-
1
-
-
0014406108
-
Initial clinical experience with intraaortic balloon pumping in cardiogenic shock
-
Kantrowitz A, Tjonneland S, Freed PS, Phillips SJ, Butner AN, Sherman JL Jr: Initial clinical experience with intraaortic balloon pumping in cardiogenic shock. JAMA 203: 113-118, 1968.
-
(1968)
JAMA
, vol.203
, pp. 113-118
-
-
Kantrowitz, A.1
Tjonneland, S.2
Freed, P.S.3
Phillips, S.J.4
Butner, A.N.5
Sherman Jr., J.L.6
-
2
-
-
0026128995
-
Optimal control system for the intra-aortic balloon pump
-
Smith B, Barnea O, Moore TW, Jaron D: Optimal control system for the intra-aortic balloon pump. Med Biol Eng Comput 29: 180-184, 1991.
-
(1991)
Med Biol Eng Comput
, vol.29
, pp. 180-184
-
-
Smith, B.1
Barnea, O.2
Moore, T.W.3
Jaron, D.4
-
4
-
-
17344380708
-
Hemodynamic effects of new intra-aortic balloon counterpulsation timing methods in patients: A multicenter evaluation
-
Kern MJ, Aguirre FV, Caracciolo EA, et al: Hemodynamic effects of new intra-aortic balloon counterpulsation timing methods in patients: A multicenter evaluation. Am Heart J 137: 1129-1136, 1999. (Pubitemid 30040739)
-
(1999)
American Heart Journal
, vol.137
, Issue.6
, pp. 1129-1136
-
-
Kern, M.J.1
Aguirre, F.V.2
Caracciolo, E.A.3
Bach, R.G.4
Donohue, T.J.5
Lasorda, D.6
Ohman, E.M.7
Schnitzler, R.N.8
King, D.L.9
Ohley, W.J.10
Grayzel, J.11
-
5
-
-
0026074921
-
Modeling the dynamic interaction between left ventri¬cle and intra-aortic balloon pump
-
4 Pt 2
-
Sun Y: Modeling the dynamic interaction between left ventri¬cle and intra-aortic balloon pump. Am J Physiol 261(4 Pt 2): H1300YH1311, 1991.
-
(1991)
Am J Physiol
, vol.261
-
-
Sun, Y.1
-
7
-
-
0021471767
-
The intraaortic balloon pump: A nonlinear digital computer model
-
Kuklinski WS, Jaron D, Ohley WJ, Greenall RK Jr: The intraaortic balloon pump: A nonlinear digital computer model. J Biomech Eng 106: 220-228, 1984. (Pubitemid 14022373)
-
(1984)
Journal of Biomechanical Engineering
, vol.106
, Issue.3
, pp. 220-228
-
-
Kuklinski, W.S.1
Jaron, D.2
Ohley, W.J.3
Greenall Jr., R.K.4
-
8
-
-
0015594766
-
Load independence of the instan¬taneous pressure-volume ratio of the canine left ventricle and effects of epinephrine and heart rate on the ratio
-
Suga H, Sagawa K, Shoukas AA: Load independence of the instan¬taneous pressure-volume ratio of the canine left ventricle and effects of epinephrine and heart rate on the ratio. Circ Res 32: 314-322, 1973.
-
(1973)
Circ Res
, vol.32
, pp. 314-322
-
-
Suga, H.1
Sagawa, K.2
Shoukas, A.A.3
-
9
-
-
33645743807
-
Modeling ventricular function during cardiac assist: Does time-varying elastance work?
-
DOI 10.1097/01.mat.0000196525.56523.b8, PII 0000248020060100000002
-
Vandenberghe S, Segers P, Steendijk P, et al: Modeling ventricu¬lar function during cardiac assist: Does time-varying elastance work? ASAIO J 52: 4-8, 2006. (Pubitemid 44314890)
-
(2006)
ASAIO Journal
, vol.52
, Issue.1
, pp. 4-8
-
-
Vandenberghe, S.1
Segers, P.2
Steendijk, P.3
Meyns, B.4
Dion, R.A.E.5
Antaki, J.F.6
Verdonck, P.7
-
10
-
-
0026012982
-
Relation between left ventricular cavity pressure and volume and systolic fiber stress and strain in the wall
-
Arts T, Bovendeerd PH, Prinzen FW, Reneman RS: Relation between left ventricular cavity pressure and volume and systolic fiber stress and strain in the wall. Biophys J 59: 93-102, 1991.
-
(1991)
Biophys J
, vol.59
, pp. 93-102
-
-
Arts, T.1
Bovendeerd, P.H.2
Prinzen, F.W.3
Reneman, R.S.4
-
11
-
-
33751071324
-
Dependence of intramyocardial pressure and coronary flow on ventricular loading and contractility: A model study
-
DOI 10.1007/s10439-006-9189-2
-
Bovendeerd PH, Borsje P, Arts T, van De Vosse FN: Dependence of intramyocardial pressure and coronary flow on ventricular loading and contractility: A model study. Ann Biomed Eng 34: 1833-1845, 2006. (Pubitemid 44770837)
-
(2006)
Annals of Biomedical Engineering
, vol.34
, Issue.12
, pp. 1833-1845
-
-
Bovendeerd, P.H.M.1
Borsje, P.2
Arts, T.3
Van De Vosse, F.N.4
-
12
-
-
0000682154
-
The heat of shortening and the dynamic constants in muscle
-
Hill A: The heat of shortening and the dynamic constants in muscle. Proceedings of the Royal Society London. 126: 136-165, 1938.
-
(1938)
Proceedings of the Royal Society London
, vol.126
, pp. 136-165
-
-
Hill, A.1
-
13
-
-
4344593862
-
A physiologically representative in vitro model of the coronary circulation
-
DOI 10.1088/0967-3334/25/4/009, PII S0967333404738423
-
Geven MC, Bohté VN, Aarnoudse WH, et al: A physiologically representative in vitro model of the coronary circulation. Physiol Meas 25: 891-904, 2004. (Pubitemid 39121172)
-
(2004)
Physiological Measurement
, vol.25
, Issue.4
, pp. 891-904
-
-
Geven, M.C.F.1
Bohte, V.N.2
Aarnoudse, W.H.3
Van Den Berg, P.M.J.4
Rutten, M.C.M.5
Pijls, N.H.J.6
Van De Vosse, F.N.7
-
14
-
-
68549090655
-
A mathematical model to evaluate control strategies for mechanical circulatory support
-
Cox LG, Loerakker S, Rutten MC, de Mol BA, van de Vosse FN: A mathematical model to evaluate control strategies for mechanical circulatory support. Artif Organs 33: 593-603, 2009.
-
(2009)
Artif Organs
, vol.33
, pp. 593-603
-
-
Cox, L.G.1
Loerakker, S.2
Rutten, M.C.3
De Mol, B.A.4
Van De Vosse, F.N.5
|