D.4
  • 25
  • 27
    • 44949184646 scopus 로고    scopus 로고
    • Evaluation of the accuracy of three different computer-aided surgery systems in dental implantology: Optical tracking vs. stereolithographic splint systems
    • Ruppin J, Popovic A, Strauss M, Spüntrup E, Steiner A, Stoll C. Evaluation of the accuracy of three different computer-aided surgery systems in dental implantology: optical tracking vs. stereolithographic splint systems. Clin Oral Implants Res. 2008;19: 709-716.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 709-716
    • Ruppin, J.1    Popovic, A.2    Strauss, M.3    Spüntrup, E.4    Steiner, A.5    Stoll, C.6
  • 28
    • 34548077180 scopus 로고    scopus 로고
    • Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: A pilot study
    • Van Assche N, van Steenberghe D, Guerrero ME, et al. Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: a pilot study. J Clin Periodontol. 2007;34:816-821.
    • (2007) J Clin Periodontol , vol.34 , pp. 816-821
    • Van Assche, N.1    Van Steenberghe, D.2    Guerrero, M.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.