Performance of sintered, porous-surfaced, press-fit implants after 10 years of function in the partially edentulous posterior mandible

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ALVEOLAR BONE LOSS; ARTICLE; CLINICAL TRIAL; COMPARATIVE STUDY; DENTAL ABUTMENT; DENTAL SURGERY; DEVICE REMOVAL; EDENTULOUSNESS; FEMALE; FOLLOW UP; HUMAN; MALE; MANDIBLE; MIDDLE AGED; POROSITY; PROSPECTIVE STUDY; SURFACE PROPERTY; SURVIVAL; TOOTH CROWN; TOOTH IMPLANT; TOOTH PROSTHESIS; TOOTH RADIOGRAPHY; TREATMENT OUTCOME;

EID: 84872041738     PISSN: 01987569     EISSN: 19453388     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (16)

References (34)
  • 1
    • 0031152016 scopus 로고    scopus 로고
    • Long-term evaluation of non-submerged ITI implant Part I: 8-year life table analysis of a prospective multi-center study with 2359 implants
    • Buser D, Mericske-Stern R, Bernard JP, et al. Long-term evaluation of non-submerged ITI implant. Part I: 8-year life table analysis of a prospective multi-center study with 2359 implants. Clin Oral Implants Res 1997; 8: 161-172.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 161-172
    • Buser, D.1    Mericske-Stern, R.2    Bernard, J.P.3
  • 2
    • 0032016827 scopus 로고    scopus 로고
    • Treatment outcomes of patients with implant-supported fixed partial prostheses
    • Wyatt CC, Zarb G. Treatment outcomes of patients with implant-supported fixed partial prostheses. Int J Oral Maxillofac Implants 1998; 13: 204-211.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 204-211
    • Wyatt, C.C.1    Zarb, G.2
  • 3
    • 0036688398 scopus 로고    scopus 로고
    • Biologic outcome of implant-supported restorations in the treatment of partial edentulism Part I: A longitudinal clinical evaluation
    • Naert I, Koutsikakis G, Duyck J, Quirynen M, Jacobs R, van Steenberghe D. Biologic outcome of implant-supported restorations in the treatment of partial edentulism. Part I: A longitudinal clinical evaluation. Clin Oral Implants Res 2002; 13: 381-389.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 381-389
    • Naert, I.1    Koutsikakis, G.2    Duyck, J.3    Quirynen, M.4    Jacobs, R.5    van Steenberghe, D.6
  • 5
    • 17844385046 scopus 로고    scopus 로고
    • Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures
    • Hermann I, Lekholm U, Holm S, Kultje C. Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures. Int J Oral Maxillofac Implants 2005; 20: 220-230.
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 220-230
    • Hermann, I.1    Lekholm, U.2    Holm, S.3    Kultje, C.4
  • 7
    • 33748323290 scopus 로고    scopus 로고
    • Impact of implant length and diameter on survival rates
    • Renouard F, Nisand D. Impact of implant length and diameter on survival rates. Clin Oral Implants Res 2006; 17(suppl 2): 35-51.
    • (2006) Clin Oral Implants Res , vol.17 , pp. 35-51
    • Renouard, F.1    Nisand, D.2
  • 8
    • 38549148514 scopus 로고    scopus 로고
    • Five-year clinical evaluation of short dental implants placed in posterior areas: A retrospective study
    • Anitua E, Orive G, Aguirre JJ, Andia I. Five-year clinical evaluation of short dental implants placed in posterior areas: A retrospective study. J Periodontol 2008; 79: 42-48.
    • (2008) J Periodontol , vol.79 , pp. 42-48
    • Anitua, E.1    Orive, G.2    Aguirre, J.J.3    Andia, I.4
  • 9
    • 0035461999 scopus 로고    scopus 로고
    • Managing the posterior mandible of partially edentulous patients with short, porous-surfaced dental implants: Early data from a clinical trial
    • Deporter DA, Pilliar RM, Todescan R, Watson PA, Pharoah M. Managing the posterior mandible of partially edentulous patients with short, porous-surfaced dental implants: Early data from a clinical trial. Int J Oral Maxillofac Implants 2001; 16: 653-658.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 653-658
    • Deporter, D.A.1    Pilliar, R.M.2    Todescan, R.3    Watson, P.A.4    Pharoah, M.5
  • 10
    • 0025493944 scopus 로고
    • The applicability of osseointegrated oral implants in the rehabilitation of partial edentulism: A prospective multicenter study on 558 fixtures
    • Van Steenberghe D, Lekholm U, Bolender C, et al. The applicability of osseointegrated oral implants in the rehabilitation of partial edentulism: A prospective multicenter study on 558 fixtures. Int J Oral Maxillofac Implants 1990; 5: 272-281.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 272-281
    • Van Steenberghe, D.1    Lekholm, U.2    Bolender, C.3
  • 11
    • 5444236172 scopus 로고    scopus 로고
    • Oral implant surfaces: Part I-Review focusing on topographic and chemical properties of different surfaces and in vivo responses to them
    • Albrektsson T, Wennerberg A. Oral implant surfaces: Part I-Review focusing on topographic and chemical properties of different surfaces and in vivo responses to them. Int J Prosthodont 2004; 17: 536-543.
    • (2004) Int J Prosthodont , vol.17 , pp. 536-543
    • Albrektsson, T.1    Wennerberg, A.2
  • 12
    • 0032617146 scopus 로고    scopus 로고
    • Fivemm-diameter implants without a smooth surface collar: Report on 98 consecutive placements
    • Renouard F, Arnoux JP, Sarment D. Fivemm-diameter implants without a smooth surface collar: Report on 98 consecutive placements. Int J Oral Maxillofac Implants 1999; 14: 101-107.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 101-107
    • Renouard, F.1    Arnoux, J.P.2    Sarment, D.3
  • 13
    • 0036134211 scopus 로고    scopus 로고
    • Comparative evaluation of the effect of diameter, length and number of implants supporting threeunit fixed partial prostheses on stress distribution in the bone
    • Iplikçioğlu H, Akça K. Comparative evaluation of the effect of diameter, length and number of implants supporting threeunit fixed partial prostheses on stress distribution in the bone. J Dent 2002; 30: 41-46.
    • (2002) J Dent , vol.30 , pp. 41-46
    • Iplikçioğlu, H.1    Akça, K.2
  • 14
    • 38549130914 scopus 로고    scopus 로고
    • Clinical outcome of narrow diameter implants:A retrospective study of 510 implants
    • Degidi M, Piattelli A, Carinci F. Clinical outcome of narrow diameter implants:A retrospective study of 510 implants. J Periodontol 2008; 79: 49-54.
    • (2008) J Periodontol , vol.79 , pp. 49-54
    • Degidi, M.1    Piattelli, A.2    Carinci, F.3
  • 15
    • 34548672563 scopus 로고    scopus 로고
    • Influence of implant diameter on surrounding bone
    • Brink J, Meraw S, Sarment DP. Influence of implant diameter on surrounding bone. Clin Oral Implants Res 2007; 18: 563-568.
    • (2007) Clin Oral Implants Res , vol.18 , pp. 563-568
    • Brink, J.1    Meraw, S.2    Sarment, D.P.3
  • 16
    • 5444226736 scopus 로고    scopus 로고
    • Five-year survival distributions of short-length (10 mm or less) machinesurfaced and Osseotite implants
    • Feldman S, Boitel N, Weng D, Kohles SS, Stach RM. Five-year survival distributions of short-length (10 mm or less) machinesurfaced and Osseotite implants. Clin Implant Dent Relat Res 2004; 6: 16-23.
    • (2004) Clin Implant Dent Relat Res , vol.6 , pp. 16-23
    • Feldman, S.1    Boitel, N.2    Weng, D.3    Kohles, S.S.4    Stach, R.M.5
  • 17
    • 1642410940 scopus 로고    scopus 로고
    • The success and failure rates of 9 mm or shorter ITI implants in the replacement of missing maxillary molars when restored with individual crowns: Preliminary results in 0 to 84 months in function A retrospective study
    • Fugazzotto PA, Beagle JR, Ganeles J, Jaffin R, Vlassis J, Kumar A. The success and failure rates of 9 mm or shorter ITI implants in the replacement of missing maxillary molars when restored with individual crowns: Preliminary results in 0 to 84 months in function. A retrospective study. J Periodontol 2004; 75: 327-332.
    • (2004) J Periodontol , vol.75 , pp. 327-332
    • Fugazzotto, P.A.1    Beagle, J.R.2    Ganeles, J.3    Jaffin, R.4    Vlassis, J.5    Kumar, A.6
  • 18
    • 47249111282 scopus 로고    scopus 로고
    • Shorter implants in clinical practice: Rationale and treatment results
    • Fugazzotto P. Shorter implants in clinical practice: Rationale and treatment results. Int J Oral Maxillofac Implants 2008; 23: 487-496.
    • (2008) Int J Oral Maxillofac Implants , vol.23 , pp. 487-496
    • Fugazzotto, P.1
  • 20
    • 0042012798 scopus 로고    scopus 로고
    • Immediate functional loading of Brånemark System implants with enhanced initial stability: A prospective 1-to 2-year clinical and radiographic study
    • Calandriello R, Tomatis M, Rangert B. Immediate functional loading of Brånemark System implants with enhanced initial stability: A prospective 1-to 2-year clinical and radiographic study. Clin Implant Dent Relat Res 2003; 5(suppl 1): 10-20.
    • (2003) Clin Implant Dent Relat Res , vol.5 , pp. 10-20
    • Calandriello, R.1    Tomatis, M.2    Rangert, B.3
  • 21
    • 20744446270 scopus 로고    scopus 로고
    • Short implants in the severely resorbed maxilla: A 2-year retrospective clinical study
    • Renouard F, Nisand D. Short implants in the severely resorbed maxilla: A 2-year retrospective clinical study. Clin Implant Dent Relat Res 2005; 7(suppl 1):S104-S110.
    • (2005) Clin Implant Dent Relat Res , vol.7 , pp. S104-S110
    • Renouard, F.1    Nisand, D.2
  • 22
    • 0034265296 scopus 로고    scopus 로고
    • A multicenter report on 1,022 consecutively placed ITI implants: A 7-year longitudinal study
    • Brocard D, Barthet P, Baysse E, et al. A multicenter report on 1,022 consecutively placed ITI implants: A 7-year longitudinal study. Int J Oral Maxillofac Implants 2000; 15: 691-700.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 691-700
    • Brocard, D.1    Barthet, P.2    Baysse, E.3
  • 23
    • 0347418233 scopus 로고    scopus 로고
    • Clinical evaluation of short, machined-surface implants followed for 12 to 92 months
    • Tawil G, Younan R. Clinical evaluation of short, machined-surface implants followed for 12 to 92 months. Int J Oral Maxillofac Implants 2003; 18: 894-901.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 894-901
    • Tawil, G.1    Younan, R.2
  • 24
    • 33750568455 scopus 로고    scopus 로고
    • Short dental implants as a treatment option: Results from an observational study in a single private practice
    • Arlin ML. Short dental implants as a treatment option: Results from an observational study in a single private practice. Int J Oral Maxillofac Implants 2006; 21: 769-776.
    • (2006) Int J Oral Maxillofac Implants , vol.21 , pp. 769-776
    • Arlin, M.L.1
  • 25
    • 33947145774 scopus 로고    scopus 로고
    • Short implants placed one-stage in maxillae and mandibles: A retrospective clinical study with 1 to 9 years of follow-up
    • Maló P, de Arújo Nobre M, Rangert B. Short implants placed one-stage in maxillae and mandibles: A retrospective clinical study with 1 to 9 years of follow-up. Clin Implant Dent Relat Res 2007; 9: 15-21.
    • (2007) Clin Implant Dent Relat Res , vol.9 , pp. 15-21
    • Maló, P.1    de Arújo Nobre, M.2    Rangert, B.3
  • 26
    • 0034584486 scopus 로고    scopus 로고
    • The influence of bone thickness on facial marginal bone response: Stage 1 placement through stage 2 uncovering
    • Spray JR, Black CG, Morris HH, Ochi S. The influence of bone thickness on facial marginal bone response: Stage 1 placement through stage 2 uncovering. Ann Periodontol 2000; 5: 119-128.
    • (2000) Ann Periodontol , vol.5 , pp. 119-128
    • Spray, J.R.1    Black, C.G.2    Morris, H.H.3    Ochi, S.4
  • 28
    • 0028394579 scopus 로고
    • The influence of the masticatory mucosa on the peri-implant soft tissue condition
    • Wennström JL, Bengazi F, Lekholm U. The influence of the masticatory mucosa on the peri-implant soft tissue condition. Clin Oral Implants Res 1994; 5: 1-8.
    • (1994) Clin Oral Implants Res , vol.5 , pp. 1-8
    • Wennström, J.L.1    Bengazi, F.2    Lekholm, U.3
  • 30
    • 43149110384 scopus 로고    scopus 로고
    • Width of keratinized gingiva and the health status of the supporting tissues around dental implants
    • Bouri A Jr, Bissada N, Al-Zahrani MS, Faddoul F, Nouneh I. Width of keratinized gingiva and the health status of the supporting tissues around dental implants. Int J Oral Maxillofac Implants 2008; 23: 323-326.
    • (2008) Int J Oral Maxillofac Implants , vol.23 , pp. 323-326
    • Bouri, A.1    Bissada, N.2    Al-Zahrani, M.S.3    Faddoul, F.4    Nouneh, I.5
  • 31
    • 73349106551 scopus 로고    scopus 로고
    • The influence of soft tissue thickness on crestal bone changes around implants:A 1-year prospective controlled clinical trial
    • Linkevicius T, Apse P, Grybauskas S, Puisys A. The influence of soft tissue thickness on crestal bone changes around implants:A 1-year prospective controlled clinical trial. Int J Oral Maxillofac Implants 2009; 24: 712-719.
    • (2009) Int J Oral Maxillofac Implants , vol.24 , pp. 712-719
    • Linkevicius, T.1    Apse, P.2    Grybauskas, S.3    Puisys, A.4
  • 32
    • 47249134203 scopus 로고    scopus 로고
    • "Biologic width" and crestal bone remodeling with sintered poroussurfaced dental implants A study in dogs
    • Deporter D, Al-Sayyed A, Pilliar RM, Valiquette N. "Biologic width" and crestal bone remodeling with sintered poroussurfaced dental implants. A study in dogs. Int J Oral Maxillofac Implants 2008; 23: 544-550.
    • (2008) Int J Oral Maxillofac Implants , vol.23 , pp. 544-550
    • Deporter, D.1    Al-Sayyed, A.2    Pilliar, R.M.3    Valiquette, N.4
  • 33
    • 67650218468 scopus 로고    scopus 로고
    • Use of sintered porous-surfaced dental implants to restore single teeth in the maxilla: A 7-to 9-year followup
    • MacDonald K, Pharoah M, Todescan R, Deporter D. Use of sintered porous-surfaced dental implants to restore single teeth in the maxilla: A 7-to 9-year followup. Int J Periodontics Restorative Dent 2009; 29: 191-199.
    • (2009) Int J Periodontics Restorative Dent , vol.29 , pp. 191-199
    • MacDonald, K.1    Pharoah, M.2    Todescan, R.3    Deporter, D.4
  • 34
    • 47749124963 scopus 로고    scopus 로고
    • Ultrashort sintered poroussurfaced dental implants used to replace posterior teeth
    • Deporter D, Ogiso B, Sohn DS, Ruljancich K, Pharoah M. Ultrashort sintered poroussurfaced dental implants used to replace posterior teeth. J Periodontol 2008; 79: 1280-1286.
    • (2008) J Periodontol , vol.79 , pp. 1280-1286
    • Deporter, D.1    Ogiso, B.2    Sohn, D.S.3    Ruljancich, K.4    Pharoah, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.