메뉴 건너뛰기




Volumn 36, Issue 5, 2012, Pages 1096-1104

Comparison of breast augmentation incisions and common complications

Author keywords

Breast augmentation; Breast augmentation complications; Breast augmentation incision; Capsular contracture

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; BREAST AUGMENTATION; COMPARATIVE STUDY; FEMALE; HUMAN; METHODOLOGY; MIDDLE AGED; POSTOPERATIVE COMPLICATION; REOPERATION; RETROSPECTIVE STUDY; STATISTICS;

EID: 84872292446     PISSN: 0364216X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00266-012-9918-x     Document Type: Article
Times cited : (69)

References (48)
  • 1
    • 77957661933 scopus 로고    scopus 로고
    • Cosmetic Surgery National Databank Statistics 2 Nov 2011
    • Cosmetic Surgery National Databank Statistics (2010) American Society for Aesthetic Plastic Surgery. http://www.surgery.org/ sites/default/files/ Stats2010-1.pdf. Accessed 2 Nov 2011
    • (2010) American Society for Aesthetic Plastic Surgery.
  • 3
    • 0015849063 scopus 로고
    • Breast augmentation: The trans-axillary approach
    • Hoehler H (1973) Breast augmentation: the trans-axillary approach. Br J Plast Surg 26:371
    • (1973) Br J Plast Surg , vol.26 , pp. 371
    • Hoehler, H.1
  • 4
    • 0015875365 scopus 로고
    • A periareolar incision for augmentation mammaplasty
    • Jones FR, Taura AP (1973) A periareolar incision for augmentation mammaplasty. Plast Reconstr Surg 51(6):641-644
    • (1973) Plast Reconstr Surg , vol.51 , Issue.6 , pp. 641-644
    • Jones, F.R.1    Taura, A.P.2
  • 5
    • 0015975829 scopus 로고
    • Augmentation mammaplasty using a non-inflatable prosthesis through a circum-areolar incision
    • McKinney P, Shedbalker AR (1974) Augmentation mammaplasty using a non-inflatable prosthesis through a circum-areolar incision. Br J Plast Surg 27(1):35-38
    • (1974) Br J Plast Surg , vol.27 , Issue.1 , pp. 35-38
    • McKinney, P.1    Shedbalker, A.R.2
  • 6
    • 56849107592 scopus 로고    scopus 로고
    • The transaxillary approach to breast augmentation
    • Pacella SJ, Codner MA (2009) The transaxillary approach to breast augmentation. Clin Plast Surg 36(1):49-61, vi
    • (2009) Clin Plast Surg , vol.36 , Issue.1 , pp. 49-61
    • Pacella, S.J.1    Codner, M.A.2
  • 7
    • 34547342073 scopus 로고    scopus 로고
    • Five critical decisions in breast augmentation using five measurements in 5 minutes: The high five decision process
    • Tebbetts J, Adams W (2006) Five critical decisions in breast augmentation using five measurements in 5 minutes: the high five decision process. Plast Reconstr Surg 118(7S):35S-45S
    • (2006) Plast Reconstr Surg , vol.118 , Issue.7 S
    • Tebbetts, J.1    Adams, W.2
  • 8
    • 0017128326 scopus 로고
    • Breast sensation before and after plastic surgery
    • Courtiss EH, Goldwyn RM (1976) Breast sensation before and after plastic surgery. Plast Reconstr Surg 58(1):1-13
    • (1976) Plast Reconstr Surg , vol.58 , Issue.1 , pp. 1-13
    • Courtiss, E.H.1    Goldwyn, R.M.2
  • 9
    • 33646846075 scopus 로고    scopus 로고
    • Nipple-areola complex sensitivity after primary breast augmentation: A comparison of periareolar and inframammary incision approaches
    • Mofid MM, Klatsky SA, Singh NK et al (2006) Nipple-areola complex sensitivity after primary breast augmentation: a comparison of periareolar and inframammary incision approaches. Plast Reconstr Surg 117(6):1694-1698
    • (2006) Plast Reconstr Surg , vol.117 , Issue.6 , pp. 1694-1698
    • Mofid, M.M.1    Klatsky, S.A.2    Singh, N.K.3
  • 10
    • 33644859354 scopus 로고    scopus 로고
    • Effect of augmentation mammaplasty on breast sensation
    • Okwueze MI, Spear ME, Zwyghuizen AM et al (2006) Effect of augmentation mammaplasty on breast sensation. Plast Reconstr Surg 117(1):73-83
    • (2006) Plast Reconstr Surg , vol.117 , Issue.1 , pp. 73-83
    • Okwueze, M.I.1    Spear, M.E.2    Zwyghuizen, A.M.3
  • 11
    • 41849114567 scopus 로고    scopus 로고
    • MOC-PSSM CME Article: Breast augmentation
    • Alpert BS, Lalonde DH (2008) MOC-PSSM CME Article: breast augmentation. Plast Reconstr Surg 121(4):1-7
    • (2008) Plast Reconstr Surg , vol.121 , Issue.4 , pp. 1-7
    • Alpert, B.S.1    Lalonde, D.H.2
  • 12
    • 0034099049 scopus 로고    scopus 로고
    • Breast augmentation: Choosing the optimal incision, implant, and pocket plane
    • Hildago DA (2000) Breast augmentation: choosing the optimal incision, implant, and pocket plane. Plast Reconstr Surg 105(6):2202-2216
    • (2000) Plast Reconstr Surg , vol.105 , Issue.6 , pp. 2202-2216
    • Hildago, D.A.1
  • 13
    • 58149397417 scopus 로고    scopus 로고
    • The process of breast augmentation: Four sequential steps for optimizing outcomes for patients
    • Adams WP (2008) The process of breast augmentation: four sequential steps for optimizing outcomes for patients. Plast Reconstr Surg 122(6):1892-1900
    • (2008) Plast Reconstr Surg , vol.122 , Issue.6 , pp. 1892-1900
    • Adams, W.P.1
  • 14
    • 40149084373 scopus 로고    scopus 로고
    • Relationship of incision choice to capsular contracture
    • Wiener TC (2008) Relationship of incision choice to capsular contracture. Aesthet Plast Surg 32(2):303-306
    • (2008) Aesthet Plast Surg , vol.32 , Issue.2 , pp. 303-306
    • Wiener, T.C.1
  • 15
    • 37349065517 scopus 로고    scopus 로고
    • Style 410 highly cohesive silicone breast implant core study results at 3 years
    • Bengston BP, Van Natta BW, Murphy DK et al (2007) Style 410 highly cohesive silicone breast implant core study results at 3 years. Plast Reconstr Surg 120(Suppl 1):40S
    • (2007) Plast Reconstr Surg , vol.120 , Issue.SUPPL. 1
    • Bengston, B.P.1    Van Natta, B.W.2    Murphy, D.K.3
  • 16
    • 37349085816 scopus 로고    scopus 로고
    • Inamed silicone breast implant core study results at 6 years
    • Inamed Silicone Breast Implant U.S. Study Group, discussion 17S-18S
    • Spear SL, Murphy DK, Slicton A, Walker PS; Inamed Silicone Breast Implant U.S. Study Group (2007) Inamed silicone breast implant core study results at 6 years. Plast Reconstr Surg 120(Suppl 1):8S-16S; discussion 17S-18S
    • (2007) Plast Reconstr Surg , vol.120 , Issue.SUPPL. 1
    • Spear, S.L.1    Murphy, D.K.2    Slicton, A.3    Walker, P.S.4
  • 17
    • 37349001692 scopus 로고    scopus 로고
    • The Mentor core study on silicone MemoryGel breast implants
    • Cunningham BL (2007) The Mentor core study on silicone MemoryGel breast implants. Plast Reconstr Surg 120(Suppl 1): 19S-29S
    • (2007) Plast Reconstr Surg , vol.120 , Issue.SUPPL. 1
    • Cunningham, B.L.1
  • 18
    • 67349285721 scopus 로고    scopus 로고
    • Safety and effectiveness of Mentor's MemoryGel implants at 6 years
    • Cunningham B, McCue J (2009) Safety and effectiveness of Mentor's MemoryGel implants at 6 years. Aesthet Plast Surg 33(3):439-444
    • (2009) Aesthet Plast Surg , vol.33 , Issue.3 , pp. 439-444
    • Cunningham, B.1    McCue, J.2
  • 19
    • 33645742303 scopus 로고    scopus 로고
    • A long-term study of outcomes, complications, and patient satisfaction with breast implants
    • Handel N, Cordray T, Gutierrez J et al (2006) A long-term study of outcomes, complications, and patient satisfaction with breast implants. Plast Reconstr Surg 117(3):757-767
    • (2006) Plast Reconstr Surg , vol.117 , Issue.3 , pp. 757-767
    • Handel, N.1    Cordray, T.2    Gutierrez, J.3
  • 20
    • 0018138661 scopus 로고
    • Influence of some operative and postoperative factors on capsular contracture around breast prostheses
    • Hipps CJ, Raju DR, Straith RE (1978) Influence of some operative and postoperative factors on capsular contracture around breast prostheses. Plast Reconstr Surg 61(3):384-389
    • (1978) Plast Reconstr Surg , vol.61 , Issue.3 , pp. 384-389
    • Hipps, C.J.1    Raju, D.R.2    Straith, R.E.3
  • 21
    • 64049086126 scopus 로고    scopus 로고
    • Primary breast augmentation today: A survey of current breast augmentation practice patterns
    • Reece EM, Ghavami A, Hoxworth RE et al (2009) Primary breast augmentation today: a survey of current breast augmentation practice patterns. Aesthet Surg J 29(2):116-121
    • (2009) Aesthet Surg J , vol.29 , Issue.2 , pp. 116-121
    • Reece, E.M.1    Ghavami, A.2    Hoxworth, R.E.3
  • 22
    • 67650802752 scopus 로고    scopus 로고
    • Minimal inframammary incision for breast augmentation
    • Fanous N, Tawilé C, Brousseau VJ (2008) Minimal inframammary incision for breast augmentation. Can J Plast Surg 16(1):14-17
    • (2008) Can J Plast Surg , vol.16 , Issue.1 , pp. 14-17
    • Fanous, N.1    Tawilé, C.2    Brousseau, V.J.3
  • 24
    • 37349042263 scopus 로고    scopus 로고
    • Transcript of the FDAPanel, (April ) 2 Nov 2011
    • Transcript of the FDAPanel,Mentor hearings (April 2005). http:// www.fda.gov/ohrms/dockets/ac/05/transcripts/2005-4101t3.doc. Accessed 2 Nov 2011
    • (2005) Mentor Hearings
  • 25
    • 67349238626 scopus 로고    scopus 로고
    • 2 Nov 2011
    • FDA Summary Panel Memorandum: Mentor P030053. http:// www.fda.gov/ohrms/dockets/ac/05/briefing/2005-4101b1-Tab-1-fda- Mentor%20Panel%20Memo.pdf. Accessed 2 Nov 2011
    • FDA Summary Panel Memorandum: Mentor P030053.
  • 26
    • 0023091664 scopus 로고
    • A critical look at capsular contracture in subglandular versus subpectoral mammary augmentation
    • Puckett CL, Croll GH, Reichel CA, Concannon MJ (1987) A critical look at capsular contracture in subglandular versus subpectoral mammary augmentation. Aesthet Plast Surg 11(1):23-28
    • (1987) Aesthet Plast Surg , vol.11 , Issue.1 , pp. 23-28
    • Puckett, C.L.1    Croll, G.H.2    Reichel, C.A.3    Concannon, M.J.4
  • 27
    • 0025266869 scopus 로고
    • Augmentation mammaplasty: A comparative analysis
    • Biggs TM, Yarish RS (1990) Augmentation mammaplasty: a comparative analysis. Plast Reconstr Surg 85(3):368-372
    • (1990) Plast Reconstr Surg , vol.85 , Issue.3 , pp. 368-372
    • Biggs, T.M.1    Yarish, R.S.2
  • 28
    • 33745343564 scopus 로고    scopus 로고
    • Textured-surface breast implants in the prevention of capsular contracture among breast augmentation patients: A meta-analysis of randomized controlled trials
    • Barnsley PG, Sigurdson LJ, Barnsley SE (2006) Textured-surface breast implants in the prevention of capsular contracture among breast augmentation patients: a meta-analysis of randomized controlled trials. Plast Reconstr Surg 117(7):2182-2190
    • (2006) Plast Reconstr Surg , vol.117 , Issue.7 , pp. 2182-2190
    • Barnsley, P.G.1    Sigurdson, L.J.2    Barnsley, S.E.3
  • 29
    • 84868156795 scopus 로고    scopus 로고
    • Capsular contracture following augmentation mammaplasty: Etiology and pathogenesis
    • Shiffman MA (ed) , 1st edn. Springer, Berlin
    • McCurdy JA Jr (2009) Capsular contracture following augmentation mammaplasty: etiology and pathogenesis. In: Shiffman MA (ed) Breast augmentation principles and practice, 1st edn. Springer, Berlin, pp 525-540
    • (2009) Breast Augmentation Principles and Practice , pp. 525-540
    • McCurdy Jr., J.A.1
  • 30
    • 84868104486 scopus 로고    scopus 로고
    • Breast implant capsules and subclinical infection
    • Snell L, Brown M (2009) Breast implant capsules and subclinical infection. Plast Reconstr Surg 124(4S):38
    • (2009) Plast Reconstr Surg , vol.124 , Issue.4 S , pp. 38
    • Snell, L.1    Brown, M.2
  • 31
    • 79959734225 scopus 로고    scopus 로고
    • Bacteria on breast implants are associated with capsular contracture
    • Tran VT, Del Pozo JL, Petty PM et al (2009) Bacteria on breast implants are associated with capsular contracture. Plast Reconstr Surg 124(4S):38-39
    • (2009) Plast Reconstr Surg , vol.124 , Issue.4 S , pp. 38-39
    • Tran, V.T.1    Del Pozo, J.L.2    Petty, P.M.3
  • 32
    • 56849107851 scopus 로고    scopus 로고
    • Capsular contracture: What is it? What causes it? How can it be prevented and managed?
    • Adams WP Jr (2009) Capsular contracture: What is it? What causes it? How can it be prevented and managed? Clin Plast Surg 36:119-126
    • (2009) Clin Plast Surg , vol.36 , pp. 119-126
    • Adams Jr., W.P.1
  • 33
    • 77956483284 scopus 로고    scopus 로고
    • Subclinical (biofilm) infection causes capsular contracture in a porcine model following augmentation mammaplasty
    • Tamboto H, Vickery K, Deva AK (2010) Subclinical (biofilm) infection causes capsular contracture in a porcine model following augmentation mammaplasty. Plast Reconstr Surg 126(3):835-842
    • (2010) Plast Reconstr Surg , vol.126 , Issue.3 , pp. 835-842
    • Tamboto, H.1    Vickery, K.2    Deva, A.K.3
  • 34
    • 0345270043 scopus 로고    scopus 로고
    • Detection of subclinical infection in significant breast implant capsules
    • Pajkos A, Deva AK, Vickery K et al (2003) Detection of subclinical infection in significant breast implant capsules. Plast Reconstr Surg 111(5):1605-1611
    • (2003) Plast Reconstr Surg , vol.111 , Issue.5 , pp. 1605-1611
    • Pajkos, A.1    Deva, A.K.2    Vickery, K.3
  • 35
    • 33749428731 scopus 로고    scopus 로고
    • Capsular contracture in subglandular breast augmentation with textured versus smooth breast implants: A systematic review
    • Wong C, Samuel M, Tan B et al (2006) Capsular contracture in subglandular breast augmentation with textured versus smooth breast implants: a systematic review. Plast Reconstr Surg 118(5):1224-1236
    • (2006) Plast Reconstr Surg , vol.118 , Issue.5 , pp. 1224-1236
    • Wong, C.1    Samuel, M.2    Tan, B.3
  • 36
    • 78650049686 scopus 로고    scopus 로고
    • Capsular contracture with breast implants in the cosmetic patient: Saline versus silicone-A systematic review of the literature
    • Schaub T, Ahmad J, Rohrich RJ (2010) Capsular contracture with breast implants in the cosmetic patient: saline versus silicone-a systematic review of the literature. Plast Reconstr Surg 126(6):2140-2149
    • (2010) Plast Reconstr Surg , vol.126 , Issue.6 , pp. 2140-2149
    • Schaub, T.1    Ahmad, J.2    Rohrich, R.J.3
  • 37
    • 74049107782 scopus 로고    scopus 로고
    • Capsular contracture: A systematic review
    • Araco A, Caruso R, Araco F et al (2009) Capsular contracture: a systematic review. Plast Reconstr Surg 124(6):1808-1819
    • (2009) Plast Reconstr Surg , vol.124 , Issue.6 , pp. 1808-1819
    • Araco, A.1    Caruso, R.2    Araco, F.3
  • 38
    • 0028850615 scopus 로고
    • The effect of Biocell texturing and povidone-iodine irrigation on capsular contracture around salineinflatable breast implants
    • Burkhardt BR, Eades E (1995) The effect of Biocell texturing and povidone-iodine irrigation on capsular contracture around salineinflatable breast implants. Plast Reconstr Surg 96(6):1317-1325
    • (1995) Plast Reconstr Surg , vol.96 , Issue.6 , pp. 1317-1325
    • Burkhardt, B.R.1    Eades, E.2
  • 39
    • 33746812723 scopus 로고    scopus 로고
    • Textured salinefilled breast implants for augmentation mammoplasty: Does overfilling prevent deflation?
    • A Long-term Follow-up
    • Al-Sabounchi S, De Mey AM, Eder H (2006) Textured salinefilled breast implants for augmentation mammoplasty: Does overfilling prevent deflation? A long-term follow-up. Plast Reconstr Surg 118(1):215-222
    • (2006) Plast Reconstr Surg , vol.118 , Issue.1 , pp. 215-222
    • Al-Sabounchi, S.1    De Mey, A.M.2    Eder, H.3
  • 40
    • 0028793373 scopus 로고
    • The fate of breast implants: A critical analysis of complications and outcomes
    • Handel N, Jensen JA, Black Q et al (1995) The fate of breast implants: a critical analysis of complications and outcomes. Plast Reconstr Surg 96(7):1521-1533
    • (1995) Plast Reconstr Surg , vol.96 , Issue.7 , pp. 1521-1533
    • Handel, N.1    Jensen, J.A.2    Black, Q.3
  • 41
    • 79952740418 scopus 로고    scopus 로고
    • A 15-year experience with primary breast augmentation
    • Codner MA, Mejia JD, Locke MB et al (2011) A 15-year experience with primary breast augmentation. Plast Reconstr Surg 127(3):1300-1310
    • (2011) Plast Reconstr Surg , vol.127 , Issue.3 , pp. 1300-1310
    • Codner, M.A.1    Mejia, J.D.2    Locke, M.B.3
  • 42
    • 56849118261 scopus 로고    scopus 로고
    • Management of common and uncommon problems after primary breast augmentation
    • Nahabedian M, Patel K (2008) Management of common and uncommon problems after primary breast augmentation. Clin Plast Surg 36:127-138
    • (2008) Clin Plast Surg , vol.36 , pp. 127-138
    • Nahabedian, M.1    Patel, K.2
  • 43
    • 37349107170 scopus 로고    scopus 로고
    • The Mentor study on contour profile gel silicone MemoryGel breast implants
    • Cunningham B (2007) The Mentor study on contour profile gel silicone MemoryGel breast implants. Plast Reconstr Surg 120(7):33S-39S
    • (2007) Plast Reconstr Surg , vol.120 , Issue.7
    • Cunningham, B.1
  • 44
    • 0034109878 scopus 로고    scopus 로고
    • Saline-filled breast implant safety and efficacy: A multicenter retrospective review
    • Cunningham BL, Lokeh A, Gutowski KA (2000) Saline-filled breast implant safety and efficacy: a multicenter retrospective review. Plast Reconstr Surg 105(6):2143-2149
    • (2000) Plast Reconstr Surg , vol.105 , Issue.6 , pp. 2143-2149
    • Cunningham, B.L.1    Lokeh, A.2    Gutowski, K.A.3
  • 45
    • 60149084837 scopus 로고    scopus 로고
    • Natrelle saline-filled breast implants: A prospective 10-year study
    • Walker PS, Walls B, Murphy DK (2009) Natrelle saline-filled breast implants: a prospective 10-year study. Aesthet Surg J 29:19-25
    • (2009) Aesthet Surg J , vol.29 , pp. 19-25
    • Walker, P.S.1    Walls, B.2    Murphy, D.K.3
  • 46
    • 34447312231 scopus 로고    scopus 로고
    • Infections of breast implants in aesthetic breast augmentations: A single-center review of 3,002 patients
    • Araco A, Gravante G, Araco F et al (2007) Infections of breast implants in aesthetic breast augmentations: a single-center review of 3,002 patients. Aesthet Plast Surg 31(4):325-329
    • (2007) Aesthet Plast Surg , vol.31 , Issue.4 , pp. 325-329
    • Araco, A.1    Gravante, G.2    Araco, F.3
  • 47
    • 0034055365 scopus 로고    scopus 로고
    • Silicone gel-filled breast implant integrity: A retrospective review of 478 consecutively explanted implants
    • Collis N, Sharpe DT (2000) Silicone gel-filled breast implant integrity: a retrospective review of 478 consecutively explanted implants. Plast Reconstr Surg 105:1979
    • (2000) Plast Reconstr Surg , vol.105 , pp. 1979
    • Collis, N.1    Sharpe, D.T.2
  • 48
    • 0033857859 scopus 로고    scopus 로고
    • Recurrence of subglandular breast implant capsular contracture: Anterior versus total capsulectomy
    • Collis N, Sharpe DT (2000) Recurrence of subglandular breast implant capsular contracture: anterior versus total capsulectomy. Plast Reconstr Surg 106:792
    • (2000) Plast Reconstr Surg , vol.106 , pp. 792
    • Collis, N.1    Sharpe, D.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.