메뉴 건너뛰기




Volumn 143, Issue 1, 2013, Pages 56-63

Patent foramen ovale in severe obstructive sleep apnea: Clinical features and effects of closure

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; APNEA HYPOPNEA INDEX; ARTERIAL OXYGEN SATURATION; ARTICLE; CHRONIC DISEASE; CONTRAST ECHOCARDIOGRAPHY; CONTROLLED STUDY; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; OXYGEN DESATURATION; OXYGEN DESATURATION INDEX; PATENT FORAMEN OVALE; POLYSOMNOGRAPHY; PREVALENCE; PRIORITY JOURNAL; RESPIRATORY TRACT PARAMETERS; SHUNTING; SLEEP DISORDERED BREATHING; TRANSCRANIAL DOPPLER; TRANSTHORACIC ECHOCARDIOGRAPHY;

EID: 84871984560     PISSN: 00123692     EISSN: 19313543     Source Type: Journal    
DOI: 10.1378/chest.12-0334     Document Type: Article
Times cited : (31)

References (35)
  • 1
    • 0021352808 scopus 로고
    • Incidence and size of patent foramen ovale during the first 10 decades of life: An autopsy study of 965 normal hearts
    • Hagen PT, Scholz DG, Edwards WD. Incidence and size of patent foramen ovale during the first 10 decades of life: an autopsy study of 965 normal hearts. Mayo Clin Proc. 1984;59(1):17-20. (Pubitemid 14175830)
    • (1984) Mayo Clinic Proceedings , vol.59 , Issue.1 , pp. 17-20
    • Hagen, P.T.1    Scholz, D.G.2    Edwards, W.D.3
  • 3
    • 0034636477 scopus 로고    scopus 로고
    • Prospective study of the association between sleep-disordered breathing and hypertension
    • DOI 10.1056/NEJM200005113421901
    • Peppard PE, Young T, Palta M, Skatrud J. Prospective study of the association between sleep-disordered breathing and hypertension. N Engl J Med. 2000;342(19):1378-1384. (Pubitemid 30262394)
    • (2000) New England Journal of Medicine , vol.342 , Issue.19 , pp. 1378-1384
    • Peppard, P.E.1    Young, T.2    Palta, M.3    Skatrud, J.4
  • 4
    • 15244344823 scopus 로고    scopus 로고
    • Long-term cardiovascular outcomes in men with obstructive sleep apnoea-hypopnoea with or without treatment with continuous positive airway pressure: An observational study
    • DOI 10.1016/S0140-6736(05)71141-7
    • Marin JM, Carrizo SJ, Vicente E, Agusti AG. Long-term cardiovascular outcomes in men with obstructive sleep apnoeahypopnoea with or without treatment with continuous positive airway pressure: an observational study. Lancet. 2005;365(9464):1046-1053. (Pubitemid 40386782)
    • (2005) Lancet , vol.365 , Issue.9464 , pp. 1046-1053
    • Marin, J.M.1    Carrizo, S.J.2    Vicente, E.3    Agusti, A.G.N.4
  • 6
    • 0038338404 scopus 로고    scopus 로고
    • Prevalence of patent foramen ovale in subjects with obstructive sleep apnea: A transcranial Doppler ultrasound study
    • DOI 10.1016/S1389-9457(02)00256-3
    • Beelke M, Angeli S, Del Sette M, et al. Prevalence of patent foramen ovale in subjects with obstructive sleep apnea: a transcranial Doppler ultrasound study. Sleep Med. 2003;4(3):219-223. (Pubitemid 36748607)
    • (2003) Sleep Medicine , vol.4 , Issue.3 , pp. 219-223
    • Beelke, M.1    Angeli, S.2    Del, S.M.3    Gandolfo, C.4    Cabano, M.E.5    Canovaro, P.6    Nobili, L.7    Ferrillo, F.8
  • 7
    • 0031963545 scopus 로고    scopus 로고
    • Prevalence of patent foramen ovale and its contribution to hypoxemia in patients with obstructive sleep apnea
    • Shanoudy H, Soliman A, Raggi P, Liu JW, Russell DC, Jarmukli NF. Prevalence of patent foramen ovale and its contribution to hypoxemia in patients with obstructive sleep apnea. Chest. 1998;113(1):91-96. (Pubitemid 28044930)
    • (1998) Chest , vol.113 , Issue.1 , pp. 91-96
    • Shanoudy, H.1    Soliman, A.2    Raggi, P.3    Liu, J.W.4    Russell, D.C.5    Jarmukli, N.F.6
  • 8
    • 4944240778 scopus 로고    scopus 로고
    • Power m-mode transcranial Doppler for diagnosis of patent foramen ovale and assessing transcatheter closure
    • DOI 10.1177/1051228404268743
    • Spencer MP, Moehring MA, Jesurum J, Gray WA, Olsen JV, Reisman M. Power m-mode transcranial Doppler for diagnosis of patent foramen ovale and assessing transcatheter closure. J Neuroimaging. 2004;14(4):342-349. (Pubitemid 39331618)
    • (2004) Journal of Neuroimaging , vol.14 , Issue.4 , pp. 342-349
    • Spencer, M.P.1    Moehring, M.A.2    Jesurum, J.3    Gray, W.A.4    Olsen, J.V.5    Reisman, M.6
  • 9
    • 11044221169 scopus 로고    scopus 로고
    • Second harmonic transthoracic echocardiography: The new reference screening method for the detection of patent foramen ovale
    • Daniëls C, Weytjens C, Cosyns B, et al. Second harmonic transthoracic echocardiography: the new reference screening method for the detection of patent foramen ovale. Eur J Echocardiogr. 2004;5(6):449-452.
    • (2004) Eur J Echocardiogr , vol.5 , Issue.6 , pp. 449-452
    • Daniëls, C.1    Weytjens, C.2    Cosyns, B.3
  • 10
    • 33846213136 scopus 로고    scopus 로고
    • The influence of patent foramen ovale on oxygen desaturation in obstructive sleep apnoea
    • DOI 10.1183/09031936.00035906
    • Johansson MC, Eriksson P, Peker Y, Hedner J, Råstam L, Lindblad U. The influence of patent foramen ovale on oxygen desaturation in obstructive sleep apnoea. Eur Respir J. 2007; 29(1):149-155. (Pubitemid 46092012)
    • (2007) European Respiratory Journal , vol.29 , Issue.1 , pp. 149-155
    • Johansson, M.C.1    Eriksson, P.2    Peker, Y.3    Hedner, J.4    Rastam, L.5    Lindblad, U.6
  • 11
    • 79956278599 scopus 로고    scopus 로고
    • Explantation of patent foramen ovale closure devices: A multicenter survey
    • Verma SK, Tobis JM. Explantation of patent foramen ovale closure devices: a multicenter survey. JACC Cardiovasc Interv. 2011;4(5):579-585.
    • (2011) JACC Cardiovasc Interv , vol.4 , Issue.5 , pp. 579-585
    • Verma, S.K.1    Tobis, J.M.2
  • 12
    • 0030943764 scopus 로고    scopus 로고
    • Percutaneous balloon catheter closure of a patent foramen ovale in a patient with pulmonary disease, profound hypoxemia, and normal right heart pressures
    • Allan JJ, Marinelli C, Dellsperger KC, Winniford MD. Percutaneous balloon catheter closure of a patent foramen ovale in a patient with pulmonary disease, profound hypoxemia, and normal right heart pressures. Clin Cardiol. 1997;20(3):307-309. (Pubitemid 27120173)
    • (1997) Clinical Cardiology , vol.20 , Issue.3 , pp. 307-309
    • Allan, J.J.1    Marinelli, C.2    Dellsperger, K.C.3    Winniford, M.D.4
  • 13
    • 33845364181 scopus 로고    scopus 로고
    • Hypoxemia from right-to-left shunting through a patent foramen ovale in right ventricular infarction: Treatment by revascularization, preload reduction, and, finally, interventional PFO closure [6]
    • DOI 10.1007/s00392-006-0442-3
    • Kuch B, Riehle M, von Scheidt W. Hypoxemia from right-to-left shunting through a patent foramen ovale in right ventricular infarction: treatment by revascularization, preload reduction, and, finally, interventional PFO closure. Clin Res Cardiol. 2006;95(12):680-684. (Pubitemid 44885253)
    • (2006) Clinical Research in Cardiology , vol.95 , Issue.12 , pp. 680-684
    • Kuch, B.1    Riehle, M.2    Von Scheidt, W.3
  • 15
    • 0025345447 scopus 로고
    • Right-to-left shunting through a patent foramen ovale without pulmonary hypertension. Transient improvement after balloon catheter closure
    • Remy-Jardin M, Remy J, Wallaert B. Right-to-left shunting through a patent foramen ovale without pulmonary hypertension. Transient improvement after balloon catheter closure. Chest. 1990;97(5):1250-1252. (Pubitemid 20166829)
    • (1990) Chest , vol.97 , Issue.5 , pp. 1250-1252
    • Remy-Jardin, M.1    Remy, J.2    Wallaert, B.3
  • 16
    • 3042767981 scopus 로고    scopus 로고
    • Right ventricular diastolic dysfunction and patent foramen ovale causing profound cyanosis
    • Shnaider H, Shiran A, Lorber A. Right ventricular diastolic dysfunction and patent foramen ovale causing profound cyanosis. Heart. 2004;90(6):e31.
    • (2004) Heart , vol.90 , Issue.6
    • Shnaider, H.1    Shiran, A.2    Lorber, A.3
  • 17
    • 0035100467 scopus 로고    scopus 로고
    • Hypoxemia related to right-to-left shunting through a patent foramen ovale: Successful percutaneous treatment with the CardioSeal device
    • Piéchaud JF. Hypoxemia related to right-to-left shunting through a patent foramen ovale: successful percutaneous treatment with the CardioSeal device. J Interv Cardiol. 2001; 14(1):57-60.
    • (2001) J Interv Cardiol , vol.14 , Issue.1 , pp. 57-60
    • Piéchaud, J.F.1
  • 18
    • 28444444493 scopus 로고    scopus 로고
    • Obstructive sleep apnoea and patent foramen ovale: Successful treatment of symptoms by percutaneous foramen ovale closure
    • DOI 10.1111/j.1540-8183.2005.00072.x
    • Agnoletti G, Iserin L, Lafont A, Sidi D, Desnos M. Obstructive sleep apnoea and patent foramen ovale: successful treatment of symptoms by percutaneous foramen ovale closure. J Interv Cardiol. 2005;18(5):393-395. (Pubitemid 41727017)
    • (2005) Journal of Interventional Cardiology , vol.18 , Issue.5 , pp. 393-395
    • Agnoletti, G.1    Iserin, L.2    Lafont, A.3    Sidi, D.4    Desnos, M.5
  • 20
    • 0026333617 scopus 로고
    • A new method for measuring daytime sleepiness: The Epworth sleepiness scale
    • Johns MW. A new method for measuring daytime sleepiness: the Epworth sleepiness scale. Sleep. 1991;14(6):540-545.
    • (1991) Sleep , vol.14 , Issue.6 , pp. 540-545
    • Johns, M.W.1
  • 22
    • 33947518138 scopus 로고    scopus 로고
    • The SF36 Version 2: Critical analyses of population weights, scoring algorithms and population norms
    • DOI 10.1007/s11136-006-9154-4
    • Hawthorne G, Osborne RH, Taylor A, Sansoni J. The SF36 Version 2: critical analyses of population weights, scoring algorithms and population norms. Qual Life Res. 2007;16(4):661-673. (Pubitemid 46474952)
    • (2007) Quality of Life Research , vol.16 , Issue.4 , pp. 661-673
    • Hawthorne, G.1    Osborne, R.H.2    Taylor, A.3    Sansoni, J.4
  • 23
    • 33749179497 scopus 로고    scopus 로고
    • Comparison of transthoracic echocardiography with harmonic imaging with transoesophageal echocardiography for the diagnosis of patent foramen ovale
    • DOI 10.1136/pgmj.2006.045021
    • Trevelyan J, Steeds RP. Comparison of transthoracic echocardiography with harmonic imaging with transoesophageal echocardiography for the diagnosis of patent foramen ovale. Postgrad Med J. 2006;82(971):613-614. (Pubitemid 44476221)
    • (2006) Postgraduate Medical Journal , vol.82 , Issue.971 , pp. 613-614
    • Trevelyan, J.1    Steeds, R.P.2
  • 24
    • 0842334628 scopus 로고    scopus 로고
    • Harmonic Imaging Improves Sensitivity at the Expense of Specificity in the Detection of Patent Foramen Ovale
    • DOI 10.1111/j.0742-2822.2004.02168.x
    • Madala D, Zaroff JG, Hourigan L, Foster E. Harmonic imaging improves sensitivity at the expense of specificity in the detection of patent foramen ovale. Echocardiography. 2004;21(1):33-36. (Pubitemid 38183769)
    • (2004) Echocardiography , vol.21 , Issue.1 , pp. 33-36
    • Madala, D.1    Zaroff, J.G.2    Hourigan, L.3    Foster, E.4
  • 25
    • 0028059955 scopus 로고
    • Transesophageal echocardiography and contrast-TCD in the detection of a patent foramen ovale: Experiences with 111 patients
    • Klötzsch C, Janssen G, Berlit P. Transesophageal echocardiography and contrast-TCD in the detection of a patent foramen ovale: experiences with 111 patients. Neurology. 1994;44(9):1603-1606. (Pubitemid 24286633)
    • (1994) Neurology , vol.44 , Issue.9 , pp. 1603-1606
    • Klotzsch, C.1    Janssen, G.2    Berlit, P.3
  • 26
    • 0026590633 scopus 로고
    • Detection of patent foramen ovale by transcranial contrast Doppler ultrasound
    • Karnik R, Stöllberger C, Valentin A, Winkler WB, Slany J. Detection of patent foramen ovale by transcranial contrast Doppler ultrasound. Am J Cardiol. 1992;69(5):560-562.
    • (1992) Am J Cardiol , vol.69 , Issue.5 , pp. 560-562
    • Karnik, R.1    Stöllberger, C.2    Valentin, A.3    Winkler, W.B.4    Slany, J.5
  • 27
    • 0027932157 scopus 로고
    • Comparison of transcranial contrast Doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients
    • DOI 10.1016/0002-9149(94)90407-3
    • Job FP, Ringelstein EB, Grafen Y, et al. Comparison of transcranial contrast Doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients. Am J Cardiol. 1994;74(4):381-384. (Pubitemid 24253477)
    • (1994) American Journal of Cardiology , vol.74 , Issue.4 , pp. 381-384
    • Job, F.P.1    Ringelstein, E.B.2    Grafen, Y.3    Flachskampf, F.A.4    Doherty, C.5    Stockmanns, A.6    Hanrath, P.7
  • 28
    • 19544375264 scopus 로고    scopus 로고
    • Improved detection of microbubble signals using power M-mode Doppler
    • Saqqur M, Dean N, Schebel M, et al. Improved detection of microbubble signals using power M-mode Doppler. Stroke. 2004;35(1):e14-e17.
    • (2004) Stroke , vol.35 , Issue.1
    • Saqqur, M.1    Dean, N.2    Schebel, M.3
  • 29
    • 33750532961 scopus 로고    scopus 로고
    • BioSTAR evaluation STudy (BEST): A prospective, multicenter, phase I clinical trial to evaluate the feasibility, efficacy, and safety of the BioSTAR bioabsorbable septal repair implant for the closure of atrial-level shunts
    • DOI 10.1161/CIRCULATIONAHA.106.664672, PII 0000301720061031000012
    • Mullen MJ, Hildick-Smith D, De Giovanni JV, et al. BioSTAR Evaluation STudy (BEST): a prospective, multicenter, phase I clinical trial to evaluate the feasibility, efficacy, and safety of the BioSTAR bioabsorbable septal repair implant for the closure of atrial-level shunts. Circulation. 2006;114(18):1962-1967. (Pubitemid 44665391)
    • (2006) Circulation , vol.114 , Issue.18 , pp. 1962-1967
    • Mullen, M.J.1    Hildick-Smith, D.2    De Giovanni, J.V.3    Duke, C.4    Hillis, W.S.5    Morrison, W.L.6    Jux, C.7
  • 32
    • 34248366417 scopus 로고    scopus 로고
    • Is transcranial Doppler for the detection of venous-to-arterial circulation shunts reproducible?
    • DOI 10.1159/000101466
    • Sastry S, Daly K, Chengodu T, McCollum C. Is transcranial Doppler for the detection of venous-to-arterial circulation shunts reproducible? Cerebrovasc Dis. 2007;23(5-6):424-429. (Pubitemid 46742332)
    • (2007) Cerebrovascular Diseases , vol.23 , Issue.5-6 , pp. 424-429
    • Sastry, S.1    Daly, K.2    Chengodu, T.3    McCollum, C.4
  • 33
    • 65349166276 scopus 로고    scopus 로고
    • Patent foramen ovale: Comparison among diagnostic strategies in cryptogenic stroke and migraine
    • Zito C, Dattilo G, Oreto G, et al. Patent foramen ovale: comparison among diagnostic strategies in cryptogenic stroke and migraine. Echocardiography. 2009;26(5):495-503.
    • (2009) Echocardiography , vol.26 , Issue.5 , pp. 495-503
    • Zito, C.1    Dattilo, G.2    Oreto, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.