메뉴 건너뛰기




Volumn 13, Issue 5, 2010, Pages 567-576

Mathematical modelling of intra-aortic balloon pump

Author keywords

Cardiovascular system; Intra aortic balloon pump; Mathematical modelling

Indexed keywords

BEFORE AND AFTER; BLOCK DIAGRAMS; BLOOD FLOW; CLINICAL OBSERVATION; INTRA-AORTIC BALLOON PUMP; ISCHEMIC HEART DISEASE; LEFT VENTRICLES; MATHEMATICAL MODELLING; MATLAB- SOFTWARE; MODEL VERIFICATION; MYOCARDIAL INFARCTION; NORMAL OPERATIONS; PATHOLOGICAL CONDITIONS; PRESSURE-TIME CURVES; SIMULATION RESULT; THEORETICAL MODELS; THORACIC AORTA; TIME CURVES;

EID: 77958095634     PISSN: 10255842     EISSN: 14768259     Source Type: Journal    
DOI: 10.1080/10255840903352532     Document Type: Article
Times cited : (8)

References (20)
  • 1
    • 0017370379 scopus 로고
    • Reconstruction of the action potential of the ventricular myocardial fibers
    • Beeler GW, Reuter H. 1977. Reconstruction of the action potential of the ventricular myocardial fibers. J Physiol. 268:177-210.
    • (1977) J Physiol , vol.268 , pp. 177-210
    • Beeler, G.W.1    Reuter, H.2
  • 4
    • 0038385834 scopus 로고    scopus 로고
    • Efficiency of a new intra aortic propeller pump vs the intra aortic balloon pump (an animal study)
    • Dekker A, Reesink K, van der Veen E, Van Ommen V, Geskes G, Soemers C, Maessen J. 2003. Efficiency of a new intra aortic propeller pump vs the intra aortic balloon pump (an animal study). Chest J. 123:2089-2095.
    • (2003) Chest J , vol.123 , pp. 2089-2095
    • Dekker, A.1    Reesink, K.2    van der Veen, E.3    Van Ommen, V.4    Geskes, G.5    Soemers, C.6    Maessen, J.7
  • 6
    • 0002315488 scopus 로고    scopus 로고
    • Overview of circulation; medical physics of pressure, flow, and resistance
    • Hall JE, editor. 9th ed. Philadelphia (PA): Saunders
    • Guyton AC, Hall JE. 1996. Overview of circulation; medical physics of pressure, flow, and resistance. In: Hall JE, editor. Textbook of medical physiology. 9th ed. Philadelphia (PA): Saunders. p. 107-119.
    • (1996) Textbook of medical physiology , pp. 107-119
    • Guyton, A.C.1    Hall, J.E.2
  • 7
    • 34447116752 scopus 로고    scopus 로고
    • Simulation of the cardiovascular system using equivalent electronic system
    • Hassani K, Navidbakhsh M, Rostami M. 2006. Simulation of the cardiovascular system using equivalent electronic system. J Biomed Paper. 150(1):105-112.
    • (2006) J Biomed Paper , vol.150 , Issue.1 , pp. 105-112
    • Hassani, K.1    Navidbakhsh, M.2    Rostami, M.3
  • 8
    • 0036095682 scopus 로고    scopus 로고
    • Modelling of cardiovascular response to orthostatic stress
    • Heldet T, Shim E. 2002. Modelling of cardiovascular response to orthostatic stress. J Appl Physiol. 92:1239-1254.
    • (2002) J Appl Physiol , vol.92 , pp. 1239-1254
    • Heldet, T.1    Shim, E.2
  • 9
    • 33745193927 scopus 로고    scopus 로고
    • A closed-loop lumped parameter computational model for human cardiovascular system
    • Liang F, Liu H. 2005. A closed-loop lumped parameter computational model for human cardiovascular system. JSME Int J Ser C. 48(4):484-493.
    • (2005) JSME Int J Ser C , vol.48 , Issue.4 , pp. 484-493
    • Liang, F.1    Liu, H.2
  • 12
    • 29544441616 scopus 로고    scopus 로고
    • On deriving lumped models for blood flow and pressure in the systemic arteries
    • Olufsen MS, Nadim A. 2004. On deriving lumped models for blood flow and pressure in the systemic arteries. J Math Biosci Eng. 1(1):61-80.
    • (2004) J Math Biosci Eng , vol.1 , Issue.1 , pp. 61-80
    • Olufsen, M.S.1    Nadim, A.2
  • 13
    • 0034098790 scopus 로고    scopus 로고
    • Hymodynamic properties of a new percutaneous intra aortic axial flow pump
    • Reitan O, Sternby J, Ohlin H. 2000. Hymodynamic properties of a new percutaneous intra aortic axial flow pump. ASAIO J. 46:323-329.
    • (2000) ASAIO J , vol.46 , pp. 323-329
    • Reitan, O.1    Sternby, J.2    Ohlin, H.3
  • 15
    • 0036137031 scopus 로고    scopus 로고
    • Simulation of steady state and transient phenomena by using the equivalent electronic circuit
    • Rupnic M, Runvovc F. 2002. Simulation of steady state and transient phenomena by using the equivalent electronic circuit. J Comput Methods Prog Biomed. 67:1-12.
    • (2002) J Comput Methods Prog Biomed , vol.67 , pp. 1-12
    • Rupnic, M.1    Runvovc, F.2
  • 16
    • 0842265890 scopus 로고    scopus 로고
    • Enhanced coronary flow velocity during intra-aortic balloon pumping assessed by transthoracic Doppler echocardiography
    • Takeuchi M, Nohtomi Y, Yoshitani H, Miyazaki C, Sakamoto K, Yoshikawa J. 2004. Enhanced coronary flow velocity during intra-aortic balloon pumping assessed by transthoracic Doppler echocardiography. J Am Coll Cardiol. 43:368-376.
    • (2004) J Am Coll Cardiol , vol.43 , pp. 368-376
    • Takeuchi, M.1    Nohtomi, Y.2    Yoshitani, H.3    Miyazaki, C.4    Sakamoto, K.5    Yoshikawa, J.6
  • 18
    • 56149091752 scopus 로고    scopus 로고
    • Biofluid mechanics in cardiovascular system
    • New York: McGraw-Hill
    • Waite L. 2006. Biofluid mechanics in cardiovascular system. Biomedical engineering series. New York: McGraw-Hill.
    • (2006) Biomedical engineering series
    • Waite, L.1
  • 19
    • 0942305100 scopus 로고    scopus 로고
    • Wave propagation in a model of arterial circulation
    • Wang JJ, Parker KH. 2004. Wave propagation in a model of arterial circulation. J Biomech. 37:457-470.
    • (2004) J Biomech , vol.37 , pp. 457-470
    • Wang, J.J.1    Parker, K.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.